Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC NEELANKAVIL HOUSE GURUVAYUR | L1 | Accepted-AOC COUNCIL ACCEPTED | |
| 2 | L2₹11.2 L+₹25,621.88 (2.34%)Rejected-Finance KOOLIYATT HOUSE KOTTAPADI | IDUKKI | KERALA | 685501 | L2 | Rejected-Finance COUNCIL REJECTED | |
| 3 | L3₹11.3 L+₹30,570.38 (2.79%)Rejected-Finance | L3 | Rejected-Finance COUNCIL REJECTED | |
| 4 | L4₹11.4 L+₹48,524.08 (4.43%)Rejected-Finance CHATTIKKAL HOUSE KOTTAPPADI | KOTTAYAM | KERALA | 686001 | L4 | Rejected-Finance COUNCIL REJECTED | |
| 5 | L5₹11.6 L+₹63,089.38 (5.76%)Rejected-Finance SREEVALSAM MAMMIYOOR GURUVAYUR | GURUVAYUR | KERALA | L5 | Rejected-Finance COUNCIL REJECTED |
Tender Value
₹12.4 L
EMD Value
₹31,120
Closing Date
1 Nov 2025, 2:00 pmClosed
ASSISTANT ENGINEER
OFFICE OF AEE
GENERAL-PROVIDING NEW YARD FOR TOURIST FACILITATION CENTRE-GURUVAYUR MUNICIPALITY-General Civil Work
2025_LSGD_815413_1
Etdr 62/2025
Open Tender
Civil Works - Buildings
Item Rate
240 days
GURUVAYUR
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹31,120
11 Nov 2025
27 Oct 2025
3 Nov 2025
27 Oct 2025
1 Nov 2025
27 Oct 2025
Amount
15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar
15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD366136/2025-2026:DAR 60.7.1 - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD366191/2025-2026:Filling up low lying and waterlogged areas with local material/quarry muck spreading in layers ,levelling the top at site and consolidation by ramming etc complete for improving the CBR value subgrade
OD366190/2025-2026:Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. (i) Using naturally occuring gravel
OD366198/2025-2026:Supplying and laying interlocking Cement Concrete paver block tiles 80mm or nearest size thickness, minimum strength M40[ conforming to IS 15658:2006, for Medium traffic Low volume roads] including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock CC paver block tiles in lines and levels as per the directions of the departmental officers at site, inclusive of all cost & conveyance charges etc. complete
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD366214/2025-2026:Supplying and fixing at site Aluminium Composite Panels (ACP) of approved make and colour certified for exterior applications, 3mm thickness with 28 to 30mm microns PVDF coating confirming to ASTM standard with top aluminium skin of 0.25mm and with a bottom aluminium skin of 0.25mm with service coating of polyester paint, laminated to a centre core of 2.5mm single recycled low density polyethylene material. The panels shall be cut to sizes of required grid dimensions with the site condition. The panel shall be fixed on pre-fabricated frame work using 38mm*25mm*1mm thick Aluminium extruded sections of approved make joined with standard cleats and fasteners. The gaps formed between the panels shall be sealed with silicone sealant. The rate inclusive of cost and conveyance of all materials labour for erection, hire charges of scaffolding etc. complete.
OD366415/2025-2026:Boring Overburden with suitable size Bit to accommodate well casing pipe of internal Diameter not less than 150 MM for various strata by Rotary Method
OD368632/2025-2026:ISI marked new submersible electric driven motor pump set and accessories, including fitting charge.
OD366414/2025-2026:Supplying and fixing 150mm dia PVC pipe 6 kgf/cm2 (casing pipe)
OD366907/2025-2026:Engaging Electrician for Electrician works
OD366908/2025-2026:Engaging Man Coolie
OD366909/2025-2026:Welder
OD366910/2025-2026:Plumber
Sudheerkumar (BID ID -2422582)
Subashkumar CP (BID ID -2420438)
BIJU (BID ID -2419956)
P Nandakumar (BID ID -2419339)
Bidder Name
P Nandakumar
Sudheerkumar
Subashkumar CP
BAIJU N J
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1365064.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
SBD.pdf
Tender Documents • 2.05 MB
PRE.pdf
Tender Documents • 0.26 MB
AFFIDA.pdf
Tender Documents • 0.24 MB
FOT.pdf
Tender Documents • 0.25 MB
BOQ_1365064.xls
BOQ • 0.32 MB
INTEGRITY.pdf
Tender Documents • 0.23 MB
EPAYMENT.pdf
Tender Documents • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .