Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹39.8 L+₹1.0 L (2.71%)Rejected-Finance | L2 | Rejected-Finance Otherthan Lowest | |
| 3 | L3₹40.3 L+₹1.5 L (3.81%)Rejected-Finance | L3 | Rejected-Finance Otherthan Lowest | |
| 4 | L4₹41.5 L+₹2.7 L (6.87%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L4 | Rejected-Finance Otherthan Lowest | |
| 5 | L5₹42.3 L+₹3.5 L (9.03%)Rejected-Finance | L5 | Rejected-Finance Otherthan Lowest |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
7 Dec 2021, 6:00 pmClosed
GE 969 EWS
GE 969 EWS
PROVISION OF 40KVA DG SET FOR URI GRN 30 KVA DG SET FOR FSC NAUGAM WITH ALLIED INFRASTRUCTURE, PROVN OF 20 LED SECURITY LIGHTS FOR INF BN AT URI, SPECIAL REPAIR TO VOLTAGE STABILIZER UNDER STN HQ RAMPUR AND PROVN FOR REPLACEMENT OF FLURECSENT TUBE
2021_MES_487578_1
CANO 969/WS- /2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naugam, Uri
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 969 EWS
₹92,000
Yes
22 Jan 2022
11 Nov 2021
8 Dec 2021
11 Nov 2021
7 Dec 2021
24 Nov 2021
Amount
Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holesetc not exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out of soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line complete all as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm complete all as directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified
M&L for Sub class "B" bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified.
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth GI strip 32 x 6 mm (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work as Excavation, RF and removal etc
Supply and laying testing cable XLPE insulated screened PVC badded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with standard aluminium conductor of size 3.5 core 70 Sqmm
Supply and laying testing cable XLPE insulated screened PVC badded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with standard aluminium conductor of size 3.5 core 50 Sqmm
Supply and laying testing cable XLPE insulated screened PVC badded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with standard aluminium conductor of size 3.5 core 35 Sqmm
Supply and laying testing cable XLPE insulated screened PVC badded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with standard aluminium conductor of size 3.5 core 25 Sqmm
Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size 10 Sq mm 3 core.
Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size 120 Sq mm 3.5 core.
Supply and fix PVC insulated unsheathed copper cable of size 1.5 Sqmm 3 core FR PVC for service connections from junction box to light fitting.
Supply and fix loopin loopout fuse junction box of size 205 x255x112 mm made out of thermo plastic Polycarbonate with IP 66/67 weather proof for outdoor installation (with knockouts of cable entry) protection with terminals and locking screw fitted with 5 Amps fuse cutout-01 No with 6A MCB, suitable for cable size 10 sqmm and fixing on steel tubular pole at a height not less than 1.5m above ground level with the help of clamps two nos of F1 20 x 3 mm and suitable nuts and bolts compelete all as directed Make : Hensel or equivalent in sintex,Hansu
Supply and fixing 60 W LED New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver suitable for pole dia up to 40 mm. Make:- Havells/Philips/Surya/CG
Supply and laying GI pipe 25mm dia light grade for cable protection inside the coping with pole for junction box cable complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 30 KVA
Supply and fix sheet metal enclosures for DBs when MCBs to be used Verticle Ttriple Pole & Neutral (VTPN) double door 415 volts, 6 way with IP-43 IK-09 protection incl. 200 Amp bus bar and neutral link (ISI marked) complete all as specified and directed.
Supply and fix sheet metal enclosures for DBs when MCBs to used single pole & neutral (SPN) double door 240 volts, 12 way with IP-43 IK-09 protection incl. 200 Amp bus bar and neutral link (ISI marked) complete all as specified and directed.
S&F MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards confirming to IS/IEC 60898-1 (ISI merked) cat pt no- DSMSBSPF006-032 of standard or its equivalent make complete all as specified.
S&F MCBs Double Pole (DP) 6 to 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards confirming to IS/IEC 60898-1 (ISI merked) of Make : Indo Asian or its equivalent make in Havells/Standard/L&T complete all as specified.
M&L for Sub main wiring with 2 runs of 6 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC casing capping of required size with accessories along with 1 run of 6 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed. Note :- Two runs of 10 sqmm and one runs of 10 sqmm cable as earth along with PVC conduit will be measured as one length.
Supply and fix 4 Pole MCCB up to 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA adjustable type
Supply, installing, commissioning and testing complete of manufacturer or OEM (Original equipment Manufacturer) manufatured and tested silent static Diesel Engine driven generating set capable of delivering 40 KVA continuous rating, 10% overload for 1 hour in 12 hours of operation, 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and shall comprises of the following :-
Engine (prime mover) : Diesel engine 1500 RPM, of 56 BHP, fluid cooled, turbo changed, 12 volts electric one number maintenance free battery, complete with fly wheel and vibration damper, radiator and all standard fittings/fixtures as per standard manufacturing design practices and including suitable instrument panel with RPM meter, lubricant oil temperature & pressure gauge, water temperature gauge and freqency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT & LLOP alarm and shut down safeties.
Alternator : AC alternator, brushless, 415V, AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 40 KVA, PF 0.8, 1500 RPM, insulation class 'H' enclosure SPDP (IP 23), self excited & self regulated with AVR for +1% voltage regulation, coupled directly/suitably to and to match the above engine.
Base plate : Made out of structural steel as per manufacturer's recommended design/specifications.
Fuel tank : Fuel tank shall be of 24 hours capacity, made of 14 Gauge CRCA MS sheet, duly powder coated and provided with oil level indicator, draining plug, air vent float, gauge and fuel float switch.
Safeties : for high enclosures temperature and emergency shut-down from outside. 01 number, 180 AH, 12V lead acid batteries and adequate size copper conductor cable leads.
Engine control panel : Made of 14 gauge CRCA MS sheet, dust and vermin proof, (protection class IP 41 or superior), duly fitted with the equipment/ metres specified in particular specifications.
Automatic mains failure (AMF) control panel fabricated from minimum 14 gauge CRCA steel sheet (including CPRI type certified), dust & vermin proof, protection class IP -54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with single phase protection including adequate layers of powder coating floor mounting type with front opening, & panel shall comprises of all necessary accessories as per complete of Manufacturer or OEM.
Platform/Plinth/Base shall be provided as per manufacturers recommendations. Cost of the same shall deemed to be included in this item of work.
Tool kit : Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
Protection : Over load relay, Earth fault Relay, Under Volt release – 01 No each
Make of Engine : Koel Green Model, Make of Alternator : Kirloskar Green. Make of Canopy : Jakson & Co.
LT Cubical panel board made out of 3.15 mm thick CRCA sheet conforming to IS-8623 outdoor type totally enclosed dust and vermin proof with front and rear opening 415 volts 3 phase 4 wire having aluminium bus bar of capacity 200 Amp and half neutral RYB insulated with PVC sleeved insulation mounted on porcelain insulator complete with following items and internal wirings including 40x40x6 mm MS angle frame and painting with one coat of red oxide primer and two coats of powder coated paint internally and externally all as specified with following items complete all as specified and directed :-
Onload Change over switch 63 Amp, 415 Volts - 01
Incoming MCCB 3P, 100 Amps, 25 KA,415 Volts,50 Hz - 01 No
MCCB 3P, 63 Amps, 16 KA,415 Volts,50 Hz - 02 No
MCB DP 6-32 Amp, 50 Hz, 230 V with rupturing capacity 10KA. - 1 Nos
LED phase Indicator lamp with switches – 03 Nos
Note :- (i) Panel should be factory made
Extended terminals with tinned copper has to be provided for terminating the incoming & out going cable with suitable lugs for MCCB’s if required.(ii) Extended terminals with tinned copper has to be provided for terminating the incoming & out going cable with suitable lugs for MCCB’s if required.
LT Cubical panel board made out of 3.15 mm thick CRCA sheet conforming to IS-8623 outdoor type totally enclosed dust and vermin proof with front and rear opening 415 volts 3 phase 4 wire having aluminium bus bar of capacity 200 Amp and half neutral RYB insulated with PVC sleeved insulation mounted on porcelain insulator complete with following items and internal wirings including 40x40x6 mm MS angle frame and painting with one coat of red oxide primer and two coats of powder coated paint internally and externally all as specified with following items complete all as specified and directed :-
Onload Change over switch 63 Amp, 415 Volts - 01
Incoming MCCB 4P, 100 Amps, 25 KA,415 Volts,50 Hz - 01 No
MCCB 4P, 63 Amps, 16 KA,415 Volts,50 Hz - 02 No
MCB DP 6-32 Amp, 50 Hz, 230 V with rupturing capacity 10KA. - 1 Nos
LED phase Indicator lamp with switches – 03 Nos
Note :- (i) Panel should be factory made
Extended terminals with tinned copper has to be provided for terminating the incoming & out going cable with suitable lugs for MCCB’s if required.
Supply, installing, commissioning and testing complete of manufacturer or OEM (Original equipment Manufacturer) manufatured and tested silent static Diesel Engine driven generating set capable of delivering 30 KVA continuous rating, 10% overload for 1 hour in 12 hours of operation, 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and shall comprises of the following :-
Engine (prime mover) : Diesel engine 1500 RPM, of 42 BHP, fluid cooled, turbo changed, 12 volts electric one number maintenance free battery, complete with fly wheel and vibration damper, radiator and all standard fittings/fixtures as per standard manufacturing design practices and including suitable instrument panel with RPM meter, lubricant oil temperature & pressure gauge, water temperature gauge and freqency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT & LLOP alarm and shut down safeties.
Alternator : AC alternator, brushless, 415V, AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 30 KVA, PF 0.8, 1500 RPM, insulation class 'H' enclosure SPDP (IP 23), self excited & self regulated with AVR for +1% voltage regulation, coupled directly/suitably to and to match the above engine.
Base plate : Made out of structural steel as per manufacturer's recommended design/specifications.
Fuel tank : Fuel tank shall be of 24 hours capacity, made of 14 Gauge CRCA MS sheet, duly powder coated and provided with oil level indicator, draining plug, air vent float, gauge and fuel float switch.
Safeties : for high enclosures temperature and emergency shut-down from outside. 01 number, 180 AH, 12V lead acid batteries and adequate size copper conductor cable leads.
Engine control panel : Made of 14 gauge CRCA MS sheet, dust and vermin proof, (protection class IP 41 or superior), duly fitted with the equipment/ metres specified in particular specifications.
Automatic mains failure (AMF) control panel fabricated from minimum 14 gauge CRCA steel sheet (including CPRI type certified), dust & vermin proof, protection class IP -54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with single phase protection including adequate layers of powder coating floor mounting type with front opening, & panel shall comprises of all necessary accessories as per complete of Manufacturer or OEM.
Platform/Plinth/Base shall be provided as per manufacturers recommendations. Cost of the same shall deemed to be included in this item of work.
Tool kit : Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
Protection : Over load relay, Earth fault Relay, Under Volt release – 01 No each
Make of Engine : Koel Green Model : KG1-30WS, Make of Alternator : Kirloskar Green. Make of Canopy : Jakson & Co.
Supply & fix LED tube lightsalong with fixture 24 W with providing 2400 Lumens and helps save upto 50% power compared to convetional tubelight with shock proof luminaire with >0.9 power factor. Make : Crompton with model No LDRR24-CDL or equvalent to Bajaj or Philips
Supply & fix LED tube lightsalong with fixture, 20 W with providing 2400 Lumens and helps save upto 50% power compared to convetional tubelight with shock proof luminaire with >0.9 power factor. Make : Crompton with model No LDLSR20-CDL or equvalent to Bajaj or Philips
S & F fixed in repair Switch piano flush type single pole, one way 5/6 Amp.
S&F in repair Ceiling rose surface bakelite surface 65x50 mm 3 terminals fixed on wall/ceiling and including PVC block.
S&F in repair Lamp holder/angle batten, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings.
S&F LED Lamp 10 W 'T' type. Make : Crompton, cat No. LED 10W TWIST or equvqlent to Philips / Bajaj
S & F FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed copper conductor single core cable (90 Mtr). Make Havells
M&L Point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 25 mm medium grade ISI marked PVC casing caping with all accessories such as bends, elbow, reducers , junction boxes /MS boxes duly painted /PVC box factory made ractangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixed with screws, for housing switches, sockets, regulators etc, including 1.5 sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly for One light point controlled by one switch all as specified and as directed,
M & L for cement concrete for foundation fillings as floor of poles, conctere type D2 1:4:8 using 40 mm graded aggregate complete all as specified and directed.
M & L for cement concrete for copying of poles using B1 1:2:4, 20 mm graded aggregate, smooth finishing without using extra cement complete all as specified and directed. .
M & L for cement concrete for mass fillings of poles, conctere type C2 1:3:6 using 40 mm graded aggregate complete all as specified and directed.
Supply and fixing Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP- 31 (9.00 metres long) complete all as specified and as directed by Engr-in-Charge
S & F MCB SPN 32 Amps 10 KA and connecting to bus bars and cable end terminations with suitable lugs complete all as directed.
Supply and laying GI pipe 40mm dia light grade for cable protection on pole/road/culvert crossing and for on pedestal.
Supply and fixing GI pipe, bracket for street light fittings made out of 40 mm dia GI Pipe medium grade 1.20 m long bent to required angle/shape with and including necessary clamps, nuts, bolts & washers of suitable size and two coats of aluminium paint with a base coat of red oxide primer complete all as directed by Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 63 KVA
Supply and Install monoblock pump set 30HP, rated voltage 415, 50Hz, three phase AC power supply 48 mtr head, discharge 28 LPS with suction 100mm and deliver 80mm complete all as specified and directed by Engr-in-Charge. Model No KDS-3068 Kirloskar and same capacity in other as KBS/CG etc . Note : Rates are included as civil wk (PCC foundation of motor) and connected all electrical work to make functional.
supply and fix Centrifugal Monoblock pump set (Pipe size 50mm x 50mm) 1 HP, 8 to 14 mtr head and discharge 24000L/h - 9000L/h.
S&F Flat three Core copper cable PVC Insulated & PVC Sheathed Industrial Cable for monoblock pump set 30 HP.
Supply and Fix Star delta Starter fully automatic suitable for 415 V AC 50Hz 3 phase AC supply complete all as specified and directed by Engr-in-Charge. Make: Havells/CG/L&T
M/S KULWANT SINGH RAINA AND CO
M/S KULBIR SINGH SODHI AND CO
FG CONSTRUCTION
M/s FAYAZ AHAMD WANI AND SONS
M/S PARADISE TRADERS AND CO
M/S IQ ENTERPRISES
M/S Sky Engineers
M/S Khan Hussain & Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .