Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹11.9 L+₹1.8 L (18.2%)Rejected-Finance 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L2 | Rejected-Finance Being higher bidder |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
28 Mar 2020, 6:00 pmClosed
GE (A) Central Jodhpur
GE (A) Central Multan Line Army Area Jodhpur
REPAIR REPLACEMENT OF SUMMER APPLIANCE AND MISC EM WORKS WATER COOLER REFRIGERATOR DEEP FREEZE AIR CUTRON AND DESERT COOLER ETC UNDER GE A CENTRAL JODHPUR(8927/E8)
2020_MES_333234_1
GE/J/A- of 2019-2020 (8927/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (A) Central Multan Line Army Area Jodhpur
1.Scanned copy of Application and DD Banker Cheque as cost of tender and copy of EMD for unenlisted contractor 2.Copy of GST Registration Number 3.Copy of enlistment letter 4.For unenlisted contractor details of documents meeting enlistment criteria
5 documents required · 5 mandatory
₹500
GE (A) Central Jodhpur
₹19,000
Yes
24 Dec 2020
11 Mar 2020
30 Mar 2020
11 Mar 2020
28 Mar 2020
16 Mar 2020
Amount
PART -I (Water cooler, Fridge & Deep Freezer) (A) WATER COOLERS M & L for disconnecting, loading, unloading and transportation of Water coolers from existing location and position in A/A site for repairing of Water coolers of any make/capacity including reinstallation and testing at site after repairs all as directed by Engr-in-Charge NOTE : (i) Material required for defective / U/S parts shall be paid separately under relevent items.
M&L for checking of Water cooler of any make / capacity in location and position at any site in AA Jodhpur including necessary servicing i.e. making good electrical including copper terminal, cleaning , drain water system including replacement of hose clamp etc . complete , cleaning condensor , condenser fan motor , door gasket , cleaning storage water tank cleaning and testing for proper functioning ofwater cooler all as directed by Engr-in-Charge.( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing , user signature after servicing , concerned JEs signature all as directed by Engineer in-charge )
Material and labour for replacement of unserviceable hermetically sealed compressor of water cooler 150 Ltr storage having cooling capacity 100 Ltrs / hour Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete (Makes :- Tecnomush/Kirloskar copeland) NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturing company (ii) The new unit will be purchased from authorised dealer only as per existing make and model.
All as per ser item No 3 above but for 60/120 Ltr storage capacity with cooling capacity 60 Ltrs / hour water cooler of any make : TECUMSHA/KIROSKAR COPELAND.
All as per ser item No 3 above but for 40/80 Ltr storage capacity with cooling capacity 40 Ltrs / hour water cooler of any make : TECUMSHA/KIROSKAR COPELAND.
Material and Labour for replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hrs
Material and Labour for replacement of of cooper filter and capillary tube of water cooler cooling capacity 60 Ltrs per hour.
Material and Labour for replacement of cooper filter and capillary tube of water cooler cooling capacity 100 Ltr per hour
Material and Labour for replacement of relay with over load protection for 40/80 Ltr/hrs cooling capacity suitable as per site requirement (Make : Ranutrol/Rockwell/Annapurna)
Material and Labour for replacement of relay with over load protection for 60Ltr/hrs cooling capacity suitable as per site reuqirement (Make : Ranutrol/Rockwell/Annapurna)
Material and Labour for replacement of relay with over load protections for 100 Ltr/hrs cooling capacity suitable as per site requirement (Make : Ranutrol/Rockwell/Annapurna).
Material and Labour for replacement of condensor fan motor HP-1/32, RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan bladeISI marked. Make ; AUE or Equivalent
Material and Labour for replacement of condensor fan motor HP-1/16, RPM-1300 suitable for water cooler having cooling cap 60 to100 Ltr/hr with clips and motor fixing stand with fan blade ISI marked. Make ; AUE or Equivalent ISI marked
Material and Labour for Repalcement of thermostat switch with knob for water cooler, having cooling capacity 40/60/150 Ltrs/hr (Make : Rasnutrol no 1051 or Indfoss No 2064/Annapurna)
Material and Labour for patch repair work of worn out MS body of water cooler any capacity made out of 22 gauge mild steel sheet including welding and making good with paint to match with existing all as specified and directed by Engineer-in-Charge.
Material and Labour for replacement of drain PVC pipe, 25 mm bore for cooling cap 40 Ltr /Hrs 90 cms in length with two Nos mild steel clamps and necessary brass screws etc. all as directed (Make : RAJDOOT/KOHINOOR)
All as per item No. 16 but size 32 mm bore suitable for cooling Cap 60 to 100 Ltrs/Hrs water cooler and not more than 1.00 meter all as directed
Material and Labour for replacement of SS drain water tray made out of 24 gauge stainless Steel sheet of size of 30x12x5 cm deep with necessary GI screws and PVC drain water connection arrangement of size not less than 25 mm dia, all as directed (as per sample)
Material and Labour for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler storage cap 120 to 150 Ltrs , of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour all as specified and directed.
Material and Labour for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler cap 80Ltrs., platic sheet of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour all as specified and directed.
Material and Labour for replacement of rubber magnet gasket fixed with top cover of water cooler of 80/120 litres storage capacity
Material and Labour for replacement of rubber magnet gasket fixed with top cover of water cooler of 150 litres storage capacity
Material and Labour for replacement of worn out bottom base of water cooler foundation frame made out of 1.6mm thick MS sheet for water cooler, & frame work made out of angle iron25x25x3 mm, including cutting welding brazing soldering , making holes for sealed unit , condenser with condensor fan motor , including painting black colour ( two coats ) synthetic enamelled paint over a coat of red oxide primer etc and finishing all as directed by Engineer-in-Charge.
Material and labour for replacement of water cooler body back sheet with 22 gauge mild steel sheet including suitable size( as per existing) and necessary painting, screws etc. all as specified and directed by Engineer-in-Chage
Material and Labour for replacement of water cooler front pannel with 20 gauge mild steel sheet including suitable size( as per existing) and necessary screws/nuts/bolts/washers etc. for 40 ltrs/hour capacity all as specified and directed by Engineer-in-Charge.
Material and Labour for replacement of condensor fan motor mounting stand made out of mild steel sheet 3 mm thick size 400x150 mm and refixing on the existing base all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of foundation stand of water cooler fabricated out of angle iron 25x25x3 mm 1600 mm in length incl. Welding and necessary fitting with patch work to bottom portion of 20 gauge MS sheet size 40x15 cm all as directed.
Supply and fix CP lift cock, 15mm bore made of brass self closing vertical type made of brass nickle chromium plated with CP adaptor and nipple -Make : Mayor/C-Sons/G-Sons
Supply and fix CP push cock, 15mm bore made of brass self closing horizontal type made of brass nickle chromium plated with CP adaptor and nipple -Make : Mayor/C-Sons/G-Sons
M&L for permanent type stiker of size 150x300 mm having following details in letters not exceeding 25 mm all as directed. (i) Machine Srl No. (ii) MES No______________ (iii) Date set to work. (iv) PRB Page No ______________.(v) Location__________________
Material and labour for painting to water cooler of storage cap. 150/120/80 Ltrs spray painting with two coats of synthetic enamelled paint (first quality) including preparation of surface complete Make: ASIAN /BERGER /NEROLAC .
Material and labour for repair to storage water tank of cooler of cooling cap 40 Ltr/hour by soldering / brazing to prevent leakage spots incl. cleaning of water tank and testing complete (NOTE : work is to be carried out in existing position as and where machine in army area)
Material and labour for repair to water tank cooler of cooling cap 60 Ltr/hour cap. by soldering, brazing to prevent leakage spots incl. cleaning of water tank and testing complete (NOTE : work is to be carried out in existing positio as and where machine lyes in army area )
Material and labour for repair to water tank of water cooler of cap. 150 ltrs/hrs, by soldering / brazing to prervent leakage spots incl. cleaning of water tank and testing complete (NOTE : Repairing to be done by the contractor at various location of units).
Material and labour for replacement of starting capacitor 40-60 Mfd oil filled 240 volt AC Supply Make : Asian/Atlas/Epcos/SPAN/Sharda Texla
Material and labour for replacement of starting capacitor 60-80 Mfd oil filled 240 volt AC Supply Make : Asian/Atlas/Epcos/SPAN/Sharda Texla
Material and labour for replacement of running capacitor of 36 Mfd oil filled Make : Asian/Atlas/Epcos/SPAN/Sharda
Material and labour for replacement of running capacitor of 15 Mfd oil filled Make : Asian/Atlas/Epcos/SPAN/Sharda
Material and labour for replacement of running capacitor of 10 Mfd oil filled Make : Asian/Atlas/Epcos/SPAN/Sharda
Material and labour for replacement of running capacitor of 2.5 Mfd oil filled Make : Asian/Atlas/Epcos/SPAN
Material and labour for PVC float valve 15 mm bore with PVC float, ball ISI marked complete with check nut/socket/GI nipple directed by Engineer-in-Charge Make: PRAYAG/ POLYTUFF
Material and labour for replacement of water cooler side panel with 20 gauge MS sheet as per sample incl. necessary screws/nuts/bolts/washers etc for 40/60/150 Ltrs/hour cap all as specified and directed by Engineer-in-Charge
Material and labour for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and gas (using maffron M- 134 gas/ R-22 ), oil complete incl testing and commissioning of water cooler having cooling Capacity 40 Ltrs per hour of any make.
Material and labour for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and Gas (using maffron gas - M-134/R-22 ) charging , oil complete incl testing and commissioning of water cooler having cooling Capacity 60 Ltrs per hour of any make.
Material and labour for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and gas charging of Gas (using maffron gas M-134/R-22 ), oil complete incl testing and commissioning of water cooler having cooling Capacity 100 Ltrs per hour of any make.
Material and labour for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/hr water cooler
Material and labour for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 60/150 Ltr/hrs water cooler
Material and labour for replacement of condenser unit complete suitable for 40 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge
Material and labour for replacement of condenser unit complete suitable for 60 to 100 Ltr/hrs cap. Water cooler including gas chargin flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge
Material and labour for replacement of condenser unit complete suitable for 150 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge
Material and labour for replacement of PVC insulated and PVC sheathed flexible cable , multistranded copper conductor 3 core 48/0.20 cross sectional area superior quality. Make : Plaza/Finolex/Polycab
B - REFRIGERATORS AND DEEP FREEZER M&L,checking of Refrigerators/Deepfreezer of any make / capacity in location and position at any site in AA Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning , door gasket cleaning evaporator cleaning and testing for proper functioning of refrigerators/ deep freezer all as directed by Engr-in-Charge.( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing , user signature after servicing , concerned JEs signature all as directed by engineer incharge )
Material and labour for replacement of unserviceable hermetically sealed compressor of Deep freezer 405/320 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company .(ii) The new unit will be purchased from authorised dealer only as per existing make and model.
Material and labour for replacement of unserviceable hermetically sealed compressor of Refrigerator 310/280 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company .(ii) The new unit will be purchased from authorised dealer only as per existing make and model.
All as per ser item No 54 above but for 165/170/180 /220 Ltr capacity refrigerator.Make tecansha/LG
Material and labour for replacement of relay suitable for 286/310/320 Litres cap. Refrigerator (Make : Renutrol/Shriram/Annapurna/KLIXON)
All as per ser item No 56 but cap 165/220 Ltrs Refrigerator
Material and labour of replacement of thermostat automatic defrost with knob suitable for 165 to 310 liters cap refrigerator (Make : Annapurana/Indofos)
Material and labour for replacement of door gasket of best quality complete suitable for 286/310 litres cap. Refrigerator as per manufacturer's instruction and as directed by Engr-in-Charge.
All as per ser item No 59 above but for 165/220 Ltrs Cap.
Material and labour LED Bulb for pin/screw type, 230 Volts suitable up to 310 Ltrs Cap. Refrigerator as in replacement
Material and labour for replacement of freezer door incl. necessary door springs, screws etc for 286/310 Ltrs Cap. Refrigerator complete all as specified and directed by Engr-in-Charge.
All as per ser item No 62 above but for 165/220 Ltrs cap. Refrigerator.
Material and labour for replacement of door lock with keys-2 nos. for any capacity of refrigerator as per sample approved by Engr-in-Charge.
Material and labour for replacement of PVC accessories and suitable for 286/310 Ltrs Cap. Refrigeraator complete of matching size/ as per sample.
Material and labour for replacement of PVC accessories suitable for 165/170/180 ltrs capacity refrigerator complete of matching colour.
Material and labour for patch work/ door repair (in the outer body of water cooler/refrigerator/Deep freezer with 20/22 gauge PGI sheet upto required length/width &hight incl necessary welding/brazing etc all as directed by Engr-in-Charge.
Material and labour for patch work/ repair of bottom of Deep freezer (Capacity 320/405 ltr) with 22/24 gauge PGI sheet upto required length/width &hight incl necessary welding/brazing etc all as directed by Engr-in-Charge.
Material and labour for replacement of refrigerator door handle of 165 to 320 Ltrs Cap. Of any make and model
Material and labour for repairing to bottom/ foundation of refrigerator any cap. With 20 gauge PGI sheet, angle iron frame made out of 25 X 25 X3 mm angle and incl necessary welding work all as directed by Engr-in-Charge.
Material and labour for replacement of evaporator ( Freezer ) assy with door and fixing brackets complete with screw, jointing of tubes etc and testing of cap220 to 320 Ltrs refrigerator (any make)
All as per ser item No 71 above but of capacity 165/180 Ltr refrigerator.
Material and labour for replacement of condensor unit of refrigerator cap.280/ 286/310/320 Ltrs of any make incl jointing of tubes and testing etc, complete (gas charging will be measure and paid under relevant item separately).
All as per ser item No 73 above but for 165/180/220 ltrs capacity refrigerator.
Material and labour for leakage detection including flushing out system,pressurising,including gas charging(as per existing) suitable for 286/310 ltrs.
Material and labour for leakage detection including flushing out system,pressurising,including gas charging (as per existing ) suitable upto 220 ltrs.
M&L for permanent type stiker of size 150x300 mm having following details in letters not exceeding 25 mm all as directed. (i) Machine Srl No. (ii) MES No______________ (iii) Date set to work. (iv) PRB Page No ______________.(v) Location__________________
Supply and replacement of metal clad enclosure complete with plug and socket duly fitted with MCB SP - 10 Amp.Make: ABB/LEGRAND
Material and labour for sub main /Circuit wiring with 1.5 sq mm copper conductor cable 1100 volts grade conforming to relevant IS and ISI Marke including same size of earth wire and taking out old unserviceable sub main wiring including Making good to distrubed surface all as speciifed and directed .
Supply and replacement of condensor fan motor complete for deep freezer cap.310 to 405 ltrs. In existing location and position as per sample
Material and labour for replacement of timer frost free refrigerator as per sample.
Material and labour for replacement of fan motor double door frost free refrigerator as per sample.
Supply and replacement of PCB as per existing suitable for 220 to 320 Ltrs refrigerator/Deep Freezer
Material and labour for carefully dismentling of automatic voltage stablilzer electronic type of cap up to 5 KVA of any make including replacement of PCB and transformer complete kit reassembling and testing etc complete .
Supply and replacement of 3 Pin Plug Top 16 Amps ISI Marked 230 Volts Make: CONA/PLAZA/Legrand
Supply and replacement of 3 Pin Plug Top 06Amps ISI Marked 230 Volts Make: CONA/PLAZA/Legrand
Material and labour for replacement of PVC Connection pipe ISI Marked 300m long heavy duty.
Material and labour for replacement of PVC stop cock ISI Marked heavy duty.
Part -II(AC Work) M&L for checking of window type air conditioner of any make/capacity (1.5/2 TR ) in location and position at any site in Army Area Jodhpur including necessary servicing .ie. electrical connection/wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil, replacement of micro filter of approved quality, testing for proper functioning of window type air conditioner in situ all as directed by Engr-in-Charge.(The rates quoted are deemed to be included for maintaining complete and proper record of machine ie Make with cap and location , date of servicing, user signature after servicing, concerned JEs signature duly verified by the Engr-in-Charge) Note : (a) Cleaning and decaling of condensing unit and cooling coil with caustic soda mixed water and air blower and sludge etc. all as directed by Engr-in-Charge.(b) Greasing/oiling of blower fan motor.including charging of gas if reqd and cost of gas will be paid seperately under respective item of sch A
M&L checking of split type air conditioner indoor unit of any make and capacity (1.5/2 TR ) in location and position at any site in Army Area unit Jodhpur including necessary servicing .ie. electrical connection/wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil, replacement of micro filter of approved quality and testing for proper functioning of split type air conditioner all as directed by Engr-in-Charge.(The rates quoted are deemed to be included for maintaining complete and proper record of machine ie: make with cap and location , date of servicing , user signature after servicing , concerned JEs signature duly verified by the Engr- in-Charge.(b) Greasing /oiling of blower fan mator including charging gas if reqd and cost of gas will be paid seperately under respective item of schedule A
M & L for disconnecting, existing u/s sealed unit and replacement with new rotery type sealed reciprocating conventional compressure cap 1.5 ton ( for Window type ACs) , including pressuring system checking for leakage in system and flush out the system etc complete ; Make : kirloskar/Tecomusha Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'.
M & L for disconnecting, existing U/S sealed unit and replacement with new rotery type sealed reciprocating conventional compressure cap 2.0 ton AC including pressuring system ,for checking of leakage in system and flush out the system etc complete ,make : kirloskar/Tecomush Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'.
Material and labour for rewinding of blower motor (speed 900 RPM) of window/Split Air conditioner of cap. 1/5 HP any make with super enamelled copper conductor winding wire including replacement of worn out bushes, shaft and capacitor etc and testing complete. Make of winding wire : Atlas/Chetak/Devidayal).
Supply and replacement of running capacitor clip type of cap. 50 MFD, 240 volts 50 cycles for window type air conditioner 1.5 Ton Cap.: (Make : EPCOS/KELTRON/SIEMENS/SHARDA )).
Supply and replacement of starting capacitor clip type of cap. 80-100 MFD, 440 volts 50 Hz for window type Air conditioner (Make : EPCOS/KELTRON/SIEMENS/SHARDA )
All as per ser item No 95 above but of cap. 100/120 MFD for 2 TR Split/window type AC (Make : EPCOS/KELTRON/SIEMENS/SHARDA )
Supply and fixing over load protection with relay No 1622/2085 (Make : Shri Ram/Renutrol/Annapurna) for 1.5 Ton cap. For split/ window type AC.
Supply and fixing over load protection with relay No 1062 (Make : Shri Ram/Renutrol) for split/window type AC, for 2.00 Ton Cap. (Make : Annapurna/Indofoss No 2059/Ranutrol)
Material and labour for replacement of cooling coil for window type AC Cap. 1.5/2.0 TR as per existing make. Etc complete.
M&L for taking out and refixing split type ACs any cap/Make from one location to another location including pressurising the system ,testing and leakage rectification in system , making good disturbed surfaces and testing all as directed by Engr-in-Charge. Note :- Rates are deemed to included for making holes for suction , discharge pipe and condensed water pipe (ii ) extra lenth of copper pipe duly insulated and gas if required shall be paid seperately .
Material and labour for replacement of sub main wiring two run of PVC insulated,1100 volts grade ,FRLS, single core4 sq mm (Nominal area) multistranded copper conductor cable including one 4 Sq mm solid copper conductor PVC insulated cable in and including 20 mm dia rigid PVC conduit ISI marked complete including accessories , junction boxes with sheet top cover and other accessories complete all as directed by Engr-in-Charge. NOTE : Two run of 4 Sq mm and one run of4 Sq mm as earth wire and pipe shall be measured as one length. (Make of cable/PVC Pipe :- Polycab/ finolex/Havels ISI marked)
Material and labour for replacement of cord less remote with control panel suitable for split type AC Cap 1.5/2.0 Ton. Note : Make of remote shall be all as per existing.
Material and labour for replacement of Swing motor of split type AC cap 1.5/2.0 Ton with flapper complete all as directed by Engr-in-Charge.
Material and labour for replacement of PVC condensed water drain pipe 15 mm dia for split type AC complete including providing saddle with clamping arrangement all as directed by Engr-in-Charge and
Material and labour for replacement of copper discharge tube of size 3/8" duly nylon insulated all as specified by Engineer -in-Charge.
Material and labour for replacement of copper suction tube of size 5/8" duly nylon insulated all as specified by Engineer -in-Charge.
Supply and fixing blower motor of indoor unit for 1.5 TON cap split type AC (Make Blue star/Voltas complete as per sample) as in replacement.
Supply and fixing blower motor of indoor unit for 2 TON cap split type AC (Make Blue star/Voltas complete as per sample) as in replacement.
Supply and fixing of indoor unit for 1.5 TON cap split type AC (Make : Blue star/Voltas complete as per sample) as in replacement.
Supply and replace auxillary supply PCB for indoor unit of split type Acs 1.5TON capacity of any make and model as oer sample.
Supply and replace secondary PCB for indoor unit of split type Acs 2 Ton of any make and model as per sample.
M&L checking of split type three phase air conditioner of any make / capacity 7.5/5.5/3.0 in location and position at any site in AA Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil ,replacement of micro filter of approved quality and testing for proper functioning of split type air conditioner all as directed by Engr-in-Charge.( The rates quoted are deemed to be included for maintaining complete and proper record of machine ie: make with Cap and Location., date of servicing , user signature after servicing , concerned JEs signature all as directed by engineer incharge ) (Note : The work is to be carried out in war centre existing location and position. )
Material and labour for ,pressurising complete system of split type three phase air conditioner, checking leakage and flushing out system , rectification of leakages if any and including gas charging using refrigerant M- 404/444/R-22 oil charging complete in compressor /Split type AC cap.7.5/5.5/3 Ton all as directed & with entire satisfaction of Engr-in-Charge (Note : The work is to be carried out in war centre existing location and position. (ii)Cost of Gas will be paid under separately under Schedule 'A' )
M & L for disconnecting, existing U/S sealed unit and replacement with new three phase hermatic sealed rotary compressure cap -4/4.25 ton ( for split type ACs) ,make : HITACHI Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'.
Supply only refrigerant gas M- 404/444/R22, Make:Maffron/Floron ( Note : (i) The gas is to be supplied in cylinder duly sealed by manufacturer/ factory sealed with proper PVs and other documents .
Supply and replacing blower motor of indoor unit for 7.5 TON cap split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement.
Supply and replacing blower motor of indoor unit for 5.00/3.5 TON cap split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement.
Supply and replace PCB for indoor unit of three phase split type Acs any capacity / make:HITACHI
Supply and replace PCB for Out door unit of three phase split type Acs any capacity / make:HITACHI
Supply and replace contractor for outdoor unit of Three phase split type Acs any capacity / make as per existing /sample.
Supply and replacing fan motor of outdoor unit for 4/5 Ton cap Three phase split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement.
Supply and replacing fan motor/Blower motor for out door/indoor for 3/3.5 TON cap three phase split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement.
Material and labour for carefully dismentlling of automatic electronic voltage stablizer of cap 4KVA/5 KVA of any make and replacement of PCB and transformer complete unit reassembling and testing complete.
SCHEDULE 'A' Part-III Material and labour for ( in existing location and position) taking out and refixing after repairs, including rewinding of Desert Cooler fan motor of any make, 3 speed,1400 RPM of capacity 1/5 HP with super enameled copper winding wire of appropriate size ( as per existing ) . Make of winding wire : DEVIDAYAL /CHETAK complete
Supply and replacement of bush for cooler fan motor as per existing sample
Supply and replacement of shaft for cooler fan motor as per existing sample
Supply and replacement of oil filled capacitor 4.00 MFD for desert cooler fan motor Make : EPCOS/SHARDA/KENSTAR
Material and labour for replacement of bottom tank and top ( in existing location and position) of approx size - 750 X 750 X 200 mm ( as per existing ) for Desert Cooler made out of 18 gauge PGI sheet with and including two coats of synthetic enamel painting over one coat of red oxide primer on the new surfaces to match with existing surface outside and inside surface with approved quality paint including leakage testing complete all as directed by Engineer-in-charge.
Material and labour for ( in existing location and position ) replacement of front grill ( as per existing )( horizontal and vertical members moveable) of the Desert Cooler made out of 20 gauge PGI sheet with Name plate complete all as approved by Engineer-in-charge.
Material and labour for replacement of side supporting columns to be fabricated out of 20 gauge PGI sheet of size 80x80x800 mm with and including necessary nut, bolts etc .all as directed by Engineer-in-charge.
Material and labour for replacement of side/rear panel made out of 22 gauge PGI Sheet with suitable handles with and including two coats of synthetic enamel paint over one coat of red oxide primer to match with the existing desert cooler all as directed by Engineer-in-charge.
Material and labour for painting to old steel surfaces of Desert cooler capacity up to 5000 Cft with one coat of synthetic enamel spray paint hammer tone paint of approved colour over one coat of red oxide primer on external surface and one coat of anti corrosive black paint inside the Body tank and side grills over a coat of red oxide primer complete including scraping/rubbing with wire brush on old surface of Desert cooler and writing of MES No etc complete at site or at E/M store yard all as specified and directed by Engineer-in-Charge .
Material and labour for replacement of Desert Cooler fan motor capacity 1/5 HP three speed, 1400 RPM single phase with aluminium fan blade, bracket supporting stand complete all as directed by Engr-in-Charge . Make: Crompton/ GEC/COOL HOME.
Material and labour for replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt complete all as directed by Engr-in-Charge . MAKE : RADO KR-1900/Khaitan/Coolhome
Material and labour for replacement of Wood wool pad for Desert Cooler of size 500 x 550 x30 mm (set of three pads) superior quality including binding properly with GI wire of 16 SWG with grill complete all as directed by Engr-in-Charge .
Material and labour for replacement of MS weld wire mesh having apparture size 25 mm and fitted in side grills/rear complete all as directed by Engr-in-Charge.
Material and labour for replacement of Wood wool pad Heavy duty for Desert Cooler of suitable size (set of three pads) superior quality including binding properly with GI wire of 16 SWG with grill complete all as directed by Engr-in-Charge .
Material and labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 1.0 Sqmm cross sectional area superior quality complete all as directed by Engr-in-Charge .. Make: Plaza/Finolex
Material and labour for replacement of PVC water distribution cup of one inlet and 3 outlets fixed with MS nuts and bolts complete (as per sample) all as directed by Engr-in-Charge .
Material and labour for replacement of PVC elbow suitable for desert cooler (as per sample) all as directed by Engr-in-Charge .
Material and labour for replacement of PVC pipe 15 mm dia heavy duty for Desert Cooler Pump complete all as directed by Engr-in-Charge .
Material and labour for replacement of 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz all as directed by Engr-in-Charge . Make :CONA / VINAY/Anchor
Material and labour for replacement of 3 pin plug top cap 15 Amp single phase AC Supply 240 Volts all as directed by Engr-in-Charge . Make :CONA / VINAY/Anchor
Material and labour for replacement of motor fixing ring (not less than 25 mm width ) for desert cooler eight screw / clip type(asper sample) complete all as directed by Engr-in-Charge .
Supply and replacement of 4mm thick ply ISI marked duly making hole for fixing single cooler in window of approximate size 1.5X1.2 mtrs for cooler grill approximate 24"X24" to be replaced in existing location and position in army area complete all as directed by Engr-in-Charge .
M&L for taking down desert cooler installed at ground floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position complete all as directed. NOTE: Any replacement of spare shall be measured and paid separately under respective item of schedule 'A'.
M&L for taking down desert cooler installed at first floor /second floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position complete all as directed. NOTE: Any replacement of spare shall be measured and paid separately under respective item of schedule 'A'.
Supply and fix in existing location and position PTMT stop cock 15 mm dia high pressure screwed for iron pipe Make: PRAYAG/POLYTUFF
Supply and fix in existing location and position PTMT Ball valves 15 mm dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe Make: PRAYAG/POLYTUFF
M & L for wiring for circuit / sub main wiring alongwith earth wire with the following sizes of FR PVC insulated , multistranded copper conductor cable ,( 2 X 1.5 Sq mm + 1X 1.5 Sqmm ), single core drawn in and including PVC casing capping 25 mm width , to be fixed on surface/ ceiling complete all as directed by Engr-in-Charge .
Supply and replace PVC moulded box of switch socket combination of cap - 15 Amp , Make : ANCHOR/ LEGRAND
Note for all above items:-All items in BOQ are forMaterial and labour /Supply and fix and to be executed in "Repairs" only unless otherwise specifically mentioned as "Supply only" or "fixing only" in BOQ. Contractors are requested to quote their rates accordingly.
mahalaxmi enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .