Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹24.3 L+₹1.5 L (6.61%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹26.0 L+₹3.2 L (14.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹26.4 L+₹3.7 L (16.1%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L4 | Rejected-Finance L4 | |
| 5 | L5₹26.7 L+₹3.9 L (17.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
30 Nov 2024, 6:00 pmClosed
Maj Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR MAINTENANCE OF INTERNAL WIRING COOLING APPLIANCES AND OTHER CONNECTED WORKS AT AF STN SAMANA UNDER GE (AF) JAMNAGAR NO 1
2024_MES_683156_1
8318/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Samana under Jamnagar
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹50,000
Yes
6 Jan 2025
9 Nov 2024
2 Dec 2024
9 Nov 2024
30 Nov 2024
23 Nov 2024
Amount
Material & Labour in repair for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC capping & casing not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC surface type terminal box of suitable size with PVC cover complete.
All as per item No 1 above but point wiring for One light point controlled by two Nos 2-way switch
All as per item No 1 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch.
All as per item No 1 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch.
All as per item No 1 above but One bell /Buzzer point controlled by one push button on the same board with other switch
All as per item No 1 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC casing and capping not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with casing and capping will be measured as one RM for payment.
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
Material & Labour in repair for sub main wiring with 4 run single core multistranded copper conductor cable, of size 10.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 40 mm wide with all necessary fitting and including two run single core multistranded copper conductor cable, of size 10.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete.
M&L in repair Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete.
M&L in repair Switch Piano type, white polycarbonate body, single pole, two way 6 amp, 230 V, including connecting complete.
M & L in repair for Bell push, white polycarbonate body, 6 Amp, 230 V, including connecting complete.
M & L in repair for Switch socket combination white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete.
M & L in repair for Switch socket combination white polycarbonate body, 6A / 16A- 230 V, Multipurpose, including connecting complete.
M & L in repair socket outlet 2 in 1 ,6/16 amps 5 in 1 flush type white polycarbonate body 230 V, Multipurpose, including connecting complete.
M & L in repair socket outlet 3 pin 6 amps amps flush type white polycarbonate body 230 V, Multipurpose, including connecting complete.
M&L in repair for casing capping of size 25-32 mm with its necessary accessories screw and bolt etc complete.
M&L in repair for pvc conduit of size 20-25 mm with its necessary accessories screw and bolt etc complete.
S&F in reapir capacitor 2.5 Mfd suitable for ceiling fan complete.
S&F in repair modular type switch, 230 volts, single pole one-way 6 Amps in 1 module & connecting complete.
Supply and fix in repair modular type bell push, 230 volts, single pole one-way 6 Amps in 1 module including connection complete.
Supply and fix in repair modular type white socket 3 pin cum 2 pin, 6 Amps 230 volts in 2 modules
Supply and fix modular type white switch, 16 Amps 230 volts in 1 modules.
Supply and fix modular type white fan regulator stepped type of 120 watt in 2 modules.
Supply and fix in repair surface plastic box of 1 module for mounting switch/socket inluding taking out old box and connecting all wires connection as in working condition as directed by Engr-in-chrage.
Supply and fix in repair surface plastic box of 2 module for mounting switch/socket inluding taking out old box and connecting all wires connection as in working condition as directed by Engr-in-chrage.
Supply and fix in repair surface plastic box of 4 module for mounting switch/socket inluding taking out old box and connecting all wires connection as in working condition as directed by Engr-in-chrage.
Supply and fix in repair surface plastic box of 8 module for mounting switch/socket inluding taking out old box and connecting all wires connection as in working condition as directed by Engr-in-chrage.
Supply and fix in repair 3 module top plate with support plate of modular fitting including taking down old one.
Supply and fix in repair 8 module top plate with support plate of modular fitting including taking down old one.
M&L in repair for Ceiling rose, 3 terminal polycarbonate body 6 Amps, 250 volts AC, including connecting complete.
Supply and fix in repair stepped type electronic fan regulator flush type, 230 V, including connecting complete.
M & L for Bell ding dong AC 230 Volts, single pole, including connecting complete.
S&F in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type,240 V fixed flush to wall complete all as specified and directed.
S&F in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type,240 V fixed flush to wall complete all as specified and directed.
S&F in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type, fixed flush to wall complete all as specified and directed.
S&F in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way, vertical type with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, double door type 415 volts, fixed flush to wall complete all as specified and directed.
Supply and fix in repair MCBs single pole 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in repair MCBs single pole & neutral, 40-63 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in repair MCBs single pole & neutral, 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCBs triple pole & neutral, 40-63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in repair MCBs triple pole & neutral 6-32 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in repair 2x36 watt,240 V,50 Hz electronic choke suitable for false ceiling light fitting complete.
Supply and fix in repair 40 watt,240 V,50 Hz electronic driver suitable for false ceiling light fitting complete.
Supply and fix in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 amps, 240 V.
S&F in reapir 18 watt Ballast , 220 V , 50 HZ suitable for 18 watt CFl light fitting.
S&F in repair 18 watts CFL, 2 or 4 pin type fixed to CFL light fittings .
S&F in repair 36 watts CFL, 2 or 4 pin type fixed to CFL light fittings.
S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 8 to 10 watt, channel housing & diffuser of length 600 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 5 watt, channel housing & diffuser of length 300 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
Supply and fixing in repairs LED bulk head light fitting of 10 Watt capacity, Cool white with all connected accessories fixed in position complete..
S&F in repair Recessed mounted LED smart down light of 10-12 watt, 4000 K including all fitting, fixture complete.
S&F in repair Recessed mounted LED smart down light of 5-6 watt, 4000 K including all fitting, fixture complete.
S&F in repair Recessed mounted LED round panel light of 15-16 watt, 6500 K of including all fitting, fixture complete.
Supply and fix in repair driver for Energy efficient recessed mounted LED luminaries 36 watt suitable for 600 x 600 mm grid ceiling along with flat diffuser along with constant current electronic driver including taking down and refixing all as specified and directed by Engg-in-charge .
Supply and fix in repair Energy efficient recessed mounted LED luminaries 36 watt suitable for 600 x 600 mm grid ceiling along with flat diffuser along with constant current electronic driver all as specified and directed by Engg-in-charge .
Taking down carefully ceiling fan / wall mounted fan/exhaust fan by disconnecting electric connection for repairing such as rewinding, replacement of defective spare part, over hauling etc as required and re-fixing in the same position after carry out the repairs works, and connecting complete all as directed by Engr-in-Charge. Note:- (i) Repairing such as rewinding, replacement of defective spare part, connecting wire etc will be measured & paid separately as supply & fix in repair . (ii) Overhauling and painting will be measured and paid separately. (iii) Replacement of nut, bolt ,washer, split pin and rubber seal for the down rod of ceiling fan if found defective will be measured and paid separately as supply only.
M & L for rewinding of ceiling fan 1200 mm sweep of any make, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enameled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge.Replacement of bearing and capacitor will be measured and paid seprately.
M & L for rewinding of wall mounted fan 400-600 mm sweep of any make by dismantling the fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enameled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge.Replacement of bearing and capacitor, etc. will be measured and paid seprately.
All as item No 61 above but exhaust fan 300 mm sweep.Replacement of bearing and capacitor, arms set, etc. will be measured and paid seprately.
All as item No 61 above but exhaust fan 450 mm sweep.Replacement of bearing and capacitor ,arms set, etc. will be measured and paid seprately.
Supply& fix in repair only MS clamp with MS nuts, bolts, rubber bush, quarter pin complete for the down rod of ceiling fan.
Supply and fix in repair ball bearing suitable for ceiling fan 1200 mm sweep of any type and make all as specified and directed.
Supply and fix in repair Capacitor of 4/3.15 mfd capacity for exhaust fan of any sweep including removing old one
supply and fix in replacement for plastic body exhaust fan of capacity 250 mm exhaust fan
supply and fix in repair ball bearing for exhaust fan of capacity 300 mm exhaust fan
supply and fix in repair ball bearing for exhaust fan of capacity 450mm exhaust fan
supply and fix in repair fan downrod of 18 inch.
Comprehensive / Preventive maintenance / servicing of split AC up to 2.0 ton capacity of any make. Maintenance carried out by cleaning of cooling and condenser coil of indoor and outdoor units with descaling solution, checking of refrigerant pressure and charging of refrigerant gas including testing / checking the serviceability of spares such as starting capacitor, running capacitor, fan motor, blower motor relays, thermostat, & wiring etc and servicing complete of indoor and outdoor units complete. Note:- (i) Spares such as starting capacitor, running capacitor, fan motor, blower motor relays, thermostat, & wiring etc if found defective will be measured & paid separately as supply & fix in repairs.
(ii) Charging of gas if required will be measured and paid separately as supply & topping of gas. (iii) Replacement of compressor wherever required will be measured and paid separately.
Material & labour for recharging of R-32/22/407/410/134 gas to split type air conditioner of capacity 1.5 / 2.0 TR after flushing the complete system, vacuum testing and the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete.
Material & labour for recharging of R-32/22/407/410 gas to refrigerator of capacity 300 / 310 ltrs after flushing the complete system, vacuum testing and the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete.
Material & labour for recharging of R-32/22/407/410 gas to water cooler of storage capacity 80/120 ltrs & cooling capacity 40 ltrs after flushing the complete system, vacuum testing up to 24 hours and the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete.
Dismantling blower of split AC 1.5 / 2 TR and supply and fixing new fan blower of indoor unit in reapir along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.
Dismantling blower fan motor of split AC 1.5 / 2 TR and supply and fixing new fan motor of indoor unit in repair along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.
Dismantling blower fan motor of split AC 1.5 / 2 TR and supply and fixing new fan motor of outdoor unit in repair along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.
Dismantling blower fan motor of 80/40 and 120/150 ltrs water cooler and supply and fixing new fan motor in repair along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.
S&F in repair Over load Protector suitable for window type AC of capacity 1.5 Ton all as specified and directed by Engineer-in-charge.
S&F in repair starting capacitor 80 to 100 MFD suitable for window type AC / Split AC of capacity 1.5-2 TR, water coolar 120/80 Ltrs, all as specified and directed by Engineer-in-charge. Make Keil, Keltron,Epcon or equivalent as approved by the GE.
S&F in repair running capacitor 36 MFD suitable for window type / Split AC 1.5 / 2.0 Ton all as specified and directed by Engineer-in-charge.
S&F in repair starting relay suitable for water cooler of any capacity all as specified and directed by Engineer-in-charge.
S&F in repair thermostat switch suitable for refrigerator of capacity 165 / 300 Ltrs all as specified and directed by Engineer-in-charge.
S&F in repair contactor relay suitable for split type air conditioner of capacity 1.5 /2 TR capacity all as specified and directed by Engineer-in-charge.
M&L for replacement non invertor PCB suitable indoor/ outdoor for split type AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts transformer,diode,triode,condensor etc. all as specified and directed by Engineer-in-charge.
S&F in repairs replacement of PCB for indoor unit suitable for inverter type split type AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etc. all as specified and directed by Engineer-in-charge.
S&F in repairs replacement of PCB for outdoor unit suitable for inverter type split type AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etc. all as specified and directed by Engineer-in-charge.
S&F in repair cooling effect transmitting motor suitable for refrigerator 310 Ltrs capacity all as specified and directed by Engineer-in-charge.
M&L in Repairs to internal remote assembly corded / cordless of split type AC 1.5 / 2.0 ton capacity .
Supply and fix in repair PVC flexible pipe of 15 mm dia suitable for Split AC out let of water drain pipe complete all as specified and directed.
Supply and fix outdoor unit condensing coil (Aluminum material) whole assembly suitable for 1.5/2 TR split AC along with standard accessories, fitting, fixture including fixed in position as per standard practice and dismantling / taking down complete.
Supply and fix outdoor unit condensing coil (copper material) whole assembly suitable for 1.5/2 TR split AC along with standard accessories, fitting, fixture including fixed in position as per standard practice and dismantling / taking down complete.
Supply and fix in repairs brass service valve of size 3/8" suitable for split ACs of any capacity.
Supply and fix in repairs brass service valve of size 5/8" suitable for split ACs of any capacity.
Supply and fix in repair insulation on copper pipe of split AC of size 1/4 inch internal diameter and thickness 6mm .
Supply and fix in repair insulation on copper pipe of split AC of size 1/2 inch internal diameter and thickness 6mm .
Supply and fix in repair cupromet copper tube ASTM B68 of size 1/4 inch x 0.48 mm .
Supply and fix in repair cupromet copper tube ASTM B68 of size 1/2 inch x 0.48 mm .
Supply and fix in repair PVC insulated and PVC sheathed 3 core with multi stranded flexible copper cable of size 2.5 sqmm including connecting complete for desert cooler.
Supply and fix in repair PVC float valve with complete set of rod and ball of 15 mm size for water cooler of any capacity.
Supply and fix in repairs stainless steel drain water tray of water coolers of any capacity of existing size by suitable size of screws nut and bolts.
Supply and fix in repair thermostate with relay for electric geyser or solar water heater of capacity 2KW, 220/230 volts.
Supply and fix in repair Heating element of electric geyser of capacity 2KW, 220/230 volts all as directed.
Supply and fix in repair Hot water connection (2 nos) brass chromium plated, with brass chromium plated hexagonal adaptor, 450 mm long complete with rubber washer, ISI marked complete.
Supply and fix in repair Plug top 3 pin 15 Amps, polycarbonate body, ISI marked & connecting complete.
M&L for replacement of 5 Kva Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with out put voltage stabilized at 230V with accuracy of ±2.5%
S&F in repair AC 3 pin metal clad top fuse for AC power supply box.
M&L for taking out unserviceable compressor sealed unit of 40/80 water cooler (Make - Carrier / LG / Blue Star / Voltas / Shriram), single phase 230 Volts, and replacing the same with new compressor sealed unit fixing & connecting the same including vacumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete. Note: Unserviceable old retrieved compressor shall be replace with the same through authorized dealer / company manufacturer.
M&L for taking out unserviceable compressor sealed unit of 1.5 ton capacity from the split type AC (Make - Carrier / LG / Blue Star / Voltas / Shriram), single phase 230 Volts, and replacing the same with new compressor sealed unit fixing & connecting the same including vacumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete. Note: Unserviceable old retrieved compressor shall be replaced with the same through authorized dealer / company manufacture.
M&L for taking out unserviceable compressor sealed unit of 2 ton capacity from the split type AC (make - Carrier / LG / Blue Star / Voltas / Shriram), single phase 230 Volts, and replacing the same with new compressor sealed unit fixing & connecting the same including vacumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete. Note: Unserviceable old retrieved compressor shall be replace with the same through authorized dealer / company manufacture.
Supply and fix in replacement heavy duty Air conditioner outdoor Ac stand for 0.8 to 2 ton (mounting bracket) 24 inch including taking out old bracket with AC and and refixing the AC with new bracket.
Supply and fix in repair honeycomb pad numbers for air suction side for Symphony Hicool i 31 Litre Air evaporative cooler of cooling capacity of 50 Sqft.
Supply and fix in repair desert cooler submerssible pump of capacity 8 watt,220-240 V,50 Hz and maximium lift of 1 meter. Make:- crompton greaves/khaitan/usha/Symphony
Supply and fix in repair centifuge type fan blade along with its two bearing suitable for Symphony Hicool i 31 Litre Air evaporative cooler of cooling capacity 50 sqft .
Supply and fix in repair fan motor of capcity 185 watt ,230 V, 50 Hz for Symphony Hicool i 31 Litre Air evaporative cooler . Make:- crompton greaves/khaitan/usha/Symphony
Supply and fix in repair PCB board of Symphony Hicool i 31 Litre Air evaporative cooler .
M&L for taking out and rewinding of Exhaust fan motor of capacity 500 watt ,230 V,50 HZ for industrial desert cooler of sweep 1400 sqft with copper wire, after rewinding fix it in its position complete in running condition with connection complete.
Supply and fix in repair 5 amps 240 V, three pin plug top.
M&L for servicing/repairing of 8 zone adressable / conventional fire alarm panel including rewiring/soldering and adressing of all detectors correctly as required with integration with FACP programming all as directed.
Supply and fix in repair Fire resistant copper armoured cable 1.5 sqmm for adressable / conventional fire alarm system Make:-RR kabel or equivalent as approved by the GE.
Supply and fix in repair adressable Manual Call pont for fire alarm system Make:-ravel or equivalent as approved by the GE.
Supply and fix in repair adressable smoke detector for fire alarm system Make:-ravel or equivalent as approved by the GE.
Supply and fix in repair adressable heat and smoke detecror for fire alarm system Make:-ravel or equivalent as approved by the GE.
Supply and fix in repair loop card for adressable fire alarm system Make:-ravel or equivalent as approved by the GE.
S&F in repair dry battery 12V 7.2 AH suitable for fire alarm panel all as specified and directed. Make:- Exide/Amron / equivalent as approved by GE.
M&L for Servicing of R.O. Plant of 50 Ltrs/Hr capacity, at AF station Samana, by circulating citric acid with water to cleaning the modules and descaling of system to improve flow and to reduce TDS and including replacement of flexible tubes etc and replacement of spare parts all as directed. Note:- (i) Servicing is to be carried out when Filter is chocked and TDS is not as per specified value. (ii) Spare parts required will be measured & paid separately under respective items of this Schedule.
M&L for Servicing of R.O. Plant at OMQ & SMQ area at AF station Samana of capacity 1000 Ltrs / Hrs by circulating citric acid with water to cleaning modules and descaling of system to improve flow and to reduce TDS and all as directed at site including replacement of spare parts all as directed. Note:- (i) Servicing is to be carried out when Filter is chocked and TDS is not as per specified value. (ii) Spare parts required will be measured & paid separately under respective item of this Schedule.
Supply and feed in repair only sand suitable for commercial RO plant 1000 Ltrs/hr.
Supply and feed in repair only Carbon media charcoal suitable for commercial RO plant.
Supply and fix in repair multiport valve of FRP tank for RO plant of capacity 1000 Ltrs/hrs.
S&F in repair water level sensor switch for 50 Ltrs capacity RO plant along with its adapter complete.
Supply and fix in repair FRP tank vessel for RO plant of capcity 1000 Ltrs/hrs of operating pressure maximum 100 PSI, Max Vacuum 17 KPa and temperatute 1-50 centigrade. Make:- Proteck water technologies/ Hydro tech engineers.
Supply and fix in repair FRP housing vessel for membrane 8040 for RO plant of capcity 1000Ltrs/hr.
Supply and fix in repair membrane suitable for R.O. Plant of capacity 1000 Ltrs / Hrs Capacity of size 80 cm dia and 40 inch length. Make : Dow 8040 or Equivalent make approved by the GE
Supply and fix in repair membrane suitable for R.O. Plant of capacity 50 Ltrs / Hrs Capacity of size .
Supply and fix in repair Candle PP spun filter 5 micron filter 10'' Long 'Dia suitable for R.O. Plant of capacity 50 Ltrs / Hrs
Supply and fix in repair Candle PP spun filter 5 micron filter 20'' Long 4''Dia suitable for R.O. Plant of capacity 1000 Ltrs / Hrs
Supply and fix in repair Candle thread solid filter 20'' Long 4''Dia suitable for R.O. Plant of capacity 1000 Ltrs / Hrs
Supply and fix in repair 50 LPH diaphragm RO pump with connections and pipe as directed by engineer in charge
M & L for repair to electronic metering pump of capacity dosing rate 4 Kg per square cm of 400 stokes per minute set for chlorine dozing and incl suitable guage rewiring copper wire with properly insulating material and replacement of display,internal circuit,solenoide valve, bearing,impellar,bush,shaft,suction valve,discharge valve complete.
S&F in repair presure switch of range 0.2 to 7.5 bar pressure and differential pressure 0.7 to 4 bar range. Make:- Danfoss/honeywell/ equivalent as approved by GE.
Supply only RO sediment filter housing vessel (set of three) (for spun and solid thread filter) with its top mounting assembly for 1000 ltrs capacity RO plant complete
Supply and fix in repair RO starter panel with star delta connection for 1000 ltrs capacity RO plant complete
Supply and fix in repair only flow meter of capacity 250-2500 ltrs suitable for RO operating panel. Make:- Arose / servotec Engineers / equivalent as approved by the GE.
M&L sodium hypochlorite solution liquid (NAOCL) 6% capacity all as specified and directed by Engg in-charge
Sagathiya Builders (BID ID -3177392)
Jagdamba Engineering (BID ID -3177452)
M/s SK Traders (BID ID -3177523)
Pooja Enterprise (BID ID -3177778)
Krishna Bhoomi Enterprise (BID ID -3177540)
KEVAL ENTERPRISE (BID ID -3177461)
Indice Technologies (BID ID -3177330)
DWARKADHISH ENTERPRISE (BID ID -3177826)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .