Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹36.2 L+₹1.6 L (4.67%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.6 L+₹3.0 L (8.64%)Rejected-Finance KHATA NO 254 529 KHASRA NO 364 2 MIN PREET NAGAR A GALI NO 2 HARERI ROAD OPP STAR STUDIO HERARI SANGRUR | SANGRUR | SANGRUR | PUNJAB | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹41.4 L+₹6.8 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹44.3 L+₹9.7 L (28.1%)Rejected-Finance V P O BOPARAI KALAN DISTT LUDHIANA 141422 PB | LUDHIANA | LUDHIANA | PUNJAB | 141422 | L5 | Rejected-Finance Being L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Jun 2020, 6:00 pmClosed
HQ CWE AF AMBALA
HQ CWE AF AMBALA
CA NO CWE/AF AMB/HAL-09/2020-21 SPECIAL REPAIR TO VARIOUS BUILDINGS AT AF STATION HALWARA UNDER GE AF HALWARA
2020_MES_346862_2
CA NO CWE/AF AMB/HAL-09/2020-21
Open Tender
Civil Works
Item Rate
183 days
GE AF HALWARA
All contractors enlisted with MES in Class D and above and Category a i and for unenlisted refer teder documents
8 documents required · 8 mandatory
₹500
Yes
GE AF HALWARA
₹96,000
Yes
23 Jul 2020
11 Jun 2020
29 Jun 2020
11 Jun 2020
27 Jun 2020
15 Jun 2020
11 Jun 2020 - 13 Jun 2020
Amount
Dismantling boarding, any description, fixed in any position with nails including rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Dismantling of timber scantling 40sqcm and over in section in any position unframed work and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Dismantling Asbestos cement plain or corrugated steel sheeting including ridges any gauge/thickness nainital or similar pattern as in roof covering complete all as specified and as directed
Demolition of plain cement concrete,un-reinforced, in ground floor and paving not exceeding 15 cm thick below or above ground floor and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Demolition of mud phuska on roofs, any thickness including mud plastering,whether full thickness removed or only a part thereof and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Dismantling of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water including removal of debries to distance n.exc 500 mtr complete all as specified and directed.
Taking down chowkhats or frames n.exc 1.5 sqm each with shutters without taking off shutters from the frame and removing from site including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed
Taking down chowkhats or frames exc 1.5 but n.exc 4 sqm each with shutters without taking off shutters from the frame and removing from site including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed
Cutting holes brick/stone masonry walls built in cement mortar and making good in CM 1:3 or cement concrete 1:2:4 type B1 exc half brick but not exc one brick thick wall for inserting hold fasts etc complete all as specified and as directed. Note :- Depth of embedded portion of holdfasts or lugs shall be measured from the face of the jamb into the wall.
Forming embankment/earth spreading for traverse wall including raising or lowering earth,spreading in layers n exc. 30 cm thick,watering, & well ramming to obtain maximum dry density at optimum moisture content and finishing to required size, shape etc not exc 1.5 mtr high from the base including rough excavation of earth outside MOD premises from any lead, from the sources as approved including loading/unloading and transportation upto the site of work complete all as specified and as directed.
Forming embankment/earth spreading for traverse wall including raising or lowering earth,spreading in layers n exc. 30 cm thick,watering, & well ramming to obtain maximum dry density at optimum moisture content and finishing to required size, shape etc exc 1.5 mtr and not exc 3.0 mtr high from the base including rough excavation of earth outside MOD premises from any lead, from the sources as approved including loading/unloading and transportation upto the site of work complete all as specified and as directed. Notes for srl No 11 & 12 :- (i) Quoted rates deemed to be include for royality/octroi charges levied by central/state authorities for earth mining and the documentry evidence thereof shall be submitted. (ii) The quantum of earth work involved shall be worked out by levelling method of surveying. (iii) Compaction of earth filling shall be carried out under optimum moisture conditions with standard proctor density not less than 95 per cent of the density obtained in the laboratory by proctor method and a systematic record of these tests shall be maintained. (iv) Each layer shall be compacted by rolling with 08 to 10 tonnes power road roller and sheep foot roller, if required.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
Material and labour for PCC 1:3:6, type C-2 using 12.5 mm graded mechanically crushed stone aggregates as in filling to chowkats complete all as specified and directed.
Material and labour for 25mm thick PCC 1:2:4 type B0 using 12.5 mm graded mechanically crushed stone aggregates as in floor finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B0 using 12.5 mm graded mechanically crushed stone aggregates over roof slab as in padding to make good the depressions/undulations complete all as specified and as directed.
Material and labour PCC 1:2:4 type B-0 using 12.5 mm graded mechanically crushed stone aggregates as in coping, bed plated,kerbs and the like , rounded or moulded etc including weathering slightly rounded or chamfered angles of throating including necessary form work complete all as specified and as directed..
Material and labour PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregates for fixing of angle iron posts etc and the like , rounded or moulded etc including weathering slightly rounded or chamfered angles of throating including necessary form work and finishing the exposed surfaces fair & even without using extra cement complete all as specified and as directed..
Material and labour for 75mm thick PCC 1:3:6 type C-1 using 20mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed. Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length,12 mm wide. (ii) 50 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume.
Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Material and labour for Brick work straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 using old bricks retrieved from srl No 06 here-in-before after cleaning and washing complete all as specified and as directed.
Material and labour for coloured vetrified ceramic light shade coloured tiles, 10mm thick of size not exc 0.36 sqm each over and including 20 mm thick screed bed or bedding layers in Cement Mortar 1:4 as in floors etc. set and jointed in neat cement slurry or adhesive as per manufacturer's instructions and pointed in white or coloured cement to match with existing shade complete all as specified and as directed. Notes for srl No 23 :- (i) The rates includes for all straight cutting and waste including raking or circular cutting. (ii) All corners in tiling should be properly metred jointed to give monolithic uniform apprearance. (iii) The rates for tiling includes for laying to any pattern with one or more colour as directed. (iv) If tiles of different sizes are used then no price adjustment shall be made.
Material and labour for rendering 15 mm thick in CM 1:6 finished even and smooth without using extra cement on fair faces brick or concrete surfaces complete all as specified and directed.
Material and labour for rendering 15 mm thick in CM 1:4 finished even and smooth without using extra cement on fair faces brick or concrete surfaces complete all as specified and directed.
Material and labour for rendering 10 mm thick in CM 1:3 as in ceiling and on the soffits of chajjas/sunshade etc finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 15 mm thick bedding layer in CM 1:3 on cleaned RCC roof slab surfaces mixed with WPC @ 3 % by weight of cement , finished even and fair without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately as supply only.
Supply only integral water proofing compound complete all as specified and as directed.
Supply and fixing pressed steel door frames of size 105 mm x 60 mm with one or more rebates including fixing necessary lugs, 3 Nos 100 mm long hinges per shutter ,lock strike plate etc. including making good the disturbed portion to match with existing finishes complete all as specified and as directed.
Supply and fixing 32mm thick flush shutter, factory made, solid core construction with block board and plywood face panel commercial type on both side complete all as specified and as directed.
Supply and fixing aluminum handle, cast type, anodized 150mm long, complete all as specified and as directed
Supply and fixing 150 mm long Aluminium anodized barrel tower bolt of extruded section complete all as specified and as directed
Supply and fixing sheet glass 4mm thick ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane fixed with oil putty or wooden beads including provision of glazing pins/ spring clips wherever necessary complete all as specified and as directed.
Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or stainless steel wire staple complete all as specified and directed.
Supply and fixing steel windows or ventilators, with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars including a shop coat of primer complete all as specified. Notes: - Glass, wire gauge shall be measured & paid separately.
Supply and fixing mild steel framed work as in door or gate of angle or other sections with gusset plates, rails, braces etc, using ornamental design as approved complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and purpose made hinges or steel hanging door fittings exclusive of steel sheeting or other covering, running rails and guides and hanging, fastening and fixing complete conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply and fixing 1.0 mm thick plain black sheet , steel gates covering to door chowkhats and simlar work cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams including bending or turning up, mitred angles, etc as required complete all as specified and as directed.
Supply and fixing prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply and fixing prepainted galvalume aluminium zinc coating GI based plain sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in ridges fixed with self tapping screws complete all as specified and directed. Note for srl No 38 & 39 :- The net area of sheeting as fixed shall be measured on the flat (not girthed to corrugations) without any extra allowance for lapse.
Supply and fixing mild steel flat iron as in hold fast, wall ties,clamps, band, strap etc conforming to fe-410-0 or fe-310-0 complete all as specified and as directed.
Supply only of MS work as in grill,guard bar etc welded to window frame conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Supply and fixing rolled mild steel work in tubular trusses including vertical member, rafter and purlin including special shaped washer etc using ERW or induction butt welded tubes conforming to IS 1161-1979 graded st- 240 including cutting to dead length, notching, drilling riveting and/or welding & connecting with nuts & bolts complete all as specified and as directed.
Supply and fixing aluminium die cast body door closer hydraulically regulated, designation No. 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
Supply and fixing mortice lock vertical type 100 mm size,brass, 4 levers with duplicate keys complete all as specified.
Supply and fixing PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints, as in soil, waste & vent pipes , fixed to wall horizontly/ vertically with suitable size FI clamps of size 25mmx3mm, after taking down/out pipe as existing at site complete all as specified and as directed.
Raking out existing filling from dummy joint,expansion & construction joint for width exc 26 mm but not exc 36 mm upto reqd depth by special tools like concrete cutter,wire/coir brushes/machines and joint cleaned thoroughly with application of compressed air,making free from all loose material i.e. dirt, dust, grease, existing sealing compound, filler board as reqd including sticked material of existing compound raked upto full depth of joint , filled with polyurethane joint sealant single component using mechanical means to a depth 10 mm (depth above the backup rod) with minimum performance guarantee of 05 years from the physical date of completion and minimum movement accn factor (MAF) +/- 30 % conforming to BS:5212 and EN-141875 of 2003 for hydrolysis/ water resistance test with and including applying two coats of primer & filling the balance raked depth of joint with backup material i.e. closed cell polythylene to ensure tight packing so that no gaps or void exist at the top of back up material, seperated by bond breaker tape over suitable size HD 10 filler board in position where reqd complete all as per manufecturer's instructions and as specified or as directed.
Supply and fixing anodised aluminum snap grid frame work of size 605 X 605 mm as in false ceiling for fixing ceiling board with and including necessary notching of anodised aluminum main / cross tee of size 36.5 mm X 25 mm X 1.4 mm weighing 0.24 Kg / RM and 23.5 mm X 26.4 mm X 1.40 weighing 0.191 Kg per RM respectively and frame work shall be fixed to ceiling with supporting hanger consisting of 3.15 mm dia GI wire with necessary bolts, nuts and washers, main and cross tee shall be jointed at junction / crossing with anodised aluminum angle bracket of size 15 mm X 15 mm X 1.50 mm weighing 0.12 Kg / RM fixed with suitable MS bolts, nuts and washers , supported at ends all along the wall with anodised aluminum angle of size 40 mm X 25 mm X 2 mm weighing 0.36 Kg / RM fixed to walls with suitable arrangements, complete all as specified & as directed. Note:- Ceiling board shall be measured and paid separetely.
Supply and fixing calcium silicate ceiling board 6mm thick made of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid as in false ceiling flat or sloping, fixed or laid/inserted to timber/GI/aluminium frame work with screws complete all as specified and as directed. Note:- Frame work and hanging device shall be measured and paid separetely.
Material and labour for APP polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighting not less than 3.6 kg/sqm , black finish reinforced with non-woven polyster (Weight not less than 150 gms/Sqm), with properties of high penetration and centre core consisting of 90 micron, high molecular high density polyethylene (HMHDPE) film consisting of five layers with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 Ltr per Sqm, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm below APP and two coats of water proofing paint with aluminium finish on top of laid APP surfaces, complete all as specified and as directed . Note:- (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor' risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect.
Material and labour for three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
Material and labour for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed.
Material and labour for two coats of Oil bound distemper of approved shade/tint over JK/Birla white wall care putty of any thickness to achieve smooth finish on newly plastered surfaces of wall including preparation of surfaces complete all as specified and as directed.
Material and labour for two coats of Oil bound distemper of approved shade/tint on old plastered treated surfaces of wall including preparation of surfaces complete all as specified and as directed.
Material and labour for One coat of synthetic enamel paint camouflage (disruptive) pattern using approved colour obtained from mix of various percentage of colours on newly plastered surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Material and labour for One coat of synthetic enamel paint camouflage (disruptive) pattern using approved colour obtained from mix of various percentage of colours on old plastered treated surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint over one coat of red oxide primer on new steel and iron surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint on new steel and iron surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint over one coat of pink primer on new wood and wooden based surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring light/fan/bell/socket or power complete fittings such as switches, sockets, ceiling rose, pandent holders, light fittings etc including taking down carefully by unscrewing from board/outlets/DBs/fittings etc such as switches,lamp holdes,brakets,ceiling fittings, bulkhead fittings,sketch fittings, tube light fittings, fan regulators,electric meters, meter bos any type etc and/or drawing out from existing conduit/batten and making good disturbed surfaces of walls/floors/ceilings complete all as specified and as directed .
Material and labour for concealed point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including non metallic rigid PVC concealed conduit not less than 20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly one light, ceiling/exhaust fan point controlled by one way switch 6 amp complete all as specified and as directed.
Material and labour for concealed point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including non metallic rigid PVC concealed conduit not less than 20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly one 3/5 pin socket outlet on the independent board complete all as specified and as directed.
Material and labour for concealed point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including non metallic rigid PVC concealed conduit not less than 20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly one 3/5 pin socket outlet on the same board with other switches complete all as specified and as directed.
Material and labour for concealed point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with stranded copper conductor, in and including non metallic rigid PVC concealed conduit not less than 20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly one 15/16 amp multipurpose socket outlet on independent board complete all as specified and as directed. Note for srl No 60 to 63 :- (i) Switch, socket outlet and fan regulator shall be measured and paid for separately. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match with the existing surfaces.
Supply and fixing switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
Supply and fixing switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed.
Supply and fixing socket outlet, 2 in 1,5 pin, 5/6 amps flush type,240 volts complete all as specified and as directed.
Supply and fixing socket outlet flush type , 2 in 1, 5 pin, 5 & 15 amp complete all as specified and directed.
Supply and fixing in replacement ceiling rose surface bakelite, 65X50 mm three terminals ,230 volts,ISI mark complete all as specified and as directed.
Supply & fixing in replacement bracket holder/angle lamp holder PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
Supply and fixing electronic fan regulator step up flush type,SP 240 volts grade,50 Hz, 100 watts heavy duty including making necessary connections, to make it functional complete all as specified and as directed.
Supply and fixing sheet metal enclosures for MCB SPN 12 way,single phase,DB's with 200 Amp rated copper busbar with neutral link 240 volts AC including connecting incoming and outgoing cable termination with proper tapping, IP-43 protection, double door, fixed flush concealed in walls including making good the disturbed surfaces as per existing specifications after taking down/out enclosure as existing at site including testing & commissioning complete all as specified and as directed.
Supply and fixing sheet metal enclosures for MCB 8 way,single phase,DB's with 200 Amp rated copper busbar with neutral link 240 volts AC including connecting incoming and outgoing cable termination with proper tapping, IP-43 protection, double door, fixed flush concealed in walls including making good the disturbed surfaces as per existing specifications after taking down/out enclosure as existing at site including testing & commissioning complete all as specified and as directed.
Supply and fixing sheet metal enclosures for MCB 4 way,single phase,DB's with 200 Amp rated copper busbar with neutral link 240 volts AC including connecting incoming and outgoing cable termination with proper tapping, IP-43 protection, double door, fixed flush concealed in walls including making good the disturbed surfaces as per existing specifications after taking down/out enclosure as existing at site including testing & commissioning complete all as specified and as directed.
Supply and fixing sheet metal enclosures for MCB 2 way,single phase,DB's with 200 Amp rated copper busbar with neutral link 240 volts AC including connecting incoming and outgoing cable termination with proper tapping, IP-43 protection, single door, fixed flush concealed in walls including making good the disturbed surfaces as per existing specifications after taking down/out enclosure as existing at site including testing & commissioning complete all as specified and as directed.
Supply and fixing in replacement sheet metal enclosures with metal clad socket & plug top with and including one MCB SPN 32 Amp, 'B' curve 240 volts, 10 kA complete all as specified and as directed.
Supply and fixing in replacement MCB 6 to 32 amps,SP,10 kA,240/415 volts with 'C' curve , 50 Hz complete all as specified and as directed.
Supply and fixing in replacement MCB 40 amps,SPN,10 kA,240/415 volts with 'C' curve,50 Hz complete all as specified and as directed.
Supply and fixing in replacement MCCB 100 amps,four pole 415 volt 25kA, fixed thermal and magnetic setting complete all as specified and as directed.
Supply and fixing in replacement MCB 63 amps,TPN,10 kA,240/415 volts with 'B' curve,50 Hz suitable for high inrush current load complete all as specified and as directed.
Supplying & laying sub main wiring with two single core FRLS,PVC insulated cable,1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through with and including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering after taking down/out wiring as existing at site complete all as specified and as directed.. Note :- Two runs of 4 sqmm cable alongwith One run of 2.5 sqmm cable as earth wire with conduit shall be measured as one length.
Supplying & laying sub main wiring with two single core FRLS,PVC insulated cable,1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 4.0 sqmm stranded copper conductor earth continuity cable drawn through with and including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering after taking down/out wiring as existing at site complete all as specified and as directed.. Note :- Two runs of 6 sqmm cable alongwith One run of 4.0 sqmm cable as earth wire with conduit shall be measured as one length.
Supplying & laying sub main wiring with four single core FRLS,PVC insulated cable,1100 volts grade, 10 sqmm nominal cross sectional area stranded copper conductor and two single core green FRLS, PVC insulated 6.0 sqmm stranded copper conductor earth continuity cable drawn through with and including non metallic rigid PVC conduit medium grade of suitable size including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering after taking down/out wiring as existing at site complete all as specified and as directed.. Note :- Four runs of 10 sqmm cable alongwith two run of 6.0 sqmm cable as earth wire with conduit shall be measured as one length.
Supplying, laying, jointing, testing and commissioning under ground electric cable XLPE 1100 Volts grade, heavy duty, PVC insulated screened PVC beeded GI steel strip armoued electric power cable with stranded aluminium conductor, of cross section area 95 Sqmm 3.5 core as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down of old cable as existing at site complete all as specified and as directed. Note:- Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for walls, shafts, manholes not exc 10 Sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as directed
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick each complete all as specified and as directed.
Removal of surplus soil to a distance not exc 500 mtrs & depositing where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and as directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.
Supply and laying sub class 'B' bricks old sizes over the underground HT/LT cable, laid dry & flat abutting each other with width equal to length of bricks for protection of cable after taking down cover as exising at site complete all as specified and as directed.
Supply and fixing GI pipe 40 mm bore , light grade of 0.6 mtr length bent to shape in bracket with and including 02 Nos MS Clamp with nuts, bolts and washers complete all as specified and as directed .
Supply and fixing retrofit LED bulb 15 watts , whight light complete all as specified and as directed.
Supply and fixing energy efficient ceiling fan 230 volt ,1200 mm sweep minimum 3 star rating with all standard accessories and additional accessories like down rods of extra length etc required at site for effective functioning of fan, in and including making connection with three core copper cable of size not less than 1 Sqmm from ceiling rose to connector of ceiling fan of length n exc 3 mtr complete all as specified and directed.
Supply & fixing heavy duty exhaust fan,industrial type, single phase ,230/240 volt AC, 300mm sweep with MS louvers shutter ,turbo force, 1400 RPM, totally enclosed heavy duty motor with copper winding , aluminium rotor mounted on two ball bearing, mounting brackets for fixing with & including cutting holes of suitable size in wall, grouting of nuts and bolt etc required for fixing fan , making good the disturbed portion to match with the existing surface and making connetions with twisted copper flexible wire 23/0.0076mm to make it functional complete all as specified and as directed.
Supply and fixing in replacement LED tube light fitting 1x20 watt fitting four feet length, 230 volts in commmercial channel with powder coated CRCA sheet housing with opal acrylic diffuser for LED with & including LED tubelight with high efficient LED 20 watts in aluminium housing with clear & milky diffuser including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and as directed. Note:- LED fitting should have PF 0.9,CRI>70,L70.
Supply and fixing Bulk head LED fitting 10 watts fixed to eall/ceiling with FI clamps, nuts, bolts, washers etc with and including LED 10 watts and connecting with twin core twisted flexible copper conductor cable of suitable size not more than One mtr and making necessary connection to make it functional after taking down/out fitting as existing at site complete all as specified and as directed.
Supply and fixing of 25 watt LED street light fitting with not less than 100 lumen/watt delivered lumen efficacy supported with LM-79/80, with and including 25 watt LED, cast alluminium alloy housing IP 66 protection, input voltage range 120-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, having FRSR PVC insulated copper cable 3x2.5 Sqmm with and including mounting bracket made of 40mm bore GI pipe medium grade of length not less than 60 cms bent to shape as required fixed with GI clamps of suitable size and numders , nuts, bolts and washers including taking down old existing light fittings all as directed and specified.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed with and including 3 nos, 8mm dia, 25mm long hexagonal head screw complete all as specified and as directed.
Supply and fixing copper strip 20 x 3.15mm in addition for earthing upto test point for fixing after taking down old strips as exists at site complete all as specified and as directed.
Supply and fixing GI pipe 50 mm bore , light grade with fittings fixed to wall with fixing arrangements, ceiling/floors for passing of strip after taking down old pipe as exists at site complete all as specified and as directed .
Supply and fixing air termination single pointed copper rod 12 mm dia, 300mm long duly fixed/secured with PCC or with GI wire supports after taking down/out rod as existing at site complete all as specified and as directed.
Supply and fixing vertical load line TPN prewired distribution board double door type, 8 way, TPN DPX 12-63, with and including MCCB 100 amp ,triple pole and neutral, 16 kA, 415 volts with fixed thermal and magnetic setting as incomer and 04 Nos MCB TPN 40 Amp for outgoing with 63 Amps rated bus bar, flushed inside the wall including making good the disturbed surfaces after taking down DB as existing at site complete all as specified and as directed.
Supplying and fixing flexible copper wire of size one sqmm twin core flat cable for connection complete all as specified and as directed.
Material and labour for earthing complete with copper earth plate 60 cm X 60 cm X 3.15 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to copper earthing strip 20 mm x 3.15 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI medium grade 40mm bore for earthing lead upto 7.5 mtrs, wire mesh, funnel,lugs, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover slab 50 mm thick 1:2:4 type B-1 using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover with CI frame all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion including taking down of existing earthing as exists on site complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to earth lead GI wire 4 mm dia upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade, including protection pipe GI medium grade 15mm bore for earthing lead, wire mesh, funnel,lugs, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover slab 50 mm thick 1:2:4 type B-1 using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover with CI frame all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion including taking down of existing earthing as exists on site all as specified and as directed. Notes for Ser No 103 to 104 :-- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the earth resistance is not obtained, earthing will be generated at NO extra cost ,till the desired earth resistance is obtained.
Deduction of Total of Sch of credit amount Rs 167718.00
M/S SANGA SINGH AND CO
JINDAL AND COMPANY
BEHL AND COMPANY
Deol Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .