| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.4 L+₹1.4 L (3.71%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹42.4 L+₹4.4 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
19 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 c/o 56 APO
Provn of certain sanctioned work at Rajouri under AGE E/M of GE 862 EWS
2021_MES_415410_1
GER-75/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹80,000
Yes
13 Mar 2021
22 Jan 2021
22 Feb 2021
22 Jan 2021
19 Feb 2021
5 Feb 2021
60 days
Amount
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for fdn etc and n. exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for fdn etc and n. exc 10sqm on plan and getting out in soft/disintegrated rock complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Taking up or down GI tubing 20 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
Taking up or down GI tubing 25 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
Taking up or down GI tubing 50 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
Refixing only 20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
Refixing only 25 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
Refixing only 50 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
25 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
40 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
50 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
Dismanlting old valve chamber and construction of brick masonry new valve pit chamber of size 1200mmx1200mmx1200mm (internal) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonry wall of 23mm thick built in CM 1:6 rendering in CM 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:6 and finished fair and even supply and fix 3.15 mm thick MS sheet cover fixed on 50mmx50xx6mm thick angle iron frame embbeded in PCC coping with locking arrangement and 01 Nos 50mm size 4 lever lock with key in duplicate standard size and MS hold fast and handle made out of 25x6mm flat iron applying two coats of synthetic enamel paint of approved shade over a coat of pirmer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed.
Gun metal/globe valve with iron wheel head screwed on both sides for iron pipes of 20mm internal dia complete all as specified and directed.
Gun metal/globe valve with iron wheel head screwed on both sides for iron pipes of 25mm internal dia complete all as specified and directed.
Gun metal/globe valve with iron wheel head screwed on both sides for iron pipes of 40mm internal dia complete all as specified and directed.
Gun metal/globe valve with iron wheel head screwed on both sides for iron pipes of 50mm internal dia complete all as specified and directed.
Cutting, threading and inserting tee for taking new branch connection from existing pipe line of any size for the pipe size 50mm including necessary GI fittings ISI marked complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable drawing in and including non metalic rigid PVC casing & caping complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated bakalite sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly compete all as specified and directed.
Description all as per Serial item No 22 above but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
Description all as per Serial item No 22 above but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Serial item No 22 above but for one 3 pin 15 Amp socket outlet independent with cable 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper conductor cable as earth lead complete all as specified and directed.
Switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
Socket 2 in 1, 3 pin 5 amp flush type complete all as specified and directed.
Socket out let 2 in 1, multipurpose 5 & 15 Amp flush type complete all as specified & directed.
Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed. Make Bajaj /Usha/havells/CG
Bell push flush type single pole one way 5 amps 240 volts complete all as specified and directed.
Supply and fixing in replacement buzzer Ding Dong AC, 230 Volts, single pole complete all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 20 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTTB4F20WLED P/W or its equivalent technically and commercially in Philips/Havells/Bajaj/Crompton
Street light fitting LED 30 watt made up of grey powder coated pressure die cast aluminium housing having IP66 control gear and lens compartment. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non requirerd SUGRG. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTP-30-CDL or its commercially and technically equivalent in Bajaj/Philips/Havells/C&S Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
Decorative LED Bollard light with opal diffuers and aluminium reflector outdoor type LED Bollard light 8W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable complete all as specified and directed. Havells cat No CONEBLS8WLED830PSYMTOPC) or equivalent model in Philps
Post top lantern light fitting 35 watts with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement on top surface of boundary wall or on pillar by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface complete all as specified and directed.
GI bracket pipe of size 25mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clams 2 Nos of 25 cm long duly to the bracket pipe and painting to MS camps and fixing with necessary suitable nuts, bolts and washers and removing of old unserviceable item complete all as specified and directed. Make:- Havells Cat Part No RUBYPT35WLED757PSYMTOPC or equivalent in crompoton/Bajaj.
FRP looping box of size 250x200x105mm with connector and comprising oF MCB SP 6 Amps, ISI marked 240 V complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall etc and including removing old unserviceable item complete all as specified and directed. Make - National/Sintex
Supply and fix in replacement high efficacy 2'x2' recess LED flat panel light 36W LED 2700/3000K (warm white) edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:- Havells/Bajaj/Crompton/Halonix.
Factory made, sheet metal enclosure, double door, 415 volts, AC, TPN, vertical distribution board, 4 way, painted with epoxy based powder coated suitable for mounting MCCB as incomer or rating upto 160 Amps, FP, 16-36 KA and MCB SP/TP as outgoings and complete with and including 200 Amps rated copper buspar, neutral bar, connecting cable links with and including top and bottom removable gland plate, complete with IP43 protection complete all as specified and directed. Make:- I No 18 to 19- standarad/Havells/ABB.
Sheet metal enclosure MCB distribution board in repairs single pole & neutral 430 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .(Note-MCBs will be measured and paid for separately).
MCCB 63 Amps four pole adjustable thermal and magnetic setting type,10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and directed.
MCB SP 240 volt any rating from 5 to 32 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
MCB SPN 240 volts 40 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
Sheet metal enclosure single pole and neutral with two pin and earth plug and socket with one single pole MCB 20 amp complete all as specified and directed.
Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor as earth continuity conductor drawn through and including PVC casing and capping of size 25mm width or above accessories fixed on wall/floor/ceiling etc all as specified and as directed. Note: 03 runs of cable and one run of casing capping shall be measured as one unit.
Sub main wiring complete with 2 runs of 6 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 6sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor as earth continuity conductor drawn through and including PVC casing and capping of size 25mm width or above accessories fixed on wall/floor/ceiling etc all as specified and as directed. Note: 03 runs of cable and one run of casing capping shall be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed Note: Punned thickness of sand shall be measured and paid.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed
Supplying and laying reinforced precast concrete cable cover, class LV, type 1 flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Supply, installation, testing and commissioning of 100 KVA copper wound servo voltage controlled automatic voltage stabilizer conforming to IS with and including following components and specifications :- (a) Input Voltage-300 to 480 (Phase-Phase) (b) output Voltage - 415 volt +/- 2.5 % (Phase-Phase) (c) Frequency - 50 HZ. (d) Capacity overload - 20 % over load for one hour (e) Protection- overload and short circut through micro process or based MCCB. (f) Outdoor type, IP-55 certification required. (g) Unbalanced type. (h) Suitable for all power factor. (j) Cooling shall be ONAN. (k) Efficiency shall be more than 95 % (l) Adequate size of stabilizer using heavy duty TATA steel. (m) Speed of correction more than 8 volt per second. (n) Suitable capacity of AC synchronous servo motor (o) Suitable quantity of fresh transformer oil for adequate cooling of make:- Power oil/Savita. (p) Quality of copper of purity 99.97 % pure. (q) Slector switch to check input and output voltage. (r) Auto/mannual switch to operate the stabilizer in manual mode with the help of push buttons, in case of failure in automatic circuit. (s) Heavy duty aluminum bus bar for input and output connections. (t) Unidirectional roller wheels for easy portablity. (u) Cooling tube/ radiators for cooling of oil (v) Lifting lugs for lifting (w) Oil level gauge. (x) First filling of new transformer oil as per IS-335, filtered and tested for die electric strength not less than 40 KV at 2.00 mm gap between testing electrode
Supply, installation, testing and commissioning of 75 KVA copper wound servo voltage controlled automatic voltage stabilizer conforming to IS with and including following components and specifications :- (a) Input Voltage-300 to 480 (Phase-Phase) (b) output Voltage - 415 volt +/- 2.5 % (Phase-Phase) (c) Frequency - 50 HZ. (d) Capacity overload - 20 % over load for one hour (e) Protection- overload and short circut through micro process or based MCCB. (f) Outdoor type, IP-55 certification required. (g) Unbalanced type. (h) Suitable for all power factor. (j) Cooling shall be ONAN. (k) Efficiency shall be more than 95 % (l) Adequate size of stabilizer using heavy duty TATA steel. (m) Speed of correction more than 8 volt per second. (n) Suitable capacity of AC synchronous servo motor (o) Suitable quantity of fresh transformer oil for adequate cooling of make:- Power oil/Savita. (p) Quality of copper of purity 99.97 % pure. (q) Slector switch to check input and output voltage. (r) Auto/mannual switch to operate the stabilizer in manual mode with the help of push buttons, in case of failure in automatic circuit. (s) Heavy duty aluminum bus bar for input and output connections. (t) Unidirectional roller wheels for easy portablity. (u) Cooling tube/ radiators for cooling of oil (v) Lifting lugs for lifting (w) Oil level gauge. (x) First filling of new transformer oil as per IS-335, filtered and tested for die electric strength not less than 40 KV at 2.00 mm gap between testing electrode
Supply , install, testing and commissioning of factory made outdoor type floor mounted LT panel board cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 160 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.15 mm CRCA sheet and 40 X 40 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings components:- (a) MCCB 160 Amp 4 Pole 25 KA-01 No as incoming (b) MCCB 100 Amp 3 Pole, 16 KA-02 Nos (Outgoing) (c) MCCB 63 Amp 3 Pole, 16 KA-02 Nos (Outgoing) (d) Digital combimeter (7in1) with four digit LED display-01 No (e) Indicating lamp LED type-01 set in incoming phases (f)Internal wiring with PVC insulated copper conductor multistrand cable 1100 volt grade IS 694 marked of appropriate gauge including all copper luggages
Supply , install, testing and commissioning of factory made outdoor type floor mounted LT panel board cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.15 mm CRCA sheet and 40 X 40 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings components:- (a) MCCB 160 Amp 4 Pole 36 KA-01 No as incoming (b) MCCB 100 Amp 4 Pole, 36 KA-01 No (Outgoing) (c) MCCB 63 Amp 4 Pole, 36 KA-01 No (Outgoing) (d) Digital combimeter (7in1) with four digit LED display-01 No (e) Indicating lamp LED type-01 set in incoming phases (f) Internal wiring with PVC insulated copper conductor multistrand cable 1100 volt grade IS 694 marked of appropriate gauge including all copper luggages (g) spare space for MCCB 63 Amp- 01 No
Electrical operated 240 volts 50 Hz RO plant stainless steel commercial type including cost civil works complete with all accessories & fittings etc. System of purification capacity 500 ltrs/hour of make KENT Model KENT grand star or its equivalent of Aquaguard/Eruka/RWT with following specification:- (a) Power input 100-300 Volts. (b) Power output 60W. (c) Double purification by RO and UV with TDS controller kills the impurities and bacteria with advanced purification system. (d) LED indicator & UV alarm. (e) Primary filter of minimum one ltr capacity & piping. Note- After completion of work RO plant shall be handed over to the unit for further maintance of plant
Supply, Laying, connecting and testing in replacement of service cable of size 16 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular complete all as specified and directed.
Rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, double layered, cylindrical vertical with closed top hoisted and fixed in position of capacity 2000 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including ball valve of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minium weight 15mm-142 gms complete all as specifed and directed.
Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 to 260 V with output voltage stabilized at 230 volts with accuracy ± 2.5% 50 Hz of capacity 5 KVA complete all as specifed and directed.
Framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed.
Supply, install and commissioning of solar street light fitting 24 watt LED light with 12 Volt 35 AH battary, 80 Wp solar PV module, solar panel, fixing arrangement on 5 mtr TUB, hot dip galvanised tubular pole above ground plole including all accessories and adequate quality of PCC work with excavation complete all as specified and directed. Make :- Havells Cat Part No-LHSTARU7AANI024 or equavalent in TATA solar power system/Global Urja Limited. Note:- (a) The rate of excavation and PCC work ate quoted in deemed rates. (b) The prior approval of GE required before placing the order of solar panel, light fitting and connections, pole etc.
Supply, installation and testing of floor standing split type air conditioner 2.0 TR capacity of 5 star rating for all weather condition with cordless remote control, single phase 240 volts complete with all accessories includintg making cable connection by providiing three core 4 sqmm copper conductor cable PVC insulated, sheathed of adequate length as required at site and initial fitting of refrigerant gas drain pipe and cables etc and making good the disturbed surface by matching with existing adjoining surfaces complete all specified and directed. Make :- LG/Voltas/Blue star/Samsung/Daikin.
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electricity operated suitable for 230 volts, 50 hz, AC supply system complete with porcelen/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 25 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electricity operated suitable for 230 volts, 50 hz, AC supply system complete with porcelen/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 50 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
Supply and fixing ceiling fan 1200mm sweep with 5 star rating electrical operated 220 volts 50 HZ AC supply complete with hook arragnement for hanging with canopy and rod complete with all accessories including regulator etc Make - Bajaj or USHA /Havells/CG
15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
15mm bore stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Bib tap cast copper alloy with crutch or butterfly handle, screwed for iron pipe, suitable for 15 mm bore complete all as specified and directed.
PVC connection 15 mm x 450 mm including nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S PARSHOTAM KUMAR GUPTA
SATVIR GUPTA ENGINEER and CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .