| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.3 CrAccepted-AOC 10 YUBRAJ PALACE OLD AFI ROAD CHANDMARI GUWAHATI 781003 | KAMRUP METRO | ASSAM | 781003 | ₹50.3 Cr Quoted ₹51.6 Cr | L1 | Accepted-AOC L1 after rebate of 2.6 pc |
| 2 | L2₹52.2 CrRejected-AOC DAKHINGAON KAHILIPARA P O P S DISPUR ASSAM | ₹52.2 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹48.7 Cr
EMD Value
₹97.3 L
Closing Date
17 Oct 2022, 2:30 pmClosed
Sri Arun Ch. Goswami
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Construction of MCLA Quarter G5 at BTC, Kokrajhar 30 units including Civil, Electrical, Sanitary, Plumbing, Water Supply Works, Site Development, Furniture, Air Conditioner, Gym Equipment etc.
2022_BTC_27156_1
No.05/ACE/PWD/BTC/2022-23/10
Open Tender
Civil Works - Building
730 days
Kokrajhar
Refer to Tender Documents
5 documents required · 5 mandatory
₹20,000
₹97.3 L
Yes
Kokrajhar.
31 Dec 2022
23 Sept 2022
19 Oct 2022
23 Sept 2022
17 Oct 2022
23 Sept 2022
23 Sept 2022 - 17 Oct 2022
29 Sept 2022
Amount
CIVIL AND SANITARY WORKS: CARRIAGE OF MATERIAL 1.1: By Mechanical Transport including loading, unloading and stacking Earth
1.1.18: Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge
2.10: Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 2.10.1 All kinds of soil 2.10.1.1 Pipes, cables etc, not exceeding 80 mm dia.
2.16: Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 2.16.1 Depth not exceeding 1.5 m
2.27: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
2.28: Surface dressing of the ground including removing vegetation and in?equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift up to 1.5 m. 2.28.1 All kinds of soil
2.31: Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.33: Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. 2.33.1 Beyond 30 cm girth upto and including 60 cm girth
2.35: Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: 2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
2.35: Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.3 Treatment of soil under existing floors using chemical emul?sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
2.8: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
CEMENT CONCRETE (CAST IN SITU) 4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
4.9: Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing.
4.11: Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size)
4.12: Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (per 50 kg cement)
4.14: Extra for concrete work in superstructure above floor V level for each four floors or part thereof.
4.17: Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
5.3: Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
5.3: Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
5.41: Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. 5.41.1 Non pigmented wet curing compound
5.42: Providing and fixing parallel threaded couplers conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”, to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works per direction of Engineer- in-Charge. 5.42.2 Coupler for 20 mm diameter reinforcement bar
5.5A: Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 20%).
5.8: Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
5.44.2: Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).
5.9: Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
5.9.3 Suspended floors, roofs, landings, balconies and access platform
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7 Stairs, (excluding landings) except spiral-staircases
5.9.9 Arches, domes, vaults up to 6 m span
5.9.17 Cornices and mouldings
5.9.19 Weather shade, Chajjas, corbels etc., including edges
6.1: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13: Providing and laying autoclaved aerated cement blocks masonry with100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
8.2: Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.3 Granite stone slab all colour and texture except black, Cherry/Ruby red 8.2.3.2 Area of slab above 0.50 sqm
8.3: Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 8.3.2 Granite work
8.5: Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
9.1: Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.3 Kiln seasoned and chemically treated hollock wood
9.119: Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
9.5: Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters
9.14: Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).
9.21: Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
9.22 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 9.22.1 On one side only
9.48: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete
9.71: Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 9.71.1 125x64x2.50 mm
9.54: Providing beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : 9.54.1 Sal wood
9.74: Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.74.1 (250 X 10)MM
9.82: Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
9.83: Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
9.96: Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 9.96.1 300x16 mm
9.147D.1: Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. 9.147D.1 Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
10.17: Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
10.18: Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
10.20: Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.28: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in?charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Brick Soling: 11.2: Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
11.41A: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1 Double charge vitrified tile polished finish of size 11.41A.1.1 Size of Tile 600 x 600 mm
11.41A: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size 11.41A.3.1 Size of Tile 600 x 600 mm
11.5: 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
12.10: Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m²
12.36: Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge: 12.36.1 With Type N - Normal 50 mm thick
12.45: Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.4 Fully Perforated Gypsum Plaster Board of size 1200 x2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer?in-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60
12.55: Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
13.2: 15 mm cement plaster on the rough side of single or half brick wall o fmix : 13.2.1 1:4 (1 cement: 4 fine sand)
CEMENT PLASTER (IN FINE SAND) 13.3: 20 mm cement plaster of mix : 13.3.1 1:4 (1 cement: 4 fine sand)
12 mm cement plaster: 13.1.1 1:4 (1 cement : 4 fine sand)
PLASTER OF PARIS & WALL PUTTY 13.80: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.43: Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
13.48: Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
EXTERIOR FINISHING 13.44: Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
13.53: Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.53.1 New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution
CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT12 mm cement plaster finished with a floating coat of neat cement of mix : 13.7.2 1:4 (1 cement: 4 fine sand)
20.1: Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 20.1.3 500 mm dia piles
STEEL REINFORCEMENT 5.22A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
16.91: Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
18.7: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 18.7.4: 32 mm nominal dia Pipes
18.7.5: 40 mm nominal dia Pipes
18.8: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.3 25 mm nominal dia Pipes
18.34: Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
19.32: Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
18.48: Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
12.52: Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.52.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
26.1: Providing & fixing in position Phenol bonded Bamboowood flooring with planks of sizes 14mm thick, minimum 1800mm length and minimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge
26.3: Providing & fixing in position Phenol bonded Bamboowood wall cladding at all height with planks of sizes 10mm thick, minimum 1800mm length and minimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC), with necesasary profiled edges fixed with 40mm SS screws 5 nos in each tile to frame work made of second class teak wood of size 20x15 mm in centre of each tile and bottom and top of work height, 40x15mm placed at ends of each tile. The cladding shall be laid over backlayment of 1.00 mm thick expanded polyethylene foam of density 40kg/cum in two layers, first layer on wall surface before fixing wooden frame and second layer on frame under cladding. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.
8.9: Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. 8.9.18mm thick 8.9.1.1 Raj nagar plain white marble/ Udaipur green marble/ Zebra black marble
22.3: Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
17.7: Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
17.10: Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 17.10.1 Kitchen sink with drain board 17.10.1.1 510x1040 mm bowl depth 250 mm
17.32: Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.2 Rectangular shape 453x357 mm
17.68: Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
17.72: Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
23.2: Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 etre & upto 150 metre depth below ground level. 23.2.1 All types of soil 23.2.1.1 300 mm dia
23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 23.3.1 100 mm nominal size dia
23.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.4.1 100 mm nominal size dia
23.8: Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
23.12: Development of tube well in accordance with IS : 2800 (part I) and IS 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge.
P.A.R. 3.1.6: 16 Passenger, Speed 1.5m/sec, powered operated doors, AC variable voltage & variable
ANALYSIS 1: Providing and fixing UPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 100 mm nominal dia Pipes
ANALYSIS 2: Providing and fixing Victorian Shower Head along with Wall Mixer
ANALYSIS 3: Table Top Basin (ACS-WHT-87901; SIZE-575 X 430 X 175 MM)
ANALYSIS 4: BASIN MIXER WITHOUT POPUP WASTE SYSTEM 15MM CARTRIDGE SIZE; MODEL- ARC-87189
ANALYSIS 5: Waste coupling ; MODEL- ALD-CHR-727L130; FULL THREAD WITH 13MM HEIGHT
ANALYSIS 6: Swivel Mirror (630 X 445MM); Model- AKP-CHR-35795
ANALYSIS 7: TOWEL HOLDER; MODEL- QUA-CHR-61723
ANALYSIS 8: WALL HUNG WATER CLOSE with UF SOFT CLOSE SEAT COVER HINGES SET SIZE- 360 X 585 X 415MM; MODEL - OPS-WHT-15951UF
ANALYSIS 9: PNEUMATIC SINGLE PIECE SLIM CONCEALED CISTERN WITH FLOOR MOUNTING FRAM INSTALLATION KID AND P TYPE DRAIN PIPE CONNECTION SET FOR WALL
ANALYSIS 10: Two way Bib cock with wall flange; MODEL- ORP-10041PM
ANALYSIS 11: Pillar cock AUTO CLOSING; Model- PRS-CHR-031
ANALYSIS 12: EXPOSED PART KIT OF SINGLE LEVER BASIN MIXER WALL MOUNTED CONSISTING OF OPERATING LEVER CARTRIDGE SLEEVE WALL FLANGE NIPPLE & SPOUT (COMPATIBLE WITH ALD-233N & ALD-235N; Model- ALI- CHR-85233NK
ANALYSIS 13: Angular Stop cock with wall flangre; Model- leb-chr-45053
ANALYSIS 14: SINK COCK WITH REGULAR SWINGING SPOUT (WALL MOUNTED MODEL) WITH WALL FLANGE ; MODEL:- QQP-7347PM
ANALYSIS 15: TOILET ROLL HOLDER WITH FLAP ; MODEL- QUA-CHR-61753
ANALYSIS 16: Bottle trap ; MODEL-ALD-CHR-769L300X190; 32MM SIZE WITH 300MM & 190MM LONG WALL CONNECTION PIPES & WALL FLANGE
ANALYSIS 17: Health Faucet ; 8MM DIA 1.2 M LONG FLEXBLE TUBE AND WALL HOOK; MODEL NO- ALD-CHR-573
ANALYSIS 18: CILICA PNEUMATIC WHITE GLASS CONTROL PLATE; MODEL-ACP-CHR-573
ANALYSIS 19: HAND SHOWER 75MM DIA CYLINDRICAL SHAPE (RAIN MASSAGE & MIST) CHROME PLATED ABS BODY WITH GRAY FACE PLATE & RUBIT CLEANING SYSTEM; Model- HSH-CHR-1797
ANALYSIS 20: Victorian Shower Head Round Black Chrome ; MODEL-OHS-BCH-1843;
ANALYSIS 21: SHOWER ARM DIA. 20MM & 300MM LONG ROUND SHAPE WITH 90° BEND FOR WALL MOUNTED SHOWERS WITH FLANGE STAINLESS STEEL ; Model- SHA-BCH-479L300S
ANALYSIS 22: CONCEALED BODY FOY JOYSTICK DIVERTER 40MM CATRIDGE WITH BUTTON ASSEMBLY MODEL NO:- ARC-87065C
ANALYSIS 23: EXPOSED PART KIT OF JOYSTICK BASIN MIXER WALL MOUNTED CONSISTING OF OPERATING LEVER, CARTRIDGE SLEEVE, WALL FLANGE, NIPPLE & SPOUT ; MODEL NO:- ARC-87233K
ANALYSIS 24: SIGNAC SPOUT FOR BUILT IN BATH/SHOWE MIXER; MODEL- SPT-CHR-41429
ANALYSIS 25: TOWEL RECK WITH LOWER HANGER WITH HOOK; MODEL- AHS-1581H
ANALYSIS 26: OPTIMA SLIDING DR 8MM RT. (1000-1500MM) X 2000M; MODEL- JSE-CHR-OPTSDR1015X
ANALYSIS 27: WC BRUSH HOLDER; MODEL- QUA-CHR-61743
ANALYSIS 28: STAINLESS STEEL SHELFE; MODEL- QUA-CHR-61775
ANALYSIS 29: DOUBLE COAT HOOK; MODEL- QUA-CHR-61761
GEM PORTAL: 3HP Submersible Pump GEM-FILLOX PUMP 22 kiloWatt 136800 LPS Three Phase-Submersible Pump Set FILLOX PUMPR (DP8M33-605)
INTERNAL ELECTRICAL WORK (MCLA Qtr): 1.10.3: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.14: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.14.2: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.9: 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.14.10: 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.31: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1.32: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1.56: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
MR: Supply, fixing, Wiring, testing & commissioning for Single Phase 20/25 Amp power plug outlets in seperate recessed zinc chromate passivated MS box with 4 sq.mm. FR insulated copper conductor wires alongwith 2.5 sq.mm. FR insulated copper conductor wire for loop earthing in concealed 2mm thick PVC conduits ( ISI marked) as called for including providing 6 pin modular socket outlet with box, ferrule numbering, etc. complete as required for Geyser.
1.57: Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (AC)
2.18: Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
1.21: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1.26: Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.14: Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.14.2: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3: 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.9: 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.21: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1: 20 mm
1.20: Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1.20.2: 25 mm
Distribution Board: 2.3: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.2: 6 Way, Double Door
2.3.3: 12 Way, Double Door
2.4: Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 2.4.1: 4 way (4+12), Double door
2.4.2: 6 way (4+18), Double door
2.4.3: 8 way (4+24), Double door
2.5: Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.3: 12 way (4 + 36), Double door
2.10: Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1: Single Pole
2.12: Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1: 40 amps
2.13: Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.1: 40 amps
2.14: Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.2: 40 amps (30mA)
2.14.3: 63 amps (30mA)
2.11: Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1. Supply And Installation of light Fixture: The rates shall include all components that may be required to make the supply and installation complete in all respects such as : a. All lamps b. Internal wiring between accessories c. Earthing terminal d. Complete provision for installation e. Suitable length of GI down rod, hanger and connecting wires where called for. f. Wires for connecting the fixtures to the point through connector block. g. All metal blocks to serve as base of fixtures 2. Drilling holes in supports wherever required 3.Fixing clamps, GI bolts and nuts, brass screws, saddles, rawl bolts and other fixing accessories as required. 4. All recessed type fixture shall be considered with suitable length of flexible G.I. conduit. 5. Testing of all fixtures & fans before and after installation. A. Supply of lighting Fixturte: Supplying with fitting fixing of luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. 1. MR: FLOURESCENT TUBE LIGHT (TL)
2 MR: mirror light
3 MR: DECORATIVE BRACKET (BKD)
4 MR: 18W CEILING/SURFACE MOUNTED LED FIXTURE
5 MR: 1X18W LED LIGHT IN STAIRCASE AREA
6 MR: CEILING FAN
7 MR: Exhaust Fan : 450 mm sweep Metal Body Copper motor
Installation of Lighting Fixtures: 1.41: Installation, testing and commissioning of following pre-wired, LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44: Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1.45: Installation, testing and commissioning of ceiling fan,wiring the down rods of standard length (upto 30 cm) with 1.5 sq. including mm FR PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
1.35: Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
1.41: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required.
1.34: Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.25: Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.50: Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1: Upto 450 mm sweep
Cable Trays/Raceways: 4.6: Supplying and installing following size of perforated Hot Dipped,Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/shaft with G.I. suspenders including G.I. bolts & nuts, etc. as required & approved by the Engineer Incharge. (Quantity shall be confirmed at site as per final layout/ route/ application etc. & to be executed accordingly.) 4.6.6: 450 mm width X 50 mm depth X 1.6 mm thickness
4.6.4: 300 mm width X 50 mm depth X 1.6 mm thickness
4.6.2: 150 mm width X 50 mm depth X 1.6 mm thickness
Earthing: 5.4: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.5: Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but with charcoal/ coke and salt ) as required.
5.9: Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.11: Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
5.15: Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.19: Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
5.18: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
5.14: Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
CABLE LAYING, TERMINATIONS AND GLANDS: 7.7: Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 7.7.1: Upto 35 sq. mm
7.7.2: Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.7.4: Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
9.1: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.32: 4 core x 10.0 sq. mm. XLPE, Al.armoured cable.
9.1.33: 4 core x 16.0 sq. mm. XLPE, Al.armoured cable.
9.1.22: 3.5 core x 50.0 sq. mm. XLPE, Al.armoured cable.
9.1.30: 3.5 core x 300 sq. mm. XLPE, Al.armoured cable.
CABLE TRAY : 4.1: Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 4.1.1: 100 mm width X 50 mm depth X 1.6 mm thickness
4.1.2: 150 mm width X 50 mm depth X 1.6 mm thickness
4.1.6: 450 mm width X 50 mm depth X 1.6 mm thickness
4.1.7: 600 mm width X 50 mm depth X 1.6 mm thickness
4.2: Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 4.2.1: 100 mm width X 50 mm depth X 1.6 mm thickness
4.2.2: 150 mm width X 50 mm depth X 1.6 mm thickness
4.2.6: 450 mm width X 50 mm depth X 1.6 mm thickness
4.2.7: 600 mm width X 50 mm depth X 1.6 mm thickness
Data and TV points: 1.53: Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1.53.1: 1 run of cable
1.18: Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1.18.2: 2 Pair
1.19: Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
MR: Supplying and drawing co-axial TV cable RG-11 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required.
1.24: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.7: TV antenna socket outlet
1.24.6: Telephone socket outlet
1.38: Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
MR: Supply, erection, testing and commissioning of following tap off / splitter as per specification in 1.6mm thick CRCA sheet steel enclosure for CATV system. MR: 4 way splitter box
1.21: Supplying and fixing of following sizes of Heavy duty class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1: 20 mm
ELECTRICAL EXTERNAL WORK (MCLA): 7.7: Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 7.7.1: Upto 35 sq. mm
9.1: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.32: 4 core x 10.0 sq. mm. XLPE, Al.armoured cable.
9.1.33: 4 core x 16.0 sq. mm. XLPE, Al.armoured cable.
Earthing: 5.18: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for earthing along with existing surface/ recessed conduit as required.(pole Earthing)
Feeder Pillar: NSR: Design, fabrication, assembling, wiring, testing, supply, forwarding to site, unloading, shifting to location, inspection, installation, testing and commissioning of M.V.FEEDER PILLAR OUTDOOR TYPE Boards suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be fabricated out of 2 MM CRCA sheet steel in cubicle formation, compartmentalized, form 3b construction, free standing, floor mounting, dust and vermin proof with reinforcement of suitable size angle iron, channel, 'T' sections and/ or flats wherever necessary. The panel shall be treated with anti corrosive process before final powder coating. Separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi tier arrangement. A minimum of 400mm clearance shall be given from the floor level to the bottom most termination point. The painting shall be done in conformity with IS code.Adequate size cable alley shall be provided all round the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid bus bars. Flexible cable links are not acceptable. Bus bars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. The copper earth strip of adequate size in 2 runs shall run through out the perimeter of the bottom of the panel. The panel shall be fabricated only after the approval of fabrication drawings by the consultant. 100 Amp Al bus Bar 63 AMP FP MCCB 10KA-1 nos 16 AMP TPN MCB 10KA-8 nos Suitable timer and contactor arrangement to be maid off Panel as above
CABLE SUPPLY : Supplying of following 1100 volt grade XLPE insulated PVC inner sheathed and FRLS PVC outer sheathed copper/aluminium conductor armoured cables as per specification. NSR: 4 core x 10.0 sq. mm. XLPE, Cu. armoured cable.
NSR: 4 core x 16.0 sq. mm. XLPE, Cu. armoured cable.
Earthing: NSR: Supply and fixing 1 meter long GI Spike for pole earthing .
LIGHTING FIXTURE: NSR: Supplying installation testing & commissioning of 25W LED Street light fixture with System efficacy of 100 lm/W (2500 lumens). Luminaire shall be made up of die cast Aluminium housing with PC lens and ploycarbonate diffuser. Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 85% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.
NSR: Supplying installation testing & commissioning of 150W LED Floodlight fixture with System efficacy of 100 lm/W (15000 lumens). Luminaire shall be made up of die cast Aluminium housing with PC lens and toughened glass diffuser. Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 120-300V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 92% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.
NSR: Supplying installation testing & commissioning of 20W LED Post Top light fixture with System efficacy of 100 lm/W (2000 lumens). Luminaire shall be made up of die cast Aluminium housing with PC lens and toughened glass diffuser. Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 120-300V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 92% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.
NSR: Supplying installation testing & commissioning of 10W bollard light fixture with System efficacy of 100 lm/W (1000 lumens). Luminaire shall be made up of die cast Aluminium housing with PC lens and toughened glass diffuser. Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 120-300V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 92% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.
NSR: Supplying installation testing & commissioning of flexible LED strip light in 5 meter length with 12w/meter power consumption in façade area. Luminaire shall be with IP65 protection.
LIGHTING POLE: Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) NSR: 3 meter pole
NSR: 7 meter pole
Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size 48.3mm out side dia x 3.25mm thick Stiffener plate from arm of the following types : NSR: Single arm bracket 1500mm long for 3m to 10 metre. Poles.
NSR: Supplying and erecting Water tight M.S.Box of size 20 x 15 x 15 cm. to erect suitable kitkat fuse / MCB to be . erected on polished wooden board inside the box with hinged/sliding door with rubber rings and erected on pole with suitable pole clamp, all duly painted with one coat of red oxide and two coats of paints. (Cost of Fuse / MCB shall be taken extra)
NSR: Supplying and installation of pole earthing with 19mm dia 1.8 mtr. Long G.I. earth spike 750mm distance from pole at a depth of 250 mm below ground level complete with 10mm dia 50mm long G.I. nut, bolt, nuts and washers etc. as reqd.
320 KVA DIESEL GENERATOR SET (MCLA): Mahindra 320kVA (3Phase)DG Set with AMF Panel
500 KVA SUBSTATION (MCLA): Brand: Ajanata Transformers 500KVA 11/0.433 KV, 3 phase, 50C/S Copper wound distribution transfermer generally confirming to I 1180(Part-I)/2014 and total Losses confirming to 4 star rated transformer of BEE (ie total losses @50%loading: 1510 W & at 100% loading: 4300 W) and provided with standard fittinggs and accessories. :4-100 W) ancl provicieci uilh standarciFirst filling of Transformer Oil confirming to IS 335/1983 would also be provided.
PROVISION FOR SECURITY DEPOSIT AND SUPERVISION CHARGES: Load security deposit to be deposited to concerned Power Supply Agency with check meter as well as permission from Power Supply Authority including liasioning with all the concerned departments etc..
Construction of 3 phase 11 KV Line on G.I. steel tubular pole 12m SP-62 using AAA Raccoon conductor 7/3.81mm with T cross arm average span 70m.
Supervision Charges and Liaision Charges to be paid to Power Supply Agency
CCTV SYSTEM EQUIPMENT (IP) (MCLA): Supply, Installation & Commissioning of following CCTV System Component: 1.1: Indoor IP base 1/3"color auto iris Fixed lense CMOS Cameras (high resolution cameras / minimum 4mm Lance/ 3 megapixal /PoE) fitted enclosed in a discrete mirror dome complete with sockets as per specification and IR range min 30 Meter.
1.2: Indoor IP base 1/3"color auto iris verifocal lense CMOS wireless Cameras (high resolution cameras / minimum 4mm Lance/ 3 megapixal /PoE) fitted enclosed in a discrete mirror dome complete with sockets as per specification and IR range min 50 Meter.
1.3: Supply, installation, testing and commissioning of 55" totally flat colour LED monitor.
1.4: Supply, installation, testing and commissioning of 32 chanel Network video recorder with 2 SATA
1.5: 8TB survelience harddisk
1.6: Rj connectors
1.7: HDMI cable
INTERNAL HYDRANT PIPING WITH ACCESSORIES (WET RISER SYSTEM - PUMPING EQUIPMENTS) (MCLA): Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for nclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 4.1: 900 lpm at 35 m Head
20: Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
MR: Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications.
(HYDRANTS SYSTEM): 9: Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 9.1: Single headed gun metal
16: Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 16.2: Stainless Steel (Grade 304)
18: Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 18.2: Stainless Steel (Grade 304)
17: Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 (b) 20 mm nominal internal dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipmets on wall. (d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. (e) 40M
MR: SITC weather proof M.S cabinet size ( Door Size only = 1200 mm x 2100 mm x 600mm): Supplying, installation, testing and commissioning of weather proof M.S cabinet door size 1200 mm x 2100 mm x 600mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - a) Gunmetal single headed Hydrant valve - 1 No. b) Fire Hoses 63mm, 15 M long with accessories - 2 Nos. c) Short branch - 1 No. d) First Aid hose Reel - 1 No. e) Fire Extinguisher - 2 Nos. f) Fireman's Axe - 1 No. g) Pressure Gauge - 1 No. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade.
19: Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 19.1: 2 way-100 mm dia M.S. Pipe
(PIPING, VALVES AND ACCESSORIES) SLTC of M.S. pipe on surface: 7: Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 7.7: 100 mm dia
7.6: 80 mm dia
7.1: 25 mm dia
11: Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 11.5: 100 mm dia
14: Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. 14.5: 100 mm dia
13: Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
MR: Supply, Installation, Testing and Commissioning of 150 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2
MR: Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926
15: Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 15.2: 100 mm dia
MR: Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications. 100 mm dia
100 mm dia
(FIRE EXTINGUISHERS) MR: Providing Water based Carbon-di-oxide 9 ltrs. fire extinguishers as per IS specification consisting of welded MS cylindrical body ,squeeze lever discharge valve fitted with internal discharge tube ,30 cm long high pressure discharge hose ,discharge nozzle,suspension brackets,finished exteranally with red enemel paint and fixed to wall with brackets with rawl plug/dash fastners complete with initial charging.
MR: Providing ABC type (Dry powder type ) extinguishers. Including all accessories as per IS specification (IS :15683) Consisting of welded MS cylindrical body with discharge hose ,discharge valve ,suspension brackets,initial filling etc. complete as required., initial filling etc complete as required. Capacity - 6 kg 4.5kg capacity cylinder
SPRINKLER WITH PIPING ACCESSORIES: 7: Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 7.1: 25 mm dia
7.2: 32 mm dia
7.3: 40 mm dia
7.4: 50 mm dia
7.5: 65 mm dia
7.6: 80 mm dia
7.7: 100 mm dia
11: Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 11.5: 100 mm dia
11.2: 50 mm dia
14: Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. 14.5: 100 mm dia
NON DSR: Supply,Providing, fixing, testing & commissioning of SS spring loaded air relief valve for pressure of 16 kg/sqm of approved quality with gm isolation valve, tapers, G.I. pipes and specials etc. including making necessary screwed/ flanged joints by providing all jointing materials including painting and testing the joints to hydraulic pressures specified for pipes all complete as per drawings and as directed by the Engineer-in-Charge. 25 mm dia
23: Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 23.1: 100 mm dia
21: Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 21.1: Pendent Sprinkler
25: SS Flexible braided pipe for below false ceiling sprinkler (ul / fm approved) 800/1000 MM LENGTH (OPTIONAL)
16: Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
19: Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 19.1: 2 way-100 mm dia M.S. Pipe
DSR-E&M 2018 - Item no. -17.2.2: Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
DSR-E&M 2018 - Item no. -17.2.3: Supplying, installation, testing & commissioning of repeater panel wih 320 haracter/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
NON DSR: Addressable monitoring module (inbuilt with two nos fault isolator) to connect NO/NC contacts such as pressure switch, flow switches, fire pump contacts (provided by Fire fighting contractor). However testing and commissioning shall be included in the fire detection and alarm system contractor scope. Panel shall be located at Security room and reception area.
DSR-E&M 2018 - Item no. -17.2.10: Supplying, installation, testing & commissioning of addressable fire control module complete as required.
DSR-E&M 2018 - Item no. -17.2.4: Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
DSR-E&M 2018 - Item no. -17.2.6: Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
DSR-E&M 2018 - Item no. -17.2.9: Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
DSR-E&M 2018 - Item no. -17.2.14: Supplying, installation, testing & commissioning of addressable manual call point complete as required.
DSR-E&M 2018 - Item no. -17.2.7: Supplying, installation, testing & commissioning of fault isolator complete with base as required.
DSR-E&M 2018 - Item no. -17.2.15: Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
DSR-E&M 2018 - Item no. -17.2.11: Supplying, installation, testing & commissioning of addressable phone control module complete as required.
DSR-E&M 2018 - Item no. -17.2.19: Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
DSR-E&M 2018 - Item no. -17.2.5: Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
DSR-E&M 2018 - Item no. -17.2.17: Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
CABLES AND ACCESSORIES: DSR-E&M 2018 - Item no. -17.5.2: Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Providing and fixing furniture at Ground Floor with the following items of specified brand/make all complete as directed by the engineer-in-charge: RECEPTION LOBBY AND WAITING ROOM: 3 Seater Sofa (Model: BERRY/55003/A/3), Centre Table (Model: GLADE), Reception Table (Model: DWS/34723), Visitor Chair (Model: DEFINE/MB/PREMIUM), Office Chair (Model: DEFINE/HB/PREMIUM), VIP LOUNGE : 3 Seater Sofa (Model: CLARKSON/3), Arm Chair (Model: ARIANA), Centre Table (Model: CASPER/CT), TV Unit (Model: CASPER/TV), Pantry Table (Model: CATHERINE/CONSOLE), MEETING ROOM: 12 Seater Conference Table (Model: MERIDIAN/D (SEATING CAPACITY -8 PERSON), Low Height Storage (Model: MERIDIAN/E), LIBRARY: Office Chair (Model: DEFINE/HB/PREMIUM), Visitor Chair (Model: DEFINE/MB/PREMIUM), Low Height Storage (Model: DWS/34725), Office Desk (Model: DWS/34723), 4 Seater Dining Table (Model: NERO/A (RECTANGULAR), 2 Seater Dining Table (Model: BRIGHTON (ROUND), Library Shelves (Model: DWS/34760), DINNING: Chair (Model: DEFINE/HB/PREMIUM) Table (Model: DWS/34723), 4 Seater Dining Table (Model: NERO/A (RECTANGULAR), 2 Seater Dining Table (Model: BRIGHTON (ROUND), BACK OFFICE: Visitors Chair (Model: DEFINE/MB/PREMIUM), Office Chair (Model: DEFINE/HB/PREMIUM), Office Table (Model: DWS/34723), Low Height Storage (Model: DWS/34725), Shelves (Model: DWS/34760), STAFF ROOM: 3 Seater Sofa (Model: BERRY/55003/A/3), Arm Chair (Model: RACHEL), TV Unit (Model: JANE), Centre Table (Model: GLADE), Low Height Storage (Model: DWS/34725), STAFF DINING: Chair (Model: DEFINE/HB/PREMIUM), Table (Model: DWS/34723), 6 Seater Dining Table (Model: SADDLE/A), 4 Seater Dining Table (Model: NERO/A), GYM: Low Height Storage (Model: RICK (HEIGHT - 6FT.), Visitor Chair (Model: DEFINE/MB/PREMIUM), Office Chair (Model: DEFINE/HB/PREMIUM), Office Desk (Model: DWS/34723) etc.
Providing and fixing furniture each flat (1st floor to terrace) with the following items of specified brand/make all complete as directed by the engineer-in-charge: LIVING ROOM: 2 Seater Sofa (Model: BLOS/37930/G/2), 3 Seater Sofa (Model: BLOS/37930/G/3), Centre Table (Model: CASPER/CT), Side Table (Model: CASPER/ST), Low Height Units (Model: Low Height Units), Garden Chair and Table (Model: BRIGHTON), TV Unit (Model: CASPER/TV), DINING ROOM: 6 Seater Dining Table (Model: ELANOR), GARDEN TERRACE: Garden Chair and Table (Model: ADLER), BEDROOM 1 : Double Bed (Model: ROBINSON/KB), Arm Chair (Model: HARLOW/1 ), Garden Chair and Table (Model: BRENTON), Coffee Table (Model: IVARA), TV Unit (model: SCARLET/TV), Walk in Closet Wardrobe (Model: ROBINSON-900A/2D (HEIGHT - 8FT.), GUEST BEDROOM: Double Bed Queen Size (Model: WINSTON/QB/L-47), Arm Chair (Model: GEMINI), TV Unit (Model: EMMA), Wardrobe (Model: MARK-900A/2D (HEIGHT - 8FT.), MASTER BEDROOM : Double Bed (Model: NINA/KB/A), 2 Seater Sofa (Model: BROOKLYN), Dresser (Model: NINA/DRE/A/STL), TV Unit (Model: COLE), Garden Chair and Table (Model: BRENTON), Walk in Closet Wardrobe (Model: NINA-900A/2D (HEIGHT - 8FT.), OFFICE ROOM: 3 Seater Sofa (Model: JESSE/3/L-48), Office Chair (Model: RICH/37826/HB), Side Table (Model: BASSETT/ST), Visitor Chair (Model: MARVEL/MB/PREMIUM), Office Desk (Model: CLINT), Low Height Units (Model: CLINT/C ), SERVANT ROOM: Single Bed (Model: LEEDS SINGLE BED), Wardrobe (Model: RICK (HEIGHT - 6 FT.) .
Providing supply, fitting and installation Air Conditioning complete and as directed: i) Mitsubishi Make 2 TR Inverter Cassette Unit, ii) Mitsubishi Make 3 TR Inverter Cassette Unit, iii) Mitsubishi Make 3.5 TR Inverter Cassette Unit, iv) Mitsubishi Make 1 TR Hiwall Inverter Split Unit, v) Mitsubishi Make 1.5 TR Hiwall Inverter Split Unit, vi) Mitsubishi Make 2 TR Hiwall Inverter Split Unit, vii) For Cassette Unit Refrigerant copper piping 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulation, viii) For Cassette Unit Refrigerant copper piping 9.53 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation, ix) For Hiwall Split Unit Refrigerant copper piping, x) Supply & installation of CPVC piping complete with fit- tings, supports and duly insulated with 9 mm thick closed cell Class-O nitral rubber insulation. 25 mm dia Drain Pipe, xi) Gas Charging (R-410), xii) 4Core x 2.5 sq. mm for Cassette and Split AC, xiii) ODU Stand for Split Unit, xiv) ODU MS Angle for Cassette Unit, xv) Installation, Testing Commissioning Charge: 2 TR Cassette Unit , xvi) 3 TR Cassette Unit , xvii) 4 TR Cassette Unit and xviii) Hiwall Inverter Split Unit
Providing supply, fitting and fixing gym equipment complete as directed and specified by the engineer-in-charge: 1) Treadmill AF 103, 2) CROSS TRAINER 246 EL, 3) LAT PULL DOWN/ SEATED ROW AF 4501 , 4) LEG EXTENSION/ LEG CURL AF 4500, 5) REAR DELT /PEC FLY –(SO) AF 4414, 6) Functional Trainer AF 9914, 7) Leg press hack squat AF 2916, 8) Olympic flat bench indian, 9) Multi bench indian, 10) Flat bench, 11) Hyper extension, 12) Dips, 13) Seated Calf, 14) Dumbbell Rack, 15) Plate Tree, 16) Dumbbell indian, 17) Plate indian, 18) Olympic Bar 7 fit, 19) Olympic Bar 5 fit, 20) Olympic Bar 4 fit, 21) Olympic Bar 3 fit, 22) Olympic bar Ez 4fit, 23) Olympic Bar 3 fit, 24) Bicep bench, 25) Short Bar 101, 26) Curl Bar 020 , 27) ARC Handle Pull Bar 108, 28) Arc Handle KEEP 114, 29) Shoulder Rope Single, 30) Lat Bar 17, 31) Smith machine, 32) Gym ball, 33) 5mm yoga mat.
Providing and fixing Jacuzzi of the following as directed and specified complete: i) ARTIZE QUADRO; 190 X 90 X 50 SUPERIOR WHIRLPOOL; MODEL- AWL-WHT-SUPR190X90, ii) LEXA AND QUADRO FRONT PANEL SUITABLE FOR LEXA AND QUADRO BATHTUBE; MODEL- AWA-GRY-FP190X, iii) QUADRO SIDE PANEL SUITABLE FOR BUILT-IN BATHTUB & WHIRLPOOL.