Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC TC 25664 RAJI OPP HOTEL AMRITHA THYCAUD THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹15.1 L+₹3.5 L (30.1%)Rejected-AOC | L2 | Rejected-AOC L2 bidder |
Tender Value
₹13.4 L
EMD Value
₹33,400
Closing Date
3 Jul 2020, 5:00 pmClosed
Assistant Executive Engineer
Office of the Assistant Executive Engineer, PWD Mechanical Sub Division, KLC, Thiruvananthapuram, Pin-695033
Providing air conditioning to the additional rooms for MLAs, Dormitory and Ladies Amenity areas based on the revised plan of proposed extension in the open terrace of Nila Block at MLA Hostel, Thiruvannathapuram
2020_Irrig_362169_1
1/AEEMECHKLC/ET/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
MLA Hostel, KLC
Please refer tender documents
6 documents required · 6 mandatory
₹2,800
Yes
online
₹33,400
Yes
16 Jan 2021
4 Jun 2020
7 Jul 2020
5 Jun 2020
3 Jul 2020
5 Jun 2020
Amount
Supply, Installation, Commissioning and Trial Run of 1.5 TR and 2 TR capacity 5 star inverter Split AC unit operating on single phase AC etc. complete including all taxes except GST. Make : ( OGeneral, Carrier, Daikin, Mitsubishi, Blue star, Voltas)
od74330/2019_2020 : Supply,Installation, Commissioning and Trial Run of 1.5 TR capacity high energy efficient ISEER 5star inverter type Split air conditioner operating on single phase AC supply, full copper coil, Non CFC Refrigerant, microprocessor control with cordless remote including 3m dual copper tube for suction and discharge line and 3m, 4 core electrical wire etc. complete. Make : ( O-General, Carrier, Daikin, Mitsubishi, Blue star, Voltas)
od74337/2019_2020 : Supply, Installation, Commissioning and Trial Run of 2 TR capacity high energy efficient ISEER 5star inverter type Split air conditioner operating on single phase AC supply, full copper coil, Non CFC Refrigerant, microprocessor control with cordless remote including 3m dual copper tube for suction and discharge line and 3m, 4 core electrical wire, etc. complete. Make : ( O-General, Carrier, Daikin, Mitsubishi, Blue star, Voltas)
od78170/2019_2020 : Supply and fixing of Suitable Heavy duty metallic Wall bracket/stand for the out door units of 1.5 TR & 2 TR split AC units as per site conditions including cost of material, labour etc complete and as per the direction of the Departmental officers at site with all taxes except GST.
Supply and installation of voltage stabilizer for split AC units- 5 KVA and 4KVA with voltage range of 175-275 V and output range of 210-240 V including all taxes except GST.
od74332/2019_2020 : Supply and fixing voltage stabilizer 4KVA with voltage range of 175-275 V and output range of210-240 V for 1.5 TR Split AC units
od78174/2019_2020 : Supply and fixing voltage stabilizer 5KVA with voltage range of 175-275 V and output range of210-240 V for 2 TR Split AC units
Supplying and fixing of extra Soft drawn 22 G Copper tube with insulation and Supplying and drawing of extra electrical wires of 2.5 Sq.mm Four core Copper conductor cable including cost of materials, labour etc. complete with all taxes except GST
od74331/2019_2020 : Supplying and fixing of extra Soft drawn 22 G Copper tube for suction and discharge, suitable for the split AC units with insulation including cost of materials and labour etc. complete
od78555/2019_2020 : Supplying and drawing of extra electrical wires of approved quality 2.5 Sq.mm, ISI Marked,FRLS PVC insulated Four core Copper conductor cable for connecting the indoor and outdoor units of split ACincluding all costs of material and labour etc complete
Supply and fixing Cable management system (CMS) with fittings-(100x50) for covering the electrical wires , copper tube etc., and CMS with Fittings of size 50x50 for covering the drain water line etc complete including all taxes except GST.
od74335/2019_2020 : Supply and fixing Cable management system (CMS) and fittings -size 100 x 50 mm of approved make for covering the electrical wires , copper tube as per site conditions including cost of materials, labour etc complete and as per the directions of the Departmental officers at site.
od78567/2019_2020 : Supply and fixing Cable management system (CMS) and fittings -size 50 x 50 mm of approved make for covering the Drain water line as per site conditions including cost of materials, labour etc complete and as per the Directions of Departmental officers at site..
Supply and fixing of 4 inch PVC with fittings as casing for copper tube, Electrical cable etc and Supply and fixing of 1 inch PVC with fittings for draining the sweating water etc complete including all taxes except GST.
od78578/2019_2020 : Supplying and Fixing of 4 inch PVC pipe with fittings of appropriate thickness for using as casing to Copper pipe, Electrical cables as per the site conditions including cost of materials labour etc complete and as per the directions of the Departmental Officers at site.
od78579/2019_2020 : Supply and fixing of 1 inch PVC pipe with fittings for draining the sweating water from the AC unit including costs of materials, labour etc complete as per the direction of the Departmental officers at Site.
Charges of clearing the site after finishing the entire work as per the direction of the departmental officers at site etc. complete with all taxes except GST
od78921/2019_2020 : Charges for clearing the site after finishing the entire work as per the direction of the departmental officers at site etc. complete including all taxes except GST
INTIMATE REFRIGERATION AND AIR CONDITIONS
Bidder Name
Seven Seas Infotech Systems
INTIMATE REFRIGERATION AND AIR CONDITIONS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_510915.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .