Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹8.4 L+₹1.4 L (19.5%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹9.0 L+₹2.0 L (28.5%)Rejected-Finance JAMMU PYRAMID CONSTRUCTIONS SAINIK COLONY JAMMU JAMMU 29 SECTOR SAINIK COLONY JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹9.7 L+₹2.7 L (37.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹9.8 L+₹2.7 L (38.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
27 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
REPAIR MAINT OF LT NETWORK AND ALLIED WORKS AT ZONE I MIL STN SAMBA UNDER GE SAMBA
2020_MES_361416_1
GE/SMB/T-17/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Samba
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹24,000
Yes
24 Sept 2020
16 Jul 2020
29 Aug 2020
16 Jul 2020
27 Aug 2020
1 Aug 2020
16 Jul 2020 - 18 Jul 2020
60 days
Amount
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
All as per srl item No.1 above here-in-before but bepth exceeding 1.5 Mtr and not exceeding 3 mtr complete all as spd and directed.
Returning filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick in any type soil complete all as spd and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as spd and directed.
M & L for Sand cushioning for under ground cable upto 8 cm before laying the cable and 15 cm after laying and stretching the cable and punned down to form a bed to a minimum 23 cm.The punning shall be done by hand complete all as specified in clause 19.75 of SSR Part - I of 2009.
Material and labour for sub class 'B' bricks well burnt of size laid dry flat for protection of cable complete all as spd and directed.
M & L for PCC 1:4:8 type D-2 using 40mm grade stone aggregates as in foundation land mass concrete for foundation concrete of poles complete all as spd and directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded broken stone aggregate as in mass concrete in foundations for stay/copings etc complete all as specified and directed .
Supply & erection Prestressed concrete pole 09 Mtr long 102 x172mm at top and 102x279mm at bottom class-10 errecting in truely vertical position complete all as spfd.(Earth work and PCC to be measured and paid for separately) making 30 cm wide strip (total 5 nos) with black and yellow paint including numbering complete all as spd and directed.(Note –necessary excavation ,removal and PCC shall be measured and paid under respective item of Sch.).
M&L for cross arms bracing supports clamps, back plates fabricated from steel section incuding nuts,bolts and washers welding,drilling hole complete with two coats of aluminium paint over one coat of primer complete all as specified.
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed heavy duty 1100 volts grade of size 240 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed heavy duty 1100 volts grade of size 150 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed heavy duty 1100 volts grade of size 95 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed heavy duty 1100 volts grade of size 70 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed heavy duty 1100 volts grade of size 50 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying XLPE insulated screened ,PVC bedded ,galvanised steel strip or wire armoured electric power cable (heavy duty ) 1100 volts grade with standard aluminium conductor 35 sqmm 3.5 core complete all as spd and directed.(Note –necessary excavation ,removal ,returning filling ,sand cushioning ,brick shall be measured and paid under respective item of Sch.).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed heavy duty 1100 volts grade of size 16 sqmm, 2 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed heavy duty 1100 volts grade of size 10 sqmm, 2 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Material and labour for GI tubing light grade for passing through cables under the floor ,along the wall, along the pole 40 mm bore complete all as specified and directed .
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32X6mm by means of nuts bolts,washers,check nuts of GI steel all as shown in electric plate no 5 all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe ,medium grade 40mm and GI watering pipe 20mm ,medium grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected all as specified and as directed.
Supply and fixing aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof and ground conductors and down conductors above ground complete all as spd and directed.
M & L for Cutting, trimming of hanging/ extended braches of trees upto a distance 3 meter from the overhead HT/LT line and making the line clear upto the entire length of the feeder including removal and disposal of the cut tree branches 50 meters away from the site complete all as specified and directed. Note : The Rates shall inclusive of T&P, hydraulic ladder, equipment such as motorised diesel operated hacksaw etc complete. One span comprises of 3 to 5 conductors of any distance between one pole to adjacent pole including trimming of all tree branches in vicinty & around poles /conductor & will be measured as one span. Necessary prior permission shall be obtained from concerned I/C JE E/M before carrying out the work. All safety measures & insurance to the staff undertaking the Job shall be the Contractor's responsibility.
Restringing/ restretching aluminium conductor on existing over head lines including necessary binding with binding wire with insulator , connections of incoming and out going cables complete all as specified and directed at various areas under complete all as specified and directed.
Taking down existing unserviceable /retrived old ACSR conductor from over head lines complete all as spd and directed.
Supply and fixing aluminum conductor steel reinforced (ACSR) for LT lines on steel tubular poles/PCC poles, streching without kinks and bends including aluminum binding wires complete all as spd and directed by Engr-in charge of size of conductor as per load .
Taking down unsv/dismantling insulators any type and size complete all as spd and directed.
Supply and fixing in replacement shackle type, procelain, vitreous, white, brown or green insulator including one galvanised iron steel straps, washer and insulator bolt dia 12 mm , washers, nuts one galvanised iron nut 75 mm height, 90 mm dia for 1100 volts grade including dismantling old unserviceable one.
M & L for Stay assembly complete with accessories as shown in electrical plate No. 1 of 16 mm dia complete all as specified and directed.
Supply and fixing in replacement loop type insulator, vitreous porcelain, white brown or green with overall dimensions 65x90 mm clearance of hole 16 mm complete all as specified.
Material and labour for galvanized stranded stay wire of size 7/4.00 mm including necessary binding with insulator, clamp and stay clamp complete all as spd and directed.
Supply and fixing aluminium lugs of suitable of size 50 Sqmm to be crimped properly to LT cable with crimping tool complete all as spd and directed.
Supply and fixing aluminium lugs of suitable of size 70 Sqmm to be crimped properly to LT cable with crimping tool complete all as spd and directed.
Supply and fixing aluminium lugs of suitable of size 95 Sqmm to be crimped properly to LT cable with crimping tool complete all as spd and directed.
Supply and fixing aluminium lugs of suitable of size 120 Sqmm to be crimped properly to LT cable with crimping tool complete all as spd and directed.
Supply and fixing aluminium lugs of suitable of size 185 Sqmm to be crimped properly to LT cable with crimping tool complete all as spd and directed.
Supply and fixing aluminium lugs of suitable of size 400 Sqmm to be crimped properly to LT cable with crimping tool complete all as spd and directed.
Taking out the old unserviceable /burnt MCCBs of various capacity and make from different LT panels after proper shutdown form the respective sub station and supply and fix for MCCB 400 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 36 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version) should be load line biased suitable for isolation. The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 36 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer, make: Siemens ( 3VL)/Legrand (DPX)/ABB (Tmax), Schneider Compact (NSX)/L&T(CM94105OOR1OG.
Taking out the old unserviceable /burnt MCCBs of various capacity and make from different LT panels after proper shutdown form the respective sub station and supply and fix for MCCB 250 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 25 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version) should be load line biased suitable for isolation. The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 25 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer, make: Siemens ( 3VL)/Legrand (DPX3)/ABB (Tmax), Schneider Compact (NSX)/L&T CM92109OON1OG.
Taking out the old unserviceable /burnt MCCBs of various capacity and make from different LT panels after proper shutdown form the respective sub station and supply & fix for MCCB 100 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 16 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version) should be load line biased suitable for isolation. The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 16 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer, make: Siemens ( 3VL)/Legrand (DPX3)/ABB (Tmax), Schneider (NSX)/L&T CM91712OOKOOG.
Taking out the unserviceable volt meter of any type and size and supply and fixing the digital volt meter with seletor switch (0-500 volt) including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as spd and directed.
Taking out the unservicable amp meter of any type and size and supply and fixing the digital amp meter with seletor switch (0-500 amp) including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as spd and directed.
Material and labour for painting of LT panels/feeder pillar boxes outdoor/indoor type of any sizes or rating installed at varoius location under GE Samba with two coat of super enamelled paint of approved colour with spray painting after cleaning the surface and preparing the same for painting including welding work to LT panels/feeder pillar box shutters as per requirement at site complete all as spd and directed.Note : Required accessories like hings ,handle and allied items as per job requirement shall deemed in the quoted rates.
Material and labour for end termination joint suitable for armoured XLPE cable 1100 KV rating heat shrinkable type complete with jointing accessories including taking down the existing loop and cutting of faulty cable of size 25 sqmm to 50 sqmm ,3.5/4 core complete all as specified:- Make of joints: DENSON/3M/M-SEAL/VENUS
All as per item no 43 above but for size 70 sqmm to 150 sqmm, 3.5/4 core.
All as per item no 43 above but for size 185 sqmm to 300 sqmm, 3.5/4 core.
Ashoka Engineers
Pyramid constructions
SIDDAHANT ENTERPRISES
M/S GUPTA TRADING CO
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .