Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC C 234 ADG P CHENNAI | L1 | Accepted-AOC L1 bidder accepted after deducting schedule of credit amount and reduction offered on freakishly high items | |
| 2 | L2₹33.3 L+₹1.5 L (4.56%)Rejected-Finance THEKKEKOTTARAM RAMANTHALI PO KANNUR DIST KERALA 670 308 | RAMANTHALI | KANNUR | KERALA | 670308 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹34.1 L+₹2.2 L (6.95%)Rejected-Finance 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹36.0 L+₹4.1 L (13.0%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹37.3 L+₹5.4 L (17.1%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹47.9 L
EMD Value
₹95,800
Closing Date
8 Apr 2024, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2024_MES_646078_1
GE MAINT EZHIMALA 8629
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹95,800
Yes
24 Apr 2024
12 Mar 2024
10 Apr 2024
12 Mar 2024
8 Apr 2024
26 Mar 2024
13 Mar 2024 - 20 Mar 2024
Amount
Notes for all items of BOQ:- 1. Contractor should take necessary precautions such as laying plastic sheets on floors/covering windows etc to ensure that paint drops and splashes are not dropped on floors/furniture/joinery etc, in case paint splashes/drops are found contractor should clean all the paint marks otherwise a recovery of Rs.10/Sqm shall be made for the qrtrs/bldgs affected. 2. The Contractor should procure minimum 50% of the materials for all items as per BOQ (other than paints) mentioned in this CA within 20 days after getting sample approval and kept in safe custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of work. If contractor fail to complete the work within contract due to lack of fittings, a penalty of 20% shall be applicable on quoted rates by the contractor. 3. Contractor should complete all works related to welcome maintainence within 05 days from the date of handing over keys. 4. The contractor should visit the site before quoting the tender to know the working condition of the station. 5. All requisite safety measures are to be adopted by contractor on site. 6. The contractor shall provide and deploy sufficient electrician ( as approved by GE/ Engineer in charge) shall report at 9.00 hrs to JE E/M / Engineer in charge to collect the complaints job card in working days and complete the same complaint within 24 Hrs. 7. The complaints shall be rectified with in 24 hrs if the complaints is/ are not attended / not completed with in 24 hrs ( except repair/ replacement of major items) recovery will be done Rs. 500 per complaint per day. 8. For major parts like replacement of MCB, DBs, MCCBs etc should be rectified within 5 working days, if the contractor not rectify within time then recovery will be done at Rs. 1000 per complaint per day. 9. After completion of Job work complaint, the contractor has to produce job card duly signed by user& JE /Engineer in charge. 10. If contractor failed to provide their electrician or attend the complaints then recovery will be doneRs 1000 per day. 11. In repair works, rate quoted for demolition/dismantling/taking down is deemed to be inclusive of removing the same from site and dumped outside INA Ezhimala. 12. In maintenance works, the contractor should maintain separate registers for plumbing and carpenter repair works. Day to day complaints should be noted in those registers with Sl nos of complaints, location, qty of work, status of complaints and signature of in charge and stamp of the office. Format will be given from concern AGE office. The contractor should obtain the signature of in charge on the same day of work. These registers to be submitted to JE(Civil) on every weekend without fail. 13. The contracts involving working at elevated locations of buildings, contractor should ensure proper safety arrangements as per norms. Wearing safety belts and helmets are mandatory. A penalty of Rs 1000 per day will be recovered from contractor if safety norms are not followed. 14. The plumbing complaints resulting wastage of water should be rectified within 12 working hours and if contractor fail to fullfill this, a recovery of 10% of rate quoted for relevant item will be charged from contractor in this regard. 15. After completion of work, no stores/debris/loose items be kept at work site or dumped inside INA. Entire area to be cleared and waste material be taken outside INA.
M&L for preparation of old treated surfaces and applying one coat of white wash on wall complete all as specified and as directed.
M&L for preparation of old treated surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
M&L for preparation of old treated surfaces and applying one coat of colour wash on wall complete all as specified and as directed.
M&L for preparation of old treated surfaces and applying one coat of acrylic emulsion paint on wall (interior grade) complete all as specified and as per manufacturer's instructions.
M&L for preparation of old treated surfaces and applying two coats of acrylic emulsion paint on wall (interior grade) complete all as specified and as per manufacturer's instructions.
M&L for preparation of wall surfaces by scrubbing using nylon/jute/ wire brushes/ scrapper blades and applying wall care putty interior or exterior and finshing the surface even and smooth complete all as specified and as directed.
M&L for preparation of old painted surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces complete all as specified and as directed.
M&L for preparation of old decorated painted surfaces and applying one coat of synthetic enamel paint on old AC board ceiling complete all as specified and as directed.
M&L for preparation of old painted surfaces and applying one coat of epoxy paint to steel surfaces complete all as specified and as directed.
M&L for preparation of old painted surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint on steel/iron surfaces complete all as specified and as directed.
M&L for preparation of old painted surfaces and applying one coat of terracota paint on wall cladding complete all as specified and as directed.
M&L for preparation of old painted surfaces and applying one coat of sandtex matt finish to external wall/ chajja/ roof projection etc complete all as specified and as per manufacturer's instructions.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and as directed.
M&L for glazed ceramic coloured tiles 350x250x7mm /450x350x7 mm thick in vertical surfaces of stone/brick wall, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick backing coat plaster in CM 1:4 complete all as specified and as directed.
M&L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.06 sqm but n.exc 0.11 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles nt exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and fixed over screed bed 20 mm CM 1:4 complete all as specified and as directed.
All as per Sl item No.17 above but in skirtings complete all as specified and as directed.
M&L for machine cut granite stone slab 20mm thick of approved colour and shade as in floors, kitchen platform, steps and other similar situations over and including 15mm thick backing coat in CM 1:4 laid and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including grinding and polishing complete all as specified and as directed.
Rounding to edges of stone slabs to one edge, such as in kitchen platform, steps and other similar situations complete all as specified and as directed.
S&F in repairs matte finish stainless steel kitchen sink bowl type of any size complete all as specified and as directed.
Taking down chowkats or frames not exc. 1.5 Sqm each but without taking off shutters from the frames complete all as specified and as directed.
Taking down chowkats or frames exc. 1.5 Sqm but n.exc 4 Sqm each but without taking off shutters from the frames complete all as specified and as directed.
S&F powder coated aluminium frame for doors, windows, ventilators, partitions, kitchen cupboards, frames etc with one or more rebates including joining cleat for fixing etc. (minimum thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F powder coated aluminium door shutters, aluminium section weighing 0.55kg/ m incl necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified and as directed.
S&F powder coated aluminium window and ventilator shutters fixed or sliding type without sash bar, aluminium section weighing 0.55 kg/m incl necessary joining cleats, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and as directed.
Taking down shutter of any description exc. 1 Sqm and n. exc 2 Sqm each complete all as specified and as directed.
M&L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC, 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement, supplying & fixing in the frame at site as per site as per specification & drawing.
M&L for 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, both face is covered with decorative face veneer with lipping/frame to match supplied and fitted to chowkats complete all as specified and as directed
S&F 100mm stainless steel butt hinges, cold rolled medium weight complete all as specified and as directed.
S&F 200 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified and as directed.
S&F 125 mm mild steel butt hinges, cold rolled medium weight complete all as specified and as directed.
S&F 150 mm anodised aluminium handles cast type complete all as specified complete all as specified and as directed.
S&F 150 mm aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 300 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified and as directed.
S&F floor door stopper 150 mm size aluminium alloy body and tongue double legged, anodised fixed to door complete all as specified and as directed.
S&F in repairs 100 mm mild steel butt hinges, cold rolled medium weight complete all as specified and as directed.
S&F in repair mild steel friction hinges suitable for window/ ventilator shutters complete all as specified and as directed.
S&F in repairs 100 mm size butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed in repair type B11 complete all as specified and as directed.
S&F in repair 75 mm brass handles, cast type, polished, ornamental type for drawers, etc. complete all as specified and as directed.
S&F in repairs 150 mm brass handles, cast type, polished, ornamental type for cupboards complete all as specified and as directed.
S&F in repair aluminium powder coated Ebco handles for sliding windows complete fixed all as per manufacturer's instruction and as directed by Engr-in-Charge.
S&F in repair 75 mm hasp and staple mild steel safety type and fixed with screws complete all as specified and as directed.
S&F in repair aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum staples or beading complete all as specified and as directed.
S&F in repairs rubber beading suitable size for safety purpose (snake guard) in bottom of door complete all as specified and as directed.
S&F in repair block board, grade 2 quality, interior grade, decorative type, both faces, 18/19mm thick as in cupboard, drawer repair & fixed with screws to timber frame work complete all as specified and as directed.
S&F in repair both sides prelaminated medium density fibre board exterior grade 18/19 mm thick as in cupboard, drawer repair & fixed with screws to timber frame work complete all as specified and as directed.
S&F in repair 0.9mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and as directed.
S&F stainless steel telescopic drawer channel double ball bearing complete fixed all as per manufacturer's instructions and as directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed.
S&F sheet glass 4mm thick, ordinary quality and glazing with rubber beading/ oil putty area exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for 4mm thick sheet figured glass pin headed quality n exc 0.50 sqm in each pane and glazing with aluminium beading complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm but n exc 2 Sqm each and refixing the same after carrying out repair including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws etc. complete all as specified and as directed.
Repairs to wooden shutter of any description exc 1 Sqm but n exc 2 Sqm each including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws etc. complete all as specified and as directed.
Taking down existing aluminium glazed window shutters of any description for repairing and refixing in the same opening after carrying out repair works complete all as specified and as directed. Note:- New materials required for replacement of old items shall be measured and paid seperately vide relevant items of BOQ.
S&F in repair Mortice lock brass body, 100mm, 4 levers vertical type complete all as specified and as directed.
S&F in repair 20 mm bore curtain rods, anodised aluminium alloy, PVC coated with fixing brackets, stops, rollers etc complete all as specified and as directed.
S&F in repair aluminum (die cast) body door closer hydraulically regulated designation No. 2 universal type suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 Kg complete all as specified and as directed.
S&F in repair vitreous china, wash down water closet (EWC) white colour with PVC seat cover, closed pattern with flat bottom and cover with mild steel (CP) or aluminium hinging device fixed with necessary bolts complete all as specified and as directed.
S&F in repair plastic water closet seat cover white colour closed pattern with flat bottom and cover and MSCP or aluminised hinging device complete all as specified and as directed.
S&F in repair vitreous china wash basin, white coloured, flat back 550x400mm including waste coupling CP, fixing brackets, cutting for and pinning in ends of brackets complete all as specified and as directed.
S&F in repair PVC valveless syphonic action type flushing cistern low level with inlet ball valve, float and handle including brackets of 10 ltrs capacity complete all as specified and as directed.
S&F in repair 15mm bore chromium plated bib taps (fancy type), long body cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipes complete all as specified and as directed.
S&F in repair 15mm dia bore pillar taps, cast copper alloy, fancy type capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repair 15mm bore stop valves chromium plated cast copper alloy, fancy type screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes (concealed type) complete all as specified and as directed.
S&F in repair angular stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for union and fixed, suitable for 15 mm bore pipe complete all as specified and as directed.
S&F in repair cast copper alloy, chromium plated toilet paper holder complete all as specified and as directed.
S&F in repair chromium plated health faucets (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hanging the faucet etc complete all as specified and as directed.
S&F in repair PVC flexible waste pipe 32/40mm dia and length of 600mm (min) for urinals/WHB/sink etc complete all as specified and as directed.
S&F in repair cast copper alloy, chromium plated towel ring 15 cm dia complete all as specified and as directed.
S&F in repair cast copper alloy, brass chromium plated towel rail, 600mm long complete all as specified and as directed.
S&F in repair 125mm size brass chromium plated shower rose complete all as specified and as directed.
S&F in repair waste coupling, brass, chromium plated with long shank, half thread, 32mm dia, for WHB/urinal etc. complete all as specified and as directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F for flora centre hole basin mixture including CP extension nipple as required complete all as specified and as directed. Make :- Hindware model No. F280009CP or equivalent in Parryware/Cera/Jaquar.
S&F 15 mm bore sink cock swan neck (wall mount installation) type with chrome finish complete all as specified and as directed. Make :- Hindware model No. F280026CP or equivalent in Parryware/Cera/Jaquar.
S&F for bathroom plastic cabinet of size 0.45 x 0.55 x 0.12 mtr with mirror complete all as specified and as directed by Engr-in-charge. Make:- Nilkamal, Cello or equivalent as approved by GE.
S&F multi purpose glass corner shelf of size 300 x 300 mm, clear in color with stainless steel wall brackets and two grill bars, approved quality complete all as specified and as directed.
S&F wall mounted kitchen utensil dish rack, made of stainless steel, weight not less than 5 Kg, size 0.90m x 1.00m (Approx) of approved design and make complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing and connections 25-32mm bore in new or old position (wall, ceiling, floor etc.) complete all as specified and as directed.
S&F in repair 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including removal of existing pipe complete all as specified and as directed.
S&F in repair 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including removal of existing pipe complete all as specified and as directed.
Removal of air lock in internal water supply system of pipe of any dia complete all as specified and as directed.
Cleaning of water tank exc 250 & n.exc 500 lit, including cleaning all scales and dirts from inside of tank using bleaching powder and washed with water, complete all as specified including taking down and re-fixing of float valve, mentioning date of cleaning on water tank using white synthetic enamel paint as existing complete all as specified and as directed. Note:- After cleaning of water tank, the rep of contractor shall check during water supply time and ensure water is reaching to the qtr and float valve is working properly and no leakage at joints.
All as per item No.85 above but exc 500 & n. exc 1000 lit complete all as specified and as directed.
S&F in repairs PVC Lid/ cover for 500 lit to 1000 lit capacity water tank complete all as specified and as directed.
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 40 mm dia pipes complete all as specified and as directed.
Taking down serviceable bib tap, angle cock, stop cock, heath faucet etc and cleaning, servicing, putting washer etc and refixing on same pipe line complete all as specified and as directed.
Taking down, repairing & refixing of builders hardware items like handles, hinges, bolts, towerbolts, sliding bolt etc using necessary screws at the same position complete all as specified and as directed.
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed.
Taking down serviceable wire mesh & refixing the same using necessary beadings, nails etc. complete all as specified and as directed.
M&L in replacement of old unserviceable sub main wiring using 4 runs of 10 sq mm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 32mm dia medium grade surface on wall along with 1 runs of 10 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
M&L in replacement of old unserviceable sub main wiring using 4 runs of 6 sq mm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 25mm dia medium grade surface on wall along with 1 runs of 6 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
M&L in replacement of old unserviceable sub main wiring using 4 runs of 4 sq mm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 25mm dia medium grade surface on wall along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
All as per item No.95 above but in PVC casing and capping of suitable size complete all as specified and directed by Engr-in-charge. Note for item No.93 to 96 :- (i) One run of PVC conduit/casing and capping along with 5 runs of respective size of PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
M&L in replacement of old unserviceable sub main wiring using 2 runs of 4 sq mm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 20mm dia medium grade surface on wall along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
All as per item No.97 above but in PVC casing and capping of suitable size complete all as specified and directed by Engr-in-charge.
M&L in replacement of old unserviceable sub main wiring using 2 runs of 2.5 sq mm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 20mm dia medium grade surface on wall along with 1 run of 2.5sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
All as per item No.99 above but in PVC casing and capping of suitable size complete all as specified and directed by Engr-in-charge.
M&L in replacement of old unserviceable sub main wiring using 2 runs of 1.5 sq mm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 20mm dia medium grade surface on wall along with 1 run of 1.5 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
All as per item No.101 above but in PVC casing and capping of suitable size complete all as specified and directed by Engr-in-charge. Note for item No.97 to 102 :- (i) One run of PVC conduit/casing and capping along with 3 runs of respective size of PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
S&F in replacement of old unserviceable MCB protected socket PVC plastic base model with one single pole MCB, AC 240 Volts, 20 Amps including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable MCB triple pole & neutral AC 415 Volts, 50 Hz , C series 10 kA breaking capacity,40/ 63 Amps complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable MCB triple pole & neutral AC 415 Volts, 50 Hz , C series 10 kA breaking capacity, 25/32 Amps complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviseable MCB single pole 6 to 32 Amps capacity 230 Volts, C series 10 KA breaking capacity all as specified and directed by Engineer in charge.
S&F in replacement of old unserviseable MCB single pole and neutral 32 Amps capacity, C series, 10 KA, 50 Hz ,230 Volts C series 10 KA breaking capacity complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviseable RCBOs for earth leakage protection 4 pole 30m Amps,63 Amps,415 Volts complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviseable RCBOs for earth leakage protection 4 pole 30m Amps,40 Amps,415 Volts complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviseable RCBOs for earth leakage protection 4 pole 30m Amps,25/32 Amps,415 Volts complete all as specified and directed by Engineer in charge.
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, etc including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
M&L for color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC conduit of suitable size not less than 20mm dia medium grade, concealed /open as per site requirement with suitable size modular metal flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting switches or sockets regulators etc including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral and earth conductor. (iii) The wiring shall be done strictly by following proper colour coding using red , blue, yellow for phase, black for neutral and green for earth leads.
(a) One Light/ fan point controlled by one switch.
(b) One 3 pin socket outlet 5 Amps on the same board with other switches.
(c) 5 Amps socket point on independent board.
M&L for color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC casing and capping suitable size modular metal flush box/PVC box fitted with modular cover plate with frame (inner/ outer plate) for mounting switches,sockets,regulators etc including FRLS 1.5 sqmm earth wire copper insulated connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
(a) One Light/ fan point controlled by one switch.
(b) One 3 pin socket outlet 5 Amps on the same board with other switches.
(c) 5 Amps socket point on independent board
All as per item No.112 here in above but 2.5 sqmm for 6/16 Amps socket on independent board complete all as specified and directed by Engineer in charge.
All as per item No.113 here in above but 2.5 sqmm for 6/16 Amps socket on independent board complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable lamp holder, PVC/ Polycarbonate type with back plate suitable to batten fittings complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable calling bell, ding dong AC 230 Volts, single pole complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable ceiling rose 3 phase/ PVC/polycarbonate isolated body complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable modular switch one way 6 Amps 1 module complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable modular socket 6 Amps 2/3 pin 2 module complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable modular socket 6 Amps/16 Amps 3 pin 2 module multipurpose complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable modular switch one way 16 Amps 1 way 1 module complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable modular two way switch 6 Amps 1 module complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable modular bell push 6 Amps 1 module complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable modular fan step regulator, 2 module complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable 6 Amps 3 pin plug top complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable 16 Amps 3 pin plug top complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable switch socket combination 6A with PVC box complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable switch socket combination modular type 16A with PVC box complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable MCB DB TPN 415V double door type 4 way with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail suitable for fixing existing space and model vertical or horizonal, AC supply fixed to the existing wall after removing the unserviceable MCB DB and reconnecting the electrical connections making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable modular white cover plate with frame, 1 module complete all as specified and directed by Engineer in charge.
All as per item No.131 above but 2 module complete all as specified and directed by Engineer in charge.
All as per item No.131 above but 3 module complete all as specified and directed by Engineer in charge.
All as per item No.131 above but 4 module complete all as specified and directed by Engineer in charge.
All as per item No.131 above but 6 module complete all as specified and directed by Engineer in charge.
All as per item No.131 above but 8 module complete all as specified and directed by Engineer in charge.
All as per item No.131 above but 12/18 module complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable modular box suitable for fixing 1/2 module complete all as specified and directed by Engineer in charge. Note:- The rate quoted for replacing of modular box is deemed to be inclusive of necessary cement/putty work and finishing work of white wash /colour wash for matching with existing surface.
All as per item No.138 above but 3 module complete all as specified and directed by Engineer in charge.
All as per item No.138 above but 4 module complete all as specified and directed by Engineer in charge.
All as per item No.138 above but 6 module complete all as specified and directed by Engineer in charge.
All as per item No.138 above but 8/12 module complete all as specified and directed by Engineer in charge.
S&F in replacement of old unserviceable wall mounted 20 W LED 4ft white batten out put lumen ≥ 100 lumen/watts, efficacy 100 lumen per watt, CRI > 80, CCT >5500k , internal surge protection up to 4kV , power factor > 0.95 having extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver with all accessories pre-wired and including connecting up 3 core flexible copper conductor cable suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton model No. CCS-103-20-65-SL-DP-NWH or equivalent in Philips/ Wipro/Havells/Bajaj.
S&F in replacement of old unserviceable wall mounted 20 W LED 4ft warm batten out put, lumen ≥ 100 lumen/watts, efficacy 100 lumen per watt,CRI > 80, CCT >3000k , internal surge protection up to 4Kv , power factor > 0.95, THD ≤10% having extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver with all accessories pre-wired and including connecting up 3 core flexible copper conductor cable suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton model No. CCS-103-20-65-SL-DP-WW or equivalent in Philips/ Wipro/Havells/Bajaj.
S&F in replacement old unserviceable wall mounted 10 W 2 ft LED batten, out put lumen ≥ 100 lumen/watts, efficacy 100 lumen per watt, life 50,000 burning hrs, aluminum body, surge protection 4kV, power factor > 0.98, THD ≤10%, extruded channel in thermally conductive material for efficient heat dissipation with Polycarbonate diffuser and integrated electronic driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton model No. CCS-103-10-65-SL-DP-NWH or equivalent in Philips/ Wipro/Havells/Bajaj.
S&F in replacement high efficacy LED 18 watt surface full lit luminaire with glare free uniform illumination with longer life and less maintenance and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals out put lumen lumen/watts, efficacy lumen per watt, life 50,000 burning hrs, aluminum body, surge protection 4kV, power factor > 0.98, THD ≤ 10%, making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton model No. LCDSPLN-S-18-CDL or equivalent in Philips/ Wipro/ Havells/Bajaj.
S&F in replacement of 18 W round surface mounted LED panel, pressurised die cast aluminium body housing and high translucent frosted plastic diffuser with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals out put lumen >110 lumen/watts, efficacy 100lumen per watt, life 50,000 burning hrs, aluminum body, surge protection 4kV, power factor > 0.98, THD ≤10% making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton model No. LCDSPLN-R-18-CDL or equivalent in Philips/Wipro/ Havells/Bajaj.
S&F in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head edge-lit LED luminaire out put lumen >100 lumen/watts, efficacy 100 lumen per watt, life 50,000 burning hrs, aluminum body, surge protection 4kV, power factor > 0.98, THD ≤10%, making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Jaquar model No. LBLK02X010XN or equivalent in Crompton/Bajaj/Havells.
S&F in replacement decorative wall light (Globe Type ) fixture made up of poly carbonate suitable up to 1 x 10 W LED Bulb (B-22 base ) making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Havells Model No. LHFOFUE1T21W012 or equivalent in Philips/Crompton/ Bajaj/Wipro.
S&F in repair capacitors 4 mfd, AC 440 Volts suitable for exhaust fan complete all as specified and directed by Engineer-in charge.
S&F in repair capacitors 2.5mfd, AC 440 Volts suitable for celling fan/exhaust fan complete all as specified and directed by Engineer-in charge.
S&F in repair 9 W LED lamp, BEE rated white/warm white with base B22 complete all as specified and directed by Engineer-in charge. Make:- Crompton/Philips/Crompton/ Bajaj/Wipro.
S&F in repair 9 W LED lamp warm white with base E27 complete all as specified and directed by Engineer-in charge. Make:- Crompton/Philips/Crompton/ Bajaj/Wipro.
S&F in replacement of old unserviceable three phase electronic meters temper proof LCD display with polycarbonate cover 415 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including taking down of old meter and deposit at MES complete all as specified and directed by Engineer-in charge. Note:- Contractor has to deposit old energy meters to MES for safe custody and it will be MES property and contractor has to submit the old meter Sl no, final reading of old meter, New meter Sl No, initial reading of the new meter for proper accounting of revenue.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm thick buried directly in ground, earth pit not less than 2.25 meter deep below ground level, connected to 25x4 mm size galvanized iron strip as earthing strip by means of bolts, nuts check nuts and washer of galvanized iron or steel all as shown in electric plate No 3 of SSR part I connected to earthing test point all as specified or indicated including provn of necessary excavation and earthwork in any type of soil , PCC pit RCC cover and 20 mm bore medium grade, watering pipe, water funnel with GI wire mesh, 40mm bore medium grade protection pipe, common salt, charcoal dust, returning filling in soil, removal of spoil to a distance not exceeding 50 mtr etc, including testing on completion complete all as specified and directed by Engineer-in charge.
M&L for earth continuity conductor or main earthing lead fixed to wall on epoxy /OMC insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x4 mm galvanised iron strip complete all as specified and directed by Engineer-in charge.
All as per item No.156 above but copper strip 20x3 mm size complete all as specified and directed by Engineer-in charge.
S&F in repair rigid non-metallic 25mm PVC casing capping exclusive of wall rawl plugs/Gitti and screw, including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
Palace constructions
ROTECH ENGINEERS AND BUILDERS
NRI BUILDERS AND MATERIAL SUPPLIERS
SREEKRUPA ENTERPRISES
Gates Infra Construction Co
Benchmark Engineers and Contractors
KDR CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .