Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance C 199 BULANDSHAHR ROAD INDUSTRAIL AREA GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance NEAR HAPUR ROAD FLYOVER CHW FORGE PRIVATE LIMITED MALIWARA MALIWARA GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance M 91 AMBAD SWATHI ENGINEERS NASHIK VILLAGE TOWN MIDC CITY NASHIK NASHIK MAHARASHTRA 422010 INDIA | NASHIK | MAHARASHTRA | 422010 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 2017 PHASE III GIDC IND ESTATE AHMEDABAD AHMEDABAD AHMEDABAD GUJARAT 382445 | AHMADABAD | GUJARAT | 382445 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
4 Dec 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S Sriram
Technip Energies India Ltd, No.19, Velachery Main Road, Guindy, Chennai 600032
Design, Manufacturing, procurement of materials, testing at manufacturers works, inspection by TPIA, packing, supply of SPECTACLE BLINDS
2023_REFHQ_170977_1
TP/077154C001/000/1393-201/261
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
120 days
IOCL, Gujarat Refinery
Refer Tender Documents
5 documents required · 5 mandatory
Exempted
5 Dec 2023
15 Sept 2023
5 Dec 2023
15 Sept 2023
4 Dec 2023
29 Sept 2023
15 Sept 2023 - 28 Nov 2023
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ12H
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ12J
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ12M
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ12S
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ12V
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ12W
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ12X
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ12Y
18 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2URZ130
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2Y3G4CU
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2Y3G4CY
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2Y3G4D7
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2Y3G4D8
18 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2Y3G4DA
20 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2Y3G4DB
24 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2Y3G4DC
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: C4T8S502
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: C4T8S506
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: C4T8S50E
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C1VR02PV
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C1VR02PW
20 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C1VR02R0
24 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C1VR02R1
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR.Ident Code: C77CF8ZV
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CKA9T1M
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CKA9T1N
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CKA9T1U
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CKA9T1W
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CKA9T1Y
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CKA9T20
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CKA9T21
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: CKASUNZ
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: CKASUP0
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR.Ident Code: C1VLMXES
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR.Ident Code: C1VLMXET
18 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR.Ident Code: C1VLMXEW
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, IBR.Ident Code: C1VNDCS4
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKEK
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKEX
24 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKF3
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, Hydrogen Service. Ident Code: C36R3M7V
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm. Ident Code: C4G30S55
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C4YJ0SGM
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, IBR., Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C77CF8VX
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C792N0FS
24 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C8FX7KC4
.5 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CANLPW3
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: CANUPV2
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: CANUPV4
16 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: CMMK0M7
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1VMR70J
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm. Ident Code: C2UETPG0
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm. Ident Code: C2UETPG2
28 IN Paddle Blind & Spacer, Prj Std, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.47 Series B, -, 300 Lbs, -, -, -, -,Ident Code: C2UR932B
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. ,Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. Ident Code: C77CF9KJ
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RTJ Flanges, as per ASME B16.5, -, 1500 Lbs, -, -, -, -,Ident Code: C77CF9U5
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. , C.A. = 4.5 mm. Ident Code: C77CF9WT
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RTJ Flanges, as per ASME B16.5, -, 2500 Lbs, -, -, -, -,Ident Code: C77CF9ZH
16 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RTJ Flanges, as per ASME B16.5, -, 1500 Lbs, -, -, -, Hydrogen Service. , C.A. = 4.5 mm. Ident Code: C77CFAKT
8 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RTJ Flanges, as per ASME B16.5, -, 1500 Lbs, -, -, -, Hydrogen Service. , C.A. = 4.5 mm. Ident Code: C77CFAKV
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2VDYRM8
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2VDYRMA
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C2VDYRME
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. Ident Code: C77CF8TP
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. ,Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. Ident Code: C77CF9KM
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Hydrogen Service. ,Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. Ident Code: C77CF9YC
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. Ident Code: C8DPNCG1
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1H99NDA
18 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1H99NDC
24 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1H99NDE
26 IN Paddle Blind & Spacer, Prj Std, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.47 Series B, -, 150 Lbs, -, -, -, -,Ident Code: C1H99NDF
32 IN Paddle Blind & Spacer, Prj Std, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.47 Series B, -, 150 Lbs, -, -, -, -,Ident Code: C1H99NDJ
36 IN Paddle Blind & Spacer, Prj Std, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.47 Series B, -, 150 Lbs, -, -, -, -,Ident Code: C1H99NDL
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1Y07CKM
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2U6E5TN
18 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C57GNN0Z
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C57GNN1E
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C57GNN1H
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C77CF9WH
18 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C77CFANA
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Galv. as per ASTM A153, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. Ident Code: C57GNN0S
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.317L, Between RTJ Flanges, as per ASME B16.5, -, 2500 Lbs, -, -, -, Hydrogen Service. Ident Code: C77CF9RS
8 IN Paddle Blind & Spacer, ASME B16.48, ASTM A240 Gr.317L, Between RTJ Flanges, as per ASME B16.5, -, 2500 Lbs, -, -, -, Hydrogen Service. Ident Code: C77CFAL3
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.321, Between RTJ Flanges, as per ASME B16.5, -, 2500 Lbs, -, -, -, Hydrogen Service. Ident Code: C4M1Y57S
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A240 Gr.321, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, Hydrogen Service. Ident Code: C7862TGL
16 IN Paddle Blind & Spacer, ASME B16.48, ASTM A240 Gr.321, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, Hydrogen Service. Ident Code: C7862TGP
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A240 Gr.321 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C77CFALE
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.304/304L, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: CMMHN0L2
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.304/304L + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. . Ident Code: C77CF9SE
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.316/316L, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1452RG
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.316/316L, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1452RJ
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.316/316L + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,Ident Code: C140JZ4X
16 IN Paddle Blind & Spacer, Prj Std, ASTM A240 Gr.321, Between RTJ Flanges, as per Project Std, -, 2500 Lbs, -, -, -, Hydrogen Service. Paddle Blind & Spacer Dimensions shall be as per Annexure-3. Ident Code: C77ZG2L3 & C77ZG2L4
14 IN Paddle Blind & Spacer, Prj Std, ASTM A240 Gr.321, Between RTJ Flanges, as per Project Std, -, 2500 Lbs, -, -, -, Hydrogen Service. Paddle Blind & Spacer Dimensions shall be as per Annexure-3. . Ident Code: C77ZG2L5
16 IN Paddle Blind & Spacer, Prj Std, ASTM A240 Gr.317L, Between RTJ Flanges, as per Project Std, -, 2500 Lbs, -, -, -, Hydrogen Service. Paddle Blind & Spacer Dimensions shall be as per Annexure-3. . Ident Code: C77ZG2L6
16 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.11 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. , Refer to Axens specification IN-042.123 for additional requirements. Ident Code: C77CFA9W
16 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR.Ident Code: C1VLMXEV
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR.Ident Code: C1VLMXFB
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR.Ident Code: C1VPC2LC
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR.Ident Code: C1VPC2LE
18 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR.Ident Code: C1VPC2LG
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR.. Ident Code: C1VPC2LX
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR.. Ident Code: C1VPC2LY
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKEL
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKEP
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKES
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKEU
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKEY
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKEZ
16 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C2JCKF0
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. . Ident Code: C4YHHNJ1
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. . Ident Code: C4YJ0SGL
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. . Ident Code: C4YJ0SGR
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. . Ident Code: C4YJ0SGX
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. . Ident Code: C4YJ0SGY
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements. . Ident Code: C4YJ0SH0
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. ,Refer to Axens specification IN-042.0 for additional requirements. . Ident Code: C50857WU
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR., Refer to Axens specification IN-042.0 for additional requirements. . Ident Code: C77CF8R8
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CANLPW4
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CANLPW5
1.5 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CANLPW7
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CANLPWA
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CANLPWG
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: CFAB01D
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: CMM55DM
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C13ZKR4Y
16 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1FYHJJ7
24 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C1FYHJJA
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C1VPLAJE
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,Ident Code: C1VR067K
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm. Ident Code: C2UETPFN
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. . Ident Code: C352WGKS
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, C.A. = 4.5 mm. Ident Code: C4M6DDKZ
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RTJ Flanges, as per ASME B16.5, -, 1500 Lbs, -, -, -, Hydrogen Service. , C.A. = 4.5 mm Ident Code: C77CF9P9
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: CFAHUK8
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: CFAHUKB
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: CFB2C2D
16 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, C.A. = 6 mm. Ident Code: C37PVRHY
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. . Ident Code: C77CF8SX
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. . Ident Code: C77CF8TG
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. ,Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. . Ident Code: C77CF9KS
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service. + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service. ,Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements. . Ident Code: C77CF9KY
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.316/316L + Sour Service. , Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,Ident Code: C13YWV8L
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .