| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC CHIEF ENGINEER OP KANGRA ZONE HPSEBL DHARAMSHALA | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC L-1 bidder | |
| 2 | Not Admitted-Fee/PreQual/Technical A CLASS GOVT ELECTRICAL CONTRACTOR VPO CHOBIN TEHSIL BAIJNATH DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹20.2 L
EMD Value
₹20,222
Closing Date
22 Mar 2022, 11:00 amClosed
SE Kangra
SE (OP) Circle , HPSEBL ., Kangra
Civil work
2022_HPSEB_58082_1
SEOP 41/2021-22
Open Tender
Civil Works
Turn-key
180 days
Kangra
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹20,222
Yes
20 Sept 2022
16 Mar 2022
24 Mar 2022
16 Mar 2022
22 Mar 2022
16 Mar 2022
Amount
Excavation in foundation, trenches etc. in earth work lift up to 1.5m stacking the exacavated soil not more than 3m clear from the edge of exacavtion and returning the stacked soil in 15cm layer, when required into plinth sides of foundation etc. consolidated is deposited layer by ramming and watering and then disposing of all surplus earth within 20m lead as directed by Engineer-in-charge.
Providing and laying cement concrete 1 : 4 :8 (1 cement : 4 sand : 8 graded stone aggregate 20 mm nominal size ) and curing complete excluding cost of form work in in foundation and plinth in all leads and lifts..
Random rubble masonary/ polygonal rubble masonary(uncoursed/brought to courses) with hard stone of approved quality in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement, 6 sand, 12 graded stone aggregate 20mm NS) in cement mortar 1:6 ( 1cement, 6 sand) in all leads and lifts.
Providing and laying cement concrete 1:1.5:3( 1 cement, 1.5 sand, 3 graded stone aggregate 20mm NS) and curing complete excluding cost of formwork and reiforcement in all leads and lifts.
Foundations, footings bases of columns and the like and mass concrete.
Columns, pillars posts and struts upto floor two level.
Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and cantilever upto floor two level
Stair cases (except spiral stair cases) excluding landing but including preparing of the surface and finishing of nosing upto floor two level.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30*30*5mm so as to give a fair finish including centering, shutering, strutting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4mtrs and removal of the same for in-situ-reinforced concrete & plain concrete work in
Foundation, footings basis of columns etc. and mass concrete.
Columns, pillars, posts and struts Square, rectangular or polygonal in plan.
Beams, cantilever, girders and lintels. Sides and soffits of beams, beam haunching, cantilever
Flat surface such as soffits of suspended floor roof, landing upto 200mm in thickness
Stair cases with sloping or stepped soffits excluding landing.
Providing mild steel/Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level.
Boulder filling dry hand packed tightly as in wire crate / soling under floors in all leads & lifts.
Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size will rammed and consolidated and grouted with fine sand including preparation of ground.
Prov. Plinth protection 50mm thick in cement concrete 1:3:6 (1 cement, 3 sand, 6 graded stone aggregate 20mm NS).
Brick work using common burnt clay building bricks in superstructure in cement mortar 1:6 (1 cement: 6 sand) First class brick
Half brick masonary in common burnt clay building brick in cement mortar 1:4 (1 cement, 4 sand)
Providing and fixing anodised aluminium work for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/Neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically where ever required including cleast angle, aluminium, snap beading for glazing/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and the directions of Engineer-in-Charge. (Prepainted brown or White coloured)
P/F aluminium work for door, windows, ventilators & glazed partition frames with excruded built up standard tubular & other section of approved make confirming to IS 733 & IS 1285 anodised transparent or dyed
P/F annodised aluminium work for shutters of doors, windows & ventilators including providing and fixing hinges and making provision for fixing of fitting where ever required
Providing and fixing aluminium anodised powder coated grill of required pattern to existing window/ventilator
Prelaminated board bwp phenol bonded exterior/interion grade both sides.12mm thick
Providing and fixing fly proof galvanised M.S. wire gauge of IS gauge designation 85 g with wire of dia 0.56 mm to windows and clerestory windows
P/F glazing in aluminium door, window, ventilator shutters and partition etc. with PVC/ neoprens gasket etc. complete as per drawing with glass panes of 5.5mm thickness
P/F anodized aluminium sliding door bolt anodized colour & shade with bolts & nuts screws etc. complete (250*16mm)
P/F aluminium tower bolts ( berrel type) anodised transparent or dyed to required shade and colour with screws etc. complete
For doors (200*10mm)
For Windows (150*10mm)
P/F aluminium handles anodized transparent or dyed to required colour & shade with necessary screws etc. complete
For doors (125mm)
For windows (100mm)
P/F Double action spring hinges with necessary screws 150mm
Providing and fixing bright finished hard drawn hooks and eyes 150 mm
15mm cement plaster in single coat on rough side of brick/ stone masonary for interior plastering upto floor two level including arrises, internal rounded angles. Chamfers or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:5 (1 cement, 5 sand)
15mm cement plaster in single coat on fair side of brick/ stone masonary for interior plastering upto floor two level including arrises, internal rounded angles. Chamfers or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:4 (1 cement, 4 sand)
6mm cement plaster to ceiling in cement mortar 1:3 (1 cement, 3 sand) complete in all heights, leads and lifts.
Providing and fixing 10mm thick anti skid water proof stain and impect resistent heavy duty vetrified tiles Nitco or equivalant 600x600mmx10mm manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3 (1 cement : 3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete.
P/L spartic ceremic tiles 5.5mm thick in flooring (300*300mm size ) treads of the steps laid on a bed of 12mm thick cement mortar 1:3 (1 cement, 3 sand) finished with flush pointing in white cement
White glazed tiles 6 mm thick in skirting risers of steps and dado 12 mm thick cement mortar 1:3 (1 cement :3 sand) and jointed with cement slurry.
Applying Birla white wall care putty over plastered surface after thoroughly brushing the surface free from mortar droppings and other foreign matter, sand papered smooth to give final matt finish to the surface complete.
Distempering (two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surfaces to give an even shade over and including a priming coat with distemper primer of approved brand and also including preparing the surface even and sand papered smooth.
Applying one coat of distemper primer of approved brand and manufacture on wall surfaces after thoroughly brushing the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials
Steel work welded in built up section, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of red lead in grating framed guard bars
Providing and fixing moulded hand rail of MS hollow pipe 50 mm dia welded in straight length over MS flat at top of vertical balusters including one coat of red oxide priming coat complete (MS flat and balusters of railing shall be measured and paid for separately).
Painting (two coats) excluding priming coat on new steel and steel based surface after and i/c preparing the surface by thoroughly cleaning, oil, grease, deit and other foreign matter sand papering and stopping with ready mixed paint other than white
Constructing course rubble hammer dressed "U" shape open surface drain with side wall 15 X 22 cm in cement mortar 1 : 6 (1 cement : 6 sand) and inside plastering with cement plaster 1 : 3 (1 cement : 3 sand) including earth work and laying 10 cm cement concrete in 1 : 5 : 10 (1 cement : 5 sand : 10 graded stone aggregate of 40 mm nominal size) and 7.5 cm cement concrete 1 : 2 : 4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and finished with a floating coat of neat cement complete as per standard design.
Providing and fixing on wall face PVC(D-Plast) rain water pipes of working pressure not less than 4.5 kg/sqm including filling the joints with approved adhesive complete
100mm dia pipes
Providing and fixing on wall faces PVC (D-Plast) accessories for rain water pipes including filling the joints with approved adhesive complete PVC Plain bend 100mm dia
Providing & fixing vitreous China wash down, water closet squatting pan (Indian type W.C pan) size 580mm of Cera/Hindware/Jal or equivalent brand (Earth work, bed concrete, foot rest and trap to be measured and paid for separately). Orissa Pattern
Providing and fixing PVC coloured/white automatic flushing cistern of Cera/Hindware/Jal or equivalent brand with a pair of PVC / C.I. or mild steel brackets, complete with fitting including PVC syphonic apparatus, mosquito proof lid, PVC union and coupling for connections with inlet, outlet and over flow pipes including cutting holes and making good the same (overflow pipe to be measured and paid for separately) 10 liters net capacity (Cera or Hindware make)
Providing and fixing vitreous China wash basin (Cera/Hindware/Jal or equivalent brand) with single hole for pillar tap with C.I. or M.S. brackets painted white including cutting holes and making good the same but excluding fittings Flat back 550 x 400 mm (Cera or Hindware make)
Providing and fixing 32 mm dia, PVC waste pipe flexible (coil type) length not less than 800 mm.
Providing and fixing PTMT Hi quality duel hanging bath room mirror of 4 mm thick glass of approved quality and colour with steel screws and rawl plugs etc complete :- size 600 x 450 mm
Providing and fixing C.P. brass towell rail (Cera/Hindware/Jal or equivalent brand) complete with C.P. brass brackets fixed to wooden plugs with C.P. brass screws. 600 x 20 mm
Providing and fixing C.P. brass soap dish (Cera/Hindware/Jal or equivalent brand) with C.P. brass brackets fixed to wooden cleats with C.P. brass screws.
Providing and fixing C.P. Brass bib tap (Cera/Hindware/Jal or equivalent brand) with Capstan head 15 mm dia (Cera or Hindware make)
Providing and fixing C.P. Brass pillar tap (Cera/Hindware/Jal or equivalent brand) with Capstan head 15 mm dia(Cera or Hindware make)
Providing and fixing C.P. stop cock 15 mm dia (Cera/Hindware/Jal or equivalent brand) (Cera or Hindware make)
Providing and fixing PVC connection pipe with brass unions 300/450 mm length 15 mm nominal bore
Providing and fixing brass full way valve with wheel
15 mm nominal bore
25 mm nominal bore
Providing and fixing PVC floor trap ISI marked of self cleaning design including cost of cutting and making good the walls and floors etc. complete 110 x 75 mm (Diplast or Vectus make)
Providing and fixing to wall ceiling and floor galvanised mild steel tubes (heavy grade) tube fittings and clamps including making good the wall, ceiling and floor. (TATA or Jindal make)
15 mm nominal bore
25 mm nominal bore
Providing and fixing high pressure PVC spigot and socket waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete (Diplast or Vectus make)
110 mm dia
75 mm dia
Providing and fixing PVC Collar, ISI marked including fixing with approved adhesive etc. complete(Diplast or Vectus make)
110 mm dia
75 mm dia
Providing and fixing PVC plain bend ISI marked including fixing with approved adhesive etc. complete (Diplast or Vectus make)
110 mm dia
75 mm dia
Providing and fixing PVC clamps ISI marked of approved design with steel screws and rawl plugs etc. complete.
110 mm dia
75 mm dia
Providing and fixing 100 mm dia chromium plated grating of superior quality for floor, gully or nahani trap
Providing and fixing PVC floor trap ISI marked of self cleaning design including fixing with approved adhesive, cost of cutting and making good the wall and floors etc. complete. 110 mm X 90 mm.
Providing and fixing stoneware gully trap grade 'A' complete with C.I grating, brick masonry chamber in cement mortar 1:5 and water tight C. I. cover with frame of 300mmx300mm size (inside) the weight of cover to be not less than 4.53kg and frame to be not less than 2.72kg. 100mmx100mm size P type
Constructing brick masonry chamber for under ground C.I. inspection chamber and bends with common burnt clay building bricks in cement mortar 1 : 5 (1 Cement : 5 Sand) C.I. cover and frame (light duty) 355 x 610 mm internal dimensionsr, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) RCC top slab with 1 : 2 : 4 mix (1 Cement : 2 Sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1 : 5 : 10 mix (1 Cement : 5 Sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 15 mm thick with cement mortar 1 : 3 (1 Cement : 3 Sand), finished with a floating coat of neat cement on walls and bed concrete etc. complete Inside dimensions 455 x 610 x 450 mm deep single pipe line
Providing and fixing C.I. Covers Light duty rectangular 455 x 610mm with frame weight 38 Kg.( Single seal pattern):-
Providing and fixing PVC water storage tank of ISI : 12701 marked, G. I. inlet and outlet connection, 15 mm nominal bore ball valve and mosquito proof PVC cover with locking arrangement including hoisting up to all heights above ground level (Vectus or Diplast make)
1000 liters net capacity tank
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. 209 Group C.
213 Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. 217 2x2.5 Sq. mm.
214 Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- 602 25 mm. dia
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
216 2x1.5 Sq. mm.
217 2x2.5 Sq. mm.
218 2x4.0 Sq. mm.
219 2x6.0 Sq. mm.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-
806 2 modules (78mmx78mmx50mm)
807 4 modules(140mmx78mmx50mm)
808 6 modules(205mmx78mmx50mm)
809 8 modules (120mmx135mmx60mm)
810 12 modules (205mmx135mmx60mm)
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
909 S.P. 5/ 6 Amps one way Modular switch.
911 Bell push, Modular.
912 S.P. 15/ 16 Amps one way Modular switch.
914 6 pin,15/16 Amps Modular socket outlet.
913 5 pin, 5/ 6 Amps Modular socket outlet.
929 Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.
936 Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
933 Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
2613 Providing and fixing following surface mounting T5 luminaries with powder coated CRCA sheet steel housing, mirror optics reflector, electronic ballast, decorative end caps, suitable for 28 watt FTL (T5), complete with all accessories (excluding the T-5 Tube), connections, testing and commissioning etc. as required. 2 x28 watt-FTL(T5) (Category-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- 2502 Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- 2505 Exhaust Fan, Heavy duty, 300 mm sweep
2711 Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Bulk head fitting, CFL type (Category-A)
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset,neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including Earthing etc. as required:- 1809 Double door-12 way
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- 1701 Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1718 63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1730 63 Amps. Cat-A.
1901 Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.( but without charcoal or coke and salt ) complete as required.
1902 Extra for using salt and charcoal for pipe earth electrode complete as required.
1909 Supplying and laying 6 SWG G.I. wire at 0.50 mtr. Below ground level for earth electrode conductor, including soldering etc. as required.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .