Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹32.4 L+₹4.4 L (15.8%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹63,200
Closing Date
30 Nov 2022, 6:00 pmClosed
CWE Ambala
Headquarter Commander Works Engineer Ambala Mansfield Road Ambala Cantt
PROVISION OF 630 KVA TRANSFORMER ALONGWITH CONNECTED ITEMS FOR HARDING LINE (TANKI WALA SUB STN) UNDER GE (UTILITY) AMBALA CANTT
2022_MES_556391_1
CWE/AMB/UTILITY-31 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ambala Cantt
All as per tender documents
9 documents required · 9 mandatory
₹500
GE UTILITY AMBALA CANTT
₹63,200
Yes
17 Jan 2023
27 Oct 2022
2 Dec 2022
27 Oct 2022
30 Nov 2022
18 Nov 2022
27 Oct 2022 - 16 Nov 2022
Amount
Supply, installation, testing and commissioning of step down transformer out door type complete with standard fittings and accessories, HT 11 KV 3 Phase, LT 433 Volt, 3 Phase 4 wire with off load tap changer on primary side to carry secondary voltage tapping range + 7.5% with tappings at every steps 2.5 % all as per IS 1180 Part-I (2014 , With Latest Amendment No 1, 2, 3 & 4 of Energy Efficiency Level -2) Level-2, for Transformer manufacturing of capacity 630 KVA, copper wound, oil cooling with fins vector group : DYn 11, including initial oil filling (oil confirming to IS 335 and ISI Mark) complete all as specified including the following accessories :- (a) Three Nos porcelain bushing HT 11 KV with brass bushing rods, nuts, bolts & washers etc inside cable end box. (b) One cable box LV side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT UG cable with cable glands. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover. (g) One No 100mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centigrade.(h) Bachholz relay
(i) Rating plate and terminal marking plate (j) Earthing arrangement.(k) Oil level gauge. (l) Oil drain filter valve. (m) Oil drain valve. (n) Lifting hook. (o) Oil conservator with filling hole and cap. (p) Air relief valve plug. (q) Four plate solid cast steel detachable rollers. (r) Earth bushing for neutral outside the cable box for providing independent earthing for neutral. (s) Necessary channel on foundation for fixing the transformer with joint and stopper. Note :- The transformer should be energy efficiency level-2 and energy conservation (Energy conservation Binary Corps) for which necessary test certificate to be produced by contractor from manufacturer of the trasformer.
Supply and fixing LT feeder pillar panel size 2.0 mtr x 1.8 mtr x 75 cm weather proof, degree of protection IP-56, out door type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and rear open able double door system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable / open able by keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 and LT panel shall be tested from CPRI type test for 4000 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS-61439/2011 and Part I and Part 2 type test certificate comprising of the following : (a) copper busbar of capacity 2000 Amps – Set of four (b) Incoming ACB, 1250 Amps , 4 pole with microprocessor release, MDO 4 pole , 415 V, 50 KA-01 No
Supply and fixing LT feeder pillar panel size 105CmX70Cm x50Cm weather proof , degree of protection IP-56, out door type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and rear openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 and LT panel shall be tested from CPRI type test for 4000 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :- (a) MCCB 125 Amps TPN 25 kA- 01 No (b) Copper busbar of capacity 200 Amps with colour coated heat shrinkable sleeves and suitable hole for outgoing connection- Set of four (c) Misc items like screws, cable tie, complete wiring with copper cable 1.5/2.5 Sqmm, cable lugs, sleeves etc complete.
Notes: (i) The quoted rates shall be inclusive of minor items such as lugs, nuts, bolts, washers, top insulators, sleeves and provision of extra holes in bus bar as directed. (ii) All internal wiring shall be done with suitable size FRLS cable confirimng to IS 694 of approved make. (iii) The drawing of panel shall be approved by Accepting officer before placing order. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Test certificate of panel board shall be submitted by contractor. (iv) The cable in panel shall be entered through gland.
Supplying and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 95 Sqmm 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part - 2 for insulation and for conductors Class 2 to IS 8130 - 84, in trenches, floors, ducts passing through pipe for road crossing etc., complete all as specified and directed. Note : Excavation, earth work, cable cover protection, sand cushioning and GI pipe etc shall be measured & paid for separately.
Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 400 Sqmm single core grade, laid in trenches, floors, ducts passing through pipe for road crossing or in any other situation complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured & paid for separately).
Supplying and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 300 Sqmm 3.5 core, suitable for 11 KV earthed system confirming to IS 7098 Part - 2 for insulation and for conductors Class 2 to IS 8130 - 84, in trenches, floors, ducts passing through pipe for road crossing etc., complete all as specified and directed. Note : Excavation, earth work, cable cover protection, sand cushioning and GI pipe etc shall be measured & paid for separately.
Supplying and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 70 Sqmm 3.5 core, suitable for 11 KV earthed system confirming to IS 7098 Part - 2 for insulation and for conductors Class 2 to IS 8130 - 84, in trenches, floors, ducts passing through pipe for road crossing etc., complete all as specified and directed. Note : Excavation, earth work, cable cover protection, sand cushioning and GI pipe etc shall be measured & paid for separately.
Material and labour for boring of holes under road, pavement, hard standing of any material and description, by trench less technology using ultra sound technique of boring by manual providing HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete, all as specified and as directed. Note:- Any damage of other property like sewage pipes, other cables , water pipes etc will be repaired/replaced under this item without extra cost. Department will not responsible of any damage.
Supply and fixing of GI tubing, 100mm bore, light grade, on poles/on walls/under floors/ road crossing as required at site complete all as specified and directed. Note : Clamps. Nuts bolts, saddle etc will be measured and paid seperately.
Supply and fixing of GI tubing, 80mm bore, light grade, on poles/on walls/under floors/ road crossing as required at site complete all as specified and directed. Note : Clamps. Nuts bolts, saddle etc will be measured and paid seperately.
Material and labour for cable end termination jointing kit, HT 11 KV, earthed system (cold shrinkable), outdoor type joint complete with jointing material and accessories suitable for HT XLPE cable of size 50-95 sqmm, 3 core, 11 KV grade, earthed system complete all as specified and as directed.
Material and labour for cable end termination jointing kit, HT 11 KV, earthed system (heat shrinkable), outdoor type joint complete with jointing material and accessories suitable for HT XLPE cable of size 70-300 sqmm, 3.5 core, 1100V grade, earthed system complete all as specified and as directed.
Supply, Installationg, testing and commissioning of air breaker gang operated device triple pole switch ( GODO) outdoor type, vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with 02 Nos clamp hook for protection of operating GI pipe including locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element having upto 200 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection complete all as specified and directed .
Supply and fixing of lightning arrestor, expulsion type, suitable for 11000 volts, with all fittings, trasmission class, discharge capacity 65 KA, including connecting with HT line complete all as specified and as directed.
Material and labour for disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
Material and labour for pin type porcelain vitreous white or brown or green insulator 11000 volt grade of 150mm dia, 150mm height including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts including dismantling and taking down old insulator complete all as specified and directed.
Material and labour for earthing complete with galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 32x6 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore (medium grade) and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe (medium grade) for watering and 40mm bore GI protection pipe, funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion, if the desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Material and labour for earthing complete with galvanised earth plate electrode 600mm x 600mmx 6mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 4.00 mm GI wire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized iron pipe 15mm dia (medium grade) and connected to main switch or main control board all as shown in Electrical Plate No.3 of SSR Part-I & including necessary excavation and earth work in any type of strata, PCC (1:3:6) type C1 in pit, RCC cover slab 50mm thick in 1:2:4 type B-1 using 8mm dia TMT bars @10cm c/c both way with one 8mm dia bar as handle for lifting, 20mm dia GI pipe medium grade watering pipe, funnel, wire wesh, charcoal or coke & salt in alternate layers, etc.all as indicated including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion, if the desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays, locating fault of LT Cable and stay assembly and in other situation not exceeding 10 Square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed. Note:- Punned thickness 18cm shall be measured for payment purposes.
Supply and laying of un-reinforced precast concrete cable cover ,class HV, type-1 with peak, size 300X180X40mm complete all as specified and directed.
Supply and laying sub class ‘B’ bricks old sizes over the HT/LT cable laid flat with width equal to length of brick laid perpendicular to the cable for protection, complete all as specified and as directed.
Material and labour for cross arms,bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape of size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Material and labour for hardcore of broken stone or boulders filling of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Excavating in post holes or similar holes, each not.exceeding 0.5 cu mtr, getting out, in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate), as in post holes, complete, all as specified and as directed.
Supply and fixing of rolled mild steel angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 etc. complete all as specified and directed.
Material and labour for mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of shank 5 to 10mm and length of bolt exceeding 5cm and not exceeding 10cm complete all as specified and directed.
Supply only 4mm dia galvanised mild steel wire chain link fencing of mesh size 50 to 100mm, complete all as specified and directed. Note:- Weight of chain link fencing shall be ascertained through BOO and same shall be convened by GE during execution of work.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. with and including MS binding wire complete all as specified and directed.
Material and labour for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips 10mm dia round bars confirming to Fe 500/550 D as in stiffeners to chain link fencing complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of approved colour synthetic enamel paint, over a coat of red oxide primer complete all as specified and as directed.
Material and labour for preparation of new steel surfaces, of any description not otherwise described, over 10 cm width or girth and applying two coats of approved colour synthetic enamel paint, over a coat of red oxide zinc crome primer complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete, all as specified and as directed.
Material and labour for PCC 1:3:6 type C-1 (using 20 mm graded mechanically crushed stone aggregates) as in fixing of hold fast, coping of pole and strut, bed plates and the like, finishing the surface fair and even, including necessary form work, complete, all as specified and as directed.
Material and labour for brick work, using sub class ‘B’ bricks, straight or curved on plan to any radius, exceeding 6mtr mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregates) as in coping and the like, finishing the surface fair and even, including necessary form work, complete, all as specified and as directed.
Material and labour for hand packing (any thickness) with broken stone or boulders at back of walls over arches etc. and raising (or lowering) to the required level including necassary ramming and watering complete all as specified and directed.
Material and labour for 100 mm thick PCC (1:2:4) type B-2, using 40 mm graded mechanically crushed stone aggregates, as in floor, finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 15 mm thick on surfaces of brick work or concrete surfaces, in cement mortar 1:4, finished even and smooth without extra cement complete all as specified and as directed.
Material and labour for preperation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
Material and labour for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Raman Electric Trading Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .