Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance VILLAGE KUMRADI MANGLOUR ROORKEE HARIDWAR 247656 | HARIDWAR | UTTARAKHAND | 247656 | Admitted-Finance |
| 3 | Rejected-Technical VILL BHAGWANPUR LANDORA ROORKEE HARIDWAR | HARIDWAR | UTTARAKHAND | 247656 | Rejected-Technical techno-commercially disqualified |
Tender Value
Refer Docs
EMD Value
₹51,000
Closing Date
26 Dec 2024, 1:00 pmClosed
Superintending Engineer Civil OandM
Superintending Engineer, Civil OandM, PTCUL, Vidyut Bhawan, Near ISBT Crossing,Saharanpur Road, DEHRADUN
Annual MandR works of at 400 Kv Substation Kashipur
2024_PTCU8_78543_1
02/SE(C)/OandM/PTCUL/2024-25
Open Tender
Civil Works - Buildings
Item Wise
365 days
Kasipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
EE Civil OandM PTCUL
₹51,000
Yes
26 May 2025
6 Dec 2024
26 Dec 2024
6 Dec 2024
26 Dec 2024
6 Dec 2024
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : long the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Cold twisted bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :2nd class teak wood 50 x 20 mm
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :20 mm dia
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete :125x90x4.00 mm
Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete :100x75x3.50 mm
Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete :75x60x3.10 mm
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :150x10 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :100x10 mm
Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete : 250x20x6 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 75 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement:6 coarse sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Removing dry or oil bound distemper water proofing cemnet paintand the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm)
Renewal of old putty of glass panes (length)
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
Cleaning of choked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Long pattern W.C Pan of size 580x440 mm
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in?Charge.
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer?in-Charge. (a) Internal Work- Exposed on wall
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White
Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 10 litre (full flush) capacity-white
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing soil, waste and vent pipes :100 mm dia Sand cast iron S&S pipe as per IS: 1729
Providing and fixing soil, waste and vent pipes :75 mm dia Sand cast iron S&S pipe as per IS: 1730
Providing and fixing plain bend of required degree.100 mm dia Sand cast iron S&S as per IS - 1729
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.75x75x75 mm Sand cast iron S&S as per IS - 1729
Providing and fixing single equal plain junction of required degree :100x100x100 mm Sand cast iron S&S as per IS - 1729
Providing and fixing single equal plain junction of required degree :75x75x75 mm Sand cast iron S&S as per IS - 1729
17.47 Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x75 mm Sand cast iron S&S as per IS - 1729
Providing and fixing terminal guard :100 mm Sand cast iron S&S as per IS - 1729
Providing and fixing terminal guard :75 mm Sand cast iron S&S as per IS - 1729
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall- 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall- 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall- 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.for external work-20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.for external work-25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.for external work-32mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.for external work-40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.for external work-50 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.for external work-65 mm nominal dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall:32 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :15 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 32 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
Providing and fixing brass stop cock of approved quality :15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 15 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 32 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 50 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 65 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.53.1 15mm nominal bore
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group B
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 2 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulate copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.40mm
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 5/6 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 6 pin 15/16 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required Bell push
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supplying and fixing brass batten/ angle holder including connection etc. as required
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. 63A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.63 A
Providing Carpenter Service for 8 hours service in a day or part as per requirement by experienced carpenter with necessary T&P for attending minor type of repairing work as directed by the Engineer in charge (DSR Labour rate item 0111 + 15% C.P.)
Providing Fitter for plumber Service for 8 hours service in a day or part as per requirement by experienced plumber with necessary kit for attending minor type of all water supply defects as directed by the Engineer in charge (DSR Labour rate item 0116 + 15% C.P.)
Providing Beldar Service for 8 hours service in a day or part as per requirement to carry out the works as directed by the Engineer in charge (DSR Labour rate item 0114 + 15% C.P.)
Providing Wireman Service for 8 hours service in a day or part as per requirement by experienced electrician with necessary kit(holding license and T&P ) for attending all type of electrical defects as directed by the Engineer in charge (DSR Elec. Labour rate item Elec. 1001 + 15% C.P.)
Providing tractor with trolley for disposal of dismantled material as desired by Engineer in charge for other work required at site(DSR Labour rate item 0039+ 15% C.P.)
Supply, installation, testing & commissioning of 1x40 watt fluorescent tube light fitting of Super strip "Havells" make with requisite accessories like electronic ballast, starter, tube etc. including supply of all materials,labour T&P etc. required for proper completion of work (Based on market rate+DSR -1.41)
Supply, installation, testing & commissioning of ceiling fan "Havells" make ES - 50 premium 5 tar rating model fan sweep 1200 mm, including wiring the down rods of standard length (up to 30 cm with 1.5 sqmm FR PVC insulated copper conductor, single core cable, including providing & fixing phenolic laminated sheet cover on the fan box etc as required. (Based on market rate + DSR 1.45)
S/F of Ventilating fan 300 mm dia, Hevell's make "Ventil Air-DB" including supply of all materials, labour T&P etc. required for proper completion of work (Based on market rate+DSR-1.50.1)
Operation of tube well daily by a suitable experienced operator continuously or in different intervals as per programme fixed by the E/I including opening & closing of valve , changing of fuse wire et. As required for proper running of tube well.
Sweeping of colony roads and surrounding area of residences and disposal of debris/garbage up to the nearest dustbin as per time schedule approved by E/1 including cost of all labour and T&P etc. required for proper completion of work
Cleaning of drains upto 0.30 in wide and disposal o debris/garbage up to nearest dustbin including sprinkling of lime powder near drain as per schedule approved by E/1 including all labour, material and T&P etc. required for proper completion of work.
Cleaning of Nala more than 0.30 in wide and disposal of debris /garbage up to nearest dustbin including sprinkling of lime powder near nala as per schedule approved by E/1 including all labour, material T&P etc. required for proper completion of work
Disposal of garbage/ debris from dust bins of places as directed by E/1 outside the sub-station area including sprinkling of white lime powder in dustbins and surrounding area including cartage, labour, material and T&P etc. required for proper completion of work.
Manual Chlorination of water by adding bleaching power as per direction by Engineer in charge including all labour T&P etc. required of proper completion work.
Rewinding of burnt exhaust fan with approved copper wire including cost of all material, labour, T&P etc. complete ( Burnt wire shall not be taken back)
Rewinding of burnt ceiling fan with approved copper wire including cost of all material, labour, T&P etc. complete ( Burnt wire shall not be taken back)
Supply and replacing of broken bearing of ceiling fan, including all material T&P and labour etc. required for proper completion of work
Taking of defective ceiling fan from position and rehanging after receiving the repaired fan and proper connection etc.
Supply and replacing of 16 A 240 V , cutout of approved make on board including all material, T&P and labour etc. required for proper completion of work.
Supply and replacing of 32 A 240 V , cutout of approved make on board including all material, T&P and labour etc. required for proper completion of work.
Supply and replacing of 15mm dia tee/socket/elbow/bend/nipple etc. for repair of pipeline completeincluding supply of all material, labour ,T&P and Polishing etc. required for proper completion of work.
Supply and fixing of 22 Gauge aluminium sheet of approved quality including cuting, wastage and fixing the same over wooden door shutters by nails including the cost of all materials, labours, T&P & Polishing etc. required for proper completion of work.
Cleaning of septic tank by removal of sludge through sludge pump attached with tractor/Manually including disposal of waste outside the corportion area as per direction of Engineer-in-charge including cartage, labour and T&P.
Hiring charges of welding machine for 8 hours per day with all labour T&P and including welding rod as required for proper completion of work.
Supplying of Drinking water (5000 litre water tanker)at satisfaction from source of municipal water supply including all T&P,labour as rerequired for proper completion of work
Hiring charges of JCB/Crane for 1 hours per day including all T&P labour as required for proper completion of work.
Extraction of defective submersible pump and motorwith 60'-150' column pipe and then lowering of the repaied pump and motor with pipe and testing the same including checking mains cutout fuses and operation of tube well for 24 hours for its smooth working with all cost of material labour T&p etc requird for proper completion of the work.
Disassembling of 7.5HP to 25 HP submersible pump, replacing of damaged bush,impeller, nut&bolt turning of shaft including complete overhauling, and oiling and greasing the pump as required complete job and reassambling the same.
Disassembling of 7.5HP to 25 HP submersible motor from pump and opening its casing, taking out burnt copper PVC wire from its slot and cleaning of slots with sand paper, rewinding with 1.00 Sq.mm, PVC insulated wire of approved make including cost of PVC insulated wire PVC sheet, labour, cartradge tec, required proper completion of job work.(brunt shall not be taken back from contractor)
Supply & installation 3 phase L&T havelles make panel board containing contact relay ,auto start ammeter, volt meter,volt salecter, rotery on-off switch fans kit-kat ,HRC fuse ,start stop button ,push button for bolt meter, indicator ,connector strip housing lock sheet metal housing for 7.5 HP to 25HP pump including supply of all material ,labour and T&P etc required for proper completion of the work.
Supply and fixing star-delta starter with single phase preventer suitable for 10 HP submersible motor – pump of SIEMENS make model no.-3TE0290-OA.7A Ranging from 12.5-20.00 Amp including all labour material cartage etc. required for proper completion of the work
Supply & Fixing flat submersible cable of superior quality as directed by engineer-n-charge (3x2.5) Sq.mm approved make including all material and T&P etc. Complete.
Supplying & Fixing flat submersible cable of superior quality as directed by engineer-in-charge. (3x4.0) sq.mm approved make including all material and T&P etc. Complete.
Providing & Fixing C.P Brass Pillar Cock of approved quality 15 mm nominal bore (weight not less then 400 grms).
Providing and Fixing Bajaj / Philiphs or equivalent make 36 w CFL Including installation, testing and commissioning complete in all respect.
Supplying & Fixing flat submersible cable of superior quality as directed by engineer-in-charge. (3x4.0) sq.mm approved make including all material and T&P etc. Complete.
Providing & Fixing C.P Brass Pillar Cock of approved quality 15 mm nominal bore (weight not less then 400 grms).
Providing and Fixing Bajaj / Philiphs or equivalent make 36 w CFL Including installation, testing and commissioning complete in all respect.
Supply, installation, testing & commissioning of celling fan Havell's make ES-50 5 Star rating model fan sweep 1200mm, including wiring the down rods of standard length (up to 30 cm with 1.5 sqmm FR PVC insulated copper conductor, single core cable, including providing & fixing phenolic laminated sheet cover on the fan box etc. as required. ( Based on market rate + DSR 2014 - 1.45).
S/F of Ventilating fan 300 mm dia, Hevell's make " Ventil Air - DB" including supply of all materials, labour T&P etc. required for proper completion of work ( Based on market rate + DSR 2014 - 1.50.0 ).
P/F Havells or equivalent make C.F.L. 23 watt including instalation, testing and commissioning complete in all respect.
Ashoka Erectors (BID ID -353119)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .