| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 CrAccepted-AOC KANNUR | KERALA | 670001 | ₹23.3 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹24.6 CrRejected-AOC C O VOLTAS LIMITED SPARE PARTS DEPOT OLD HUTMENT COLONY NCL NIGAHI SINGRAULI M P 486884 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486884 | ₹24.6 Cr | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹26.8 CrRejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹26.8 Cr | L3 | Rejected-Finance L3 bidder |
Tender Value
₹25.9 Cr
EMD Value
₹5 L
Closing Date
23 Sept 2022, 3:00 pmClosed
Managing Director
KITCO Ltd MM Gardens, Church landing Road Pallimukku, Ernakulam
Development of Government Medical College Kasaragod Additional works Part A Electromechanical Packages for Hospital Block Electrical HVAC Elevator System ELV etc
2022_KITCO_503173_1
HFWD/KITCO/EL/04/2022
Open Tender
Electrical Works
360 days
Kasaragod
As per ITB
8 documents required · 8 mandatory
₹17,700
Yes
₹5 L
Yes
KITCO Ltd
20 Jul 2023
12 Aug 2022
26 Sept 2022
12 Aug 2022
23 Sept 2022
22 Aug 2022
12 Aug 2022 - 17 Aug 2022
19 Aug 2022
Amount
HT EQUIPMENTS
od50492/2022_2023 : 11kV RMU panel (Extensible Type) - Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated,Ring Main Unit indoor type with 2 nos motorised Load break switch as incomer and 2 no motorized VCB (fully rated earth switch) with fully encapsulated vacuum interrupter panel as outgoings, 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators,battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a existing foundation. The RMU must be both side extensible type .The rate quoted shall be inclusive mounting accessories, hoisting to its location, assembling of units, lining up, necessary civil works as per requirement and standards, bolting the units and checking all control wiring complete as per single line diagram, technical specification. The LBS, VCB shall be enabled with VIPS and LBS shall be equipped with Fault passage indicator.
od56120/2022_2023 : 630 KVA 11KV Dry type transformer Design, fabrication, supply , Installation , testing and commissioning of 630 kVA, 11kV/433V 3 Ph, 50 Hz, dry type, vector DYN-11, copper wound, Class F insulation, indoor distribution Transformer with IP23 enclosure. The transformer shall connected Delta on HV side and Star on LV side with On Load Tap Changer in steps of + 5% to - 15% in steps of 2.5% with RTCC and AVR. The transformer shall have neutral CT with suitable enclosure on earthed star point with connector for connection to low set earth fault relay, winding temperature alarm and trip as per Single line diagram, The enclosure shall be IP 23 protection and having HV cable box suitable for termination of HT XLPE cable and LV chamber suitable for termination of cables and complete with all standard fittings and accessories etc including necessary louvers with cooling fan/duct as required complete and as per specifications attached in all respects as required and necessary control cabling for alarm, tripping , indication, necessary civil works as per requirement and standards as required. The rate shall be inclusive of all materials, lead, lift, etc. complete as per single line diagram , particular specification. Standard fittings as per IS:2026 and IS 11171 : 1985. Losses , impedance shall be as per ECBC 2017
LT PANEL BOARDS AND ACCESSORIES
od85030/2022_2023 : Supply, Installation, Testing and commissioning of Outdoor Lighting Panel (ODP) cubicle type, made out of thermoplastic UV resistant enclosure, totally enclosed, IP65, free standing, floor mounting, dust and vermin proof, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessary internal wiring , suitable spreader etc. certification for similar panels (required for short circuit rating, temperature rise and IP classification) shall be submitted .Panel shall be with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification. INCOMER : 40 A, FP, 25kA, MCCB with adjustable thermal magnetic release with OL , SC protection - 1 No, BUSBAR : 40A TPN busbars of high conductivity electrolytic quality copper alloy INSTRUMENTS : 4A, C curve SP MCB - 3 Nos, RYB indication lamp, LED type - 1 Set, timer clock with 40A FP contactor having an astronomical 365 day timer clock with Sunrise/Sunset tracking- 1 Nos OUTGOINGS : 16 A C Curve FP 100mA , RCCB+MCB-4 Nos.
DG SET AND ACCESSORIES
od85428/2022_2023 : Supply, Installation, Testing and Commissioning of 250 kVA prime rated D.G Set with acoustic enclosure and Control panel, protection and digital metering,controls and interlocks,CTs and transducers for all metering and protection and suitable MCCB , Contactor with O/L,O/V,U/V,Negative sequence, Low set Earth Fault,& REF differential relay with fuel shutoff,Overspeed protection etc , including ant vibration mountings, thermal insulated exhaust silencer and exhaust pipe (pipe measured separately) conforming to latest environment protection regulations for emission and noise levels complete with , water / coolant cooled, (radiator type) four stroke, electric start , 250 kVA prime rating, brushless, selfexcited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5%Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to IS/IEC 60034-1. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing, necessary civil works as per requirement and standards. Fuel tank for 8 hours suitable continuous operation,fuel piping from fuel tank to Engine, Residential silencer, LV chamber suitable for termination of cable etc as required and as per technical specifications.The work should be as per Central Pollution control board standards applicable at the time of delivery.
od85431/2022_2023 : Supply, Installation, Testing and Commissioning of 380 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks,CTs and transducers for all metering and protection and suitable MCCB , Contactor with O/L,O/V,U/V,Negative sequence, Low set Earth Fault,& REF differential relay with fuel shutoff,Overspeed protection etc , including ant vibration mountings, thermal insulated exhaust silencer and exhaust pipe (pipe measured separately) conforming to latest environment protection regulations for emission and noise levels complete with , water / coolant cooled, (radiator type) four stroke, electric start , 380 kVA prime rating, brushless, selfexcited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5%Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to IS/IEC 60034-1. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing necessary civil works as per requirement and standards. Fuel tank for 8 hours suitable continuous operation,fuel piping from fuel tank to Engine, Residential silencer, LV chamber suitable for termination of cable etc as required and as per technical specifications.The work should be as per Central Pollution control board standards applicable at the time of delivery.
od85433/2022_2023 : Supply, Installation, Testing and Commissioning of 625 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks,CTs and transducers for all metering and protection and suitable ACB with O/L,O/V,U/V,Negative sequence, Low set Earth Fault,& REF differential relay with fuel shutoff,Overspeed protection etc , including ant vibration mountings, thermal insulated exhaust silencer and exhaust pipe (pipe measured separately) conforming to latest environment protection regulations for emission and noise levels complete with , water / coolant cooled, (radiator type) four stroke, electric start , 625 kVA prime rating, brushless, selfexcited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5%Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to IS/IEC 60034-1. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing, necessary civil works as per requirement and standards. Fuel tank for 8 hours suitable continuous operation,fuel piping from fuel tank to Engine, Residential silencer, LV chamber suitable for termination of cable etc as required and as per technical specifications.The work should be as per Central Pollution control board standards applicable at the time of delivery.
od85486/2022_2023 : Supply, Fabrication and Installation of exhaust stack for DG with mild steel exhaust pipe (minimum 150mm dia) complete with fittings, cutting, bending, welding and applying a priming coat of approved steel primer and finishing with Epoxy paint (two or more coats) at all locations prepared and applied as required , approved by the Engineer Incharge.
od85487/2022_2023 : Supply, Fabrication and Installation of exhaust stack for DG with mild steel exhaust pipe (minimum 150mm dia) complete with fittings, cutting, bending, welding, 75 mm thick 96 kg/ cu.m density, mineral wool or equal insulation covered with 24 SWG. Aluminium sheet cladding etc. complete as required , approved by the Engineer Incharge.
od85488/2022_2023 : Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and finishing with Epoxy paint (two or more coats) at all locations prepared and applied using structural steel etc. as required, all complete
UPS AND ACCESSORIES
od115258/2022_2023 : Supply Installation Testing, Commissioning of not less than 200KW Modular Rack with 25KW X 6 No modules in N+1 configuration, suitable for future expansion upto 200kW with Input Voltage 415V, output voltage 415V, Input power factor 0.99 Thdi < 3%,including suitable size output isolation transformer, Efficiency at Double conversion mode 96%, IP20, with 15 mins battery back up and with all necessary Battery Breaker, Rack, Interlinks, control Cables, cables between UPS, Battery. Batteries shall be as per technical specifcation attached.
CABLES AND ACCESSORIES
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
10.6.4 : Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
od45229/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.3C 6 sqmm Cu
od45230/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.3C 4 sqmm Cu
od45231/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3C 10 sqmm Al
od45232/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 16 sqmm Al
od45233/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 35 sqmm Al
od45235/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 70 sqmm Al
od45236/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 120 sqmm Al
od45237/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 185 sqmm Al
od45238/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 240 sqmm Al
od45266/2022_2023 : Supply of 4C 10 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date
od45311/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx400sq.mm Al Cable
od45351/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 50 Sq.mm Al
od45356/2022_2023 : Supply of 4C 25 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
od45563/2022_2023 : Supply of 12C x 2.5 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor Control cable conforming to IS 7098 (Part 1) amended upto date.
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
od45631/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 12C 2.5 sqmmCu
od46598/2022_2023 : Supply and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc as required. and instructed by engineer in charge 1C x 120 sq.mm CU Flexible
od46660/2022_2023 : Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Single core Copper conductor cable of 1.1 KV grade as required. 1C x 120 sq.mm Cu cable
od46692/2022_2023 : Supplying and making end termination with brass compression gland and Cu lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required. 3C X 4 sq.mm
od46709/2022_2023 : Supplying and making end termination with brass compression gland and Cu lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required. 3C X 10 sq.mm
od46710/2022_2023 : Supplying and making end termination with brass compression gland and Cu lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required. 3C X 6 sq.mm
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
4.6.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness.
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.6.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 50 mm depth X 2.0 mm thickness
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
od85550/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 95 Sq.mm AL
od113451/2022_2023 : Supply of following 3C X 300 sq.mm sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade(earthed) conforming to IS 7098 amended upto date
WIRING AND ACCESSORIES
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
od42699/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
od42787/2022_2023 : Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
od85238/2022_2023 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
od85271/2022_2023 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.
od85279/2022_2023 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
MCB AND MCB DISTRIBUTION BOARDS
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
90.11.1.13 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - three phase double cover (IP 42/43)
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.21 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.24.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
od57536/2022_2023 : Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release in existing cubicle panel board or VDB including drilling holes in cubicle panel, making connections, etc. including all accessories as required.16A - 100A 16kA FP TM, MCCB
od57928/2022_2023 : Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release in existing cubicle panel board or VDB including drilling holes in cubicle panel, making connections, etc. including all accessories as required.125A 16kA FP TM, MCCB
od58192/2022_2023 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “D” curve,miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole and neutral
od58193/2022_2023 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current 100milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63amps
od58194/2022_2023 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current 100milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
od58303/2022_2023 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, " D" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
od58304/2022_2023 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, " C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
od58340/2022_2023 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, " C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
od58368/2022_2023 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “D” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole
od58446/2022_2023 : Supply, Installation, Testing , Commissioning of 63 A FP MCB isolator in CRCA sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete
od58447/2022_2023 : Supply, Installation, Testing , Commissioning of 100 A FP MCB isolator in CRCA sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete
od58448/2022_2023 : Supply, Installation, Testing , Commissioning of 125 A FP MCB isolator in CRCA sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete
od58528/2022_2023 : Supplying and fixing Cable End Boxes (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 volts, on surface/ recess, complete with testing and commissioning etc.(For VDB with MCCB as incomer)
od58539/2022_2023 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 12 way, Double door TPN MCBDB
od58541/2022_2023 : Supply installation testing commissioning of 415 V ,400A ,FP, MCCB isolator in CRCA sheet steel enclosure including Busbar, RYB indication,spreaders, handle ,door opening interlocking, ample space for cable termination etc as required neccessary to complete installation
od58542/2022_2023 : Supply, Installation, Testing , Commissioning of 32 A FP MCB isolator in CRCA sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
LIGHT FIXTURES AND FANS
od46957/2022_2023 : Supply of 40W (+/-10%),4ft, High efficient LED batten surface/wall mounted with Aluminium alloy housing and polycarbonate diffuser.IP20, CRI 80, Temperature range-0 to 45 DegC, Power factor 0.9,THD<10%, Surge protection 2 kV, 50000 or above burning hours as per L70 Criteria, Inbuilt electronic driver, luminaire efficacy not less than 120 lm/W as per LM79 including all accessories necessary as required to complete installation
od46958/2022_2023 : Supply of 18W(+/-10%) ,4ft, High efficient LED batten surface/wall mounted with Aluminium alloy housing and polycarbonate diffuser.IP20, CRI 80, Temperature range-0 to 45 DegC, Power factor 0.9, THD<10%, Surge protection 2kV, 50000 or above burning hours as per L70 Criteria, Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79 including all accessories necessary as required to complete installation
od46962/2022_2023 : Supply of 10W(+/-10%),2ft, High efficient LED batten surface/wall mounted with Aluminium alloy housing and polycarbonate diffuser.IP20, CRI 80, Temperature range-0 to 45 DegC, Power factor 0.9, THD<10%, Surge protection 2kV, 50000 or above burning hours as per L70 Criteria, Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79, including all accessories necessary as required to complete installation
od47954/2022_2023 : Supply of 9W(+/-10%), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. CRI 80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Power factor 0.9, Surge protection-2 kV,Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79, including all accessories necessary as required to complete installation
od48200/2022_2023 : Supply of 18W(+/-10%), High efficient surface mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. CRI 80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Powerfactor 0.9, Surge protection-2 kV,Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79, including all accessories necessary as required to complete installation
od48201/2022_2023 : Supply of 50W , High efficient LED Flood light luminaire with aluminium die cast housing , High transmittivity polycarbonate diffuser. CRI 80, IP66, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life.THD<10%, Powerfactor 0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy 100 lm/W including all accessories necessary as required to complete installation
od48202/2022_2023 : Supply of 36W (+/-10%) , High efficient recess mounted 2 x 2 LED luminaire with steel housing , High transmittivity polycarbonate diffuser. CRI 80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs as per L70 criteria .THD<10%, Power factor 0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy not less than 110 lm/W as per LM79 , including all accessories necessary as required to complete installation
od48203/2022_2023 : Supply of 40W (+/-10%) , High efficient recess mounted 2 x 2 clean room LED luminaire with CRCA housing , High Efficiency Translucence (HET) diffuser. CRI 80, IP65 from front , Ambient temp-0 to 45DegC, 50,000 hrs as per L70 criteria .THD<10%, Power factor 0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy not less than 110 lm/W including all accessories necessary as required to complete installation
od48204/2022_2023 : Supply of 18W(+/-10%), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. CRI 80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs as per L70 criteria.THD<10%, Powerfactor 0.9, Surge protection-2 kV,Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79 including all accessories necessary as required to complete installation
od81971/2022_2023 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote (with remote holder) or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
od85163/2022_2023 : Supply of 450mm sweep heavy duty exhaust fan in die cast aluminium with metal grill/ louvers working on 230 V AC supply complete with all accessories as required.
od85164/2022_2023 : Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal body with grill/ louvers working on 230 V AC supply complete with all accessories as required.
od85218/2022_2023 : Supply of 400 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.
EARTHING, LIGHTNING PROTECTION AND SAFETY EQUIPMENT
od55467/2022_2023 : Supplying and laying 32 mm X 6 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt , spring washer spaced at 50mm)
od55633/2022_2023 : Supplying and laying 50 mm X 10 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt , spring washer spaced at 50mm)
od55717/2022_2023 : Providing and fixing 32 mm X 6 mm copper strip on surface ,recess or in tray for connections etc.as required.
od55759/2022_2023 : Providing and fixing 50 mm X 10 mm copper strip on surface ,recess or in tray for connections etc.as required.
od55820/2022_2023 : Providing and fixing 25 mm X 5 mm copper strip on surface , recess or in tray for connections etc.as required.
5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
od55875/2022_2023 : Earthing with G.I. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories,and providing masonry enclosure with CI/MS cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set
od55916/2022_2023 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
od55941/2022_2023 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for Sheet roof with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
od55943/2022_2023 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
od55947/2022_2023 : Providing and fixing of test joint suitable for hot dipped galvanized steel tape 32 mm x 6mm and 8mm dia solid round aluminium conductor conforming to the requirements according to (IS/IEC 62305) with all accessories complete as required
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.
od55973/2022_2023 : Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone , anchors etc . as required per IEC 62305-3 4Mtr Airterminal
od55974/2022_2023 : Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone ,anchors etc . as required per IEC 62305-3 2Mtr Airterminal
od55976/2022_2023 : Providing and laying earth connection with 4.00 mm dia copper wire including all accessories, connections ,excavation and re-filling as required.
od56349/2022_2023 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .
od56350/2022_2023 : Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound
od56351/2022_2023 : Supply and fixing of First aid box
od56352/2022_2023 : Supplying of Rubber hand gloves suitable for 11 KV.
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
EXTERNAL LIGHTING
90.15.3.5 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.3.6 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters
SOLAR
od84556/2022_2023 : Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline Half-cut solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 500 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box , Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections , Interconnections by supplying , fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying , fixing of necessary channel/conduit lugs and other accessories etc. as required. (Measurement unit shall be KWp) (Note: unit "each" means "kWP")
HVAC EQUIPMENTS
od238812/2021_2022 : Supply, Installation, Testing, Commissioning of 18 HP (minimum capacity Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).
od238813/2021_2022 : Supply, Installation, Testing, Commissioning of 28 HP (minimum capacity ) Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).
od238814/2021_2022 : Supply, Installation, Testing, Commissioning of 30 HP (minimum capacity ) Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).
od238815/2021_2022 : Supply, Installation, Testing, Commissioning of 32 HP (minimum capacity )Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).
od88620/2022_2023 : Supply, Installation ,testing and commissioning of 34 HP Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).
od238816/2021_2022 : Supply, Installation, Testing, Commissioning of 40 HP (minimum capacity )Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).
od238817/2021_2022 : Supply, Installation, Testing, Commissioning of 50 HP (minimum capacity )Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).
od238818/2021_2022 : Supply, Installation, Testing, Commissioning of 56 HP (minimum capacity )Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).
od238819/2021_2022 : Supply, Installation , testing and commissioning of the following capacity VRF compatible Air handling units with AHU Kit with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan, as per specifications complete with cordless remotes, power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, PVC drain pipe connections(upto 5 m) with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc., filter section shall be 99% efficiency down to 3 micron MERV 13 filters complying to ASHRAE 52.2 required starter panel and control panel , structural supports , safety devices .power/control cabling from power supply, etc. complete in all respects as per technical specifications.. 25TR (10000 CFM) - 50 mm of WG ESP
od238820/2021_2022 : Supply, Installation ,testing and commissioning of minimum 11TR(4400 CFM) capacity Double skin, sheet metal VRF compactable AIR-HANDLING UNIT inculding AHU kit, all accessories as required as per technical specifications complete with outlet volume control dampers, canvas connections, filter section shall be 99% efficiency down to 3 micron MERV 13 filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, power wiring and power/control cabling(indoor to outdoor),digital thermostat with required control wiring, required starter panel and control panel , structural supports for fixing IDU, safety devices etc. the following minimum capacity and the cooling coil (min 4 rows), suitable for three phase 440V supply, complete in all respects as per technical specifications.(Minimum External Static Pressur 50 mmwc )
od238821/2021_2022 : Supply, Installation , testing and commissioning of the 8 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.
od238822/2021_2022 : Supply, Installation , testing and commissioning of the 6 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.
od238823/2021_2022 : Supply, Installation , testing and commissioning of the 5 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.
od238824/2021_2022 : Supply, Installation , testing and commissioning of the 4 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.
od238825/2021_2022 : Supply, Installation , testing and commissioning of the 3 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.
od238826/2021_2022 : Supply, Installation , testing and commissioning of the 2 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.
od238828/2021_2022 : Supply, Installation ,testing and commissioning of 2 TR minimum capacity VRF compatible indoor evaporative units Cassette type with cordless remote, of following minimum capacities suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, electrical cabling from power plug, structural supports, vibrations isolators etc. complete in all respects as per the technical specifications.
od238829/2021_2022 : Supply, Installation ,testing and commissioning of 1.5 TR minimum capacity VRF compatible indoor evaporative units Cassette type with cordless remote, of following minimum capacities suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, electrical cabling from power plug, structural supports, vibrations isolators etc. complete in all respects as per the technical specifications.
od238830/2021_2022 : Supply, Installation ,testing and commissioning of 1 TR minimum capacity VRF compatible indoor evaporative units Cassette type with cordless remote, of following minimum capacities suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, electrical cabling from power plug, structural supports, vibrations isolators etc. complete in all respects as per the technical specifications.
od238831/2021_2022 : Supply, Installation ,testing , commissioning of 2 TR minimum capacity VRF compatible Hi wall air conditioning unit of following capacity complete with suitable capacity drive motor, all associated electrical works including power/control cabling (indoor to outdoor), cordless remote,high lift condensate drain pump suitable for single phase 230 V supply etc. complete in all respects as per the technical specifications.
od238832/2021_2022 : Supply, Installation ,testing , commissioning of 1.5 TR minimum capacity VRF compatible Hi wall air conditioning unit of following capacity complete with suitable capacity drive motor, all associated electrical works including power/control cabling (indoor to outdoor), cordless remote,high lift condensate drain pump suitable for single phase 230 V supply etc. complete in all respects as per the technical specifications..
od238833/2021_2022 : Supply, Installation ,testing , commissioning of 1 TR minimum capacity VRF compatible Hi wall air conditioning unit of following capacity complete with suitable capacity drive motor, all associated electrical works including power/control cabling (indoor to outdoor), cordless remote,high lift condensate drain pump suitable for single phase 230 V supply etc. complete in all respects as per the technical specifications.
od238835/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/4" ) 44.4mm
od238837/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 5/8" ) 41.3mm
od238839/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/2" ) 38.1mm
od238841/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/8" ) 34.9mm
od238842/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/4" ) 31.8mm
od238843/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/8" ) 28.6mm
od238844/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 " )25.4mm
od238846/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 7/8" ) 22.2mm
od238849/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/4" )19.05mm
od238850/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 5/8" )15.88mm
od238852/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1/2" )12.7mm
od238853/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/8" ) 9.52mm
od238854/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Soft Copper Pipe 18Guage with 19mm thick Insulation ( 1/4" ) 6.35mm
od238856/2021_2022 : Supply, installation testing and commissioning of 1.5 TR minimum capacity Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 3 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation as per specification interconnecting indoor , outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports finished with 7 mils factory laminated treated fibre glass cloth, necessary power/control cabling, suitably supported on trays/ split clamps etc., first charge refrigerant gas R32/R410A/R407C, cordless remote etc complete in all respects as per the technical specifications.
od238857/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1700 CFM -20 mm of WG ESP
od238858/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1400 CFM -20 mm of WG ESP
od238859/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1200 CFM -20 mm of WG ESP
od238860/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1100 CFM -20 mm of WG ESP
od238861/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1000 CFM -20 mm of WG ESP
od238862/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 900 CFM -20 mm of WG ESP
od238863/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 800 CFM -20 mm of WG ESP
od238864/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 700 CFM -20 mm of WG ESP
od238865/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 600 CFM -20 mm of WG ESP
od239037/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single phase direct driven motor of following capacity for exhaust application with applicable Starter /Starter panel required power cabling from single point power supply,required structural supports ,vibration isolator ,all other accessories etc.complete in all respects as per the technical specifications: 500 CFM -20 mm of WG ESP
od238866/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 400 CFM -20 mm of WG ESP
od238867/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 200 CFM -15 mm of WG ESP
od238868/2021_2022 : Supply, installation, testing and commissioning of PVC drain pipe of 6Kg/Sq.cm of suitable dia connecting the drain pan of the indoor units with necessary U-traps, elbows, fittings etc. to nearest drain point, with insulated with 9 mm thick closed cell elastomeric class 0 insulation with 7 mils factory laminated glass cloth as per specification required pipe fittings and accessories like bends, tees, reducers, supports, clamps, suitably supported on trays, clamps etc. complete in all respects as per the technical specifications.
AIR DISTRIBUTION SYSTEM
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 0.63 mm sheet duct 24 G
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 0.80 mm sheet duct – 22 G
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 1.00 mm sheet duct – 20 G
16.12.1.4 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 1.20 mm sheet duct – 18 G
od238870/2021_2022 : Air-Distribution Network for Supply air, Return air,Exhaust Air,Fresh Air made out of suitable gauge Aluminum sheet with suitable gasketing , special sealing , perforated grilles, associated accessories, supports etc. for MRI/CT room application and as per relevant SMACNA standards etc complete in all respects as per the technical specifications.
16.23.1 : Supplying and fixing of 19mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required with R value less than 0.6. complete in all respects as per the technical specifications.
16.21.1 : Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3, with 25 mm X 25 mm Gl section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 16 <br> <br>Acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3
od354475/2021_2022 : DSR - 16.22 Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. 50 mm thick resin bonded glass wool having density of 32 kg/m³
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od238899/2021_2022 : DSR 16.16 Supplying , fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
od353834/2021_2022 : Supply, Installation , testing and commissioning of Aluminium extruded exhaust air louvers with damper, bird screen etc. complete in all respects as per technical specifications.
od238901/2021_2022 : Supply, Installation , testing and commissioning of Aluminium extruded fresh air louvers with fresh air damper,bird screen etc. complete in all respects as required by the technical specifications..
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
od238920/2021_2022 : Supply, Installation ,testing , commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for air distribution Networks , complete in all respects as per the technical specifications.
od238918/2021_2022 : Supply, Installation ,testing and commissioning of Under-deck insulation of exposed roof using Class " O" Nitrile rubber insulation of 19mm thickness, anti microbial insulation and stuck to the roof using suitable adhesives, tapes etc. complete in all respects as per technical specifications , manufacturer's recommendation.
od238919/2021_2022 : Air curtain Supply, installation, testing and commissioning of air curtains of width 1.0 m (15 amps female socket will be provided by Client outside the compartment. Supplier shall draw connection from the socket to air curtain using mail socket and cable) The system shall include all accessories including motors, blowers, door opening sensors, asscoiated electrical and control cabling etc. complete in all respects as per technical specifications.
ELEVATOR SYSTEM
od239085/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 20 Pax (1360 Kg) Hospital elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST ) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The traction motor(IE3 efficieny grade or better ) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way , the Drives shall meet the requirements of IEEE 519/2014. complete as per technical specification. Having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides, 2 mm fluted SS sheet flooring as applicable in accordance of following details:-5 stops , 5 openings and entrance , exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 2400mm (width) x 3100mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) ,door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications
od239364/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 15Pax (1020 Kg) Hospital elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The traction motor(IE3 efficieny grade or better ) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way , the Drives shall meet the requirements of IEEE 519/2014. Having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides,2 mm fluted SS sheet flooring as applicable in accordance of following details:-5 stops , 5 openings and entrance , exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 2200mm (width) x 3000mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) , door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications
od239428/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 26 Pax (1768 Kg) Hospital elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. Except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor(IE3or better efficiency of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides, 2 mm Fluted SS sheet flooring as applicable in accordance of following details:-5 stops , 5 openings and entrance , exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 2650mm (width) x 3400mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) , door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications
od239488/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 20 Pax Hospital elevator (1360 Kg) (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The traction motor(IE3 efficieny grade or better ) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way , the Drives shall meet the requirements of IEEE 519/2014. Having automatic centre/side opening SS door, stainless steel car enclosure provided with stainless steel handrails on two sides, 2 mm fluted SS sheet flooring as applicable in accordance of following details:-4 stops , 4 openings and entrance , exit at same side and suitable for travel height of 12.6 mtrs. (Shaft Size 2400mm (width) x 3000mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) , door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications
od239506/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 20 Pax (1360 Kg) Hospital elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. Except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The traction motor(IE3 efficieny grade or better ) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way , the Drives shall meet the requirements of IEEE 519/2014. Having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides, 2 mm fluted SS sheet flooring as applicable in accordance of following details:-4 stops , 4 openings and entrance , exit at same side and suitable for travel height of 12.6 mtrs. (Shaft Size 2400mm (width) x 3100mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) , door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications
od239514/2021_2022 : Design, fabrication, supply, Installation ,Testing and Commissioning of electric traction type with machine roomless type , Stainless steel 250Kg capacity Dumb Waiter elevator, (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of minimum 0.3 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, LED type emergency light, reverse phase relay on controller, LCD/LED car positions and direction indication in car and landings. at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor(IE3or better efficiency) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having vertical bi-parting opening SS door with handles, stainless steel car enclosure as applicable in accordance of following details:-5 stops , 5 openings and entrance , exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 1600mm (width) x 1200mm (depth) ) with door opening of 1000mm. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications
od239521/2021_2022 : Design, fabrication, supply, Installation ,Testing and Commissioning of electric traction type with machine roomless type , Stainless steel 250Kg capacity Dumb Waiter elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of minimum 0.3 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, LED type emergency light, reverse phase relay on controller, LCD/LED car positions and direction indication in car and landings. at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor(IE3or better efficiency) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having vertical bi-parting opening SS door with handles, stainless steel car enclosure as applicable in accordance of following details:-2 stops , 2 openings and entrance , exit at same side and suitable for travel height of 4.2 mtrs. (Shaft Size 1700mm (width) x 1200mm (depth) ) with door opening of 1000 mm. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications
od242825/2021_2022 : Statutory fees associated with elevator installation , licensing (lift inspection , Lift insurance)
STRUCTURED CABLING COMPONENTS
od175316/2021_2022 : Supply, installation, testing and commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site to complete the work as per technical specification
od177695/2021_2022 : Supply, installation, testing and commissioning of U/UTP cable - Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site to complete the work as per technical specification
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
od175324/2021_2022 : Supply and installation of concealed metal back box with all accessories required at site to complete the work as per technical specification
od175328/2021_2022 : Supply and installation of PVC backbox with all accessories as required at site to complete the work as per technical specification
od175332/2021_2022 : Supply, installation, testing and commissioning of Category 6 information Outlet, RJ 45 with all accessories required at site including termination to complete the work as per technical specification
od177707/2021_2022 : Supply, installation, testing and commissioning of Category 6A Information Outlet, RJ 45 with all accessories required at site including termination to complete the work as per technical specification
od175335/2021_2022 : Supply, installation, testing and commissioning of Category 6 24 port patch panel, fully loaded with I/Os, including termination as required at site complete the work as per technical specification
od177723/2021_2022 : Supply, installation, testing and commissioning of Category 6A 24 port patch panel, fully loaded with I/Os, including termination as required at site to complete the work as per technical specification
od185459/2021_2022 : Supply, installation, testing and commissioning of 50 port Category 3 voice patch panel, fully loaded, including termination with all accessories required at site to complete the work as per technical specification
od175336/2021_2022 : Supply and installation of single or dual shuttered faceplate with all accessories required at site to complete the work as per technical specification
od175337/2021_2022 : Supply, installation, testing and commissioning of Category 6 - 2m patch cord with end termination and all accessories required at site to complete the work as per technical specification
od177852/2021_2022 : Supply, installation, testing and commissioning of Category 6A - 2m patch cord with end termination and all accessories required at site to complete the work as per technical specification
od178259/2021_2022 : Supply, installation, testing and commissioning of Category 6A - 1m patch cord with end termination and all accessories required at site to complete the work as per technical specification.
od180546/2021_2022 : Supply, Installation, Testing and Commissioning of 50 pair telephone riser cable, including termination, with all accessories required at site complete as per technical specifications
od175339/2021_2022 : Supply, installation, testing and commissioning of 6 core, single mode, OS2, fibre optic indoor/outdoor cable through existing cable trays or pipes including termination with all accessories required at site to complete the work as per technical specification
od175340/2021_2022 : Supply, installation, testing and commissioning of 24 port LC single mode rack mount fiber enclosure LIU, fully loaded (with LC pigtails / adapters / couplers / splice tray / splice holder, etc) with all accessories required at site to complete the work as per technical specification
od175341/2021_2022 : Supply, installation, testing and commissioning of fiber path cord - 3 meter, LC-LC, single mode, duplex with all accessories required at site to complete the work as per technical specification
od175342/2021_2022 : Supply and installation of PVC casing capping with all accessories required at site to complete the work as per technical specification
od175343/2021_2022 : Supply and installation of covered unperforated hot dipped galvanised iron cable tray of size - 300 mm width x 50 mm depth x 1.6 mm thickness, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts and nuts and all accessories like bends, tees, reducers, etc required at site to complete the work as per technical specification
od175344/2021_2022 : Supply and installation of 32mm HDPE Pipe, ISI marked, along with all accessories like socket, bend, couplers, complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required at site to complete the work as per technical specification
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
od185460/2021_2022 : Supply, installation, testing and commissioning of 600 pair MDF with krone modules, jumper wires, including termination and all other accessories required at site to complete the work as per technical specification
od178863/2021_2022 : Supply, installation, testing and commissioning of 27U floor mount network rack, size - 600 x 800mm, along with all necessary hardware and accessories required at site to complete the work as per technical specification
od175346/2021_2022 : Supply, installation, testing and commissioning of 42U floor mount network rack, size - 800 x 1000mm, along with all necessary hardware and accessories required at site to complete the work as per technical specification
IP-EPABX
od175309/2021_2022 : Supply, installation, testing and commissioning of IP based EPABX system having capacity of 600 analog extensions and 50 IP extensions, 2 PRI, 60 channel SIP trunk, scalable up to 1500 extensions, including a desktop based operator console, with all hardware, software, licenses, cabling and other accessories required at site to complete the work as per technical specification
IP SURVEILLANCE
od175314/2021_2022 : Supply, installation, testing and commissioning of 2MP varifocal motorised IP camera, PoE, IP66 rated with all accessories required at site to complete the work as per technical specification
od175321/2021_2022 : Supply, installation, testing and commissioning of 128 channel Network Video Recorder, RAID 5, SAS/Enterprise HDDs for 30 days archiving, including a desktop with all hardware, software, cabling and other accessories as required at site to complete the work as per technical specification.
od185461/2021_2022 : Supply, installation, testing and commissioning of 55" commercial display, 24/7 with HDMI and USB ports with all accessories required at site to complete the work as per technical specification
ATTENDANCE SYSTEM
od175313/2021_2022 : Supply, installation, testing and commissioning of Attendance machine, fingerprint and proximity card based, PoE, with all hardware, software, cabling and other accessories required at site to complete the work as per technical specification
PUBLIC ADDRESS AND EVACUATION SYSTEM
od175312/2021_2022 : Supply, installation, testing and commissioning of 2 core 1.5 sq.mm speaker cable, FRLS, with all accessories required at site to complete the work as per technical specification
od175318/2021_2022 : Supply, installation, testing and commissioning of 6W metal Ceiling Speaker with all accessories required at site to complete the work as per technical specification
od175322/2021_2022 : Supply, installation, testing and commissioning of 6W Wall mount Speaker with all accessories required at site to complete the work as per technical specification
od175327/2021_2022 : Supply, installation, testing and commissioning of 480W Power Amplifier with all accessories required at site to complete the work as per technical specification
od175331/2021_2022 : Supply, installation, testing and commissioning of Public Address and Evacuation system Controller capable of managing up to 18 individual zones with BGM, announcement, automatic emergency message facility, integration with Fire alarm system and all accessories as required at site to complete the work as per technical specification
RODENT REPELLENT SYSTEM
od175311/2021_2022 : Supply, installation, testing and commissioning of Rodent repellent system including main console, transducers, cabling and all accessories required at site to complete the work as per technical specification
ACTIVE DEVICES
od175315/2021_2022 : Supply, installation, testing and commissioning of 24 port stackable Switch - Layer 2, 24 x 10/100/1000Base-TX ports with 2 x 10G SFP+ ports including all necessary hardware, software and accessories required at site to complete the work as per technical specification
od175323/2021_2022 : Supply, installation, testing and commissioning of 24 port PoE+ stackable Switch - Layer 2, 24 x 10/100/1000Base-TX PoE+ ports with 2 x 10G SFP+ ports including all necessary hardware, software and accessories as required at site to complete the work as per technical specification
od175325/2021_2022 : Supply, installation, testing and commissioning of 24 port Core switch - Layer 3, with minimum 22 x 10G SFP+ ports and 2 x 10G combo copper/SFP+ ports including all necessary hardware, software and accessories required at site to complete the work as per technical specification
od175329/2021_2022 : Supply, installation, testing and commissioning of 24 port PoE switch - Layer 2, 24 x 10/100/1000Base-TX PoE ports with 2 x 1G SFP ports including all necessary hardware, software and accessories as required at site to complete the work as per technical specification
od175330/2021_2022 : Supply, installation, testing and commissioning of 24 port Fiber Switch with minimum 20 x 1G SFP ports and 2 x 1G Copper ports including all necessary hardware, software and accessories as required at site complete as per technical specification
od179555/2021_2022 : Supply, installation, testing and commissioning of 10G SFP+ Transceiver module, LC type, for single mode fiber including all accessories required at site to complete the work as per technical specification
od179556/2021_2022 : Supply, installation, testing and commissioning of 1G SFP Transceiver module, LC type, for single mode fiber including all accessories required at site to complete the work as per technical specification
od175334/2021_2022 : Supply, installation, testing and commissioning of next generation Firewall for 1500 users with logs, monitoring, bandwidth management, etc. including hardware, software, licenses, security subscriptions, cabling and other accessories required at site to complete the work as per technical specification.
WI-FI ACCESS POINT
od175310/2021_2022 : Supply, installation, testing and commissioning of Wireless Access Point, Wi-Fi 6, dual-band, 2x2 MIMO, PoE, including mounting brackets and all accessories required at site to complete the work as per technical specification
UNIVERSAL MEP PROJECTS & ENGINEERING SERVICES LIMITED
Blue Star Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid