| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 CrAccepted-AOC DOOR NO 50 53 2 5 FLAT NO 504 SRI SAI VENKATESHWARA RESIDENCY NE LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | ₹1.6 Cr | 1 | Accepted-AOC Being Lowest Bidder |
| 2 | 2₹1.7 Cr+₹4.3 L (2.63%)Rejected-Finance | ₹1.7 Cr+₹4.3 L (2.63%) | 2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | 3₹1.7 Cr+₹10.6 L (6.47%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | ₹1.7 Cr+₹10.6 L (6.47%) | 3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | 4₹1.8 Cr+₹13.7 L (8.34%)Rejected-Finance | ₹1.8 Cr+₹13.7 L (8.34%) | 4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | 5₹2.2 Cr+₹57.7 L (35.1%)Rejected-Finance MIG 76 DR NO 39 33 146 2 3 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530018 | ₹2.2 Cr+₹57.7 L (35.1%) | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.7 Cr
EMD Value
₹2.4 L
Closing Date
16 Jul 2020, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Provision of Sewage Treatment Plant for Accommodation areas at INS Viswakarma, Visakhapatnam
2020_MES_344631_2
81991 / E8
Open Tender
Solid Waste Management
Item Rate
2095 days
Visakhapatnam
Class B
Category c vii
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Depot
₹2.4 L
Yes
27 Aug 2020
2 Jul 2020
23 Jul 2020
2 Jul 2020
16 Jul 2020
2 Jul 2020
Amount
PHASE – I [Schedule "A" Part – I]: [Sewage Treatment Plant, RCC Sump cum Pump House including B/R & E/M Works]:
Design and Construction [Hydraulically, Structurally and Aesthetically] of RCC Sump Well cum Pump House [RCC framed structure] suitable for average flow of 51 to 100 Cu.m per day [Approximate size of Sump Well shall be 6.50m in depth and 2.00m inner dia & Approximate size of the Pump House shall be 3.00 X 4.00 X 3.00 metres] including RCC foundation, container walls based on Hydraulic Data, Ground Data, Special Conditions, Particular Specifications, Architectural Drawings and other provisions given in tender documents including testing as specified including all internal and external finishes as per Zonal Specifications, all piping connections, Valves, Internal Electrification, MS Ladder, Ventilation Shaft, Brick work chambers with outer wall of tank of size 5m complete including testing for water tightness and hydraulic functioning, Vetting & Certification by IIT / NIT / Government Engineering College within one month of acceptance of tender, Preparatory works, Super Structure, Drainage Arrangement, Protective Works, Earthwork as required and all other items of work required and necessary for the complete construction of the facility complete all as specified and as directed. Note: Structural drawings of all RCC Structures required to be constructed shall be submitted duly vetted by IIT / NIT / Government Engineering College within one month of acceptance of tender. Reinforcement shall be High Strength Corrosion Resistant Deformed TMT Steel bars of Grade Fe-500D. All RCC works shall be in M-30 [Design Mix] Concrete all as specified in Particular Specifications. Cement of OPC Grade - 43 shall be used for all RCC [Design mix] work.
Design, supply, install, commissioning and testing of Sewage Treatment Plant [STP] based on principle of Soil Bio Technology [SBT] CAMUS-SBT [CSBT] having capacity 100 KL per day including all civil works for the STP and as per the Technology Provider(s) / OEM recommendations and all as specified at INS Viswakarma including MOU with technology provider M/s. Vision Earthcare Pvt. Ltd., CSRE Building, SINE, IIT Bombay, Powai, Mumbai – 400 076 [Phone: 022–25721317] to achieve the following parameters and other parameters as mentioned in the tender documents: Note: Bidders are free to enter MOU with any vender/OEM whose name is not mentioned in tender documents but approved by E-in-C's branch for providing STP based on Soil Bio Technology [SBT]
Inlet Parameters of Sewage: BOD : 250 – 350 mg / Litre COD : 400 – 500 mg / Litre TSS : 150 mg / Litre Oil & Grease : 20 mg / Litre PH : 6.0 to 9.0 Coliform : 1 X 107 MPN / 100 ml Peak Factor : 2.5
Treated Sewage Quality [Outlet Parameters]: BOD < 10 mg / Litre COD < 50 mg / Litre TSS < 10 mg / Litre Oil & Grease < 10 mg / Litre PH – 6.5 to 8.5 Coliform < 100 MPN / 100 ml Residual Chlorine > 1 mg / Litre
COMPONENTS OF STP PLANT: STP based on SBT technology shall have the following components/structures etc. The equipment for the STP shall be as per OEM Recommendations: Part – A: [i] Bar Screen Chamber / Coarse Screen Chamber [ii] Equalisation Tank / Raw Sewage Tank [iii] Collection Tank 1 [iv] Admin Building cum Control cum Operator Room [v] Bio Reactor 1 / Bio Reactor 2 [vi] Secondary Clarifier [vii] Treated Water Tank [viii] Treated Effluent Tank with necessary accessories [ix] Bio Reactor Media Bio Reactor Catalyst [x] Connection between last Manhole / Sump to Bar Screen Chamber [xi] Raw Sewage Pumps [one working + one standby] [xii] Dosing Pump [xiii] Hypo Dosing Pump [xiv] Sludge Transfer Pumps [xv] Treated Sewage Transfer [xvi] Disinfection [xvii] One 2000 Litres PVC water tank on 3.00 metre brick staging with connection from clear water sump to supply clear / treated water to garden
PART – B: [i] Media [Brick Bats / Laterite Blocks / Hard Moorum / Equivalent] 80 - 150 mm, Powder Free [ii] Under Drain - Rubble / equivalent 60 -100 mm [iii] Additive - Grit 8 - 12 mm [iv] Jute Layer 50 - 100 GSM [v] Plantation along with Garden Soil [vi] Culture & Catalyst [proprietary Vision Earthcare Bombay] [vii] Technology Supervision [viii] Raw Sewage Pumps [one working + one standby] [ix] Clear Water Pumps [Two working + Two standby] [x] Disinfection by Dosing Pump
PART – C: [i] Electrical Work - 1 No Electrical Panel for operation of electrical units of Sewage Treatment Plant with 1 lot of Electrical cabling from STP Panel and various drives with suitable cables and Earthing etc. as required and as directed. [ii] Necessary foundation, valves, instruments, piping for inter connection garnets etc. as required technically as per OEM recommendations. [iii] Any other structure / Component / Pump / T & P etc. for smooth functioning of STP to achieve the outlet parameters.
Notes: [i] Since the design of STP shall be as per OEM, please note that unit rate quoted for Sewage Treatment Plant shall be deemed to be inclusive of full and final completion of work as per BoQ, Particular Specifications and specifications as per OEM recommendations read in conjunction with each other. Any item not covered in the scope but essential for smooth functioning of STP shall be provided as per OEM/Technology providers. The quoted rate is inclusive for the same. No additional claim whatsoever in this regard shall be entertained. [ii] Structural drawings of all RCC structures required to be constructed in the subject work shall be submitted duly vetted by IIT / NIT / Government Engineering College within one month of acceptance of tender. Reinforcement shall be High Strength Corrosion Resistant Deformed TMT Steel bars of Grade Fe-500D. All RCC works shall be in M-30 [Design Mix] Concrete. [iii] The complete scheme of STP shall be vetted by OEM / technology provider for its 100 KLD sewage hold by capacity and use of SBT technology.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft / Loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth exceeding 1.5m but not exceeding 3.0m and getting out in Soft / Loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
M & L for Moorum / Red Bajri filling under Floors or in Pavings laid in layers not exceeding 15 cm thick, spread levelled and rammed / rolled with power road roller of 8 to 12 ton capacity including watering to and consolidated to required level, gradient and camber required complete all as specified and as directed. Note: Measurements shall be taken after consolidation of earth and 10% deduction shall be made for payments.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M & L for 100mm thick Sand filling as in sand bed to Inter Locking Paving Blocks including filling interstices complete all as specified and as directed.
M & L for Inter Locking Paving Blocks of 100mm thick, made with M50 Grade cement concrete using 20 mm graded stone aggregate, Hydraulically pressed of approved colour and pattern, shape and size conforming to IS - 15658 set in floors complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6, Type C-2, using 40mm graded aggregate as in Sub base for flooring complete all as specified and as directed.
M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled with power road roller of 8 to 12 ton capacity and consolidated to required gradient and camber complete all as specified.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for 150 mm dia RCC Pipes, Class NP 3, laid and jointed with collars laid in trenches and jointed complete all as specified and as directed.
M & L for 200 mm dia RCC Pipes, Class NP 3, laid and jointed with collars laid in trenches and jointed complete all as specified and as directed.
M & L for concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
M & L for concrete bed to drain pipes of size 200 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
Supplying and laying 200 mm bore Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" with Spigot and Socket ends conforming to IS – 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating complete all as specified and as directed.
Supplying, fixing and testing of Ductile Iron, Heavy Duty, Specials of any size, radius and length confirming to IS – 9523 such as bends [any type, radius and angle], tapers any type [straight, bend, increasing, decreasing or double socket etc], sockets, tail pieces, connecting pieces, tee pieces, single branch, "Y" junction, double branch, cross, [all sockets or socket and spigot], collars, caps and plugs, adopters etc suitable for Ductile Iron Spigot and Socket pressure pipes complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:6, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only integral water proofing compound [ISI marked] of approved make.
M & L for Plain / Reinforced cement concrete Type B1 [Nominal Mix] 1:3:6 using 20mm graded stone aggregate cast in situ in lintels up to 1.5m span, Cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed.
M & L for providing Precast RCC 1:2:4, Type B-1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], Chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and as directed.
Use and removal of steel formwork to Edges of Concrete Flats, Treads, Breaks in Floors, Window Cills, Concrete Railings, Openings in Concrete Walls, Floor and Roofs not exceeding 20cm wide and sides of RCC / PCC Bands in Walls, horizontal or sloping and similar work exceeding 20cm wide for fair finished surface of concrete complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F PP-R Gate Valves [Brass Insert] suitable for 50mm outer dia complete all as specified and as directed.
S & F PP-R Gate Valves [Brass Insert] suitable for 40mm outer dia complete all as specified and as directed.
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 40 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed.
S & F PP-R Gate Valves [Brass Insert] suitable for 20mm outer dia complete all as specified and as directed.
S & F 50mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing complete all as specified and as directed.
S & F 40mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing complete all as specified and as directed.
S & F 25mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing complete all as specified and as directed.
S & F GI water tubing of 80 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
M & L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinery including GI pipe, 150mm bore, Light grade for drawing cable complete all specified and as directed.
Supply, Install, connect, commissioning and testing of Electrically Driven, Non-Clog, Vertical Submersible Pump Set, Multistage, with 1487 RPM [Synchronous] Motor, Chrome Steel Impeller, suitable for operation at a Head of 17 metres with a discharge of 15 Cu.m per Hour [at maximum efficiency], Delivery Casing, Impeller and Motor body made of Cast iron, 80mm x 80 mm size suction & delivery bore inclusive of guide rail and lifting chain, cables, earthing, testing complete, IP 68 Protection with minimum operating temperature 40°C, suitable for operation 440 Volts, 3 Phase, 50 Hz, AC Supply, provision of suitable Starter Panel, Float Switch and connecting up with submersible cable, copper conductor, 3 Core, 4 Sq.mm, multistranded, PVC, Flat type, water proof including cable glands, lugs, jointing materials etc. from Starter Panel to Pump & Float Switch complete all as specified and as directed. Note: The suction / delivery pipe and starter required for connections will be measured and paid separately under relevant schedule items.
S & F GI water tubing of 40 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed.
M & L for Cutting existing 80mm bore GI Water Mains for drawing 40mm bore GI branch by inserting 80 X 80 X 40 mm GI reducer Tee, necessary GI Specials including jointing, excavation and earth work, dewatering etc. complete all specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified and as directed.
All as per Serial Item No. 41 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 41 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Switch Piano, Flush Button, Single Pole, One Way, 5 Amps, 230 Volts complete all as specified and as directed.
S & F Switch Socket Outlet, 3 & 2 Pin, Multipurpose, 5 Amps, 230 Volts, Flush Type complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Switch Socket Outlet, Multipurpose, 3 pin, 15 Amps and 3 pin, 5 Amps, Flush Type, 230 Volts controlled by One Switch complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Flush Type, AC, 230 Volts, Single Pole complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
S & F MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB, TPN, 40 to 63 Amps, 10 KA, 415 Volts, 50 Hz, complete all as specified and as directed.
S & F MCB, SPN, 6 to 32 Amps, 10 KA, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1800 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 900 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 373, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, of approved colour including Down Rod, Canopies, 3 Nos. Blades, Shackles, Safety Rope, Hanging Clamps, Bushes and having P.F >0.94, Service Value >6.5, Air Delivery >215 CMM, Power Consumption less than 35 Watt, THD less than 5% with speed control by Electronic Regulator including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F Exhaust Fan, 450mm Sweep, 1400 RPM, Metal Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F Energy efficient & Long life Building Security Light / Roadway Luminaire, of not less than 4500 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 70 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 10 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 6 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
S & F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified of type 410 SP–31, 9.00m long complete all as specified. Note: Earth work Excavation, PCC, Coping will be measured and paid separately. Rate quoted by the contractor is deemed to be inclusive of two coats of aluminium paint over a coat of red oxide primer, embedded portion in concrete shall be treated with tarring and sanding.
Supply and lay Bricks, common burnt clay building bricks, sub–class "B", Designation 75 in trenches for cable protection complete all as specified and as directed.
M & L for Dry river sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supplying and Laying PVC insulated, sheathed Multistranded flexible copper conductor cable of size 3 Core, 4 Sq.mm including testing complete all as specified and as directed.
S & F Energy efficient & Long life Street Light Luminaire, of not less than 7000 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F Factory made FRP Junction Box of size 276 X 366 X 186mm with IP 66 Protection and including MCB, SP, 6 Amps, B Curve, 240 Volts [1 Nos] and one number heavy duty Four Way Connector for incomer and outgoing cable, suitable for Pole mounting and fixed with clamps made out of 40 X 3mm flat iron with suitable nuts, bolts, gland lugs etc duly painted with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Supply, plantation and developing of Carpet Grass including necessary earthwork excavation to a depth not exceeding 30cm in any type of soil, removing the Weeds, Roots and Vegetation, filling of Good Earth [Without Moorum content] and having suitable pH and EC as recommended for Saline Water conditions [3 Parts], Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. [1 Part] and watering etc. and applying Soil Pesticide, transplanting of Carpet Grass including cost of Good Earth, Manure, Pesticides, Grass etc. complete all as specified.
Supply, plantation and developing of Ashoka Plant [height of plant not less than 1.20m above ground level and of age 6 Months] with proportional girth, evergreen species including preparation of ground up to 0.45m deep and of size 450 X 450mm and filling of Good Earth [Without Moorum content] and having suitable pH and EC as recommended for Saline Water conditions [3 Parts], Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. [1 Part] and watering etc. complete all as specified and as directed.
Supply, plantation and developing of Gulmohar Plant [height of plant not less than 1.20m above ground level and of age 6 Months] with proportional girth, evergreen species including preparation of ground up to 0.45m deep and of size 450 X 450mm and filling of Good Earth [Without Moorum content] and having suitable pH and EC as recommended for Saline Water conditions [3 Parts], Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. [1 Part] and watering etc. complete all as specified and as directed.
Supply, plantation and developing of Jamun Plant [height of plant not less than 1.20m above ground level and of age 6 Months] with proportional girth, evergreen species including preparation of ground up to 0.45m deep and of size 450 X 450mm and filling of Good Earth [Without Moorum content] and having suitable pH and EC as recommended for Saline Water conditions [3 Parts], Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. [1 Part] and watering etc. complete all as specified and as directed. Note for Serial Item No. 71, 72, 73 & 74: [a] Good Earth shall be well sieved to pass 90% through IS sieve of 10mm size, free from stone rubbish like lumps, stones and other foreign materials suitable for gardening. The soil shall be fresh from quarry. The colour of soil generally be red and as directed by Engineer-in-Charge. [b] Manure shall be well decayed, well dried, well powdered, without clabs and free from stones, dried grass and rubbish materials. The colour of manure shall be black and shall be screened at site using IS designation 4.75 Sieve. [c] Rate quoted is deemed to be including the cost of Removal of excavated material [Soil] to a distance exceeding 250m and not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
PHASE – II [Schedule "A" Part – II]: Maintenance of Arboriculture Works during First Year of Defect Liability Period [i.e. 12 Months], Outsourcing of Services for Operation of Sewage Treatment Plant as provided under this contract as per Serial Item No. 2 of this BoQ / Schedule "A" Part – I for Five Years [i.e. 60 Months] after successful Completion of work under Phase – I and Comprehensive Maintenance of Sewage Treatment Plant as provided under this contract as per Serial Item No. 2 of this BoQ / Schedule "A" Part – I for Two Years [i.e. 24 Months] after successful completion of Defect Liability Period:
Maintenance of Arboriculture / Plants / Grass as provided under Serial Item No. 71, 72, 73 & 74 of BoQ by weeding, hosing, saucer melding once in every 15 days, planting new Plants / Grass in place of dead Plants / Grass of same species and height with out any extra cost to the department and as directed complete during Defect Liability Period complete all as specified and as directed. Note: Rate quoted shall be deemed to include for all labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading / spraying organic manure, chemical fertilisers, pesticides to the required extent complete all as specified.
Outsourcing of services for operation and maintenance of Sewage Treatment Plant of capacity 100 Cu.m / Day installed at INS Viswakarma, Visakhapatnam as provided under this contract as per Serial Item No. 2 of the BoQ, during First Year after successful Completion of work under Phase – I complete by providing services of One Skilled Technician / Operator [ITI Qualified] and One Helper with 3 years relevant experience and trained in Operation and Maintenance of Sewage Treatment Plant in One Shift of 08 Hours per day including Sunday and Holiday including maintaining conveyance and communication system like mobile phone etc. and minor consumables and expandable items, tools for smooth and efficient operation of Sewage Treatment Plant to the entire satisfaction of users / department complete all as specified and as directed. Note: [a] To take care of housekeeping, environmental cleanliness of Area up to 20m all around installation shall be kept absolutely neat and clean and free from vegetation. [b] To maintain all installations provided under this contract as per IE Rules / Standard Engineering Practice and maintenance of Installation Log Books and Maintenance Register. [c] The staff employed shall be having proper uniform as approved by GE.
All as per Serial Item No. 76 but Second Year after successful Completion of work under Phase – I complete all as specified and as directed.
All as per Serial Item No. 76 but Third Year after successful Completion of work under Phase – I complete all as specified and as directed.
All as per Serial Item No. 76 but Fourth Year after successful Completion of work under Phase – I complete all as specified and as directed.
All as per Serial Item No. 76 but Fifth Year after successful Completion of work under Phase – I complete all as specified and as directed.
Comprehensive Maintenance of Sewage Treatment Plant of capacity 100 Cu.m / Day installed at INS Viswakarma, Visakhapatnam as provided under this contract as per Serial Item No. 2 of the BoQ including all consumable materials / chemicals [Chemical such as Sodium Hypo Chlorite and any other chemical as required, Oil and Grease required for operation of the Plant] during Fourth Year after successful Completion of work under Phase – I complete all as specified and as directed.
Comprehensive Maintenance of Sewage Treatment Plant of capacity 100 Cu.m / Day installed at INS Viswakarma, Visakhapatnam as provided under this contract as per Serial Item No. 2 of the BoQ including all consumable materials / chemicals [Chemical such as Sodium Hypo Chlorite and any other chemical as required, Oil and Grease required for operation of the Plant] during Fifth Year after successful Completion of work under Phase – I complete all as specified and as directed.
Note for Serial Item No. 81 & 82: The quoted rates shall be deemed to include the following operation: [a] Preventive and breakdown maintenance of all the equipment by regular oiling, greasing changing of gland packing, replacement of nuts and bolts etc. during the period of work order. [b] To take care of housekeeping, environmental cleanliness of Area all around up to 20.00m all-round the STP and the area shall be kept absolutely neat and clean. [c] To provide chemicals such as Sodium Hypo Chlorite and any other chemical required, oil and grease required for operation of the plant. [d] To maintain the installations provided under this contract as per IE Rules / Standard Engineering Practice. [e]The Sludge generated by the Sewage Treatment Plant shall be disposed by the contractor as per manufacture's instructions, OEM directives and as per instructions of the Engineer-in-Charge. [f] Spare parts if any, required for Operation / Maintenance of Sewage Treatment Plant during the currency of defect liability period shall not be included in the rate of this item. The cost of spare parts to be replaced for operation maintenance of Sewage Treatment Plant shall be borne by the contractor as per conditions of the contract. [g] Periodical maintenance shall be carried out by the authorised representative of the original equipment manufacture [OEM] of the Sewage Treatment Plant. [h] The Contractor shall be responsible for safe custody of the lab instruments glass work. Shortage, breakage etc. and the cost shall be borne by them during Operation and maintenance. [i] Electricity and water for operation of the plant will be supplied by the Department free of Cost.
A.S. ENGINEERS AND CONTRACTORS
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
CIVILEC ENGINEERING WORKS
SVS PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .