Loading…
Loading…
Tender Value
₹1.7 L
EMD Value
₹3,440
Closing Date
30 Sept 2026, 6:00 pm3d left
Executive Engineer Rew Baramulla
REW BARAMULLA
Internal Electrification of Panchayat Ghar Najibhat including internal electrical and External electrification and Allied works Under ADP-PRI Block Wagoora 2026-2027
2026_RDPR_325076_5
228/Xen/Rew/Bla/2026-27 Dated 17/09/2026
Open Tender
Electrical Works
Percentage
45 days
Baramulla
Please refer Tender documents.
2 documents required · 2 mandatory
₹200
Executive Engineer REW Baramulla
₹3,440
17 Sept 2026
17 Sept 2026
1 Oct 2026
17 Sept 2026
30 Sept 2026
17 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/exhaust fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit/Channel(Including its supply and fixing alongwith acessories) with modular switch(Anchor roma urban /eq.make),base plate ,cover plate ,suitable modular GI box etc as required and earthing , with 1.5 sqmm (Havells/Legrand/roma urban/Eq.make as per ISi Standard Note The GI boxes can be of different sizes of Modular Boxes and Modular Switches sizes of Modules to O for lights/fans/exhaust fans and the Modular Boxes are included with this point rate and some points on FF are existing and needs an acessories installation only. | 42 | Points | 775 | ₹32,550 |
| 2 | Wiring for circuits/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor Havells/Anchor/Eq.make),single core cable in recessed medium class PVC conduit/Channel (Including its supply and fixing alongwith acessories) as required.3x2.5 sq mm for lighting and UPS ckts alongwith loopwiring for earthing by 2.5 sqmm from nearest heating point to the room .Note The overall length will be divided by 3 to arrive at the Ckt meter length and ckt will be 2x2.5 sqmm from MCB DB to room and looping of earth by 2.5 sqmm from 4 sqmm earth wire of room to other sockets etc | 70 | Ckt meter | 311 | ₹21,770 |
| 3 | Wiring for circuits/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor Havells/Anchor/Eq.make),single core cable in recessed medium class PVC conduit/Channel (Including its supply and fixing alongwith acessories and making good the surface)as required.2x4 sq mm+1x4 sq mm. earth wire for heating ckts Note This includes Three wires (Phase , Neutral and earth ) and 1 Ckt meter is equivalent to 3 meters. | 80 | Ckt meter | 373 | ₹29,840 |
| 4 | Supply of fixing of Suitable GI Box (not for panelling rooms) with Modular Plate and cover in front on surface or in recess including providing and fixing of 3 pin 16/32 amp /230 v AC modular socket and 16/32 amp modular switch(Anchor Ro urban/SSK NV/Havens /Eq.make) for heating and inv in out. | 12 | No | 550 | ₹6,600 |
| 5 | Supply of fixing of Suitable GI Box(not for panelling rooms) with Modular Plate and cover in front on surface or in recess including providing and fixing of 3 pin 5/ 6 amp /230 V AC modular socket and 5/6 amp modular switch(Anchor Ro urban/SSK NV /Havens /Eq.make) | 22 | No | 450 | ₹9,900 |
| 6 | Supply installation testing and commissioning of 1200 mm dia sweep Ceilng fan of standard make alongwith GI box and required acessories(mlnimum 1 star) | 7 | No | 2,050 | ₹14,350 |
| 7 | Supply of fixing of 6 amp /230 V AC fan dimmer step type 2 module with cover plate Anchor Ro urban/SSK NV/Havells /Eq.make. | 7 | No | 350 | ₹2,450 |
| 8 | SITC of 150-200 mm dia Sweep metallic Exhaust Fan with ceiling rose of standard make. | 1 | No | 1,650 | ₹1,650 |
| 9 | SITC of Recessed/surface mounted LED 15 watts 1'x1' panel light made of CRCA with PS diffuser. Fixture should have minimum efficacy at System level >=100 lumens/watt. Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance, CCT up to 6500K (SDCM<5), THD<10% at full load, CRI >80, PF >0.95 and an operating Voltage Range of 140 - 270 Internal Surge Protection 2.5KV. Luminaire should have SDCM<5. | 6 | No | 950 | ₹5,700 |
| 10 | Supply, Installation, Testing and commissioning of 12/15 watt LED surface mounted Down lighters ,having almunium body and minimum lumens 100 lm/w incl making of necessary Connections. | 24 | No | 715 | ₹17,160 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.30 MB
BOQ_1097370.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .