| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.0 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹12.6 L+₹24,399.90 (1.98%)Rejected-AOC BMC 1 54 GANTI NETAJI PALLY PO GANGANAGAR KOLKATA 700 132 INDIA | 24 PARAGANAS NORTH | WEST BENGAL | 700132 | 2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | 3₹13.8 L+₹1.4 L (11.6%)Rejected-AOC | 3 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 4 | 4₹14.9 L+₹2.5 L (20.6%)Rejected-AOC | 4 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
10 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
GE I P Fy ISHAPORE, PO NAWABGANJ, DIST 24 PGS N WB-743144
As per tender documents
2020_MES_384753_2
8650/2020-21/E8
Open Tender
Civil Works
Item Rate
180 days
GE I P FY ISHAPORE
Class E Category a(I) and b(I)
6 documents required · 6 mandatory
₹500
Yes
GE I P FY ISHAPORE
₹28,000
Yes
1 Dec 2020
20 Oct 2020
11 Nov 2020
20 Oct 2020
10 Nov 2020
21 Oct 2020
20 Oct 2020 - 29 Oct 2020
60 days
Amount
Schedule 'A' Part-I (B/R items)
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundations, for laying of pipes/cables/poles etc, or for shafts, well, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.50m in deep and getting out in soft and loose soil complete all as specified and directed.
M & L for PCC (1:4:8), type D-2 using 40mm graded stone aggregrate as in foundation of filling and mass concrete etc, complete all as specified and directed.
M&L for formwork to sides for flats rough finished surfaceof concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions square or rectangulars or polygonal rough finished surfaces of concrete complete all as specified.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges etc.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves for flat rough finished surface of concrete.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified.
M&L for reinforced cement concrete Design mix (M-25) (20mm graded stone aggregates) as in Beams/Bend, cantilevers, bressummers, lintels over 1.5m span. Note: Reinforcement and formwork shall be measured and paid for separately.
M&L for reinforced cement concrete Design mix (M-25) (20mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. Note: Reinforcement and formwork shall be measured and paid for separately.
M&L for reinforced cement concrete Design mix (M-25) (20mm graded stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified. Note: Reinforcement and formwork shall be measured and paid for separately.
M&L for reinforced cement concrete Design Mix (M-25) (20mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, deck slabs and in shelves and the like complete all as specified. Note: Reinforcement and formwork shall be measured and paid for separately.
-ditto- all as per item No 1.11 above but as chajjas
M&L for 10 mm dia and over mild steel TMT bars as in reinforcement, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified.
---ditto all as per item No 1.13 above but 5 mm dia and over up to and incl 10 mm dia as in stirrups
M&L for brick work with flyash old size bricks, straight or curved on plan to any radius in half brick thick walls built in 1:4 cement mortar complete all as specified.
M&L for 10 mm thick cement plastering in cement mortar 1:4 and 5mm thick top layer shold be treated with WPC on other than fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid seperately as Supply only
Supply only integral waterproofing compound
M&L for 1.5mm thickk putty on ceiling surfaces complete all as specified.
M&L rendering 10mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surface finished even and smooth without using extra cement complete all as specified
Preparing new plastered surfaces of ceiling surfaces and applying three coats of white wash complete all as specified and as directed
Preparing new plastered surfaces of wall/concrete surfaces and applying three coats of white wash complete all as specified and as directed
M&L for preparing new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:4:8, type D-2 ( using 40 mm graded stone aggregate) as in sub base complete all as specified.
M&L for 25mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in floor complete all as specified.
M&L for non skid colour ceramic tile 7 to 8 mm thick (square/ rectingular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match including screed bed or bedding layer of mortar 10 mm thick for laying floor finishes with C M 1:6 complete all as specified.
M&L for glazed ceramic colour walls tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering backing coat on vertical surface of wall in 10 mm thick CM 1:6 to receive wall tiles complete all asa specified.
M&L Hardcore of Broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M&L for 50mm thick cement concrete 1:3:6, type C-2 ( using 40 mm graded stone aggregate) as in plinth protection, laid in alternate bays , finished concrete surfaces even and smooth without using extra cement, complete all as specified.
M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick as in soils complete all as specified and as directed.
M&L for removing excavated material/soil to a distance exceeding 250m and not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing. The door frame shall be tied to the wall using 75/100mm long MS screw as directed .
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tube for top & bottom rails. M.S. frame shall be covered with heat mounlded plain cplour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solveent cement for stiles and plain colour PVC sheets for top rail; lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointing together with solvent cement, supplying and fixing in the frame at site as per specification & drawing.
M&L for 100 mm butt hinges stainless steel medium weight approved make ISI marked complete all as specified.
S&F 125 mm aluminium alloy handles, cast type anodised all as specified.
S&F aluminium anodised barrel tower bolts of extruded section, 200mm long.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, 300mm long completed all as specified.
Supply & fix for steel window/ventilators top hung single shutter (half galzed half fixed) including hinges, handles, peg stays, etc complete complete all as specified.
M&L for 4mm thick float glass, ordinary quality, in squares n exc 0.5 sqm each pane complete all as specified.
M&L for preparation of new mild steel surfaces of any description, over 10cm in width or girth, not otherwise described two coats of synthetic enamel painting over a coat of primer complete all as specified.
Supply and fix PVC (SWR) pipes 110mm dia type 'A', single socketed, conforming to IS-13592:1992 in any length with rubber ring joints laid on wall/floor complete all as specified.
Supply and fix for 110mm dia PVC (SWR) bends any radius complete all as specified.
Supply & fix for 15mm bore GI tubing, medium grade, with all fittings fixed on wall and ceiling or laid on floor complete all as specified.
Supply and fixfor Vitreous China squatting pan of ‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern complete including provision of PCC bedding and connection to trap, and to flushing pipe, antisyphonage pipe, etc. complete including making good to floor all as specified and directed.
Supply and fixing for vitreous China white wash down water closet pan (pedestal pattern) 530 x 380 x 400mm size with ‘P’ or ‘S’ trap complete, front or back inlet, fixing bolts, PVC seat cover including 32 mm dia PVC flush pipe and making all necessary connections complete as specified.
Supply and fix WC seat cover white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminimum hinging device complete all as specified.
S&F 10 litre capacity PVC low level flushing cistern with and including flush pipe and all accessories complete.
Supply and fix for vitreous china, half stall urinal, size 250 x 330 x 460mm white including spreader with union and grating for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, securing urinal to plugs with and incl, 60 mm long brass screws, pointing around urinal back in cement mortar 1:2 all as specified.
S&F Vitreous china wash hand basins, size 570 x 425 x 220mm flat back or angle back type) including 32mm dia brass chromium plated waste fitting, a pair of CI brackets duly painted/erecting stand including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3, complete all as specified.
M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing use as partion complete all as specified
M&L for Vitreous chaina urinal partition white of size 130 x 330 x 675mm complete all as specified. Make: Parryware Cat No C0507 or equivalent as in the list of makes.
Supply and fix 15mm bore Brass CP pillar tap screwed down for iron pipe and fixed. Make:-ESSCO Cat No SQT507KN or equivalent.
Supply and fix 15 mm bore stop valve brass chromium plated for iron pipe or for unions. Make : Essco Cat No SQT 513AKN/513BKN or equivalent.
Supply and fix bib taps 15mm bore brass chromium plated screwed down, screwed for iron pipe or for brass ferrule. Make:-ESSCO Cat No SQT 511 KN or equivalent.
S&F Grating round 150mm size of PTMT.(Minimun weight 100gms)
Material and labour for hoisting and fixing rotational moulded polyethylene(double layer cylindrical vertical) LLDPE water storage tanks 500 lit capacity ISI marked(IS-12701:1996) hoisted and fixed in position including inlet, oulet and over flow connection etc complete all as specified.
Supply and fixing for gun metal globe or gate valve class-1 (pressure rating) conforming to IS-778 with iron wheel head screwed both ends for GI tubing 15mm bore complete all as specified.
S& F 15mm ball valves high pressure of PTMT with epoxy coated almunium rod & high density ball screwed for iron pipe and fixed
S&F PTMT connection 15 mm dia x 450mm long with connecting washer and bolts complete all as spfd and directed
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified.
Material & labour for precast PCC chequered tiles 300 x 300 x 20mm thick set jointed and pointed in neat cement slurry to match and laid over screed bed 20mm thick in CM 1:6 all as specified.
Removing surplus soil to a distance exc 500m but not exceeding 1.50Km and dpositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
M & L for brickwork with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregrate as in benching to surface channels for manholes or drains etc. including finishing top of benching even and smooth using extra cement and including necessary formwork, complete all as specified and a directed.
M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregrate as in coping, etc, including necessary formwork, weathering, slightly rounded or chamfered and throating with necessary form works complete all as specified and a directed.
Material and labour for RCC M-20 (nominal mix, using 20mm graded stone aggregate) as in pre-cast slab including necessary form work set in cement mortar 1:4 all as all as specified. Note: Reinforcement shall be measured and paid for separately.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregrate in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore complete all as specified and directed.
Material & labour for 150mm internal dia of salt glazed stoneware drain pipes grade 'A' laid on PCC bed and jointed complete all as specified.
M&L for cutting into existing manholes for connecting new drains 150mm dia, making goodto pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
Material & labour for GI pipe 25mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors.
Supply and fixing for gun metal globe or gate valve class-1 (pressure rating) conforming to IS-778 with iron wheel head screwed both ends for GI tubing complete all as specified for 25mm bore of tubing.
Schedule 'A' Part-II (Internal Electrification)
Material and labour for point wiring for with One light/fan point controlled by one switch 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade drawing in and including PVC (medium grade) casing capping along with 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly and to be terminated in and including pressed steel sunken boxs 1.25mm for boxes of suitable size with 3mm bakelite sheet cover for mounting switches switches, socket and fan regulator including testing on completion all as specified.
Supply and fixing switch piano flush button single pole one way 6 Amp all as specified.
S & F for ceiling rose surface bakelite 3 terminals complete all as specified.
Supply and fixing tube light fittings LED T8 tube light fitting 1 x 16watt with accessories internally prewired and connecting with twin twisted flexible copper cable 0.75 Sqmm from ceiling rose to light fittings complete with fixing accessories all as specified. Make Crompton Cat No IGP-161LT8-16 and lamp model LTT8-16 or equivalent as in the list of Makes.
Supply and fix exhaust fan 300mm sweep PVC body with louvers single phase 230 volts including cutting of hole, fixing nuts and bolts and making good the disturbed surfaces complete all as directed. Make:- Havells model VentAir-DS or equivalent as in the list of Makes.
M&L for sub main wiring with two single core PVC insulated, PVC sheathed stranded copper conductor (FRLS) cable of size 2 x 4 sq mm unsheathed drawn in and including PVC caping casing (medium duty) including accessories in surface to wall/floor/ceiling etc and 1 x 2.5 sq mm PVC insulated unsheathed copper conductor as continous earth continuity conductor complete all as specified.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, powder coated, SPN 240 Volt, double door, suitable for 2 way with dim rail earth and neutral bar all as specified.
Supplying, laying and testing XLPE insulated PVC sheathed, galvanised steel strip or wire armoured LT 1100 volt grade aluminium conductor cable of size 4 Sqmm 2core all as specified. Note :- Excavation and earth work shall be measured and paid for separately under relevant item of Sch A.
Supply and fixing MCB SPN 240 volts 6 to 32 Amps, 10 kA, 'B' curve all as specified.
Schedule 'A' Part-III (E/M maintenange work OFIL)
S&F 60 W LED street light luminairies including lamp with pressure die cast aluminium housing, heat resistant touhened glass, IP 66 protection and better optics for uniform distribution including suitable size of cable of not more than 1.50 m in length and other accessories fixed on pole / wall including mounting 40 mm dia light grade GI pipe bracket arm (not less than 1.50 m length) , clamps of suitable size, nuts, bolts, washers including taking down old unserviceable fittings complete all as specified and directed. Make: Crompton, Cat Part No- LSTP-60-CDL-M or equivalent as in the list of makes.
Taking down old unserviceable cable of any size and removal off the site.
Supply and laying including termination and connection of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 4.0 core, 1100 volts grade, cross-sectional area 10 sq. mm including necessary excavation of earth work wherever required complete all as specified and as directed by Engr-in-Charge.
Supply and laying XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 3.5 core, 1100 volts grade, cross-sectional area 120 sq. mm
Supply and laying XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 3.5 core, 1100 volts grade, cross-sectional area 25 sq. mm
M&L Sub main wiring with 6 Sqmm (Nominal area) with two runs of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC casing-caping fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to earth point complete as specified and directed.
S & F sheet metal enclosure distribution board single pole and neutral 240 volts 8 way double door type with required rated bas bar for fixing MCB including taking down old UNSV DB complete all as specified and directed.
S & F Triple pole and neutral 4 way double door MCB DB including taking down old UNSV DB all as specified and directed by Engr-in-Charge
S & F 4P MCCB enclosure with 63 Amps MCCB including taking down old UNSV DB all as specified and directed by Engr-in-Charge.
S & F MCB SPN 6-32 Amps 240 volts 10 KA, 'C' curve rating complete all as specified and directed.
S & F MCB SP 6-32 Amps 240 volts 10 KA, 'C' curve rating complete all as specified and directed.
S & F MCB TPN 63 Amps 415 volts 10 KA, 'C' curve rating complete all as specified and directed.
S & F MCB TPN 40 Amps 415 volts 10 KA, 'C' curve rating complete all as specified and directed.
S & F MCB 4P MCB enclosure with 63 Amps 415 volts 10 KA, 'C' curve rating TPN MCB complete all as specified and directed.
S & F D line weekly digital time switch with white backlit LCD display including taking down old unsv switch complete all as specified.
Supply and fixing new junction box PVC of size 104 mm x 104 mm x 70 mm with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc including taking down unserviceable one complete all as specified and directed. Make- Hensel Cat Part No. KF 0606B or equivalent as in the list of makes.
Supply and fixing new junction box PVC of size 130 mm x 130 mm x 77 mm with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc including taking down unserviceable one complete all as specified and directed. Make- Hensel Cat Part No. KF 0604B or equivalent as in the list of makes.
Supply/install, testing, commisioning LT feeder pillar box indoor type CPRI approved vermin/weather proof of overall dimension (1200x900x500) mm (leg of the feeder pillar not less than 300 mm in length) made out of 3.15 mm thick CRCA sheet supported on structural frame of angle iron (50x50x6) mm two part hinged door in front side with locking & gasket arrangement duly two coats of powder coated paint interally/externally on the surface incl provn of 04 Nos Al Bus Bar strip of rating 550 Amp (covered with PVC insulated sleeves) fixed on PVC insulators and internal connections with required rating of copper cable and terminals, grouting on PCC foundation as per site requirement as directed by Engr- in-Charge. The FP box consisting the following accessories:- Main Incoming : (i) MCCB 400 Amp, 36 KA, 4 Pole - 01 No Main Outgoing: (a) MCCB 63 Amp,25 KA, 4 Pole - 04 Nos (b) MCCB 250 Amp,25 KA, 4 Pole - 01 Nos Note : (a) PCC foundation/excavation will be measured and paid separately.
Supply/install, testing, commisioning LT feeder pillar box indoor type CPRI approved vermin/weather proof of overall dimension (1200x900x500) mm (leg of the feeder pillar not less than 300 mm in length) made out of 3.15 mm thick CRCA sheet supported on structural frame of angle iron (50x50x6) mm two part hinged door in front side with locking & gasket arrangement duly two coats of powder coated paint interally/externally on the surface incl provn of 04 Nos Al Bus Bar strip of rating 550 Amp (covered with PVC insulated sleeves) fixed on PVC insulators and internal connections with required rating of copper cable and terminals, grouting on PCC foundation as per site requirement as directed by Engr- in-Charge. The FP box consisting the following accessories:- Main Incoming : (i) MCCB 200 Amp, 25 KA, 4 Pole - 01 No Main Outgoing: (a) MCCB 63 Amp,25 KA, 4 Pole - 07 Nos Note : (a) PCC foundation/excavation will be measured and paid separately.
M&L for Cutting channels, grooves or rebates exc 15cm with or without reinforcement but not exceeding 30cm girth, and trimming surface complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation of feeder pillar box complete all as specified and as directed.
Earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (light grade) and other end connected to earthing test point or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete including testing on completion all as specified.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed.
KT CONSTRUCTIONS
RUNJEN CONSTRUCTION
M/s. Bijoy Engineering Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .