Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC Due to lowest | |
| 2 | L2₹12.6 L+₹55,264 (4.61%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹12.8 L+₹75,764 (6.31%)Rejected-Finance | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹12.9 L+₹92,194 (7.68%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹13.8 L+₹1.8 L (15.3%)Rejected-Finance MANDIR ROAD NEW ABADI AKALGARH AIR FORCE STATION HALWARA TEH RAIKOT DISTT LUDHIANA PB 141106 | LUDHIANA | LUDHIANA | PUNJAB | 141106 | L5 | Rejected-Finance other than lowest |
Tender Value
₹14.7 L
EMD Value
₹29,300
Closing Date
10 Jul 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana 141001
Provn of Capacitor bank for external electricity supply under GE Ludhiana.
2020_MES_345460_2
GE/LDH-11/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Under GE Ludhiana
Refer NIT and Tender Document
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹29,300
Yes
30 Aug 2020
18 Jun 2020
11 Jul 2020
18 Jun 2020
10 Jul 2020
24 Jun 2020
18 Jun 2020 - 23 Jun 2020
60 days
Amount
Supplying ,installing and commissioning of 35 KVAR automatic power factor control panel with outdoor application made out of 03 mm thick MS sheet duly powder coated with seven tank pre surface treatment duly powder coated with pure polyester powder,aluminium bus bar of suitable size ,angle iron frame of 50mm*50mm*5mm of length 750mm long to be grouted in PCC block (1:3:6 , type C-2) & as per technical specifications mentioned below 1. 100A 3P 25KA adj. th.&fix mag. MCCB =1 No.as incomer 2. MCB,s 3P 10KA ‘D‘curve as mentioned below 2.1 16A=1 No. 2.2 25A=3 No. 3. Capacitive duty contactors,coil voltage ,240V as mentioned below 3.1 Capacitive duty contactor suitable for 5KVAR=1No. 3.2 Capacitive duty contactor suitable for 10KVAR=3No. 4. Shunt capacitor ,heavy duty tublar as mentioned below 4.1 Shunt capacitor 5 KVAR=1 No. 4.2 Shunt capacitor 10 KVAR=3 No. 5. Automatic power factor correction relay ,three phase ,6 steps,3CTs=1No. 6. set of digital three phase voltmeter =1 No.,digital ammeter three phase =1No. ,set of indicators (RYB), 6A SP MCB=3 No.s 7. On –indicators =7 No. 8. Axial fan for cooling purpose (8 inch)=1No.(Make: As per PS)
Supplying ,installing and commissioning of 50KVAR automatic power factor control panel with outdoor application made out of 03 mm thick MS sheet duly powder coated with seven tank pre surface treatment duly powder coated with pure polyester powder,aluminium bus bar of suitable size ,angle iron frame of 50mm*50mm*5mm of length 750mm long to be grouted in PCC block (1:3:6 , type C-2) & as per technical specifications mentioned below 1. 100A 3P 25KA adj. th.&fix mag. MCCB =1 No.as incomer 2. MCB,s 3P 10KA ‘D‘curve as mentioned below 2.1 16A=2 No. 2.2 25A=4 No 3. capacitive duty contactors,coil voltage ,240V as mentioned below 3.1 capacitive duty contactor suitable for 5KVAR=2No. 3.2 capacitive duty contactor suitable for 10KVAR=4No 4. Shunt capacitor ,heavy duty tublar as mentioned below 4.1 Shunt capacitor 5 KVAR=2 No. 4.2 Shunt capacitor 10 KVAR=4 No. 5. Automatic power factor correction relay ,three phase ,6 steps,3CTs=1No. 6. set of digital three phase voltmeter =1 No.,digital ammeter three phase =1No. ,set of indicators (RYB), 6A SP MCB=3 No.s 7. On –indicators =9 No. 8. Axial fan for cooling purpose (8 inch)=1No.(Make: As per PS)
Supplying ,installing and commissioning of 62.5KVAR automatic power factor control panel with outdoor application made out of 03 mm thick MS sheet duly powder coated with seven tank pre surface treatment duly powder coated with pure polyester powder,aluminium bus bar of suitable size ,angle iron frame of 50mm*50mm*5mm of length 750mm long to be grouted in PCC block (1:3:6 , type C-2) & as per technical specifications mentioned below 1. 100A 3P 25KA adj. th.&fix mag. MCCB =1 No.as incomer 2. MCB,s 3P 10KA ‘D‘curve as mentioned below 2.1 16A=2 No. 2.2 25A=4 No. 2.3 32 A=1 No 3. capacitive duty contactors,coil voltage ,240V as mentioned below 3.1 capacitive duty contactor suitable for 5KVAR=2No. 3.2 capacitive duty contactor suitable for 10KVAR=4No 3.3 capacitive duty contactor suitble for 12.5 KVAR=1No. 4. Shunt capacitor ,heavy duty tublar as mentioned below 4.1 Shunt capacitor 5 KVAR=2 No. 4.2 Shunt capacitor 10 KVAR=4 No. 4.3,Shunt capacitor 12.5 KVAR=1 No 5. Automatic power factor correction relay ,three phase ,8 steps,3CTs=1No. 6. set of digital three phase voltmeter =1 No.,digital ammeter three phase =1No. ,set of indicators (RYB), 6A SP MCB=3 No.s 7. On –indicators =10 No. 8. Axial fan for cooling purpose (8 inch)=1No.(Make: As per PS)
Supplying ,installing and commissioning of 75KVAR automatic power factor control panel with outdoor application made out of 03 mm thick MS sheet duly powder coated with seven tank pre surface treatment duly powder coated with pure polyester powder,aluminium bus bar of suitable size ,angle iron frame of 50mm*50mm*5mm of length 750mm long to be grouted in PCC block (1:3:6 , type C-2) & as per technical specifications mentioned below 1. 160A 3P 25KA adj. th.&fix mag. MCCB =1 No.as incomer 2. MCB,s 3P 10KA ‘D‘curve as mentioned below 2.1 16A=3 No. 2.2 25A=2 No. 2.3 50A= 2 No. 3. capacitive duty contactors,coil voltage ,240V as mentioned below 3.1 capacitive duty contactor suitable for 5KVAR=3No. 3.2 capacitive duty contactor suitable for 10KVAR=2No 3.3 capacitive duty contactor suitable for 20KVAR=2No 4. Shunt capacitor ,heavy duty tublar as mentioned below 4.1 Shunt capacitor 5 KVAR=3 No. 4.2 Shunt capacitor 10 KVAR=2 No. 4.3 Shunt capacitor 20 KVAR=2 No. 5. Automatic power factor correction relay ,three phase ,8 steps,3CTs=1No. 6. set of digital three phase voltmeter =1 No.,digital ammeter three phase =1No. ,set of indicators (RYB), 6A SP MCB=3 No.s 7. On –indicators =10 No 8. Axial fan for cooling purpose (8 inch)=1No.(Make: As per PS)
Supplying ,installing and commissioning of 100 KVAR automatic power factor control panel with outdoor application made out of 3 mm thick MS sheet duly powder coated with seven tank pre surface treatment duly powder coated with pure polyester powder ,aluminium bus bar of suitable size,angle iron frame of 50mm*50mm*5mm of length 750mm long to be grouted in PCC block (1:3:6 , type C-2) & as per technical specifications mentioned below 1. 200A 3P 25KA adj. th.&fix mag. MCCB =1 No.as incomer 2. MCB,s 3P 10KA ‘D‘curve as mentioned below 2.1 16A=2 No. 2.2 25A=2 No. 2.3 32A=2No. 2.4 50A= 2 No. 3. capacitive duty contactors,coil voltage ,240V 3.1 capacitive duty contactor suitable for 5KVAR=2No. 3.2 capacitive duty contactor suitable for 10KVAR=2No 3.3 capacitive duty contactor suitable for 15KVAR=2No 3.4 capacitive duty contactor suitable for 20KVAR=2No 4. Shunt capacitor ,heavy duty tublar as mentioned below 4.1 Shunt capacitor 5 KVAR=2 No. 4.2 Shunt capacitor 10 KVAR=2 No. 4.3 Shunt capacitor 15 KVAR=2 No. 4.4 Shunt capacitor 20 KVAR=2 No. 5. Automatic power factor correction relay ,three phase ,8 steps,3CTs=1No. 6. set of digital three phase voltmeter =1 No.,digital ammeter three phase =1No. ,set of indicators (RYB), 6A SP MCB=3 No.s 7. On –indicators =11 No. 8. Axial fan for cooling purpose (8 inch)=2No.(Make: As per PS)
Supplying ,installing and commissioning of 200KVAR automatic power factor control panel with outdoor application made out of 3 mm thick MS sheet duly powder coated with seven tank pre surface treatment duly powder coated with pure polyester powder,aluminium bus bar of suitable size ,angle iron frame of 50mm*50mm*5mm of length 750mm long to be grouted in pcc block (1:3:6 , type C-2) & as per technical specifications mentioned below 1. 400A 3P 35KA adj. th.&fix mag. MCCB =1 No.as incomer 2. MCB,s 3P 10KA ‘D‘curve as mentioned below 2.1 16A=2 No. 2.2 25A=2 No. 2.3 50A =1 No. 2.4 63A =6 No. 3. capacitive duty contactors,coil voltage ,240V as mentioned below 3.1 capacitive duty contactor suitable for 5KVAR=2No. 3.2 capacitive duty contactor suitable for 10KVAR=2No 3.3 capacitive duty contactor suitable for 20KVAR=1No 3.4 capacitive duty contactor suitable for 25KVAR=6No 4. Shunt capacitor ,heavy duty tublar as mentioned below 4.1 Shunt capacitor 5 KVAR=2 No. 4.2 Shunt capacitor 10 KVAR=2 No. 4.3 Shunt capacitor 20 KVAR=1 No. 4.4 Shunt capacitor 25 KVAR=6 No. 5. Automatic power factor correction relay ,three phase ,12 steps,3CTs=1No. 6. set of digital three phase voltmeter =1 No.,digital ammeter three phase =1No. ,set of indicators (RYB), 6A SP MCB=3 No.s 7. On –indicators =14 No. 8. Axial fan for cooling purpose (8 inch)=2No.(Make: As per PS) Note for Srl item No.01 to 06:- No authorisation will be considered .all the respective panels will be inspected at factory premises before dispatch. Contractor shall be provided 02 year warranty for the shunt capacitors & 01 Year for other items. MAKE :-(For item No. 1.01 to 6) MCCB= indoasian,L&T,siemens,schneider MCB,s 3P:= indoasian,L&T,siemens,schneider capacitive duty contactors= indoasian,L&T,siemens,schneider,Neptune Shunt capacotors:- Epcos,L&T,Schneider,siemens,Neptune APFC relay:- Epcos,L&T,Schneider,siemens,Neptune APFC Panels:-Neptune, cmpl,L&T ,Siemens , Indoasian or equivalent as per PS
Supply,laying, jointing and testing XLPE insulated heavy duty multi stranded armoured electric cable with aluminium conductor 1100 volts grade laid in trenches/ ducts/ along poles/ through pipes including taking out existing cable aluminium conductor cross sectional area as followings. Make Havells/KEI/Polycab/CCI
35 Sqmm 3.5 Core
50 Sqm 3.5 Core
95 Sqmm 3.5 Core
150 Sqmm 3.5 core
240 Sqmm 3.5 core
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exc. 1.5 mtr deep for laying of cables and getting out soft/loose soil complete.
M & L, filling dry and clean sand in trenches for cable 8 cm deep below and 15 cm above for cable cushioning complete all as specified . Note :- Thickness of 18 cm after punning shall be considered for payment.
M & L for sub class 'B' brick of size 230x115x75mm laid flat work length equal to width of brick on sand for protection of under ground cable complete.
Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in trenches complete.
Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L, GI Pipe light grade 50 mm dia laid in trenches with all fitting comple all as specified.
M&L, GI Pipe light grade 80 mm dia laid in trenches with all fitting comple all as specified.
M&L,Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level earth plate surrounded by 15cm thick and packed with layer of charcoal dust and common salt earth lead GI strip 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end connecions to main switch board and protected by galvanised iron light grade 40mm dia pipe, 20mm dia pipe for water with funnel, wire mesh, PCC chamber in cement concrete (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC cover complete all as specified and shown in electrical plate in MES Schedule (Part-I).Notes - (i) Outer edge of earth pit will be 1.5 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slantling position. (Earth wire and protection pipe upto 7.50m length is included in the unit rate)
SATISH AND CO
AK Construction Co
Raman Electric Trading Co
Kular and Company
R D Bansal
JASSI TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .