Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.8 Cr+₹20.9 L (8.04%)Admitted-Finance | ₹2.8 Cr+₹20.9 L (8.04%) | L2 | Admitted-Finance |
| 3 | L3₹3.0 Cr+₹40.5 L (15.6%)Admitted-Finance | ₹3.0 Cr+₹40.5 L (15.6%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | JVS ENGINEERING AND CONSTRUCTIONS PRIVTE LIMITED L1 | SRI DURGA ENGINEERING WORKS L3 | JMS Constructions L2 |
|---|---|---|---|---|---|---|
| 0.00General Notes: 1) Item no. 1 to 5 shall be carried out by specialised agency having experience in chemical resistant tiling works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable. 2) Item no. 6 to 9 shall be carried out by specialised agency having experience in PU/epoxy/special flooring works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable. 3) The contractor shall follow relevant IS codes/technical specifications for execution of work. 4) The contractor shall maintain good workman ship and follow safe working procedures during the work. 5) Rates shall be inclusive of Scaffolding for all items for all heights and depths. 6) Before laying of chemical resiatnt tiling, PU flooring etc as per item no. 1 to 9, the condition and suitability of substrate shall be checked for recieving the tiling/flooring and if required suitable test shall be conducted for the asessing the condition and strength of substrate at no extra cost and as directed by EIC. 7) Contractor shall provide Distribution Board and 4C X16 sq.mm cable of required length at their own cost if required for obtaining temporary power supply from the department. The DB and power cable shall be as per the specifications of NFC. 8) Contractor shall fill the requisition form for providing temporary power supply and details of any equipment to be used at site (dewatering pump, cutting machine, drilling machines, etc) shall be indicated in the proforma annexed to requisition form. 9) Contractor shall employ a licensed electrician to carryout electrical connections /terminations, measurement of earth pit resistance, insulation resistance of their installation and intimating the same to the department & also earthing shall be ensured throught existance of power supply. Intimation shall be given after completion of work for disconnection of supply and safe isolation of DB with last energy meter reading. | ||||||
| 1.00Providing corrosion resistant treatment to floors and wall by bitumen primer conforming to IS 158 with chemical resistant unpolished vitrified tiles of required thickness mentioned below confirming to IS:4457 (Endura of M/s.. H & R Johnson India limited) to resist corrosion action of nitric acid (HNO3) up to 60% concentration, caustic tlie 40% concentration, organic solvents (also to water in open areas which requires acid resistant polyester mortar), or any other chemical including preparing the surfaces, hacking and cleaning etc. complete as per specifications and as per IS 4457 : Latest Edition and as directed by engineer-in-charge to suit the above requirements and the thickness as mentioned below as per by manufacturer's recommendations, relevant standards and as directed by engineer-in-charge. Note: The work shall be carried out by specialised agency having experience in chemical resistant tiling works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable. | ||||||
| 1.01 | 20 mm thick tiles of approved size and shade using potassium silicate bedding mortar as per IS:4832, curing the joints with 20 to 25% HCL, pointing the joints using carbon filled Sulphur cement in floors and with CNSL mortar in walls. | 530 | SQM | 4,600 ₹24,38,000 | 3,800 ₹20,14,000 | 3,160 ₹16,74,800 Lowest |
| 1.02 | 12 mm thick tiles of approved size and shade using potassium silicate bedding mortar as per IS:4832, curing the joints with 20 to 25% HCL, pointing the joints using carbon filled Sulphur cement in floors and with CNSL mortar in walls. | 620 | SQM | 3,100 ₹19,22,000 | 3,050 ₹18,91,000 | 2,300 ₹14,26,000 Lowest |
| 1.03 | 20 mm thick tiles of approved size and shade using CNSL bedding mortar and pointing the joints using Furane as per specified in IS:4832. | 20 | SQM | 4,800 ₹96,000 Lowest | 4,800 ₹96,000 Lowest | 5,400 ₹1,08,000 |
| 1.04 | 12 mm thick tiles of approved size and shade using CNSL bedding mortar and pointing the joints using Furane as per specified in IS:4832. | 20 | SQM | 3,500 ₹70,000 Lowest | 3,800 ₹76,000 | 5,200 ₹1,04,000 |
| 1.05 | 20 mm thick tiles of approved size and shade using Epoxy bedding mortar and pointing the joints using Epoxy as per specified in IS:4832. | 20 | SQM | 4,800 ₹96,000 Lowest | 5,600 ₹1,12,000 | 6,800 ₹1,36,000 |
| 1.06 | 12mm thick tiles of approved size and shade using Epoxy bedding mortar and pointing the joints using Epoxy as per specified in IS:4832. | 20 | SQM | 3,400 ₹68,000 Lowest | 4,800 ₹96,000 | 6,500 ₹1,30,000 |
| 2.00 | Providing corrosion resistant treatment to the floors, skirting and pedestals with acid resistant bricks of size 230x115x38 mm thick as per IS :4800 to resist corrosion action of nitric acid (HNO3) up to 60% concentration, caustic lie 40% concentration and organic solvents using potassium silicate bedding mortar as per IS:4832,curing the joints using carbon filled Sulphur cement including preparing the surfaces, cleaning etc. complete as per specifications and as per latest version of IS:4800 and as directed by engineer-in-charge to suit the above requirements and the thickness as mentioned as per by manufacturer's recommendations, relevant standards and as directed by engineer-in-charge. | 850 | SQM | 2,800 ₹23,80,000 Lowest | 3,700 ₹31,45,000 | 4,100 ₹34,85,000 |
| 3.00 | Providing corrosion resistant treatment to the floors, skirting and pedestals with acid resistant bricks of size 230x115x38 mm thick as per IS :4800 to resist corrosion action of caustic lie 40% concentration and organic solvents using epoxy bedding and pointing mortar as per IS4443 (latest revision) including preparing the surfaces, cleaning etc. complete as per specifications and as per latest version of IS:4800 and as directed by engineer-in-charge to suit the above requirements and the thickness as mentioned as per by manufacturer's recommendations, relevant standards and as directed by engineer-in-charge. | 250 | SQM | 3,100 ₹7,75,000 Lowest | 5,600 ₹14,00,000 | 6,900 ₹17,25,000 |
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
29 Jun 2026, 2:00 pmClosed
Chief Engineer and DCE (CED, PD and EP)
Civil Engineering Division, Nuclear Fuel Complex, Hyderabad-500062.
Chemical resistant tiling, specialized floorings and miscellaneous civil works at various areas of NFC Hyderabad.
2026_NFC_909913_1
C/1431/2026
Open Tender
Civil Works
Item Rate
NFC, Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹6.0 L
24 Aug 2026
23 May 2026
30 Jun 2026
23 May 2026
29 Jun 2026
26 May 2026
23 May 2026 - 25 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0General Notes: 1) Item no. 1 to 5 shall be carried out by specialised agency having experience in chemical resistant tiling works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable. 2) Item no. 6 to 9 shall be carried out by specialised agency having experience in PU/epoxy/special flooring works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable. 3) The contractor shall follow relevant IS codes/technical specifications for execution of work. 4) The contractor shall maintain good workman ship and follow safe working procedures during the work. 5) Rates shall be inclusive of Scaffolding for all items for all heights and depths. 6) Before laying of chemical resiatnt tiling, PU flooring etc as per item no. 1 to 9, the condition and suitability of substrate shall be checked for recieving the tiling/flooring and if required suitable test shall be conducted for the asessing the condition and strength of substrate at no extra cost and as directed by EIC. 7) Contractor shall provide Distribution Board and 4C X16 sq.mm cable of required length at their own cost if required for obtaining temporary power supply from the department. The DB and power cable shall be as per the specifications of NFC. 8) Contractor shall fill the requisition form for providing temporary power supply and details of any equipment to be used at site (dewatering pump, cutting machine, drilling machines, etc) shall be indicated in the proforma annexed to requisition form. 9) Contractor shall employ a licensed electrician to carryout electrical connections /terminations, measurement of earth pit resistance, insulation resistance of their installation and intimating the same to the department & also earthing shall be ensured throught existance of power supply. Intimation shall be given after completion of work for disconnection of supply and safe isolation of DB with last energy meter reading. | |||||
| 1Providing corrosion resistant treatment to floors and wall by bitumen primer conforming to IS 158 with chemical resistant unpolished vitrified tiles of required thickness mentioned below confirming to IS:4457 (Endura of M/s.. H & R Johnson India limited) to resist corrosion action of nitric acid (HNO3) up to 60% concentration, caustic tlie 40% concentration, organic solvents (also to water in open areas which requires acid resistant polyester mortar), or any other chemical including preparing the surfaces, hacking and cleaning etc. complete as per specifications and as per IS 4457 : Latest Edition and as directed by engineer-in-charge to suit the above requirements and the thickness as mentioned below as per by manufacturer's recommendations, relevant standards and as directed by engineer-in-charge. Note: The work shall be carried out by specialised agency having experience in chemical resistant tiling works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable. | |||||
| 1.01 | 20 mm thick tiles of approved size and shade using potassium silicate bedding mortar as per IS:4832, curing the joints with 20 to 25% HCL, pointing the joints using carbon filled Sulphur cement in floors and with CNSL mortar in walls. | 530 | SQM | - | - |
| 1.02 | 12 mm thick tiles of approved size and shade using potassium silicate bedding mortar as per IS:4832, curing the joints with 20 to 25% HCL, pointing the joints using carbon filled Sulphur cement in floors and with CNSL mortar in walls. | 620 | SQM | - | - |
| 1.03 | 20 mm thick tiles of approved size and shade using CNSL bedding mortar and pointing the joints using Furane as per specified in IS:4832. | 20 | SQM | - | - |
| 1.04 | 12 mm thick tiles of approved size and shade using CNSL bedding mortar and pointing the joints using Furane as per specified in IS:4832. | 20 | SQM | - | - |
| 1.05 | 20 mm thick tiles of approved size and shade using Epoxy bedding mortar and pointing the joints using Epoxy as per specified in IS:4832. | 20 | SQM | - | - |
| 1.06 | 12mm thick tiles of approved size and shade using Epoxy bedding mortar and pointing the joints using Epoxy as per specified in IS:4832. | 20 | SQM | - | - |
| 2 | Providing corrosion resistant treatment to the floors, skirting and pedestals with acid resistant bricks of size 230x115x38 mm thick as per IS :4800 to resist corrosion action of nitric acid (HNO3) up to 60% concentration, caustic lie 40% concentration and organic solvents using potassium silicate bedding mortar as per IS:4832,curing the joints using carbon filled Sulphur cement including preparing the surfaces, cleaning etc. complete as per specifications and as per latest version of IS:4800 and as directed by engineer-in-charge to suit the above requirements and the thickness as mentioned as per by manufacturer's recommendations, relevant standards and as directed by engineer-in-charge. | 850 | SQM | - | - |
| 3 | Providing corrosion resistant treatment to the floors, skirting and pedestals with acid resistant bricks of size 230x115x38 mm thick as per IS :4800 to resist corrosion action of caustic lie 40% concentration and organic solvents using epoxy bedding and pointing mortar as per IS4443 (latest revision) including preparing the surfaces, cleaning etc. complete as per specifications and as per latest version of IS:4800 and as directed by engineer-in-charge to suit the above requirements and the thickness as mentioned as per by manufacturer's recommendations, relevant standards and as directed by engineer-in-charge. | 250 | SQM | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.84 MB
Biddocument4GCCSCC.pdf
Tender Documents • 1.19 MB
Bidderdeclaration.pdf
Tender Documents • 0.46 MB
FinancialBidDocument.pdf
Tender Documents • 0.92 MB
Biddocument5TECHFORMSATOH.xls
Tender Documents • 0.08 MB
Biddocument7_AERBControlofWorks.pdf
Tender Documents • 0.27 MB
05spec5.pdf
Tender Documents • 2.56 MB
6_CementGodownSketch.pdf
Tender Documents • 0.98 MB
7_SafetyAccessNFC.pdf
Tender Documents • 3.30 MB
8_AERBControlofWorks.pdf
Tender Documents • 0.27 MB
9_SafetyLifelineNFC.pdf
Tender Documents • 1.38 MB
10_VAOI.pdf
Tender Documents • 0.69 MB
01spfI.pdf
Tender Documents • 6.73 MB
02spfII.pdf
Tender Documents • 3.31 MB
03spfIII.pdf
Tender Documents • 5.06 MB
04spfIV.pdf
Tender Documents • 4.74 MB
TenderDrawings.pdf
Tender Documents • 0.94 MB
BOQ_956322.xls
BOQ • 0.37 MB
DBandCableSpecifications.pdf
Tender Documents • 0.11 MB
PowerSupplyRequisitionForm.pdf
Tender Documents • 0.94 MB
DateextnCorrigendum.pdf
PDF • 0.78 MB
DateCorrigendum.pdf
PDF • 0.79 MB
GCCSCC.pdf
PDF • 1.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .