Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹8.0 L (7.23%)Admitted-Finance 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | ₹1.2 Cr+₹8.0 L (7.23%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Anil Kumar Yadav L1 | M/S SMM INFRATECH PVT Ltd L2 |
|---|---|---|---|---|---|
| 0.00All Materials Provided by the Contractor as per Resspo Norms PART-A (Supply) | |||||
| 1.00 | Stone Pad | 50 | No. | 150 ₹7,500 Lowest | 180 ₹9,000 |
| 2.00 | 11 KV Pin Insulator with Pin | 6 | No. | 170 ₹1,020 Lowest | 195 ₹1,170 |
| 3.00 | 33 KV Pin Insulator with Pin | 135 | No. | 675 ₹91,125 | 475 ₹64,125 Lowest |
| 4.00 | 11 KV Disc Insulator with Fitting | 6 | No. | 350 ₹2,100 Lowest | 390 ₹2,340 |
| 5.00 | 33 KV Disc Insulator B&S Type 70 KN | 156 | No. | 350 ₹54,600 Lowest | 410 ₹63,960 |
| 6.00 | 33 KV Disc Fitting B&S Type 70 KN | 39 | No. | 200 ₹7,800 Lowest | 250 ₹9,750 |
| 7.00 | ACSR Panther Conductor for Bus Bar | 100 | Mtr. | 210 ₹21,000 Lowest | 270 ₹27,000 |
| 8.00 | Stay Set Complete | 36 | No. | 2,000 ₹72,000 Lowest | 2,500 ₹90,000 |
| 9.00 | Earthing Complete | 43 | No. | 1,170 ₹50,310 | 675 ₹29,025 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
4 Nov 2024, 5:00 pmClosed
Superintending Engineer
Please Refer Tender Form
Turn Key Basis work against Deposit scheme under EDD-2, Nanpara
2024_MVVNL_963196_2
54/EDC(B)/2024-25
Open Tender
Electrical Works
Item Rate
90 days
Bahraich
Please Refer Tender Form
3 documents required · 3 mandatory
₹5,900
Superintending Engineer, EDC
₹1.1 L
9 Nov 2024
26 Oct 2024
5 Nov 2024
26 Oct 2024
4 Nov 2024
26 Oct 2024
Amount
All Materials Provided by the Contractor as per Resspo Norms PART-A (Supply)
Stone Pad
11 KV Pin Insulator with Pin
33 KV Pin Insulator with Pin
11 KV Disc Insulator with Fitting
33 KV Disc Insulator B&S Type 70 KN
33 KV Disc Fitting B&S Type 70 KN
ACSR Panther Conductor for Bus Bar
Stay Set Complete
Earthing Complete
Barbed Wire
Top Channel 125x65, 32
Top Channel 100x65, 32
X-Base Angle
33 KV Cable Jointing Kit O/D
11 KV Cable Jointing Kit I/D 3x300sqmm XLPE Cable
11 KV Cable Jointing Kit O/D 3x300sqmm XLPE Cable
11 KV Cable Jointing Kit I/D 3x185sqmm XLPE Cable
11 KV Cable Jointing Kit O/D 3x185sqmm XLPE Cable
Control Cable 6x2.5mmsq
Control Cable 4x2.5mmsq
Control Cable 2x2.5mmsq
Alluminium Binding Wire
Earth Wire Clamp
Alluminium Tape
11 KV XLPE Cable 3x300sqmm
11 KV XLPE Cable 3x185sqmm
PG Clamp for Dog/Panther Conductor
CT O/D 33 KV CTR 200/100/1-1A
CT O/D 33 KV CTR 400/200/1-1A
33 KV PT O/D 33 KV/110V
PT Structure
CT Structure
Structure for Bus Isolator
Structure for Line Isolator
Structure for Post Insulator
Structure for LA
Main Bus Bar with Structure
Danger Board
F-Bracket for 33 KV Line
PP & Clamp with Nut Bolts for X-Arm
Number Plate with clamp
Terminal Gantry
Single T/F Control Pannel
Feeder Control Pannel
33 KV Bus Isolator 800 Amp
33 KV Line Isolator 800 Amp
33 KV Post Insulator
Lightening Arrestor 33 KV
GI Pipe 6 inch Dia
Earth Mat of Switchyard of 33/11 KV S/S
Eathing of Indoor Equipment
Connector for L.I/B.I/L.A/VCB/CT/PT
Nut & Bolt
Painting of S/S Structure
Alluminium Paint
Red Oxid Paint
Cable Stand
Netural Stand
Copper L Piece M/O 50x8mm
T&P Kit for S/S
Sundrles
E-Braket for 33 KV Line
E-Braket for 11 KV Line
24 Volt Battery & Battery Charger with cabinet as per Market Value Industrial
PART-B (Erection Work)
Cartage, Fabrication & Erection of Single ST Pole (11 Mtr Long) for 33 KV, 11 KV & HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site with complete fitting. All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
Cartage, Fabrication & Erection of Double ST Pole (11 Mtr Long) for 33 KV, 11 KV & HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. All the materials for fabrication shall be arranged by the contractor as per RESPO Norms.
Grouting of Poles with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely. (All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
Supply, Grouting nozzling & binding of stay sets with stay clamp complete fittings. (All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
Conctreeing of Structures as per RESSPO Norms
Earthing Complete at HT/LT Pole as per RESSPO Norms.
Boring Type Earthing utpo water level Complete as per RESSPO Norms.
Chemical Earthing for Battery Charge as per RESSPO Norms.
Laying Stone in Switchyard as per Respo Norms
Carriage & Laying of 33 KV 3x300sqmm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks with Complete Fitting.
Laying of Double circuit 11 KV 3x300sqmm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks with Complete Fitting.
Laying of Double circuit 11 KV 3x185sqmm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks with Complete Fitting.
Cartage & Laying, stringing, sagging, binding & jumpering of ACSR Dog conductors of 33 KV, clamp and binding wire proper connector & Clamp (600 Mtr. For Bus Bar) (Complete Fitting.)
Laying, stringing, sagging, binding & jumpering of Panther Conductors of 33 KV line of necessory clamp and binding wire proper connector & Clamp (Complete Fitting.)
GI Strip for Structure and equipment earthing Complete
Installation of 24 Volt Battery & Battery Charger with cabinet as per Market Value Industrial
Laying of Control with Complete Fitting
Fixing of 33 KV Cable Jointing kit O/D
Fixing of 11 KV Cable Jointing Kit I/D 3x300sqmm XLPE Cable
Fixing of 11 KV Cable Jointing Kit O/D 3x300sqmm XLPE Cable
Fixing of 11 KV Cable Jointing Kit I/D 3x185sqmm XLPE Cable
Fixing of 11 KV Cable Jointing Kit O/D 3x185sqmm XLPE Cable
Fixing of Single T/F Control Pannel
Fixing of Connector for L.I/B.I/L.A/VCB/CT/PT
Fitting of Feeder Control Panel
Erection & Fixing of Eathing of Indoor Equipment
Installtion of CT O/D 33 KV CTR 200/100/1-1A
Installtion of CT O/D 33 KV CTR 400/200/1-1A
Installtion of 33 KV PT O/D 33 KV/110V
Cartage & Installtion of 11 KV Incomeing Switch Gear 600/300/5A, 350 MVA
Cartage & Installtion of 11 KV Outgoing Switch Gear 200/100/5A, 250 MVA
High Pressure testing of XLPE cable, Testing equipment will be arranged by the contractor.
Insllation of Terminal Gantry as Per Assign Attached.
Cartage & Fixing of 11 KV Bus Coupler
Cartage & Fixing of 33 KV VCB 1250A
Cartage & Fixing of 33 KV VCB 800A
Fixing & Installation of PT Structure as per Resspo Norms.
Fixing & Installation of CT Structure as per Resspo Norms.
Fixing & Installation of Main Bus Bar Complete with Structure
Fixing & Installation of Structure for Bus Isolator
Fixing & Installation of Structure for Line Isolator
Fixing & Installation of Structure for Post Insulator
Fixing & Installation of Structure for LA
Fixing of Lightening Arrestor for 33 KV Line
Fixing of Interlocking Bricks in Switchyard & approach Road (1.5x60sqmm) as per norms
Providing & Fixing of Sign Board and other sundery items of Sub Station as per norms
Fixing of Cable Stand as per norms
Fixing of Netural Stand as per norms
Commissing of 5 MVA T/F and VCB
Plinth and Foundation of VCB as per Respo Norms.
Plinth for Transformer with Rail Piece as per Respo Norms.
Welded Mesh Fencing with Gate Complete (40x48M) per Resspo Norms.
Fixing of 33 KV Bus Isolator 800 Amp
Fixing of 33 KV Line Isolator 800 Amp
Fixing of 33 KV Post Insulator
Fixing of Number Plate with clamp
Alluminium Painting work (ISI Mark Paint)
Red Oxide Painting work (ISI Mark Paint)
Fixing of Earth Wire Clamp
Fixing of PG Clamp for Dog/Panther Conductor
Fixing of Alluminium Tape
Mounting of 33/11 KV 5 MVA T/F with complete fitting.
Repairing of Trench Inside Control Room
Painting work of Sub Station Structure
Construction of Trench with Cover for Control cable
Construction of Trench with Cover for Power/Control cable
Repairing of Control Room/Store Romm/JE Staff Room/Toilet/Fixing of Supply water supply (Civil/Electrical works) as per norms
Dismantling of 3x1.5MVA T/F
Dismnatling of 3 Nos 3.3 KV Incoming VCB and 03 Nos 3.3 KV Outgoing VCB Pannel with Bus Coupler
Dismnatling of T/F and Control Pannel to Electricity Store Centre, Brh
M/S SMM INFRATECH PVT Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
Re_Form54.pdf
Tender Documents • 1.44 MB
BOQ_1693863.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .