Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC ERATTU VALAPPIL HOUSE KADANCHERY PO KALADY MALAPPURAM PO 679 582 | MALAPPURAM | KERALA | 679582 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical KERALA | IDUKKI | KERALA | 685501 | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | MANOJ KUMAR T V L2 | JOSHI E V L1 |
|---|---|---|---|---|---|
| 1.00ANGANWADI RENOVATION | |||||
| 1.00 | 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar | 2.1 | cum | 680 ₹1,425.28 | 619 ₹1,297.42 Lowest |
| 1.00 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 0.17 | cum | 2,350 ₹406.55 | 2,138 ₹369.87 Lowest |
| 1.00 | 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 0.4 | cum | 12,400 ₹4,910.4 | 11,421 ₹4,522.72 Lowest |
| 1.00 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 31.68 | kilogram | 120 ₹3,801.6 | 96 ₹3,041.28 Lowest |
| 1.00 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 4.2 | sqm | 750 ₹3,150 | 648 ₹2,721.6 Lowest |
| 1.01 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 24 | sqm | 350 ₹8,400 | 314 ₹7,536 Lowest |
| 1.01 | 15.19:Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge. | 108 | kg | 6 ₹648 | 3 ₹324 Lowest |
| 1.01 | OD355268/2025-2026:Providing and Fixing Precoated galvanised iron profile sheets(Shape and Pitch of corrugation as approved by engineer in charge)0.35mm(+0.05%),total coated thickness with zinc coating 120gms per sqm as per IS:277, in 240 mpa steel grade ,5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by engineer in charge.The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55 mm)with EPDM seal, complete up to any pitch in horizontal /vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape Wherever required. | 54.73 | sqm | 580 ₹31,743.4 | 530 ₹29,006.9 Lowest |
| 1.01 | OD412382/2025-2026:Steel work for purlin/single section with MS pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and
bolted with special shaped washers etc. complete | 148.2 | kg | 150 ₹22,230 | 133 ₹19,710.6 Lowest |
Tender Value
₹2.5 L
EMD Value
₹6,130
Closing Date
23 Jan 2026, 3:00 pmClosed
ASSISTANT ENGINEER KALADY GP
ASSISTANT ENGINEER KALADY GP
Pro No101/25-26 RENOVATION OF ANGANWADI CNO 55
2026_LSGD_827887_2
AE/LID EW/KLDY/2025-2026
Open Tender
Civil Works - Buildings
Item Rate
KALADI GRAMAPANCHAYAT OFFICE
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
Yes
₹6,130
Yes
25 Feb 2026
15 Jan 2026
24 Jan 2026
15 Jan 2026
23 Jan 2026
15 Jan 2026
ANGANWADI RENOVATION
15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
15.19:Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.
OD355268/2025-2026:Providing and Fixing Precoated galvanised iron profile sheets(Shape and Pitch of corrugation as approved by engineer in charge)0.35mm(+0.05%),total coated thickness with zinc coating 120gms per sqm as per IS:277, in 240 mpa steel grade ,5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by engineer in charge.The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55 mm)with EPDM seal, complete up to any pitch in horizontal /vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape Wherever required.
OD412382/2025-2026:Steel work for purlin/single section with MS pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD355269/2025-2026:Providing and fixing 150mm wide,square cut PVC 4kgf/cm2 rain water gutter pipe with iron brackets with 25x5 mm size flat, screws and washers etc,including making necessary connections with rain water pipes etc.complete.
51.18.12.7:Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately) External work - 65 mm nominal dia
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
17.10.2.1:Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink without drain board610x510 mm bowl depth 200 mm
17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
13.98.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
13.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
OD413335/2025-2026:Supplying and Providing PVC door with frame 50x40x2mm and shutter with shutter frame 60 mm wide and 25mm thick PVC hollow panels including all charges etc.
50.18.9.12.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall
50.18.9.13.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 12 Kgf/ cm2- External work- exposed on wall
50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
50.18.9.16.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.67 MB
BOQ_1389583.xls
BOQ • 0.32 MB
viewsbdmerged.pdf
Tender Documents • 1.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .