Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.4 L+₹32,161 (4.52%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹7.7 L+₹57,961 (8.14%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹8.3 L+₹1.2 L (16.3%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹9.5 L
EMD Value
₹18,920
Closing Date
26 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
REPAIR /MAINT OF STREET/GARDEN LIGHTS AND ITS CONNECTED ITEMS AT RALAWAS UNDER GE BANAR
2022_MES_559510_1
8822/42/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹18,920
Yes
12 Dec 2022
22 Oct 2022
28 Nov 2022
22 Oct 2022
26 Nov 2022
12 Nov 2022
Amount
M&L for checking/testing of street lights fittings any type fixed on pole to detect the fault and carryout minor repair to make it operational minor fault, like remove carbon,lose connection etc) all as directed by Engineer-in-Charge.
Strip opening and taking down carefully defective/non functional street light fittings of LED's from its existing position from the pole and refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from junction box to driver/ control MCB not working in junction box) of the fitting if the fitting can not be repaired/functionable, the old U/s fitting to be deposited to MES store for reapair and re-assembling and testing complete all as specified and as directed by Engr-in-Charge. Note :- (a) Any other items i.e MCB, flexible cable to be measured and paid separately. (b) Contractor provide Extendable wheel laddar or hydra to carryout repair/replacement and quoted rates shall deemed to inclueds this aspect.
S&F LED street light fitting 60 watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with and twin core twisted flexible copper conductor cable of suitable size and aii acessories complete all as specified and directed at site complete.
Striping out and taking down carefully defective/non functional gate/garden light/post top lantern fittings of LED's from its existing position & refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from control panel to driver) of the fitting if the fitting can not be repaired/functionable, the old fitting to be replaced by new fitting re-assembling and testing complete all as specified and as directed by Engr-in-Charge. Note :- (a)other items i.e flexible cable to be measured and paid separately.
S&F Post top lantern LED type 20 watts 230V AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as directed at site complete.Make:-Philips
Striping out and taking down carefully defective/non functional flood light/bldg security light for > 10m high bldgs of LED's from its existing position and capacity & refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from control panel/distribution box to driver/ control MCB not working in distribution box) of the fitting if the fitting can not be repaired/functionable, the old fitting to be replaced by new fitting and re-assembling and testing complete all as specified and as directed by Engr-in-Charge. Note :- (a) Any other items i.e MCB, flexible cable to be measured and paid separately.
Supply and fix MCB SP 6-32 Amps 230V 10KA 'C' curve and taking down existing unserviceable from its own position and taken as schedule of credit all as specified and directed by Engr-in-Charge.
Supply and fix PVC insulated unsheathed flexible copper conductor flexible cable three core multi stranded 1.5 Sqmm and taking down existing from its own position and taken as credit all as specified and directed by Engr-in-Charge.
Supply and fix thermoplastic cable junction box IP 65 with plain walls of size 210x310x116mm and making suitable size hole for cable entry complete with cable terminals/connectors and other fittings fixed on poles with MS flat iron nut bolts, washers and double compressor metal glands of suitable sizes etc and disconnecting of existing junction box and taken as credit complete all as specified and directed etc all as specified and directed by EIC.
M&L painting of LT/HT steel tubular pole any type of size externaly above foundation and junction box including all MS work with one coat of aluminium paint after scraping /cleaning well the existing surface complete all as specified and directed by EIC. Note :- The item included in the painting 3 Nos 30 cm wide bands black & Yellow synthetic enamel paint in alternate layer upto 1.0 mtr high above foundation and writing the pole No in 5 cm wide on base of yellow colour with HT/LT as per direction of Engr-in-Charge.
Rerouting of existing cable XLPE/PVC Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor cable of following sizes taking out from trench and again laid in trenches/duct/ pipes/ wall and open surfaces all as specified and directed by EIC. Note :-(1) During the laying of cable minor accessories i.e lugs, nut-bolts and steel glands deemed to be fit inclusive in quoted rate.
16 Sqmm 4 core
25 Sqmm 4 core
Supply,fixing and testing in repair/replacement of LED 45W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply,fixing and testing in repair/replacement of LED 75W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply,fixing and testing in repair/replacement of LED 100W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply,fixing and testing in repair/replacement of LED 150W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply and fixing in repair/replacement of LED PCB board for 45/60KW light fitting board thickness 1.6mm for Flood/street/highbay light fittingcomplete with connection as specified as per dirtected
Supply and fixing in repair/replacement of LED PCB board for 90/100KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection as specified as per dirtected
Supply and fixing in repair/replacement of LED PCB board for 150 KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection as specified as per dirtected
Excavation in trenches n. exc 1.5 mtr in depth and not exc. 1.5 mtr in wide and getting out in soft/loose soil for laying of cables all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in hard/ dense soil.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point.
M&L for sand filling in trenches as cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and as directed by EIC. Note :- Punned thickness only shall be measured and paid.
Laying only old retrieved stone putty/brick/PCC cover on the cable abutting each other for the cable protection gap between two adjacent patties n.exc 10mm complete all as specified and directed by Engr-in-Charge.
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for cable protection complete all as specified and directed by Engr-in-Charge.
Taking out existing old/rusted GI tubing of any size from pole/ trenches for necessary and Supply and lay light grade GI pipe with all fittings complete laid in trench/ fixed to Wall / Poles etc with suitable clamp for any type of pole, nuts, bolts washers etc required at site for protection of cable of the following sizes:-
25 mm dia
40 mm dia
50 mm dia
M&L PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole and stay complete all as specified and directed.
M&L PCC (1:3:6) type C-1 using 20mm graded aggregate as in coping of pole etc including form work complete all as specified and directed.
Material and labour for re-fixing of danger notice/safety board above HT/LT steel tubular/ PCC pole and to be maintained a suitable ht from ground level with proper alignment with Digital printed on retro reflective sheet (letter should be not less than 5CM in Red Colour) in HIndi and english both language all as specified and directed by Engr-in-Charge. Note :- Old two number of MS clamps suitable for steel tubular/PCC pole to be replaced by new one and including nut-bolts is inclusive in above quoted rate.
Supply and fix GI bracket of medium grade 40 mm bore GI tubing not less than 1.50 mtr long bend to required shape as in bracket for street light fittings fixed with two pair of MS flat iron clamp suitable for steel tubular/PCC pole as per site requirement with 4mm thick and including accessories i.e new nut-bolts and washers and other petty items required for fixing including painting with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed by Engr-in-Charge.
Supply and fix MCCB 4 Pole 100A Amps 415V 16KA and taking down existing unserviceable from its own position and taken as schedule of credit all as specified and directed by Engr-in-Charge.
Trimming and cutting of tree branches coming across LT over head line, clearing the line around 1.5m and disposal of shrubs to a distance up to 500mtr distance and cleaning the site complete all as directed. Note :- (i) Length of span shall be 45 to 50m. (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible. Note : All T&P shall be provoded by contractor
M & L for rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., Supplied & fixed External dia in 20 mm, complete all as specified and as directed by the Engineer-in-Charge
M & L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion,, complete all as specified and as directed by the Engineer-in-Charge
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire,, complete all as specified and as directed by the Engineer-in-Charge
Dismantling & taking down of old/rusted/broken PCC/steel pole from its existing position and Supply & fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) complete.
M&L for dismantling PCC for coping/base foundation of PCC/steel tubular pole all as directed.
S&F in reapir of cable lugs upto 25mm size properly fixing in junction box (incoming and outing boths cable ) properly tighting complete as per directed by EIC
S&F in reapir of DIN rail three phase with netural upto 40Amp properly fixing in junction box suitable for incoming and outing cables properly tighting complete as per specified and directed by EIC
M&L for locking system at junction box with suitable clamps for fixing the box as site requirment complete as per directed by EIC
M&L for Danger 440V with danger sign paste on junction box Digital printed on retro reflective sheet (letter should be not less than 2CM in Red Colour) properly paste on box with complete as per directed by EIC
Supply only Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified and directed by Engineer-in-Charge.
Sachiyay maa Electricals
vinayandsons
Tirupati electricals works and services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .