Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.3 L+₹73,200 (11.1%)Rejected-AOC RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹8.1 L+₹1.5 L (23.1%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹8.3 L+₹1.7 L (25.6%)Rejected-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹8.7 L+₹2.1 L (32.2%)Rejected-AOC 154 155 SUBATHU DISTT SOLAN 173206 | SOLAN | SOLAN | HIMACHAL PRADESH | 173206 | L5 | Rejected-AOC Other than lowest bidder |
| Sl No | Description | Qty | Unit | TARA ENTERPRISES L2 | Electromech Engineers L4 | M/S SUKHMANI ENGINEERS L6 | P S TRADERS L3 | M/s A.K. ENGINEERS L1 | M/S PARMOD KUMAR L5 | J B ELECTRICALS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out Soft/diseintegrated soil,Complete all as specified and directed by Engr-in-charge. | 54 | Cum | 90 ₹4,860 Lowest | 300 ₹16,200 | 225 ₹12,150 | 300 ₹16,200 | 200 ₹10,800 | 100 ₹5,400 | 200 ₹10,800 |
| 2.00 | Returning ,fillling in trenches,spreading ,levelling,watering and well ramming in layers not exceeding 25cm thick,Complete all as specified and directed by Engr-in-charge. | 33 | Cum | 110 ₹3,630 | 50 ₹1,650 Lowest | 50 ₹1,650 Lowest | 100 ₹3,300 | 100 ₹3,300 | 60 ₹1,980 | 200 ₹6,600 |
| 3.00 | Removing excavated material/ surplus soil and depositing where directed at a distence not exceeding 50mtr.at a level not exceeding 1.5 mtr from strting point,Complete all as specified and directed by Engr-in-charge. | 21 | Cum | 120 ₹2,520 | 50 ₹1,050 Lowest | 70 ₹1,470 | 80 ₹1,680 | 100 ₹2,100 | 60 ₹1,260 | 200 ₹4,200 |
| 4.00 | Supply lay/spread in trenches, river sand ,clean ,including spreading ,levelling ,punning for laying /cushioning of cables,Complete all as specified and directed by Engr-in-charge. | 18 | Cum | 400 ₹7,200 Lowest | 700 ₹12,600 | 786 ₹14,148 | 1,000 ₹18,000 | 1,000 ₹18,000 | 999 ₹17,982 | 600 ₹10,800 |
| 5.00 | Supply lay in replacement in trenches fly ash bricks, old size sub class “B” for cable protection,Complete all as specified and directed by Engr-in-charge. | 1,220 | Each | 5 ₹6,100 Lowest | 7 ₹8,540 | 14 ₹17,080 | 12 ₹14,640 | 8 ₹9,760 | 10 ₹12,200 | 13 ₹15,860 |
| 6.00 | Taking down of any type of cable of any size,Complete all as specified and directed by Engr-in-charge. | 430 | RM | 15 ₹6,450 | 73 ₹31,390 | 25 ₹10,750 | 50 ₹21,500 | 10 ₹4,300 | 5 ₹2,150 Lowest | 40 ₹17,200 |
| 7.00Supply, lay cable in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape , of following nominal cross sections, confirming to IS specifications :- | ||||||||||
| 7.01 | 3.5 Core 50 Sq.mm | 80 | RM | 225 ₹18,000 Lowest | 390 ₹31,200 | 436 ₹34,880 | 440 ₹35,200 | 230 ₹18,400 | 320 ₹25,600 | 345 ₹27,600 |
| 7.02 | 3.5 core 35 sq mm | 100 | RM | 275 ₹27,500 | 300 ₹30,000 | 325 ₹32,500 | 325 ₹32,500 | 200 ₹20,000 Lowest | 250 ₹25,000 | 265 ₹26,500 |
| 7.03 | 3.5 core 25 sq mm | 100 | RM | 325 ₹32,500 | 290 ₹29,000 | 267 ₹26,700 | 267 ₹26,700 | 190 ₹19,000 Lowest | 225 ₹22,500 | 195 ₹19,500 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
10 Jan 2026, 6:00 pmClosed
Sh K K Soni AE (Civ) AGE I R and D Manali
AGE I R AND D MANALI PIN 175103 PH 01902255014
REPAIR/ MAINT OF LT PANELS, CABLES AND STAND BY DG SETS AND OTHER MISC WORKS AT PALCHAN UNDER AGE (I) R AND D MANALI
2025_MES_745427_1
AGE(I)/MNL-83/2025-26
Open Tender
Civil Works
Item Rate
180 days
Palchan
As per NIT and tender documents
5 documents required · 5 mandatory
₹500
AGE (I) R AND D MANALI
₹19,000
Yes
2 Feb 2026
20 Dec 2025
12 Jan 2026
20 Dec 2025
10 Jan 2026
3 Jan 2026
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out Soft/diseintegrated soil,Complete all as specified and directed by Engr-in-charge.
Returning ,fillling in trenches,spreading ,levelling,watering and well ramming in layers not exceeding 25cm thick,Complete all as specified and directed by Engr-in-charge.
Removing excavated material/ surplus soil and depositing where directed at a distence not exceeding 50mtr.at a level not exceeding 1.5 mtr from strting point,Complete all as specified and directed by Engr-in-charge.
Supply lay/spread in trenches, river sand ,clean ,including spreading ,levelling ,punning for laying /cushioning of cables,Complete all as specified and directed by Engr-in-charge.
Supply lay in replacement in trenches fly ash bricks, old size sub class “B” for cable protection,Complete all as specified and directed by Engr-in-charge.
Taking down of any type of cable of any size,Complete all as specified and directed by Engr-in-charge.
Supply, lay cable in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape , of following nominal cross sections, confirming to IS specifications :-
3.5 Core 50 Sq.mm
3.5 core 35 sq mm
3.5 core 25 sq mm
3.5 core 16 sq mm
3.5 core 70 sq mm
Supply and fix 50 mm bore dia on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade , ISI marked ,of following sizes including necessery pipe ,fittings ,clamps, bolts , nuts etc., all as specified and as directed :-
M & L for cutting exisitng bitumenous road surfaces not more than 150 mm thick, removing for laying of pipes/cables, making good with PCC 1:3:6 type C1 20 mm graded aggregate to match with the adjustant surface. Note Excavation and earth work below 150 mm thick will be measured and paid under relevent items.(pcc will be measured and paid sepretly)
Taking down of any type of LT/ Bus bar panel of any size and any type as specified and directed by engineer in charge.
Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 240 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
OUTGOING SUPPLY :- (i) MCCB 63 Amps 16 KA 4 Pole with Adjustable thermal & fixed magnetic release 415 volts , 50Hz,=05 Nos., Make of MCCB:- L&T/ Siemens / Legrand/ Havells. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED
Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 450 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
OUTGOING SUPPLY :- (i) MCCB 100 Amps 16 KA 4 Pole with Adjustable thermal & fixed magnetic release 415 volts , 50Hz,=03 Nos., (ii) MCCB 63 Amps 16 KA 4 Pole with Adjustable thermal & fixed magnetic release 415 volts , 50Hz,=03 Nos., Make of MCCB:- L&T/ Siemens / Legrand/ Havells. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED
M&L Electrical Earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6.3 mm thick burried directly in ground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level , connected to Aluminum strip of size 25 X 3 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board / panel board , all as specified and shown in MES schedule Electrical Plate No:-5 of SSR Part I, including excavation and earth work in any type of siol , PCC 1 : 2 : 4 type C1 in chamber , RCC 1:2:4 type C1 40 mmthick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways,with 6 mm dia MS hook, Charcoal dust, salt , funnel for watering complete and testing the Earth resistence and writing on the chamber by paint all as specified and as directed.
TARA ENTERPRISES (BID ID -3519095)
P S TRADERS (BID ID -3526287)
Electromech Engineers (BID ID -3521543)
M/S PARMOD KUMAR (BID ID -3525951)
M/S SUKHMANI ENGINEERS (BID ID -3524800)
J B ELECTRICALS (BID ID -3525579)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_834696.xls
BOQ • 0.42 MB
TenderDocuments832526EM.pdf
Tender Documents • 0.94 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .