Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹15.7 L+₹2,537 (0.16%)Rejected-Finance SIMURALI NADIA | PURBA BARDHAMAN | WEST BENGAL | 713502 | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹15.8 L+₹3,625 (0.23%)Rejected-Finance 14 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹25,443
Closing Date
1 Oct 2024, 3:20 pmClosed
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
Supply and Laying new LT cable by replaces existing LT cable Rattirer Sathi at Ranaghat SDH Ranaghat Nadia
2024_WBPWD_755417_1
WBPWD/EE/NED/Short NIQ/e-T/29/ (1st Call)24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹25,443
20 Mar 2025
21 Sept 2024
24 Nov 2025
21 Sept 2024
1 Oct 2024
21 Sept 2024
Amount
Distn. wiring in 1.1 KV grade , 2x 1.5 sq. mm (Ph. & N) and 1x 1.5 sq. mm as ECC and single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand:Finolex/RR Kabel/Polycab/Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 3 nos. copper bar with holes (for Ph, N & E) fixed/Sitted on bakelite/Hard Rubber insulator over the MS welded Special type Double Side chairs incl. bakelite/ Perspex top cover 3 mm thick and sheet metal (16 SWG) flushed in wall incl. mending good damages to original finish. Average run - 8 Mtr. [ 2 a (iii) / E- 9]
Distribution wiring in 1.1 KV grade 3 x 22/0.3 (1.5 sq. mm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make -:Finolex/RR Kabel/Polycab/Havells) partly in 20 mm size MMS PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19 mm bore, 3 mm thick polythene pipe [for horizontal & vertical run embedded in wall] to light/fan/call bell points with Piano Key type switch (Anchor) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 3 nos. suitable size “Ph, N & E” copper bar incl. bakelite/ perspex top cover 3 mm thick and incl. 175 mm x 100 mm x 65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed and the saddles should be fixed within maximum 325 mm interval) Average run - 8 Mtr. [ 5 b) / E- 15]
Distribution wiring in 1.1 KV grade 3 x 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed copper wire (Make - Finolex / Polycab / RR Kabel / Havells) in in 19 mm bore, 3 mm thick polythene pipe to 6 A, flush type Plug Socket & Piano Key type switch (Anchor) fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. On Board - [ 4 (a) / E- 15 ]
Supplying and fixing of following ways MCB SS enclosure (Make - Siemens/ Legrand/Havells) with IP- 30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment - 4 Way (D-9 / 11)
Supply & Fixing 240 V, 6 A, plug socket (Anchor) on sheet metal switch board embedded in wall incl. S & F 100 mm x 100 mm x 65 mm MS (16 SWG) switch board and bakelite/perspex top cover of 3 mm thick by brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required for wall bracket fan. (11 (a) , 12 (a)/ E 4 & 15 (a) / E 5)
S & F 240 V 2 no. 6 A plug socket & 2 no. 20 A Plug Socket with separate 2 no. 6 A & 2 no. 20 A Piano key type switch , flush type indicator (Anchor make) &16 A kit-kat flush type fuse ( brand approved by EIC) on sheet metal switch board embedded in wall incl S & F 240 x 200 x 65 mm MS CRC (16 SWG) switch board with bakelite top cover of 3 mm thick by brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS. ( For Use Server point & at different patient care place ) ( 27/ E-7]
S & F 240 V 4 nos. 6 A plug socket with separate 4 nos. 6A piano key type switch & flush type indicator (Anchor make) &16 A Switch type sp MCB ( brand approved by EIC) on sheet metal switch board embedded in wall incl S & F 240 x 200 x 65 mm on MS CRC (16 SWG) switch board with bakelite top cover of 3 mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS. (24/ E-7) ( For Computer Board)
S&F 240 V 1 no. 20 A Plug Socket with separate 1 no. 20 A Piano key type switch & (Anchor make) on sheet metal switch board embedded in wall incl S & F 175 mm x 100 mm x 65 mm MS CRC (16 SWG) switch board with bakelite top cover of 3 mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS. (22/E6)
S&F 240 V 1 no. 6 A plug socket with separate 1 no. 6 A piano type switch & indicator fixed on sheet metal switch board embedded in wall incl S & F 150 x100 x 65 mm MS CRC (16 SWG) switch board with bakelite top cover of 3 mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS. (E6/21)
Supply & Fixing 240 V, 20 A Piano Key type Plug Socket (Anchor) on sheet metal switch board incl. S & F 100 mm x 100 mm x 65 mm MS (16 SWG) switch board and bakelite/perspex top cover of 3 mm thick by brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (For AC machine) [11(a)/E-4 ,12(a)/E-4,& 15(b) / 73]. (For AC machine/ Projector )
Supply & Fixing 240 V, 25 A Modular type starter (Make - Legrand / North West) with 25 A Modular switch type SP/ DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/E-19]. (For AC Machine)
Supplying and Drawing 1.1 KV Gr. single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make - Finolex / Polycab / RR Kabel / Havells) of the following sizes in the prelaid polythene pipe as per GS. 3 x 1.5 sq. mm (for use of 6 A Plug socket & internal circuit [1(b) / E-9 ] )
2 x 2.5 sq. mm + 1 x 1.5 sq. mm (For Power plug, Compound light & Computer Plug) [ 1(s) / E-9 ]
2 x 4 sq. mm + 1 x 2.5 sq. mm ( for AC & heavy power line of instrument.) [1(v) / E-9 ]
2 x 6 sq. mm + 1 x 4 sq. mm (From TPNDB to SPNDB,) [1 (y) / E- 9 ]
4 x 16 sq. mm + 2 x 10 sq. mm (From VTPNDB to TPNDB ) [1 (g1) / E- 9 ]
Cutting Channel of size ( 40 mm x 40 mm ) /(43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19/25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS. 19 mm dia 3 mm thick [ 6(a)/ E- 3 ]
25 mm dia 3 mm thick [ 7 (a)/ E- 3 ]
Making 50 mm dia holes on 125 mm depth RCC ceiling. [9(b)/E-3]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 100 mm x 100 mm x 65 mm [11(a)/E-4]
150 mm x 100 mm x 65 mm [11(b)/E-4]
175 mm x 100 mm x 65 mm [11(c)/E-4]
200 mm x 150 mm x 65 mm [11(d)/E-4]
Supply & Fixing bakelite / Perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 100 mm x 100 mm x 65 mm [12(a)/E-4]
150 mm x 100 mm x 65 mm [12(b)/E-4]
175 mm x 100 mm x 65 mm [12(c)/E-4]
200 mm x 150 mm x 65 mm [12d)/E-4]
Finishing of the following PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. Page F-5, Item No. 9. 3 x 22 / 0.3 (1.5 sq. mm) /2.5 Sq.mm
2 x 2.5 sq. mm + 1 x 1.5 sq. mm
2 x 4 sq. mm + 1 x 2.5 sq. mm
2 x 6 sq. mm + 1 x 4 sq. mm
4 x 16 sq. mm + 2 x 10 sq. mm
Supplying and fixing 415 V, 32 A per way double door HTPN MCB DB (Make - Siemens/ Legrand/Havells) with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ---- [14 / D- 10 ] 6 Way ( For this Project 2 Nos & Replaces existing 2 Nos at Different Sites of RSDH )
4 Way ( For this Project )
Supplying and fixing 240 V, double-door SPN MCB Distribution Board ( (Make - Siemens/ Legrand/Havells ) with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. ---- [13 / D- 10 ] 2+10 Way ( For This Project )
2+14 Way ( Replaces existing 4 Nos at Different Sites of RSDH )
Supplying and fixing of following rating 240/415 V 2/4 MCB type pole Isolator ( (Make - Siemens/ Legrand/Havells) on din rail of existing DBs and necessary connection. 6 / D-5. 415 V, 63 A FP
Supplying and fixing 240 V, 6/10/16/20/25/32 A SP MCB of Breaking capacity 10 kA & C characteristics ( (Make - Siemens/ Legrand/Havells) on din rail of HTPN and SPN DBs and necessary connection. 7 / D-6.
Supplying and fixing 415V, 63 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make - Siemens/ABB/Schneider) [ 4( a )/D-3 ] ( Replaces Damages SFU )
Supplying and fixing 415 V, 4 pole 160 A Change over switch with sheet steel enclosure on angle iron frame on wall with nuts bolts etc(Make - Siemens/ABB/Schneider/ Havells ) .( 3b / D-2)
Supplying and fixing 415 V, 4 pole 315/320 A Change over switch with sheet steel enclosure on angle iron frame on wall with nuts bolts etc(Make - Siemens/ABB/Schneider/ Havells ) .( 3b / D-2)
Supply of box type, 4 feet long single T-8 LED tube light fittings complete with all accessories [Make - Phillips, Cat No. - TMC 502 P 1x T-LED 22 W /Wipro, Cat No. WIO912208 / Havells Cat No Havells STREAKNEO T8UPTO I X 22 N SSBS WH) ] [NS]
Supply of box type, 4 Feet long twin T-8 LED tube light fittings complete with all accessories [ Make - Phillips, Cat No. - TMC 502 P 2x T-LED 22 W /Wipro, Cat No. WIO922208 /Havells Cat No Havells STREAKNEO T8UPTO 2 X 22 N SSBS WH] [NS]
Supply of 4 feet long 18/20 Watt, polycarbonate LED T-8 lamp (Make - Philips Master LED tube model no. 18W 865 T8 I 2100 lm/Wipro, Cat No. LL13-181-65SESL / Havells Crystal TLI8W LED865 SS Glass ]. [NS]
S& D of 240 V, 9 W B-22,CDL Energy Saver Led Bulb (Make:Philips/Crompton/Wipro).
Supply of 240 V, 1200 mm (48") sweep AC Ceiling fan complete with all accessories [Make -Crompton, 1200 mm Energion Riviera ( W/O Remote ) 32 Watt / Orient Aeroquiet BLDC 1200 MM ( With Remote ) / Atomberg Renesa Alpha , Colour - Brown]
Supply of 1.1 kV Gr. 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cable [Make Gloster/Polycab/ Havells] of following sizes ---- 50 sq. mm (NS) [From New Sub-Station Main Panel to Main Gate of Emergency Main switch ]
120 sq. mm (NS) [From Old Sub-Station Main Panel to Main Gate of Emergency Main switch ]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per GS. [1(a)/F-2 ]
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand [ F3 / 4(a)]
Laying only Cable above 4 core 50 sq. mm but not exceeding 4 core 400 sq. mm through existing RCC/ Hume/GI Pipe/open masonry trench. [3 (b)/F-2 ]
Laying of following sizes 4 core Armoured/Aluminum conductor cable on wall/surface including S & F MS clamps with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 90-150 / 185 sq. mm [ F 1 / 2 (e)]
Laying of following sizes 4 core Armoured/Aluminum conductor cable as below after cutting floor/pavement/wall and making holes incl. embedding the cables at an average depth as below and nending good the damages to original finish incl. removing the rubbish 185 sq. mm at an average depth of 100 mm in floor/pavement/wall etc. [ F 3 / 5 (iii)]
Supplying and fixing compression type gland complete with brass gland , brass ring & rubber ring for dust & moisture proof entry of XLPE / PVC armoured cables as below Dowels make gland as per GS 4 Core 50 Sq.mm [7(c)/F4 ]
4 Core 120 Sq.mm [7(c)/F4 ]
Finishing of the XLPE / PVC insulated armoured cable ends by crimping method incl. supplying & fixing solder less socket ( DOWELS ) make , tapes , anticorrosive paste & jointing materials as per GS. 4 Core 50 Sq.mm [7(c)/F4 ]
4 Core120 sq.mm [ 8(b)/ F5 ]
Supplying & fixing medium gauge GI pipe (ISI - Medium) protection with necessary fittings and jointing materials as required . 80 mm dia [F 6 / 11 f]
Supply of Led street light (230 V 35Watt to 45 Watt 5500 K ,IP 66 ,THD <10% ,Built in 2.54 SPD )LED Light Fittings. ( Make - Philips , / Wipro / Havells /Cromptons /panasonic /Bajaj )
Supply of 240V, 70 / 72 W LED Street light make Philips Cat no. BRP502 LED126 CW R3C PSU S1 / Wipro LR26-112-XXX-65-XX / Equivalent model of Havells ( For existig Steel Tubular Pole )
Supplying & drawing of 1.1 KV. Gr. 3 core 1.5 sq. mm PVC insulated Cu. wire (Make - Finolex/Havells/Polycab) through 20 mm dia 3mm thick(uniformly) soft drawn polythene pipe from Pole Loop Box to LED fittings (NS)
Cutting Channel of 40 mm x 40 mm size on masonry wall by Electric operated cutting machine incl. supplying & fixing 19 mm dia 3 mm thick heavy gauge polythene pipe by means of anchoring chemical (Hilti/Sika), GI 'U' hooks of 8 SWG, 18 SWG GI wire as fish wire and mending good damages to original finish by using own tools and tackles. [6(b)/ E-3]
Finishing of the following PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [9/F-5] 3 x 22 / 0.3 (1.5 sq. mm) /2.5 Sq.mm
Supplying & fixing socket type fan regulator (Step Type) Anchor make on existing sheet metal switch board with bakelite / perspex top cover by screw after making housing for regulator knob by cutting bakelite / perspex top cover including making necessary connections etc. [18(a) /E-6]
Fixing only outdoor / Street Light type fluorescent light fittings or LED light fittings complete with all other accessories to be fixed / projected from the wall of the building incl. making holes / providing 2 nos. MS clamping arrangement made with 40 mm x 6 mm MS flat & fixing 9 mm x 10 -150 mm nut bolts in wall after making hole in wall and mending good damages to finish also S & F 40 mm dia GI Pipe ISI make medium / required size dia GI pipe 1.50 mtr. average length having suitable bend / as per instruction of EIC incl. S & F necessary length of 3 x 1.5 sq.mm copper wire and making necessary connections as required and shoul;d be earthed properly and painting . (19 /C 3)
S & F of 2 mm thick, stainless steel sheet fabricated, water proof type looping cable box (200 mm x 150 mm x 100 mm deep) comprising of one 240 V, 16 A kit-kat fuse unit, 4 nos. 16 A stud type connectors, lined with rubber gasketed hinged top cover with mechanical locking arrangement etc., earthing terminal with lug on pole above the muffing with S&F 2 nos. flat iron clamp set made with 30 mm x 4 mm thick flat iron bar with nut-bolt etc. suitable for fixing above mentioned loop box on the pole including painting with anticorrosive paint. NS
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by ISI Medium GI pipe as to GS (2 a / G1 ).
S&F earth bus bar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the bus bar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd. as to GS ( 4 a / G - 2)
LOKNATH ENGINEERING (BID ID -5637049)
T.D.K. ENTERPRISE (BID ID -5661593)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .