Loading…
Loading…
57 results • Latest
Janpad Rampur mai Dr APJ Abdul kalam Inspection me saundaryikaran hetu vahya Prakash viyvastha ke liye Octagonal pole, bolard light lagane evam main bhawan me fire extinguisher geejar ceiling fan fresh air fan wall bracket evam LED fittings etc karya
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS / International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating
As per tender documents
CAPABILITY STATEMENT
11 or 33 kV Outdoor Live Tank Current Transformer (BHEL) (Q3)
11 or 33 kV Outdoor Live Tank Current Transformer (BHEL) (Q3)
Manpower Outsourcing Services - Minimum wage - Unskilled; 5th Pass; Admin, Manpower Outsourcing Services - Minimum wage - Skilled; 12th Pass and O Level Diploma; Admin
Manpower Outsourcing Services - Minimum wage - Unskilled; 5th Pass; Admin
Hydrated Lime (V3) Conforming To Is 1540 (Part 2) (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Hydrated Lime (V3) Conforming To Is 1540 (Part 2) (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Solvent cement for use with unplasticized polyvinylchloride plastic pipe and fittings conforming to IS 14182 (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Solvent cement for use with unplasticized polyvinylchloride plastic pipe and fittings conforming to IS 14182 (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No