Tender Value
₹25 L
EMD Value
₹75,000
Closing Date
27 Mar 2024, 11:00 amClosed
Executive Director
Executive Director, AIIMS Bibinagar
Repair and maintenance of Split oblique Cassette Type Air Conditioners at AAIMS Bibinagar, Telangana
2024_AIIBB_799623_1
AIIMS/BBN/SE/08/2023-24
Open Tender
Air-Conditioner
Works
15 days
AIIMS Bibinagar Nalgonda
As per Tender Documents
2 documents required · 2 mandatory
₹500
All india Institute of Medical Sciences Bibinagar
₹75,000
Yes
SE Office, AIIMS Bibinagar
22 Apr 2024
9 Mar 2024
28 Mar 2024
9 Mar 2024
27 Mar 2024
9 Mar 2024
9 Mar 2024 - 27 Mar 2024
18 Mar 2024
Amount
General servicing of 1/1.5/2 ton Split Air conditioners includes as follows
i) Inspection of the AC – IDU and ODU for any abnormality in operation, sound, cooling etc ii) Testing the Performance of AC for desired cooling. iii) Remove dust and clean the inside and outside units. iv) Testing of Gas pressure if necessary and check for any leakages near the check nut etc or diagnose any other fault. v) Remove the filter, water service and fix it back after drying. If any damage Replace with new filters (Filter amount Paid sepparetly) vi) Clean the drain tray and drain pipe and remove any choke for free flow of drain water. vii) Clean the Evaporator with brush and remove the dirt/dust. Check for any fungus formation or bad smell and wash it with chemical, if required. viii) Water washing of Condenser Coil. ix) Topping of Refrigerant gas, if required (Refrigerent amount to be paid for separately) x) Clean the condenser coil with blower. xi) Clean the external grill/casing with soap water jet wash. xii) Check for any loose connections. xiii) Lubricate the motors, whenever necessary and carry out maintenance of compressor/fan motor. xiv) Wet cleaning/de-scaling must be carried. xv) Carry out Repairs/Maintenance of any other items/parts of the unit including unit bracket and casing. (Major Spare parts repaire or to be paid for separately) xvi) Seal a small openings around the pipingswith gum type sealer.
Split AC Indoor Unit
PCB Replacement (Non inverter) only single side indoor or out door compitable to existing unit.
PCB Replacement (Non inverter) only Both side indoor and out door
PCB Replacement (inverter) only single side indoor or out door compitable to existing unit
PCB Replacement (inverter) Both side indoor and out door
PCB Repair (Non inverter/Inverter)
Sensor Replacement
Stabilizers for 1/1.5 ton
Stabilizers for 2 ton
Blower Motors Replacement
Swing motors replacement for 1.5/2 Ton Split
Blower
Air filters
Remote control Units Original
Louver set
Split AC Out door Unit
Out door Fan Motor Replacement
Out door Fan Replacement
Fan Capacitor Replacement
Compressor Replacement
Compressor Capacitor
Condenser Coils replacement and gas fiiling in condenser coil
Gas Filling including Refrigerant
For All type of Split and cassette Air conditioners
Relocation (including indoors and out door unit)
Supply and laying with foarm insulation of 12mm Copper pipe including tubular foam Insulation
Supply and laying with foarm insulation of Supply 15mm Copper pipe including tubular foam Insulation
Laying cost of copper pipe up to 15 mm (if material Provided by AIIMS)
Outdoor stand set
Core cutting (including Wall/Concrete)
Foam Insulation
For Cassette Air conditioner
General servicing 2/3 ton Cassette AC: General servicing of 2/3ton cassette Air conditioners includes as follows i) Inspection of the AC – IDU and ODU for any abnormality in operation, sound etc ii) Testing the Performance of AC for desired cooling. iii) Remove dust and clean the inside and outside units. iv) Testing of Gas pressure if necessary and check for any leakages near the check nut etc or diagnose any other fault. v) Remove the filter, water service and fix it back after drying. If any damage Replace with new filters (Filter amount Paid sepparetly) vi) Clean the drain tray and drain pipe and remove any choke for free flow of drain water. vii) Clean the Evaporator with brush and remove the dirt/dust. Check for any fungus formation or bad smell and wash it with chemical, if required. viii) Water washing of Condenser Coil. ix) Topping of Refrigerant gas, if required (Refrigerent amount to be paid for separately) x) Clean the condenser coil with blower. xi) Clean the external grill/casing with soap water jet wash. xii) Check for any loose connections. xiii) Lubricate the motors, whenever necessary and carry out maintenance of compressor/fan motor. xiv) Wet cleaning/de-scaling must be carried. xv) Carry out Repairs/Maintenance of any other items/parts of the unit including unit bracket and casing. (Major Spare parts repaire or to be paid for separately) xvi) Seal a small opening around the pipings with gum type sealer.
For Cassette Air conditioner Indoor Unit
Blower indoor
Blower Motors Replacement
Drain Water pump
PCB replacement including sensors one side indoor or out door unit for Cassete AC 2/3Ton
PCB replacement including sensors Two sides indoor and out door unit for Cassete AC 2/3 Ton
PCB Repair indoor and out door unit for Cassette AC 3/4 Ton
Main supply terminals
Capacitor replacement
Running Capacitors
Nitrogen Leakage Testing and Rectification
Contactors heavy 3 phase
For Cassette Air conditioner Out door Unit
Out door Fan Motor Replacement
Out door Fan Replacement
Fan Capacitor Replacement
Compressor Replacement
Compressor Capacitor
Gas Filling including Refrigerant in 2Ton
Gas Filling including Refrigerant in 3Ton
Filters
Remote control Units Original
Condenser Coils replacement and gas fiiling in condenser coil
Cabling from IDU to ODU
Minor Parts of indoor / Outdoor unit enclosures fastners
Drain piping from IDU to drain point
spr constructions
VIJAYA REFRIGERATION N ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .