Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.0 LAccepted-AOC 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹55.7 L+₹1.8 L (3.25%)Rejected-Finance JAIN SADAN MAHAL ROAD SHIVPURI DISTT SHIVPURI MP | SHIVPURI | SHIVPURI | MADHYA PRADESH | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹57.2 L+₹3.2 L (5.95%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹58.6 L+₹4.6 L (8.48%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Not lowest |
Tender Value
₹72 L
EMD Value
₹83,000
Closing Date
19 Dec 2021, 6:00 pmClosed
CWE AF Ambala
HQ CWE AF Ambala Ambala Cantt-133001
SPECIAL REPAIR TO CERTAIN BUILDINGS OF TECHNICAL AREA AND DOMESTIC AREA AT AF STN AMBALA UNDER GE (AF) AMBALA
2021_MES_481975_1
CWE/AF AMB/AMB-32/2021-22
Open Tender
Miscellaneous Works
Item Rate
270 days
Ambala Cantt
For enlisted in MES Class C and category a i and for unenlisted refer NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE AF Ambala
₹83,000
Yes
1 Feb 2022
14 Oct 2021
21 Dec 2021
14 Oct 2021
19 Dec 2021
5 Dec 2021
14 Oct 2021 - 1 Nov 2021
Amount
Taking down chowkhats or frames not exceeding 1.5 sqm each with shutters (without taking off shutter from frames) removing from site including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and directed
Description all as per item No 1.00 here-in-above but chowkhats or frames exceeding 1.50sqm but not exceeding 4.0sqm.
S&F second class, hard wood(hollock), glazed and skeleton shutter, 35mm thick, factory made, open rebated and prepared to receive glass/guage etc, without sash bars, mitred and rebated, with edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/guage etc, sizes of stiles, rails etc as specified in Section 8, clause 8.24(a) of SSR part-I complete all as specified and directed.
S&F factory made, second class, hard wood(hollock), plain framed, panelled shutter (two panel), 35 mm thick with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F factory made solid PVC moulded door shutter(with wood free EPS), 28mm to 30mm thick(stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, fixed in frame at site as per specification & drawing given in SSR Part–II complete all as sepcified and directed.
S&F factory made, solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, fixed in opening as per specification & drawing given in SSR Part–II complete all as specified and directed.
S&F 100 mm size, Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed
S&F 150 mm long, aluminium, anodized, barrel tower bolt of extruded section complete all as specified & directed
S&F 150 mm size, aluminium alloy, handle, cast type, anodized fixed complete all as specified and directed
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F mild steel framed work as in door or gate of angle or other sections with gusset plates, rails, braces etc, using ornamental design as approved complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and purpose made hinges or steel hanging door fittings exclusive of steel sheeting or other covering, running rails and guides and hanging, fastening and fixing complete conforming to Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed.
S&F factory made Box type steel window, double shutter, glazed and wire gauzed with side hung shutters including box type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02 Nos for each leaf) duly welded, complete with glazing bars dovetailed or welded including MS fillets, including welding of mild steel grill complete all as specified and directed. Notes: - (i) Windows shall be fabricated as per drawing No. TD-219 Sh 1/3 to 3/3 dated 02 Jan 2007 and these drgs may be referred from GE office or from the office of CWE (AF) Ambala. (ii) Glazing, Wire cloth & MS grills shall be measured and paid separately . (iii) Painting to window shall be measured and paid separately however one shop coat primer included in quoted rates. (iv) Double shutter meant for providing glazed shutter as well as wire gauged shutter on outside & inside of the frame respectively. Both the shutters shall be measured as one unit. (v)Steel window shall comply with IS 1038-1983 &. Rolled steel sections for fabrication shall conform to IS 7452-1990
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed.
M&L preparation of new wood and wood based surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over & including one coat of pink primer complete all as specified and directed.
M&L preparation of new steel and iron based surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide primer complete all as specified and directed.
M&L preparation of previously untreated/new steel and iron based surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F sheet glass 3.0 mm thick ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
S&F figured glass, pin head type, 3.0 mm thick and glazing with oil putty in squares exceeding 0.50 sqm in each pane complete all as specified and directed.
M&L in repair cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), outlet dia 75 mm complete all as specified and directed.
S&F in repair 15 mm bore stop valves, concealed type, cast copper alloy, fancy type, chromium plated with long shank and cup, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe including cutting chases required for concealing complete all as specified and directed.
S&F in repair brass, chromium plated, fancy type 15mm bore, hot & cold central hole basin mixture without pop-up waste system including 15mm bore 450mm long braided hose etc. complete as specified and directed.
S&F in repair bib taps, 15 mm bore, cast copper alloy, brass chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed.
S&F in repair chromium plated, brass, tubular towel rail, fancy type, with fancy type brass CP brackets on both sides, 20mm dia, D type 600mm long between flanges , fixed with screws complete all as specified and directed.
S&F in repair PVC low level flushing cistern, white, valveless syphonic action type 10 litre capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, complete all as specified and directed.
S&F in repair vitreous china urinal, half stall type, white including grating, union for discharge pipe, flush pipe, waste pipe & PTMT urinal spreader(minimum weight 60 gm) fixed to water supply pipe etc. complete all as specified and directed.
S&F in repair vitreous china urinal partition slab, white, size 310mm x 700mm terminating about 40cm above floor line complete all as specified and directed.
S&F in repair vitreous china wash hand basin, flat back or angle back type, white, size 550mm x 490mm including 32mm bore PVC waste pipe, CP waste fitting & one pair of mild steel angle iron brackets of suitable size fixed as in counter slab complete all as specified and directed.
S&F in repair brass, chromium plated, fancy type, shower rose 125mm size, with or without swivel joints, fixed to 15 mm bore steel pipe or union, complete all as specified and directed.
S&F in repair chromium plated, cast copper alloy, soap dish any type complete all as specified and directed.
S&F in repair corner shelf, 300mm x 300mm, made out of 5 to 7mm thick superior quality sheet glass with CP bracket and railing fixed complete all as specified and directed.
S&F in replacement vitreous china wash down water closet (Pedestal pattern), white, including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom, aluminium hinging devices, CP fancy type EWC jet (health faucet) 15 mm bore with 1 mtr long PVC connection pipe including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. complete all as specified and directed.
S&F in repair 15 mm bore stop valves/angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
S&F in repair PVC connection 450mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified and directed
S&F in repair curtain rod made out of 20mm dia mild steel pipe having wall thickness 1.0mm, powder coated, colour/pattern(as approved) complete all as specified & directed
S&F plastic finial decorated type, any colour /pattern, best quality to suit the 20mm dia curtain rod and fixed at the end of curtain rod with suitable adhesive including mild steel prepainted brackets to hold the curtain rod and fixed to wall (concrete/brick) with the help of 2 Nos. 50mm long steel screws and rawl plug complete all as specified & directed Note: One plastic finial and one Bracket shall be measured as one unit.
Refixing after cleaning and removing with bleaching powder to all scale, sludge, mud, algae and dirt etc from tanks, capacity exceeding 250 ltr but not exceeding 500 ltr from mouths of circulting pipes etc and washing with clean water including writing in words with synthetic enamel paint as "CLEANED ON (date)" complete all as specified and directed.
S&F in replacement rotational moulded polythene(PVC) water storage tank, HDPE, off white colour, triple layered , cylinderical type fixed and hoisted in position on roof, at any height, of capacity 500 ltr and making connections with 20 mm GI pipe inlets & outlets complete including locking arrangements and 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gram) complete all as specified and directed.
S&F in repair 20 mm bore stop valves, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layers on roof and rubbish off the premises including stacking of servicable brick tiles complete all as specified and directed.
Demolition of mud phuska on roofs, any thickness including mud plastering & leeping (whether full thickness removed or only a part thereof) and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
M&L 50mm thick average thickness, PCC 1:2:4, type B1, using 20 mm graded mechanically crushed stone aggregates over roof slab as in padding in slope to make good the depressions/undulations complete all as specified and directed.
M&L 15 mm thick plastering in cement mortar 1:4 on cleaned RCC roof slab surfaces, sides of parapet etc mixed with water proofing compound (WPC) as per manufacturer's instructions, finished even and fair complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L 40 mm thick brick tiles laid on roofs, jointed and grouted flush in cement mortar 1:3 mixed with linseed/crude oil @ 5% by weight of cement over and including 15 mm thick screed bedding in cement mortar 1:6 complete all as specified and directed.
Description all as per item No 44.00 here-in-above but except brick tiles. Note: Old serviceable brick tiles retrieved from item No. 40.00 here-in-before shall be used after cleaning and washing.
M&L PCC 1:2:4, type B-0, using 12.5 mm graded mechanically crushed stone aggregates as in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work complete all as specified and directed. Note : The quoted rates include for use of formwork (straight or curved).
M&L Atactic Polypropylene (APP) polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighting not less than 3.0 kg per sqm, black finish reinforced with non-woven polyster (Weight not less than 150 gms per Sqm), with properties of high penetration and centre core consisting of 90 micron, high molecular high density polyethylene (HMHDPE) film consisting of five layers with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.30 Ltr per Sqm, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per Sqm below APP complete all as specified and directed . Notes:- (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) Security deposit against Water proofing treatment shall be calculated as per the scales laid down for calculating Earnest Money Deposit enhanced by 25% on the total amount of Water proofing treatment work (BOQ item No 40.00 to 48.00) and shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor' risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect.
Supply only integral water proofing compound (WPC) complete all as specified and directed.
Dismantling of 100mm/75mm dia cast iron or PVC drain pipes, jointed in cement mortar and taking out from floors or walls or from trenches complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed in any length with rubber ring joints, fixed to wall/floor or laid in trenches complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius provided without access door complete all as specified and directed.
Taking down or up steel tubing and connections for refixing or removal from site for 15 mm bore pipe complete all as specified and directed.
Taking down or up steel tubing and connections for refixing or removal from site for 20 mm bore pipe complete all as specified and directed.
S&F galvanized iron water tubes 15 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling with and including cutting chasing whereever required or laid in floor complete all as specified and directed.
Description all as per item No 54.00 here-in-above but except GI water tubes. Note: Old serviceable GI water tubes retrieved from item No. 52.00 here-in-before shall be used.
S&F galvanized iron water tubes 20 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling with and including cutting chasing whereever required or laid in floor complete all as specified and directed.
Description all as per item No 56.00 here-in-above but except GI water tubes. Note: Old serviceable GI water tubes retrieved from item No. 53.00 here-in-before shall be used.
M&L 75mm thick PCC 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed. Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length. (ii) 30 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume.
Demolition of cement concrete (unreinforced) in ground floor ( below or above ground level) & pavings not exceeding 15 cm thickness and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
M&L for cutting/chipping the spalling concrete surfaces of chajjas/roof protection etc. and trimming & cleaning the surface to recieve gunting and providing pressure gunnting average 20mm thick in PCC 1:2:4 type B-0 and finishing the concrete surface with 15mm thick plastering in cement mortar 1:3 even & smooth without using extra cement including welding the reinforcement to existing reinforcement complete all as specified and dirceted Note: (i) Reinforcement shall be measured seperately. (ii) Necessary scaffolding as required at site shall be provided by contrator without any extra cost and shall remove the same on completion of the work.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, rubbish off the premises complete all as specified and directed.
M&L coloured, non-skid, jointfree, ceramic tiles, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in cement mortar 1:4, complete all as specified and directed.
M&L jointfee glazed desinger ceramic coloured tiles of size 300mm X450mm, 6mm to 7mm thick on vertical surface as in skirting/dado, set and jointed in neat cement slurry & pointed in white or coloured cement to match the surface over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L coloured, non-skid, jointfree, ceramic tiles, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in cement mortar 1:4, complete all as specified and directed.
M&L Vitrified ceramic tiles, coloured, light shade, 10 mm thick, square/ rectangular, polished, area of each tile not exceeding 0.36 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed or bedding layers in cement mortar 1:4, complete all as specified and directed.
M&L mild steel TMT bars, 10 mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water including removal of debries to distance not exceeding 500 mtr complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:6, finished even and smooth without using extra cement on fair faces of brick or concrete surfaces as in wall complete all as specified and directed.
M&L rendering 5 mm thick in cement mortar 1:3, finished even and smooth without using extra cement on fair faces of concrete surfaces as in ceiling/soffits complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:4, finished even and smooth without using extra cement on fair faces of brick or concrete surfaces as in wall complete all as specified and directed.
M&L for rough cast plaster including 15mm thick rendering in cement mortar 1:3 on brick wall or concrete concrete surfaces complete all as specified in SSR Part - I clause 14.22 complete all as specified and directed. Note : Rough cast finish to be as below :- After applying the under coat of cement mortar 1:3 and while it is still in plasic state the rough cast mixture consisting of crushed stone or fine gravel agg (which is generally of size between 6 to 12mm depending on the texture required ) mixed with course sand and cement in the ratio of 1 : 1 : 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger agg are thoroughly covered.
Demolition of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles complete all as specified and directed.
M&L Brick work with sub class B bricks of old size, straight or curved on plan exceeding 6 mtr mean radius, built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including rubish off the premises to a distance not exceeding 500 mtr complete all as specified and directed
M&L 100mm thick PCC 1:2:4, type B1, using 20mm graded mechanically crushed stone aggregate as in floor & pavings including finishing even and smooth without using extra cement complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall, applying one coat of wall care putty(3mm thick) to make the surface even & smooth, applying two coats of distemper oil emulsion(1st quality) of approved shade/tint over & including one coat of alkali resistant primer complete all as specified and directed.
M&L preparation of old treated plastered/unplastered surfaces of wall by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, filling holes & cracks and applying one coat of wall care putty(3mm thick) to make the surface even & smooth, applying two coats of distemper oil emulsion(1st quality) of approved shade/tint over & including one coat of alkali resistant primer complete all as specified and directed.
M&L preparation of newly plastered surfaces of ceiling/soffits and applying three coat of white wash complete all as specified and directed.
M&L preparation of old treated plastered/unplastered surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, filling holes & cracks with cement base putty and applying two coat of white wash on ceiling/soffits complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying two coat of weather proof exterior acrylic emulsion paint over & including one coat of alkali resistant primer complete all as specified and directed.
Complete removal of existing treatment of wall and applying two coat of weather proof exterior acrylic emulsion paint over & including one coat of alkali resistant primer complete all as specified and directed.
M&L preparation of newly plastered surface of walls and applying two coats of exterior acrylic emulsion paint in camoflaging pattern of any shade & pattern over & including one coat of alkali resistant primer complete all as spcified and directed. Note for item No. 76.00, 77.00 & 80.00 to 82.00: The colour/shade of finishes shall be approved by GE.
S&F anodised aluminium door made out hollow aluminium section as mentioned below. Each door having 02 Nos disc or D type handle of 200 mm long , 02 Nos aluminium tower bolts of 200mm size, 01 No. mortice lock of six levers with key in duplicate, regulated by double action hudraulic floor door spring, shutters shall partly glazed with 5mm thick tinted glass and partly panelled with 12mm thick both side prelaminated particle board fixed with glazing clips, rubber beading/gasket anodised aluminium beading, screws etc complete all as specified and directed. Chowkhat section size : 101.60mm X 44.45mm, 1.50mm thick Shutter vertical style section size : 83.5mm x 44.45mm, 1.50mm thick Shutter lock rail section size : 101.60mm X 44.45mm, 1.50mm thick Shutter top & bottom rail section size : 83.5mm x 44.45mm, 1.50mm thick
S&F powder coated aluminium anodised window(Three track sliding window) made out hollow aluminium as mentioned below. Each shutter shall have 01 No. aluminium handle of 75mm size and 02 Nos aluminium tower bolt 150mm long. Window shall be glazed with 4.00mm thick tinted glass fixed with glazing clips, rubber beading and anodized aluminium beading etc complete all as specified and as directed. Chowkhat bottom section size : 50.3mm X 26.0mm, 1.20mm thick Chowkhat top & sides section size : 50.3mm X 15.0mm, 1.00mm thick Shutter top & bottom rail section size : 101.60mm X 44.45mm, 1.50mm thick Shutter inner lock rail section size : 37.5mm x 15.0mm, 1.50mm thick Shutter side mid rail section size : 37.5mm x 15.0mm, 1.36mm thick Note for item No. 83.00 & 84.00: (i) The weight of Aluminium sectons shall not be less than 0.55Kg/RM. (ii) Minimum thickness of anodization shall be 15 micron. (iii) The door/window shall be as per drawings/directions of Engingeer-in-charge and drawing may be reffered from GE office.
S&F powder coated anodised aluminium grill of approved design/pattern, mesh size 100mm x 100mm & aluminium bars of 8mm dia using 'U' shape channel 25mm x 12mm, fixed to aluminium frame work complete all as specified and directed.
Dismantling of boarding, any description, fixed in any position with nails complete all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls/floors/ceilings complete all as specified and directed . Note: During taking down of point wiring, electrical fitting such as fan, light fittings, electric meters, , meter box, Gyseser etc. shall be disconnected & shall be reconnected after point wiring and disturbed suface shall be make good as per existing surface. Quoted rate deemed to be included for this aspect.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit 20mm bore(having 2mm wall thickness), medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 1.5 sqmm connected to common earth and earth dolly for one light point, ceiling fan/exhaust fan point & call bell point controlled by one way switch 5/6 amp complete all as specified and directed.
Description all as per item No. 90.00 here-in-above but for one socket outlet point 5/6 amp controlled by one switch on the independent board.
Description all as per item No. 90.00 here-in-above but for one socket outlet point 5/6 amp controlled by one switch on the same board.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 2.5 sqmm with stranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit 20mm bore(having 2mm wall thickness), medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 2.5 sqmm connected to common earth and earth dolly for one socket outlet point 15/16 amp controlled by one switch on the independent board complete all as specified and directed. Note for srl No 90.00 to 93.00 :- (i) Switch, socket outlet, switch socket combination, bell push and fan regulator shall be measured and paid for separately. (ii) Rate quoted shall be inclusive of cutting chases in wall and making good in cement mortar 1:3 & finishing the disturbed surfaces to match with the existing surfaces.
S&F switch piano, flush type, 5/6 amp, single pole, one way complete all as specified and directed.
S&F switch piano, flush type, 15/16 amp, single pole, one way complete all as specified and directed.
S&F socket outlet, flush type, 5 pin, 5/6 amp, 240 volt, complete all as specified and directed.
S&F socket outlet, flush type, 5 pin, 15/16 amp, 240 volt, complete all as specified and directed.
S&F ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S&F lamp holder PVC/Polycarbonate insulated body with back plate suitable for angle/batten fitting complete all as specified and directed.
S&F stepped type electronic fan regulator flush type, single pole 240 volts, 50 Hz, 100 watts, on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
M&L in replacement concealed sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through in & including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match with existing surface complete all as specified and directed. Note :- Two runs of 4 sqmm cable alongwith one run of 4 sqmm cable as earth wire alongwith conduit shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates.
M&L in replacement concealed sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn through in & including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match with existing surface complete all as specified and directed. Note :- Two runs of 6 sqmm cable alongwith one run of 6 sqmm cable as earth wire alongwith conduit shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates.
S&F in replacement LED tube light fitting 1x18 watt fitting four feet length, 230 volts in commmercial channel with powder coated CRCA sheet housing with opal acrylic diffuser for LED with & including LED tubelight with high efficient LED 18/20 watts in aluminium housing with clear & milky diffuser including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and as directed. Note:- LED fitting should have PF>0.95, input voltage 90 to 300 volt, IP-68, LM-80 standard luminaries efficiency 100 lumen/watt.
S&F in replacement Bulk head LED fitting 10 watts fixed to wall/ceiling with FI clamps, nuts, bolts, washers etc with and including LED lamp 10 watts and connecting with twin core twisted flexible copper conductor cable of suitable size not more than one mtr and making necessary connection to make it functional complete all as specified and directed. Note:- LED fitting should have PF>0.95, input voltage 90 to 300 volt, IP-66, LM-80 standard luminaries efficiency 100 lumen/watt.
S&F in replacement indoor decorative LED batten with opal diffuser with inbuilt LED tube 10 watts and driver designed with high transmitting optics for even light distribution IP20 degree protection having length 620mm including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and directed. Note:- LED fitting should have PF>0.95, input voltage 90 to 300 volt, IP-20, LM-80 standard luminaries efficiency 100 lumen/watt.
S&F in replacement 45 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy supported with LM-79/80, cast alluminium alloy housing IP 66 protection, life > 50000 hours, input voltage range 110-240 volts, auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED fitting shall comply with IEC60598/IS10322 including GI bracket made out of 40 mm bore pipe light grade of length not less than 1.2 mtr bent to shape & suitable size of clamps, nuts, bolts, washer, fastner etc. complete all as directed and specified.
S&F in replacement sheet metal enclosure for MCB DBs, 230 volt, single pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 6 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Description all as per item No. 107.00 here-in-above but 8 way.
Description all as per item No. 107.00 here-in-above but 12 way.
S&F in replacement sheet metal enclosure for 4 way MCCB incomer + 12 modules outgoings, vertical triple pole and neutral loadline distrubution board, IP 43, double door type, confirming to IS 8623-III, 160 Amp rated bus bar blanking plates flushed inside the wall including 01 No. incomer MCCB 125 Amp, 415 Volts, 25 KA, 4 pole, 3 phase, with adjustable thermal & fixed magnetic setting and making good the disturbed surfaces complete all as specified and directed.
Description all as per item No. 110.00 here-in-above but including 01 No. incomer MCCB 100 Amp, 415 Volts, 16 KA, 4 pole, 3 phase, with adjustable thermal & fixed magnetic setting.
Supply and fixing in replacement MCB, single pole & neutral, 5 to 40 Amp, C curve, 10 kA capacity, 240 volts complete all as specified and directed.
Supply and fixing in replacement MCB, single pole, 5 to 32 Amp, C curve, 10 kA capacity, 240 volts complete all as specified and directed.
M&L in replacement earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth wire 4.0 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 15 mm bore, light grade including protection pipe GI light grade 20mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion on site complete all as specified and as directed. Notes:- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at No extra cost, till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for walls, shafts, manholes not exceeding 10 Sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose soil complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) as specified in clause 19.75 of SSR Part-I complete all as specified and directed. Note: Sand shall be fine sand as specified in clause 14.5 of SSR Part-I
Supply and laying old size, sub class 'B' common burnt bricks, designated 75, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacement LT XLPE electric cable, 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor, of cross sectional area 50 sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc, complete all as specified and directed.
S&F ceiling fan, copper winding complete with accessories, 1200 sweep, 3 blades, 5 star rated including hanging, connecting with existing point complete all as specified & directed.
S&F heavy duty, BEE 5 star rated, exhaust fan, single phase, 230/240 volt, 300mm sweep, steel body, turbo force, 1400 RPM, totally enclosed heavy duty motor with copper winding including mounting brackets for on wall, grouting of nuts and bolt etc required for fixing fan , making connetions with twisted copper flexible wire 23/0.0076mm complete all as specified and directed.
S&F electric water heater(Geyser) storage type of capacity 25 ltrs, 2000 watts heating element, non corrosion tank, temperature adjustment knob, red & green indicators, NRV, ISI marked, 5 star rated including fixing arrangements with nuts and bolts, grouting with wall complete and making good distrubed surfaces of wall/floor etc, complete all as specified and directed.
S&F galvanized iron water tubes 50 mm bore, medium grade, with all fittings fixed to wall /floor complete all as specified and directed.
M&L point wiring complete with multistranded copper conductor PVC (ZHFR) insulated unsheathed cable 1100 volt grade of size 1.5 sqmm drawn through in & including rigid metiallic steel conduit (ERW) concealed in wall etc including 1.5 sqmm multistranded copper conductor PVC (ZHFR) as earth and connected to earth dolly for Flame proof fitting and flame proof exhaust fan complete all as specified and directed.
M&L point wiring complete with multistranded copper conductor PVC (ZHFR) insulated unsheathed cable 1100 volt grade of size 2.5 sqmm drawn through in & including rigid metiallic steel conduit (ERW) concealed in wall etc including 2.5 sqmm multistranded copper conductor PVC (ZHFR) as earth and connected to earth dolly for Flame proof fitting and flame proof power socket complete all as specified and directed.
S&F in replacement switch flame proof, rotary type with termination box in LM6 16 amp, single pole, 250volt complete all as specified and directed.
S&F in replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 amp, 250 volt, 2P + earth complete all as specified and directed.
S&F LED light fitting 1x20 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F wall mounted fan, AC, single phase 230/240 volts, 450 mm sweep including suitable size of fastner complete all as specified and directed
S&F in replacement test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed with and including 3 nos, 8mm dia, 25mm long hexagonal head screw complete all as specified and directed.
S&F in replacement alumininum strip 25mm x 3.15mm on FRP insulator fixed on wall/MS sheet or floors incl connecting to lightening arrester/earthing/test point strip should be brazed/welded at each joint complete all as specified and directed.
S&F in replacement air termination single pointed aluminium rod 12 mm dia, 300mm long duly fixed/secured with PCC or with GI pipe supports complete all as specified and directed.
M&L PCC 1:3:6, type C-2 (using 40 mm graded mechanically crushed stone aggregates) as in blocks to hold GI extension pipe for air termination rod including necessary form work complete all as specified and directed.
S&F in replacement GI strip 32mm x 6mm on FRP insulator fixed on wall/MS sheet or floors incl connecting to lightening arrester/earthing/test point strip should be brazed/welded at each joint complete all as specified and directed.
S&F sheet metal enclosures powder coated deep drawn DB with clad socket & plug top duly installed netral link adjustable din rail and connecting link with and including one single pole MCB 20 Amp, 'B' curve 240 volts, 10 kA complete all as specified and directed.
Supply, Installation, Testing, and Commissioning of a set of maintenance free tripod earthing system consisting of 3 No. of Copper Bonded Earth Rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x25x3mm for long lasting and connection . Each copper bonded rod and the exothermically jointed busbar both should be CPRI tested on at least 25KA Fault current to ensuring the high current carrying capacity of the system and earth rod should be certified by Underwriters underwriters laboratories confirming to comply with UL467 international standard for grounding and bonding equipment. Each rod should be used with minimum 50kg earth enhancing compound that should be ROHS tested and have passed , Resisitivity of the earth enhancing compond should be less than 0.05 ohm meter - an international standard for Earth Enhancement Compound by NABL accredit Lab complete all as specified and as directed. Note : (i) The rate for interconnection of tripod earth with Copper strip of size 20mm x 3mm and poly carbonate earth pit cover -03 Nos shall deemed to be included in the quoted rates. (ii) The Earth result should be less than 1 ohm for 3 year will be the responsibility of the contractor and no extra cost paymnet will be paid for this and the result will be checked in presence MES Rep. (iii) The earthing shall comply to IS 3043, UL 467, BS/EN 50164-7. (iv)To obtain less than one ohm if a combination two or more earthings are to be interconnected or the length of the electrode is to be increased it shall be measured and paid as one earthing only. (v) Testing of the earth shall be carried out in presence of departmental rep and a report shall be submitted the cost of the same is deemed to be included in the quoted rates.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required copper strip 20mm x 3mm complete all as specified and directed
S&F in replacement off load change over switch, 4 pole, 415 volt, 63 Amp rating with side handle including sheet enclosure complete all as specified and directed.
S&F flame proof Exhaust fan, single phase, size 457mm (18"), speed 1440 RPM, CFM 4000 including making hole in wall of suitable size and with all fixing arrengement including connection complete all as specified and directed.
For Credit schedule refer tender documents.
ANIL CONSTRUCTION CO.
Gupta Enterprises
M/s B.S.Jain
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .