Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹4.8 Cr
EMD Value
₹4.8 L
Closing Date
7 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer R and B Division, Palanpur
Construction of New Building of District Industries Center at Palanpur Dist: Banaskantha
368628
23 of 2026-27
Open
Civil - All
Works
Banaskantha
13 documents required · 13 mandatory
₹6,000
Executive Engineer Roads and Buildings Division Palanpur
₹4.8 L
23 Nov 2026
23 Nov 2026
23 Nov 2026
7 Dec 2026
23 Nov 2026
90 days
Name of work :- Construction of New Building of District
Industries Centre at Palanpur, Dist.
Bill of Quantities
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
1 Excavation for foundation upto 1.5 m depth including 504.60 Cum 122.94
sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead.(A) Loose or soft
2 Excavation for foundation upto 1.5 m depth including 547.00 Cum 157.16
sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead.(B) Dense or
3 Excavation for foundation for depth from 1.5 m to 3.0 m 419.00 Cum 170.50
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(B)
Dense or Hard soil
4 Excavation for foundation for depth from 3.0 m to 5.0 m 201.00 Cum 300.03
including sorting out and stacking of useful materials
and disposing of the excavated stuff upto 50 Meter
Lead.(C) Hard Murrum
5 Filling available excavated earth (excluding rock) in 1512.00 Cum 136.92
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each disposited
layer by ramming and watering.
6 Filling in plinth with sand under floors including watering 65.00 Cum 444.76
ramming, consolidating and dressing complete
7 Filling in foundation and plinth with murrum or selected 190.00 Cum 282.08
soil in layers of 20cm. thickness including watering,
ramming and consolidating etc. complete.
8 Providing and laying controlled cement concrete M.150 for 361.00 Cum 4123.83
curing complete including cost of formwork but excluding
the cost of reinforcement for reinforced concrete work in
(A) Foundations, footings,Base of columns and Mass
9 Providing and laying controlled cement concrete M.250 511.00 Cum 4546.62
and curing complete including cost of formwork but
excluding the cost of reinforcement for reinforced concrete
work in (A) Foundations, footings, Base of columns and
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
10 Providing and laying controlled cement concrete M250 and 39.00 Cum 7470.97
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts Column Up to
11 Providing and laying cement concrete 1:4:8 (1- Cement : 4- 19.00 Cum 2741.55
coarse sand : 8- Machine Crushed stone aggregates 40 mm
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
12 Providing and laying controlled cement concrete M.250 84.00 Cum 5897.39
and curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work for Ground and Plinth Beams
13 Providing and laying controlled cement concrete M.200 90.00 Cum 7428.25
and curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Columns, Pillars posts and struts, For All Floors.
14 Providing and laying controlled cement concrete M.200 47.00 Cum 7300.10
and curing complete including the cost of formwork
(Vertical fins and vertical sun breakers.) and
reinforcement for reinforced concrete work in (B) Walls,
for all floor level
15 Providing and laying controlled cement concrete M.200 79.00 Cum 5877.73
and curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Beams For All Floors.
16 Providing and laying controlled cement concrete M.200 114.00 Cum 6324.83
and curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Slab for All Floors.
17 Providing and laying controlled cement concrete M.200 15.00 Cum 6275.49
and curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Lintels For All Floors.
18 Providing and laying controlled cement concrete M.200 9.00 Cum 6987.90
and curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Chajja For All Floors.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
19 Providing and laying controlled cement concrete M.200 9.00 Cum 6770.40
and curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work in (E)
Staircases For All Floors
20 Providing TMT Bar FE 500D reinforcement for R.C.C. 132335.00 Kg. 77.29
work including bending, binding and placing in position
complete for All Floor
21 Providing throating or plaster drip and moulding to R.C.C. 172.00 Rmt 43.05
Chhajja by making 5mm to 15mm wide grove as per design
22 Brick work using Common Burnt Clay building bricks 287.00 Cum 4504.18
having crushing strength not less than 35 kg./Sq.Cm. in
Super structure Above plinth level up to All Floor levels in
Cement Mortar 1:6 (1- Cement : 6 -fine sand)
23 Half brick masonry in common burnt clay building bricks 578.00 Sqmt 686.37
having crushing strength not less than 35 Kg/Sq.Cm. in
Superstructure above plinth level upto All Floor level in
Cement mortar 1:4 (1- Cement : 4 -coarse sand )
(Conventional).
24 Providing & Fixing Chicken mesh for joint between brick 442.00 Sqmt 192.91
work & RCC work fixing with nail & GI washer as per
director in charge
25 Providing 20 mm thick double coat mala cement plaster on 1849.00 Sqmt 349.71
interior brick / concrete work for plastering comprising of
base coat of 12 mm thick cement plaster in cement mortar
(1 Cement : 4 coarse sand) in rough finishing and 8 mm
thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse
sand)finished with trovel including scaffolding curing etc.
10x10 mm groves etc. Complete for All Floors.
26 Providing 10mm thick cement mala plaster in single coat 1158.00 Sqmt 222.58
on brick/concrete walls for interior plastering and finished
even and smooth fininshing with a floating coat of neat
cement slurry in (i)Cement mortar 1:3 (1-cement:3-sand).
Complete for All Floors.
27 20mm thick sand faced cement plaster with Gutka Finish 2030.00 Sqmt 320.70
on walls upto height 15 metres above ground level
consisting of 12mm thick backing coat of C.M. 1:3 (1-
cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1
(1-cement : 1-sand) with 5mm grooves, etc. complete.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
28 Providing Water Proofing Treatment on Sunk Slab 22.00 Sqmt 367.64
including cement concrete flooring 1:2:4 (1-cement : 2-
coarse sand : 4-graded stone aggregate 20mm nominal size)
laid in one layer and finished with a floating coat of neat
cement average 50mm thick to prepare slope including
water proofing chemical etc. Complete for Sunk Slab for
29 Applying two coats of putty & one coats of primer of 3138.00 Sqmt 40.60
approved brand and manufacture on new wall surface to
give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign matter
and sand papered smooth.
30 Wall painting (three coats) with plastic emulsion paint of 1986.00 Sqmt 125.74
approved brand and manufacture on undecorated wall
surface to give an even shade including throughly brushing
the surface free from mortar droppings and other foreign
matter and sand papered smooth.
31 Ceiling painting (three coats) with plastic emulsion paint of 1158.00 Sqmt 131.26
approved brand and manufacture on ceiling and soffits of
slab surface to give an even shade including throughly
brushing the surface free from mortar droppings and other
foreign matter and sand papered smooth.
32 Finishing wall with weather proof exterior emulsion paint 2030.00 Sqmt 185.84
(two coats) with Damp Proof Coating (one coat) on wall
surface to give an required shape even shade after
thoroughly brushing the surface to remove all dirt, and
remains of loose powdered materials.etc complete
33 Providing and fixing pre-cast Rubber Dye / steel Dye inter 326.00 Sqmt 701.90
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 :
including 35 mm Sand layer for levelling and filling the
joint with sand in proper line and level as per guidlines of
IRC : SP 63-2018 etc. Complete.
34 Providing and laying polished Green Marble flooring over 12.00 Sqmt 1419.05
20mm (Average) thick base of cement mortar 1:6 (1-
cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 -
coarse sand) laid over and jointed with grey cement slurry
mixed with pigment to match the shade of slab including
rubbing and polishing etc. complete. (A) 25mm thick
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
35 Providing and fixing Machine cut & Polished Green 14.00 Sqmt 1755.38
Marble Slab in 7.5 cm width Strip flooring for Ramp even
grade over 20mm (Average) thick base of cement mortar
1:6 (1-cement : 6-coarse sand) laid over and jointed with
grey cement slurry mixed with pigment to match the shade
of slab including rubbing and polishing etc. complete. (A)
36 P & L 60 x 60 cm Double Charged vitrified 8 mm thick tile 184.00 Sqmt 1411.98
flooring over 20 mm (average) base of cement mortar 1:6 (
1 cement: 6 coarse sand) on new surface or fixing on
existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color
cement slurry including finised with flush pointing &
cleaning the surface etc. complete
37 P & L 60 x 60 cm Soluble Salt vitrified 8 mm thick tile 360.00 Sqmt 1357.44
flooring over 20 mm (average) base of cement mortar 1:6 (
1 cement: 6 coarse sand) on new surface or fixing on
existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color
cement slurry including finised with flush pointing &
cleaning the surface etc. complete Light shade
38 P & L 60 x 60 cm Soluble Salt vitrified 8 mm thick tile 40.00 Sqmt 1378.65
flooring over 20 mm (average) base of cement mortar 1:6 (
1 cement: 6 coarse sand) on new surface or fixing on
existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color
cement slurry including finised with flush pointing &
cleaning the surface etc. complete Dark shade
39 P & L 60 x 60 cm Matt Finished Anti-skid Porcelene 8 37.00 Sqmt 1411.98
mm thick tile flooring over 20 mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse sand) on new
surface or fixing on existing flooring by adhesive material
including dismentaling of existing flooring and jointed with
color cement slurry including finised with flush pointing &
cleaning the surface etc. complete
40 Providing and laying Double Charged Vitrified tiles 8 to 15.00 Sqmt 1262.50
10 mm thick , 60 x 60 cm in skrting risers of steps and
dedo on 10mm thick cement plaster 1:3 (1-cement : 3-
coarse sand) and jointed with white cement slurry
41 Providing and laying Soluble Salt Vitrified tiles 8 to 10 27.00 Sqmt 1207.96
mm thick , 60 x 60 cm in skrting risers of steps and dedo
on 10mm thick cement plaster 1:3 (1-cement : 3-coarse
sand) and jointed with white cement slurry
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
42 P & L 30 x 30 cm Matt Finished Antiskid Ceramic 10 mm 10.00 Sqmt 1269.57
thick tile flooring over 20 mm (average) base of cement
mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or
fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color
cement slurry including finised with flush pointing &
cleaning the surface etc. complete
43 Providing and laying Ceramic tiles 6mm thick in skrting 281.00 Sqmt 1000.51
risers of steps and dedo on 10mm thick cement plaster 1:3
(1-cement : 3-coarse sand) and jointed with white cement
44 Providing and Fixing 15mm thick 300mm x 300mm 43.00 Sqmt 1057.47
Tactile Warning Tiles (Attention Tiles i.e. Tactile Warning
Surface Indicator {TWSI}) of Johnson Endura Tac Button
Yellow Plus or equvqlent make in flooring laid on 20mm
thick cement mortar 1:6 (1 cement: 6 coarse sand) on new
surface and jointed with cement slurry including finished
with flush pointing & cleaning the surface for all floors as
per detailed drawing etc. complete as directed by Architect
or Engineer in charge. These tiles shall be Antiskid,
Chemical Resistant, Fade Proof, Frost- Heat & weather
Proof, High Flexural Strength, Highly Durable, Stain
Resistance. All Tactile Warning Tiles meet the specific size
and Dimension standards as required by ISO/FDIS
45 Providing and fixing Machine cut, Free edges, Mirror 67.00 Sqmt 1703.87
Polished Green Marble flooring 18mm thick laid on 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-
coarse sand) for Trade & Riser including Half Round
moulding front edge of trade jointed with grey cement
slurry mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
46 Providing and fixing Machine cut, Free edges, Polished 337.00 Sqmt 2420.97
Granite stone slab flooring 18mm thick for vertical
wall/Doors/Windows Sill, Jams for cladding as per design
including full moulded round inside edge and laid on10mm
thick base of cement mortar 1:3 (1-cement : 3-coarse sand)
jointed with grey cement slurry mixed with pigment to
match the shade of slab including rubbing and polishing
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
47 Providing and laying water prooofing treatment with china 443.00 Sqmt 1129.18
mosaic tiles flooring over avg 50 mm C.C. 1:2:4 bedding
maintaining slope for plain and curve surface & 12 mm to
20 mm broken pieces not more than 2.5 cm of ceramic/ of
glazed tiles to be laid over cement mortar 1:3 to plain or
slope and to be tempered to bring mortar creme out upto
surface using white cement including rounding off
junctions and extending them upto 15 cm along the
wall,clearing with water and oxalic acid etc. as directed.
48 Constructing Sandwich Platform of 18mm thick polished 3.00 Sqmt 2760.33
black or selected granite at top and 25 mm thick kota stone
with 75cm height with necessary support using 20mm thick
cement mortar 1:3 for sandwich and fitting at bottom &
edges with waterproof rigid adhesive including making
necessary grooves in walls with vertical support of double
kota stonr sandwich every 60cm centre to centre including
all labour material of approved quality including full
moulded round front edge fixed in wall for partition.
49 Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles 531.00 Sqmt 1807.60
having Tegular edges & 15mm thick Densified edges on the Tile Periphery for
Extra Strength the Light weight calcium silicate ceiling tiles shall have, light
reflection 85% non-combustible as per B.S. 476 part IV, 100% humdity
resistance and also having thermal conductivity 0.043° w/m KC. for the best
thermal insulation. The Light weight calcium silicate tile shall be of approved
texture Fine fissured/Spintone/Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent of size 595 x 595 mm to be laid
on true horizontal level suspended inter locking metal grid of hot dipped
Galvanized Steel sections (Galvanized @120 grams per sqm including both
side) consisting of main 'T' runner suitably spaced at joints to get required
length and size of 24 x 38 mm made for 0.30 mm thick (minimum) sheet,
1200mm centre to centre, amd cross 'T' of size 24 x 28mm made of 0.33mm
(minimum) sheet spaced 1200mm along spaced between main 'T' at 600mm
centre to centre to form agrid of 1200 x 600 mm and secondary cross 'T' of
length 600mm and size 24 x 28mm made 0.30mm thick (minimum) sheet to be
interlocked at middle of the 1200 x 600mm panel to form grid of size 600 x
600mm resting on periphery wall/ partition on parameter wall angle pre-coated
steel of size (24 x 24 x 3000mm wide of 0.40mm thick (minimum) sheet with
help of rawl plugs at 450mm c/c with 25mm long dry wall screw @230 mm
interval and laying 15mm densified edges light weight calcium silicate ceiling
tiles of approved texture (Fine Fissured/Cosmos/Spintones) in the grid
including, cutting /making opening for services like diffusers, grills, light
fittings, fixtures, smoke detectors etc., wherever required, Main 'T' runners to
be suspended from ceilings using G.I. slotted cleats of size 25 x 35 x 1.6mm
fixed to ceiling with 12.5mm dia and 50mm long dash fastners, 4mm G.I.
adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8mm,
spaced at 1200mm centre to centre long main 'T' bottom exposed with 24mm of
all T-sections shall be pre-painted with polyster baked paint, for all heights, as
per specifications, drawings and as directed by Engineer in-charges.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
50 Pro. And fixing single layer gypsum board 12 mm thick 34.00 Sqmt 743.16
sections using board of size 1220 mm x 1830 mm x
mm suspended by GI suspender channel of size 25 mm x
mm with intermediate channel og size 18 mm x 40 mm x
0.8 mm at 1220 mm center to center ceiling section of size
40 mm x 35 mm x 0.55 mm at 457 mm c/c and perimeter
channel A of size 20 mm x 27 mm x 30 mm x 0.5 mm at
edges & drops incl.paper tap sand sofit cleat, anchor
fastener, scoch bolt connecting cleat,joining compound top
coat on ceiling incl.making necy.opening for light
fitting,diffuser etc. comp. as per detail drawing as directed
51 Pro. And fixing single layer water proof gypsum board 12.5 47.00 Sqmt 740.23
mm thick sections using water proof board of size
mm x 1830 mm x 8.0 mm suspended by GI suspender
channel of size 25 mm x 3 mm with intermediate channel
og size 18 mm x 40 mm x 0.8 mm at 1220 mm center to
center ceiling section of size 40 mm x 35 mm x 0.55 mm at
457 mm c/c and perimeter channel A of size 20 mm x
mm x 30 mm x 0.5 mm at edges & drops incl.paper tap
sand sofit cleat, anchor fastener, scoch bolt connecting
cleat,joining compound top coat on ceiling incl.making
necy.opening for light fitting,diffuser etc. comp. as per
detail drawing as directed
52 Providing and fixing flush door with Single shutters, solid 39.00 Sqmt 4129.89
core construction with frame of first class hardwood with
cross board and finished with 1 mm thick laminate on both
side of shutter, machine glued PVC beading on periphery
including 30cm long Stainless Steel Pipe handle on both
side SS ASIS 304 grade, SS Stopper 20cm, SS Aldrop
30cm both side, anodised alluminium butt hinges with
necessary screws. (B) Non-decorative type and block board
core anodised alluminium butt hinges in flush door shutters
(2) 35 mm thick.
53 Providing and fixing WPC (Wood Plastic Composite) with 17.00 Sqmt 5465.11
Single shutters, solid core construction with frame of first
class hardwood with cross board and finished with 1 mm
thick laminate on both side of shutter, machine glued PVC
beading on periphery including 30cm long Stainless Steel
Pipe handle on both side SS ASIS 304 grade, SS Stopper
20cm, SS Aldrop 30cm both side, anodised alluminium
butt hinges with necessary screws. (B) Non-decorative type
and block board core anodised alluminium butt hinges in
flush door shutters (2) 28 mm thick.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
54 Providing, supplying, and installing a double-action 8.00 Sqmt 7575.00
Pivoted flush door assembly consisting of an Anodized
Aluminium Section frame (equivalent to Jindal Section No.
19552, min. weight 1.1 kg/mt) packed with high-density
seasoned wood inserts for durable hardware grip, along
with a shutter framework fabricated from 5cm x 15cm Teak
Wood (T.W.) styles and 6 nos. 5cm x 5cm T.W. internal
rails, flush-covered on both faces with 6 mm thick water
proof ply, finished with both sides decorative laminate of
approved color and shade as selected by the Architect, and
smoothly operated via heavy-duty oil-damped floor springs
with top/bottom pivots and 60cm long S.S. handles on both
faces; including the provision of all materials, hardware
fixtures, fabrication, labor, safe transportation to the site,
loading, unloading, lifting, handling, stacking, and
complete installation in perfect alignment at all levels as
per detailed architectural drawings and directions of the
Engineer-in-Charge.
55 Providing and fixing flush door with Double shutters, solid 25.00 Sqmt 4093.53
core construction with frame of first class hardwood with
cross board and finished with 1 mm thick laminate on both
side of shutter, machine glued PVC beading on periphery,
including 30cm long Stainless Steel Pipe handle on both
side SS ASIS 304 grade, heavy duty Floor Spring each side,
SS Stopper 20cm, SS Aldrop 30cm both side, anodised
alluminium butt hinges with necessary screws. (B) Non-
decorative type and block board core anodised alluminium
butt hinges in flush door shutters (2) 35 mm thick.
56 Providing and fixing three track sliding window with frame 101.00 Sqmt 1604.89
and shutters made from standard extruded colour anodized
aluminium sections, equivalent to Jindal Series-E (30 mm),
comprising shutter top and bottom section No.
shutter interlock section No. 20550, shutter side/handle
section No. 20549, frame bottom with weepholes section
No. 20928 and frame top and side section No.
glazed with 5 mm thick transparent tinted float glass,
complete with additional mosquito net shutter of
aluminium frame fitted with approved quality fibre
glass/nylon mosquito mesh, including rubber gaskets, air
lock strip, silicone sealant for finishing joints, standard
extruded colour anodized aluminium fittings and fixtures,
cutting, fabrication, transportation, assembling and fixing
complete with all materials, labour, tools and tackles, as
directed by the Engineer-in-Charge.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
57 Providing and fixing two track sliding window with frame 5.00 Sqmt 1713.70
and shutters made from standard extruded colour anodized
aluminium sections, equivalent to Jindal Series-E (30 mm),
comprising shutter top and bottom section No.
shutter interlock section No. 20550, shutter side/handle
section No. 20549, frame bottom track section No.
and frame top and side section No. 20837, glazed with
mm thick transparent tinted float glass, complete with
additional mosquito net shutter of aluminium frame fitted
with approved quality fibre glass/nylon mosquito mesh,
including rubber gaskets, air lock strip, silicone sealant for
finishing joints, standard extruded colour anodized
aluminium fittings and fixtures, cutting, fabrication,
transportation, assembling and fixing complete with all
materials, labour, tools and tackles, as directed by the
Engineer-in-Charge.
58 Providing and fixing standared extruded of alluminium 36.00 Sqmt 1525.00
section of size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094Kg /
Rmt with colour anodized alluminium frame with 5 mm
thick transparent bronze colour tinted float glass as details
etc complete for Fix window.
59 Providing and fixing Standard extruded colour anodized 9.00 Sqmt 1368.55
alluminium section frame weight 1.094 kg/Rmt.with
Adjectable Glass Louvers of 5 mm thick transparent glass
colour tinted float glass with transparent silicon gasket with
allu. Powder coated fittings & fixtures.
60 Providing and fixing Louvers in G.I Channel 40x32x5mm 33.00 Sqmt 2215.94
size And 114mm Wide G.I Sheet Having Thickness of
0.55mm & Weight Not Less Than 490 Gm/Mtr. Roll
Formed to create 84mm wide Louver snap fixed on special
shaped G.I Channel,Channel shall be Finished with Powder
Coating of 55 micron For Fix Louvers As Directed By
Engineer In Charge.
61 SIGNAGES ON DOOR :Providing and fixing 304 grade 36.00 Nos. 1262.50
stainless steel 1.5mm thick brushed steel finish plate fixed
on a door using S.S studs and with punched (laser cut)
lettering carried out on S.S plate of required size and text
as directed by engineer etc. complete. Size 30 cm x 15 cm
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
62 Providing erecting and fixing double coated ISI water tank 6000.00 Litre 3.95
of required capacity each with all necessary fittings and
connection etc. complete on terrace
63 Providing, laying and jointing in true line and level 110 432.00 Rmt 1053.74
diameter U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber ring,
& fittings conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be jointed with
each other with rubber lubricant, pipe shall be fixed on wall
using of PVC clamp of the size 110 mm diametre x
mm length x 145 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
64 Providing, laying and jointing in true line and level 160 150.00 Rmt 834.39
diameter U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber ring,
& fittings conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be jointed with
each other with rubber lubricant, pipe shall be fixed on wall
using of PVC clamp of the size 160 mm diametre x
mm length x 196 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
65 Providing laying and jointing in true line and level 50mm 400.00 Rmt 195.67
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
66 Providing laying and jointing in true line and level 40mm 300.00 Rmt 148.12
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
67 Providing laying and jointing in true line and level 25mm 280.00 Rmt 91.84
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
68 Providing laying and jointing in true line and level 15mm 250.00 Rmt 72.65
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
69 Providing and fixing Gun metal check or non-return 4.00 Nos. 663.43
fullway wheel valve.(E) 40mm dia.
70 Providing and fixing Gun metal check or non-return 10.00 Nos. 420.64
fullway wheel valve.(C) 25mm dia.
71 Providing and fixing ball cock of approved. quality as 3.00 Nos. 189.84
directed.(A) Copper Metal (ii) 50mm dia.
72 Providing and fixing wash down water closet (Wall Hung 6.00 Nos. 9212.52
type, W.C. Pan) with integral P or S trap, Health Fauset
Heavy Duty with hook and PVC dual flush tank with
complete fittings including jointing the trap with soil pipe
in Cement Mortar 1:1 (1-Cement : 1-fine sand) (Seal and
cover to be measured and paid for separately)(A) vitreous
China Pattern :(i) in white colour
73 Providing and fixing water closet squatting Pan (Indian 2.00 Nos. 1667.33
type W.C. Pan) size 580mm (Earthwork, bed concrete, foot
reste and trap to be measured and paid for separately) (A)
Vitreous China.(I) Long pattern = White colour including
100mm size P or S trap for water closet squatting pan
including jointing the trap with the pan and soil pipe in
cement Mortar 1:1 (1-Cement : 1-Fine sand) with 25mm
dia. chromium plated brass half trun flush cock of approved
quality including fixing in pipe line xing G.I. inlet
connection for flush pipe with W.C. Pan etc. complete.
74 Providing and fixing Urinal or approved quality including 8.00 Nos. 1074.87
conecting the Urinal with waste pipe , tap etc. complete.(A)
White earthenware flat back or corner type size 430mm x
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
75 Providing and fixing washbasin (ii) Flat Back washbasin 8.00 Nos. 2187.87
550 mm x v 400mm size. (i) In white colour including with
approved sanitary grade material with CP waste coupling,
waste pipe, 15mm dia Pillar & Stop Cock of approved
brand with connection 15mm dia flexiable pvc pipe etc.
76 Providing and fixing Kitchen sink with C.I. or M.S. 2.00 Nos. 2987.88
brackets, painted white including cutting holes in walls (C)
Vitreous China Sink.(i) 600mm x 450mm x 150mm size
including approved sanitary grade material with CP waste
coupling, waste pipe, 15mm dia Pillar & Stop Cock of
approved brand with connection 15mm dia flexiable pvc
pipe etc. complete
77 Providing and fixing screw down bib taps of following 50.00 Nos. 186.83
size.(A) Brass screw down bib tap polished bright. (i)
78 Providing and fixing PVC SWR Nahni trap IS 14735 for 50.00 Nos. 733.26
drain - 100 mm diameter with jali of the following nominal
diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making
good the walls.
79 Providing and fixing S.W. gully trap with C.I. grating brick 8.00 Nos. 1246.92
masonry chamber and water tight C.I. cover with frame of
300mm x 300mm size (inside) with standard weight.(i)
Square mouth traps.(B) 150mm x 100mm size P or R type
80 Providing and fixing C.P. brass towel rail comlete with 16.00 Nos. 616.43
C.P. brass brackets fixed to wooden plugs with C.P. brass
scews.(B) 600mm x 20mm size.
81 Providing and fixing 600mm x 450mm bevelled edge 8.00 Nos. 859.41
mirror of superior glass mounted on 6mm thick A.C. sheet
or plywood sheet and fixing to wooden pluge with C.P.
brass screws and washers.
82 Providing and fixing in position PVC cowel went to pipes 6.00 Nos. 75.75
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
83 Constructing brick masonry chamber for underground C.I. 7.00 Nos. 3660.76
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover
with frame (Light duty) 455mm x 610mm intenal
dimensions total weight of cover with frame to be not less
than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. )
(R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand
:4-graded stone aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement mortar 1:3
finished smooth with a floating coat of neat cement on
walls and bed concrete etc. complete.(ii) Inside dimensions
500mm x 700 mm and 450mm deep for pipe line with one
84 Providing and laying (to level or slopes) and jointing with 100.00 Rmt 531.09
stiff mixture of Cement Mortar in proportion 1:1 Salt
glazed stoneware pipes including testing of pipes and joints
complete and Providing and laying Cement concrete 1:5:10
(1-Cement : 5-Fine sand :10-Graded stone aggregate 40mm
nominal size) bedding for stoneware pipes of following
internal diameters with necessary formwork and curing
complete.(B) 150mm dia.
85 Providing sock pit of 5.00 Cu.M. Volume including 1.00 Nos. 3334.33
excavating and filling brickbats with dry masonry work at
top for 45cm. height including covering the top with stone
including providing vatas in C.M. 1:3 with finishing curing
etc. complete as directed.
86 Applying general insecticide pest control treatment to 852.00 Sqmt 80.85
floors, cupboards etc including labour materials etc.
complete. Using Imidacloprid 30.5 SCas Per IS 6313 part -
II( (0.075% concentration by mass) is recommended
10.5ml chemical diluted with 5 liters of water application
0.5 litre chemical /Sqm of surface is recommended as per
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
87 Anti-Termite System:Providing and laying of permanent 2837.00 Sqmt 134.33
piping technology anti-termite treatment before flooring
work by installing LLDP (Low linear density polyethylene)
tube of 8 mm O.D. & 6.4 mm 1.D. with inbuilt pressure
compensation chip every 30 cm interval in the tube, having
working pressure of 2 Kg/cm2 and release rate of
ltr/hour fixed by P-clips and nails. The LLDP pipe shall be
installed at the entire periphery of the building and at
internal network of building at a depth of 20 to 200 mm
under floor at every 2 to 3 mtr. c/c distance (adjusted as per
building layout ) & Ends of loop pass through a PVC elbow
of minimum 32 mm ID at junction box of wall and floor
level,entering into a steel reinforced grooved flexible pipe
of minimum 22 mm ID leading into junction box and the
loops shall terminate in junction boxes & test every
junction during injecting chemicals for termite control
treatment. The anti termite chemical Imidacloprid 30.5%
SC mix as per IS-6313 (part III) shall be injected by the
pressure pump diluted with water @ 10.5 ml/5 ltr of water
at the rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The contractor
shall submit approved line plan for piping system and
junction boxes dully approved by Engineer-in-Charge with
bond of 5 year warranty.(i)Anti Termite chemical injected
area (Chemical injecting incl. labour cost)
88 Providing and fixing Safety Grills of required pattern for 9444.80 Kg 108.38
windows/door using MS polished bars, Rectangular CRS
Pipes of size 50mm x 30mm x 2mm or Required at
required spacing as per design and hold fast with coach
bolts including one coat of and two coats of matt finished
oil painting etc. complete
89 Providing and fixing a set of wall mounted 38mm dia. U 2.00 Nos. 2323.00
shaped horizontal stainless steel collapsible grab bar,
38mm vertical stainless steel fixed grab rail of grade SS
304 from round pipe supported and 75mm dia 8mm thick
SS 304 base flange on wall including anchor fastners, nuts,
accessories as per detailed drawing etc. complete as
directed by architect or engineer in charge.
90 Providing and fixing 120 cm high Stainless Steel railing 39.00 Rmt 3586.41
made from anticorrosive 304 grade S.S. pipe of 50 mm dia.
(16 gauge) as hand rail with S.S.304 grade baluster of
mm dia (16 gauge) as a vertical support fixed in RCC Slab/
steps of stair at 1.2 mt. c/c including three horizontal S.S.
pipes of 16 mm dia (16 gauge) at equal distance fixed by
mm dia (16 gauge) S.S. pipe with baluster including
accessories as per detailed drawing as directwed etc.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
91 Providing & Fixing in position 300 to 150mm high 43.00 Nos. 757.50
English/Gujarati letters made from 1.0mm thick stainless
steel sheet as directed by the Engineer in charge with all
material, hardware, accessories and fittings etc. complete.
92 Providing and Fixing Tactile Layout Plan of size 900mm x 2.00 Nos. 38380.00
600mm as approved design, made of 3.0mm thick acrylic
non glare base plate and non glare cut out symbols with
Braille on which individual facility points, like inquiry,
reception, restrooms, medical room/ first aid, cafeteria or
breakout area, lounge, meeting room, conference room etc.
present the respective floors with pictograph wherever
needed all in tactile raised by minimum of 1.0mm to 2mm
in various colours to make it legible for seniors, partial
vision impaired etc. All the facility names should be in
Braille, along with English or Hindi. The entire block of
tactile signs should be mounted on wall for easy reading.
The maps to be installed at specified locations and installed
at a height of 800mm from ground level complete in all
respect as per Harmonized guideline & satisfaction of
Engineer in Charge.
93 Providing and Fixing of acrylic, non-glare, tactile audio 1.00 Nos. 50500.00
pictorial building layout as per the approved size, design
and make, having 3mm thick acrylic non glare base plate of
approved colour and non-glare cut out symbols raised 3mm
above base plate and Grade 2/ Grade 1 Braille to be integral
with the sign face and be raised 0.5mm above base plate.
The map to be installed at the specified location as per
accessibility standards, shall be oriented to the position of
the viewer and to be installed at the height of 800mm from
the finished ground/ floor level and using the necessary
hardware specified by the manufacturer and to be installed
complete as per design/specifications and guidelines as per
the entire satisfaction of the Engineer in Charge.
94 Providing and fixing braille dot and text Sign plate as per 2.00 Sqmt. 34239.00
standard ADA basis on wall / door made out of avg. 2mm
alluminum sheet/4mm ACP of Required size coated with
one coat of epoxy primer and two coat of best quality
epoxy paint reflectorised with High Itensity Primastic
Grade retro reflective sheeting. The details of symbols for
each board shall be as per the instruction, The fixing on
wall/ Door at site shall be done with necessary screw etc
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
95 Demolition of Brick work and stone masonry including 34.00 Cum 562.90
stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(ii) In Cement
96 Demolition including stacking of serviceable materilas and 5.00 Cum 1082.35
disposal of unserviceable materials with all lead and lift.
97 Dismentling barbed wire in fencing including making rolls 49.00 Rmt 68.15
and also including dismentling fencing posts including all
earth work concrete in base and making good the disturbed
ground stacking useful materials as directed and disposing
as directed and disposing of the unserviceable materials
with all lead and lift.
98 Brick work using common burnt clay building bricks 60.00 Cum 4214.33
having crushing strength not less than 35 kg./Sq.Cm. in
foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -
fine sand) (Conventional)
99 Providing and laying controlled cement concrete M.150 25.00 Cum 7316.44
and curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work for Coping
100 Providing & laying weep hole in Aburtments, and returns 421.00 Each 86.70
by using A.C. pipe of 100mm including laying in proper
grede and jointing the completed as per detailed
101 Provding and applying Exterior grade Exposed concrete 1067.00 Sqmt 869.41
texture finish (concrete design wall texture) of approved
make and shade over prepared surface, including surface
cleaning, primer application, base coat, texture coat
application to achieve exposed texture concrete panel
appearance with groove/joint pattern as shown in drawing,
curing, scaffolding, labour, materials, tools and all
incidental charges complete as directed by the Engineer-in-
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
102 Providing and fixing concertina coil fencing with punched 169.00 Rmt. 565.60
tape concertina coil 600 mm dia 10 mt openable length
having 50 no rounds per 6 mt length, upto 3mt height of
wall with existing angle iron (50mm x50mm x5mm
)requird shaped As per Directed Engeenier in charge.
placed 2.4mt or 3.00mt apart and with 4 horizontal R.B.T.
reinforced barbed wire(3 mm) , stud tied with G.I. staples
and G.I. clips to retain horizontal, including necessary bolts
or G.I.barbed wire tied to angle iron, all complete as per
direction of Engineer-in-charge, with reinforced barbed
tape (R.B.T.)/Spring core (2.5 mm thick) and weight
43.478 gm/meter at compound wall for ESR
103 Steel work, welded in built up sections framed work 266.00 Quintal 9108.49
including cutting, hoisting, fixing in position and applying
a priming coat of red lead paint. (A)In beams and joists,
channels angles Tees, flats, with connecting plates or angle
cleats as in main and cross beams. Hip and jack rafters,
purlins conneted to common rafters and the like
104 Painting two coats (excluding priming coat) on external 54.00 Sqmt. 22.56
surface of new rain water, soil, waste and vent pipes and
fittings with ready mixed bituminous brushing, black,
anticorrosive to give an even shade including cleaning of
all dirt, dust and other foreign matter. (B) 75mm dia.
105 Drilling of pilot bore hole of size 250/300 mm diameter at 350.00 Rmt 1544.29
above site by mud finish direct rotary rig etc. complete
106 Reaming of 250/300 mm diameter pilot bore hole to size 300.00 Rmt 742.35
450 mm diameter including assembling, lowering housing,
casing strainer pipes with gravel packing and clay ball
packing etc. complete.
107 Providing 600 CFM / 150 PSI capacity air compressor upto 1.00 Job 25118.70
available of sand free discharge ( Minimum 6.0 Hours)
108 Supply of reducer made frim 6 mm thick plate (M.S.) for 1.00 Nos. 2009.90
ERW pipe of size (ii) 200 mm dia. x 250 mm dia. X
109 Supply of 200 mm diameter V-wire screen pipe of slot size 105.00 Rmt 1401.88
1.0 mm nominal hole etc. complete.
110 Supply of M.S. Bore clamps with 3 holes on either side 1.00 Pair 1753.36
with nuts and bolts of standard make and suitable size (g)
750 mm x 75 mm x 16 mm flat to 200 mm dia. Pipe.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
111 Supply of Bore Plug having 100 mm height made from 1.00 Nos. 834.26
M.S. plate with 3 holes at equal distance on circumference
for nuts-bolts type, locking arrangement with nut-bolts &
lock nuts of standard make complete. (b) from 5 mm thick
M.S. plate (for top also) (ii) suitable for 200 mm dia. pipe.
112 Supply of M.S. Bail Plug having length of 0.45 mtr from 1.00 Nos. 907.99
medium class pipe as per I.S.S. suitable for (b) 200 mm
diameter pipe etc. complete.
113 Supply of Steel Bent plates suitable to ERW pipe for (b) 8.00 Nos. 71.71
200 mm diameter and 150 x 150 x 6 mm size etc.
114 Supply of Gravel of size selected size up to 4mm to 6 mm, 12.00 Cmt 2295.73
including stacking and filing etc. complete.
115 Charges for uptron make Electrologger (with carting ) of 1.00 Job 12120.00
pilot bore hole etc. complete.
116 Charges for Geo Hydrological ground water investigation 5.00 Job 16160.00
including water sample chemical analysis etc. complete.
117 S.I.T.C. submersible pump set suitable for bore of 150 mm 1.00 Each 49148.62
dia or more having 3 phase motor capacity not less than
HP with following capacity. Lifting and Lowering taken
extra. [C] 25 stage 160 to 100 LPM discharge at 185 to
mtr head for 50 mm dia delivery pipe
118 Providing and erecting PVC corrugated Flexible conduit 275.00 Rmt 26.26
with required numbers of coupling, PVC bushes, Check-
nuts etc. complete of following sizes. (3) 32 mm diameter
119 Lowering of submersible motor pump set complete with 1.00 Job 2568.43
required. Nos. and size of casing pipes erected by means of
proper chain pulley block & pipe wrenches after checking
of threads of each pipe with coupling to take the load of the
pump set and pipe assembly filled up with water. (B)
Above 60 mtr and up to 120 mtr
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
120 Supplying and erecting approved make motor control 1.00 Each 8710.24
cubical panel (Direct - on - line) made from 16 G. CRCA
sheet duly epoxy powder painted inside and outside with
hinged doors and locking, arrangement consisting of
suitable size of ON-OFF isolator (AC - 3/23 duty) main
fuses, single phasing preventer, indicating lamps for R-Y-B
phases, overload relay, automatic water level controller,
Ammeter, Voltmeter each with two way selector switch
incoming, wires duly socket crimped, main contactor &
overload relay, start-stop push buttons, to be erected on
angle iron frame grouted on wall as directed. The isolator,
overload relay & contactors will be of L&T, Seimens or
BCH make only (a) DOL upto 7.50 H.P.
121 Supplying and erecting XLPE (IS:7098) (I)-88 ISI 300.00 Rmt 136.35
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size. (E) 3 core 2.5 Sq. mm
122 Providing and fixing butterfly valve of IS approved brand 2.00 Nos. 1595.80
123 Providing 15mm thick cement mala plaster in single coat 177.00 Sqmt 240.42
on Rough (Similar)side of single or half brick walls for
interior plastering and finished even and smooth fininshing
with a floating coat of neat cement slurry in (i) Cement
mortar 1:3 (1-cement:3-sand), 10x10 mm groves etc.
Complete for upto Floor two level.
124 Providing and laying coloured glazed tiles of the size 300 84.00 Sqmt 1488.24
mm x 450 mm x 8 mm in skirting, risers of steps and dedo
on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse
sand) & jointed with white cement slurry.
125 Providing and laying polished Kota stone slab flooring over 6.00 Sqmt 1018.88
20mm (Average) thick base of cement mortar 1:6 (1-
cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 -
coarse sand) laid over and jointed with grey cement slurry
mixed with pigment to match the shade of slab including
rubbing and polishing etc. complete. (A) 25mm thick
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
126 Providing and fixing window having extruded aluminum 3.00 Sqmt 1583.96
Colour anodized section frame main outer size 95mm x
24mm x 1.17mm @ wt.of 0.738 Kg/mt , horizontal Three
track member size 92mm x 31.75mm x 1.30mm,@ Wt.1.07
Kg/mt , vertical member of size 92mm x 31.75mm x
1.50mm @ Wt. 1.06 Kg/mt with sliding shutters of
horizontal member size 40 mmx18mm x1.29mm @ wt.of
0.456 Kg/mt, vertical member of size 40mm x 18mm x
1.29 mm @ wt.of 0.456Kg/mt/ with 5 mm thick transparent
bronze colour tinted float glass with rubber gasket and
airlock strip anodiazed aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per
127 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. 3.00 Nos 958.17
size having weight not less than 35Kg.
128 Box cutting the road surface to proper slope and camber for 592.00 Cum 109.08
making a base for road work including removing the
excavated stuff and depositing on the road side slope as
directed upto 50Mt.lead.
129 Construction of B.I.T.C. granular sub base by providing 705.00 Cum 1933.49
granular material of Grading II, spreading in uniform layers
with motor grader on prepared surface , mixing by mix in
place method with front end loader at OMC , and
compacting with vibratory roller to achieve the desired
density ,complete as per Clause
130 Providing, laying, spreading and compacting stone 206.00 Cum 2380.70
aggregates of specific sizes to water bound macadam
(Grade-II) (B.T. Metal of size 45 to 63 mm) specification
including spreading in uniform thickness, hand packing,
rolling with 3 wheeled steel/ vibratory roller in stages to
proper grade and camber, applying and brooming requisite
type of screening/ binding Materials to fill up the interstices
of coarse aggregate, watering and compacting to the
required density.
131 Compaction and finishing of cement concrete road by 1066.00 Sqmt. 72.72
trimix process providing extra labour charges for the trimix
vaccum dewatering service process on cement concrete
road surface by using vaccum dewatering pump floater
surface vibrator including making rough finish to surface as
per in including levelling the complete.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
132 Supplying and fixing reinforced concrete heavy duty non- 100.00 Rmt. 660.00
pressure pipes with collars for culverts carrying heavy
traffic as per IS 458-1991 specifications including setting
the pipes in C.M. 1:2 watering and laying (to level or
slopes) of class NP3 of following internal daimeters.(i)
133 Construction of Cattle trap made from ISMC 100 border 8.00 Sqmt. 6146.86
and G.I. pipe 50 mm dia. Heavy duty at 12cm spacing by
welding and for supports 2 nos. I.S.M.C. 100x75x6 section
fixing in prepared chamber as per drawing.
134 Constructing Brick masonry road gully chamber 500mm x 32.00 Nos. 2017.20
450mm x 600mm including 500mm x 450mm C.I.
horizontal grating wih frame complete.
135 Providing and fixing pre-cast concrete kerb stone of gray 710.00 Rmt 402.55
cement based concrete block 30cm length,30cm height and
15cm thick of M200 grade concret as per approved design
and including excavation for fixing in proper line and
Level,filling the joint with C:M 1:3 (1cement:3fine sand)
136 Providing and fixing 1.20 Metre high fencing with 2.0 255.00 Rmt 391.94
Metre long M.S. Angle posts 40mm x 40 mm x6 mm and
oil painting 3 coats fixed at 2.5 Mt,C/c. with five
Horizontan lines and two diagonals of galvanised steel
barbed wire weighting 9.38 Kg. per 100 Metre, strained and
fixed to posts with G.I,staples including fixing the postsin
ground with 0.5 M x 0.5.M x 0.5 M. block in C.C 1:5:10
137 Supplying of yellow or Goradu soil with all lead and lift 362.00 Cum 1010.00
including spreading watering dressing and rolling with
hand roller etc complete selected soil
138 Supplying of well rotted FYM manure with all lead and lift 19.00 Cum 757.50
including spreading mixing dressing and rolling with hand
roller etc. complete
139 Scarifying the surface of soil including spreading of DAP 724.00 Sqmt. 52.52
fertilizer mixing with soil properly leveling ground
dressing of the plot
140 Supplying and planting Dibbling semi carpet lawn at 724.00 Sqmt. 181.80
distance of about 15 cm x 15 cm after proper anti termite
treatment and rolling the same by hand roller and watering
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
141 Bowling and developing flowering plants grown in nursery 100.00 Nos. 1010.00
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Arrica Palm
142 Bowling and developing flowering plants grown in nursery 100.00 Nos. 1313.00
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Triangle Palm
143 Bowling and developing flowering plants grown in nursery 50.00 Nos. 161.60
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Jasud
144 Bowling and developing flowering plants grown in nursery 50.00 Nos. 171.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Croton
145 Bowling and developing flowering plants grown in nursery 40.00 Nos. 171.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton
146 Bowling and developing flowering plants grown in nursery 50.00 Nos. 141.40
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton Petra
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
147 Bowling and developing flowering plants grown in nursery 20.00 Nos. 80.80
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton Petra Live Plant
148 Bowling and developing flowering plants grown in nursery 20.00 Nos. 202.00
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Golden Durenta Varigated
149 Bowling and developing flowering plants grown in nursery 20.00 Nos. 171.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Crotons Variety
150 Bowling and developing flowering plants grown in nursery 100.00 Nos. 70.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Green Mahindi
151 Bowling and developing flowering plants grown in nursery 30.00 Nos. 171.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Varigated Ficus
152 Bowling and developing flowering plants grown in nursery 40.00 Nos. 141.40
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted New Black Ficus
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
153 Bowling and developing flowering plants grown in nursery 40.00 Nos. 90.90
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted White Ribbon Plants
154 Bowling and developing flowering plants grown in nursery 200.00 Nos. 121.20
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Green Mahendi border
155 Bowling and developing flowering plants grown in nursery 20.00 Nos. 191.90
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Pendulla Asopalav
156 Bowling and developing flowering plants grown in nursery 50.00 Nos. 242.40
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Potted Plants
157 Labour charges for planting various plantsafler proper anti- 930.00 Nos. 141.40
termite treatment in pits including placing properly and
filling the pits with required prepared mix soil and watering
and dispporting etc. complete
158 Maintance of the garden for 60 days after Complition of 3 1.00 Job 25250.00
month stipulated period is completed for plantation of lawn
and plants including applying second round of proper anti-
termite treatment
159 Providing and fixing brass screw down stop cock (A) 15 10.00 Nos. 205.83
160 Rubber Hose Pipe 15 mm dia of approved brand and make 200.00 Rmt 90.90
161 Earthwork for embankment including breaking clods, 50.00 Cum 132.04
dressing with all lead and lift (including watering and
consolidation)(A) From Borrow pits within land width
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
162 Providing & Laying Rain Water Junction Chamber of Clear 6.00 Nos. 6197.36
Internal Size 0.60 x 0.60 x 0.75m with excavation of size
1.36 x 1.36m & 0.15m thick M200 Bed Concrete Including
brick masonary 0.23 thick wall in C.M. 1:6 of 0.75m height
with 15mm thick Cement Plaster inside & outside (1:4),
1.06 x 1.06 RCC M200 top slab of thickness 0.15m with
TMT steel and 455mm x 610mm cast iron manhole cover
with frame weight not less than 35 kg as per directed by
Engineer-in-charge.
163 Providing & Laying Filter chamber of brickwork 0.23 thick 6.00 Nos. 21814.99
in C.M. 1:6 of clear internal size 2.04m x 1.20m x 1.20m
and excavation dimension of 2.80m x 1.96m x 1.35m
including C.C. M200 Bed Concrete 0.15m thick and RCC
M200 Top slab of thickness 0.15m with TMT steel,
Including 15mm (1:4) thick cement plaster inside & outside
with Cement slurry & top cover with frame of minimum
weight of 35kg, including filling filter material of 200mm
thick each layer of 25-40mm, 10-20mm of BT metal and
sand as per directed by engineer-in-charge
164 Providing & Laying Water Harvesting Pit of clear size 2.00 1.00 Nos. 31772.58
mt x 2.00 mt x 4.00 mt. For water logging with excavation
in any strata upto four meter depth, Brick work 0.23 thick
in C.M. 1:6 of clear internal size 2.00m x 2.00m x 1.20m
with 15mm thick C.M. 1:4 plaster, filling the pit with B.T.
metal 40mm in 0.60 mt. depth with 25-40mm kaptchi,
mt. depth and 2mt. depth with coarse sand in layers
including makng P.V.C. line for water inlet etc. as directed
with 250mm dia bore 15mt. depth amd 150mm dia PVC
pipe of 10 Kg.f/cm2 casing wih gravel packing or as
165 Fire Pump panel (Combined for all Pumps) and electrical 1.00 Nos. 454500.00
works - starter panel with star delta or as per CFO
approved Starters rated to suite pump HP with necessary
protection features like SSP/ELR/OL/SC/ phase and on off
indicating lamps. The busbars shall be of AI - 0.8 A /
sqmm size. Panel shall be fabriated from 14G sheet steel
with svene tank process powder coated and shall be min IP
52. Panel shall have ammeter/Voltameter and KWh meter.
Cabling / Earthing from panel to pump shall be scope of
vendor without any extra cost. Cabling - supply / laying and
terminating the cables. Panel shall be rated min for 25KA
fault level. Cable trays - hot dip GI ladder type 16 gauge
with required supports shall be used for cabling. Panel shall
have one incomer MCCB/ACB of required rating where by
incoming supply and earthing shall be terminated by
electric colour.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
166 Fire Pumps & Accessories, Yard Hydrant, Internal Hydrant, 1.00 Nos. 153924.00
Hose Reel & Sprinkler System Supply, Installation, Testing
& Commisioning of Main Fire Pump Of Capacity 20 H.P.
with 55 mtr. Head, Pump
167 Supply, Installation, Testing & Commisioning of control 1.00 Nos. 90900.00
Panel suitable for automatic operation of fire fighting
pumps consisting (a) Necessary cabling, wiring, earthing
from panel to individual equipment shall be included in the
quoted price. (b) Facility for more selection i.e. auto or
manual. (c) Protection failure and control cabling. (d)
Interlocking of pressure switch with pumps.
168 Supply, Installation, Testing & Commisioning of 150mm 1.00 Nos. 3535.00
dia. Pressure Gauge of range 0 - 15 kg/cm3 confirming to
as per specification complete as required.
169 Supply, Installation, Testing & Commisioning of Pressure 1.00 Nos. 4545.00
Switches for automation of fire pumps, Pressure switches
shall be double pole, single throw type suitable for 3 phase
supply with diaphragm. Alluminium Enclosure with IP
protection as required.
170 Supply, Installation, Testing & Commisioning of the 125.00 meter 2390.67
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. a) 150 mm dia.
171 Supply, Installation, Testing & Commisioning of the 130.00 meter 1711.95
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. a) 100 mm dia.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
172 Supply, Installation, Testing & Commisioning of the 60.00 meter 1277.65
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. c) 80 mm dia.
173 Supply, Installation, Testing & Commisioning of the 125.00 meter 1100.90
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. d) 65 mm dia.
174 Supply, Installation, Testing & Commisioning of the 120.00 meter 989.80
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. e) 50 mm dia.
175 Supply, Installation, Testing & Commisioning of the 105.00 meter 858.50
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. f) 32 mm dia.
176 Supply, Installation, Testing & Commisioning of the 450.00 meter 555.50
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. g) 25 mm dia.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
177 Supply, Installation, Testing & Commisioning of C.I. 6.00 Nos. 9738.42
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required. a) 150 mm dia.
178 Supply, Installation, Testing & Commisioning of C.I. 8.00 Nos. 8932.44
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required. b) 100 mm dia.
179 Supply, Installation, Testing & Commisioning of C.I. 8.00 Nos. 5555.00
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required. d) 50 mm dia.
180 Supply, Installation, Testing & Commisioning of Cast iron 3.00 Nos. 9090.00
Dual plate Check valve (PN 1.6) a) 150 mm dia.
181 Supply, Installation, Testing & Commisioning of Cast iron 4.00 Nos. 7564.90
Dual plate Check valve (PN 1.6) b) 100 mm dia.
182 Supply, Installation, Testing & Commisioning S.S. Single 10.00 Nos. 5656.00
Headed Fire Hydrant Valve with 80mm N.B. Flanged inlet,
63 mm dia. Female instantaneous outlet type S.S. coupling,
blank cap, chain, twist release type lug & all accessories
Confirming to IS:5290. Including fixing with supports,
flanged tapping from wet riser, orifice plate.
183 Supply, Installation, Testing & Commisioning of Weather 10.00 Nos. 4595.50
proof standard M.S. Fire Hose Cabinet wall mounting type
(450mm x 450mm x 250mm deep) having single or double
opening with necessary locking arrangement by allan key
suitable for housing 1 nos. hose pipe, 1 nos. Branch pipe &
nozzle spanner.
184 Supply, Installation, Testing & Commisioning non 10.00 Nos. 5641.86
percolating rubber reinforced lined Fire Hose pipe (as per
IS:636) of 63mm dia and 15 mtr. Long. The hose shall be
rated for burst pressure pf 35.7kg/sqcm. Hose shall be
complete with ISI marked SS male & female coupling
(IS:903) bound & riveted to hose pipe with copper rivets &
1.5mm copper wire.
185 Supply, Installation, Testing & Commisioning of 63mm 3.00 Nos. 5641.86
dia. Instantaneous pattern SS 304, short branch pipe, 20mm
dia nozzle confirming to IS
186 Supply, Installation, Testing & Commisioning of First Aid 3.00 Nos. 6565.00
Hose Reel equipment conforming to 15:884 comprising of
hose reel drum, 8 mm shut off noz:z.le, Ru bber hose of
mm dia x 30 mtr. long, painting, swinging type fixing
bracket, anchor fastener, bolts & nuts etc.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
187 Supply, Installation, Testing & Commisioning of SS Ball 3.00 Nos. 858.50
Valve. A) 25mm dia.
188 Supply, Installation, Testing & Commisioning of Cast Iron 1.00 Nos. 8585.00
2 Way Fire Brigade Inlet as per 1S: 904 having 63 mm dia
in/et with blank cap and chain with necessary fit ti ngs,
flanges, nut bolts etc. complete as required. (For Hydrant
189 Supply, Installation, Testing & Commisioning of Gun 1.00 Nos. 959.50
Metal Air Release Valve with necessary fittings. Size:
25mm (For Riser)
190 Supply, Installation, Testing & Commisioning of Quartzoid 170.60 Nos. 454.50
Bulb type Sprinkler Heads. A) Pendent Sprinkler 57°C
191 Fire Alarm System Alarm panel Microprocessor based 8 3.00 Nos. 16665.00
192 Manual Call Point 2.00 Nos. 454.50
193 2 core x 1.5 sqmm wire with pvc conduct and required 400.00 Rmt. 166.65
194 Providing, Installation, testing and commissioning of 45.00 Nos. 3787.50
addressable smoke detectors, it shall support base mounted
isolator modules and the detectors shall have led for
indication and output for response indicator complete as
195 II) Fire Extinguisher and Exit Signages Supply, 6.00 Nos. 6447.84
installlation, testing and commissioning of Carbon Dioxide
(CO2) type Fire Extinguisher of 4.5 kg confirm to
IS:15683, with ISI marked / TAC approved fitted with
required accessories including wall suspension brakets.
196 Supply, Installation, Testing & Commisioning of ABC type 6.00 Nos. 2222.00
6kg confirm IS:15683, with ISI marked / TAC approved
fitted with required accessories including wall suspension
197 Providing AUTOGLOW Signages in block/ small letters of 1.00 Nos. 858.50
specified size (a) Fire Lift Size: 4" x 12"
198 Providing AUTOGLOW Signages in block/ small letters of 1.00 Nos. 858.50
specified size (b) Fire Hydrant : 4" x 12"
199 Providing AUTOGLOW Signages in block/ small letters of 2.00 Nos. 858.50
specified size (c) "DCP" Extingusher : 4" x 12"
200 Providing AUTOGLOW Signages in block/ small letters of 2.00 Nos. 858.50
specified size (c) "CO2" Extingusher : 4" x 12"
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
201 Providing, Installation, testing and commissioning of 3.00 Nos. 5504.50
addressable Looped power type manual break glass unit
with ressettable key
202 Providing, Installation, testing and commissioning of 2.00 Nos. 6565.00
addressable Looped power type Strobe combined hooters
203 Excavation for foundation upto 1.5 m depth including 27.00 Cum 212.53
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil (Excavated by Manual Labour)
204 Excavation for foundation for depth from 1.5 m to 3.0 m 9.00 Cum 235.05
including sorting out and stacking of useful materials
and disposing off the excavated stuff upto 50 Meter
lead.(A) Loose or soft soil (Excavated by Manual
205 (i) Half brick masonry in common brunt clay building 7.00 Sqmt. 629.84
bricks having crushing strength not less than 35 Kg/Sq.Cm.
in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in
foundation and plinth (B) Conventional
206 Providing and laying (to level or slopes) and jointing with 5.00 Rmt 317.39
stiff mixture of Cement Mortar in proportion 1:1 Salt
glazed stoneware pipes including testing of pipes and joints
complete.(B) 150mm dia.
207 Providing and Constructing sock pit of 3.46 mt. dia outside 1.00 Nos 109016.37
and 10 mt depth with honey combed masonary 9.50 mt.
from bottom and 0.60 mt. brick masonary in C.M. 1:6 top
with RCC slab cover of M200 vent pipe 1.8mt. Long
75mm dia & C.I. cover and cowel vent etc. comp
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
208 Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- 2.00 Nos 11042.75
cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse
sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement
:2-Coarse sand :4-stone aggregate 20mm nominal size)
finished smooth complete including curing and festing (i)
Inside size 900mm x 1200mm and 1.5M. deep including
C.I. cover with frame size 560mm diameter total weight of
cover and frame to be not less than 128 kgs. (Wt. of cover
64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick
walls of brick msonry using brick having crushing
strength not less than 35Kg. /sq.cm. in Cement Mortar
1:5 (1- Cement: 5-Coarse sand) (1) A type depth
Metre for 150mm diameter sewer.
209 Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- 2.00 Nos 19349.64
cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse
sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement
:2-Coarse sand :4-stone aggregate 20mm nominal size)
finished smooth complete including curing and festing (i)
Inside size 900mm x 1200mm and 1.5M. deep including
C.I. cover with frame size 560mm diameter total weight of
cover and frame to be not less than 128 kgs. (Wt. of cover
64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick
walls of brick msonry using brick having crushing
strength not less than 35Kg. /Sq.cm. in Cement Mortar
1:5 (1- Cement: 5-Coarse sand) (2) B type depth
Metre for 150mm diameter sewer.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
210 Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- 2.00 Nos 23470.49
cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse
sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement
:2-Coarse sand :4-stone aggregate 20mm nominal size)
finished smooth complete including curing and festing (i)
Inside size 900mm x 1200mm and 1.5M. deep including
C.I. cover with frame size 560mm diameter total weight of
cover and frame to be not less than 128 kgs. (Wt. of cover
64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick
walls of brick msonry using brick having crushing
strength not less than 35Kg. / sq.cm. in Cement Mortar
1:5 (1- Cement: 5-Coarse sand) (3) C type depth
Metre for 150mm diameter sewer.
211 Providing corrugated G.I. sheet of class-3 roofing fixed 244.00 Sqmt. 734.19
with glavanished iron J or L Hooks, Bolts and nuts 8mm
diameter with bitumen and G.I. limpet washer or G.I.
limpet washer. filled with white lead complete excluding
the cost of purlins, Rafters and Trusses.(1) 0.80 mm thick
212 Point wiring for Light / Bell with 2-1.5 sq.mm & earth 141.00 Pts. 582.77
wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires up to
10 mtr length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as
directed.(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete
Cat.III Make:- Honeywell, L&T, Crabtree, Indoasian, M.K,
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
213 Point wiring for Tissino / Modular secondary light point 20.00 Pt. 200.99
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both
are of ISI marked 1.1 kV grade FRLS PVC insulated multi
strand copper wires, in below type of pipe to be erected
complete with earth continuity and necessary connection
with primary light with accessories erected on Metal /
PVC / wooden box covered with 3 mm thick
PC(Polycarbonate) / Acrylic sheet for open / concealed
wiring. with necessary Lamp holder / ceiling rose /
H.D.Connector as directed.(f) with medium class Rigid
PVC pipe and accessories erected concealed in wall/ceiling
complete Make:- Honeywell, L&T, Crabtree, Indoasian,
214 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 52.00 Pts. 809.01
1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade
FRLS PVC insulated multi strand copper wires up to
mtr length, in below type of pipe erected with 6A Modular
type switch and hum free EME step type electronic fan
regulator mounted and accessories with earth continuity of
following type erected on PVC / Metallic/Wooden box,
single mounting base frame covered with
textured/metallic/white front plate modules erected on / in
wall / ceiling as per pipe erected. with necessary ceiling
rose / H.D.Connector as directed.(f) with medium class
Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. III Make:- Honeywell, L&T,
Crabtree, Indoasian, M.K, Anchor
215 Point wiring for on board Looped Plug with 6A Modular 50.00 Pts. 309.06
type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected
on / in wall / ceiling with following type accessories Cat.
III Make:- Honeywell, L&T, Crabtree, Indoasian, M.K,
216 Providing following type of Modular Type Accessories 9.00 Nos. 160.59
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured / metallic/white
front plate , modules erected with necessary connections as
per site situation directed by Engineer In charge. '(3) Two
Pin/RJ-11 Telephone Socket [A] For One Gang Cat.III
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
217 Providing following type of Modular Type Accessories 30.00 Nos. 25.25
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured / metallic/white
front plate , modules erected with necessary connections as
per site situation directed by Engineer In charge. '(7) Blank
Plate Single Cat.III Make:- Honeywell, L&T, Crabtree,
Indoasian, M.K, Anchor
218 Providing following type of Modular Type Accessories 36.00 Nos. 160.59
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured / metallic/white
front plate , modules erected with necessary connections as
per site situation directed by Engineer In charge. (8)
Computer RJ-45 socket Cat.III Make:- Honeywell, L&T,
Crabtree, Indoasian, M.K, Anchor
219 'Providing following type of Modular Type Accessories 20.00 Nos. 180.79
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured / metallic/white
front plate , modules erected with necessary connections as
per site situation directed by Engineer In charge. (9)
Amp. SP one way switch Cat.III Make:- Honeywell,
L&T, Crabtree, Indoasian, M.K, Anchor
220 Providing following type of Modular Type Accessories 20.00 Nos. 199.98
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured / metallic/white
front plate , modules erected with necessary connections as
per site situation directed by Engineer In charge. (10)
6/16Amp. Universal socket Cat.III Make:- Honeywell,
L&T, Crabtree, Indoasian, M.K, Anchor
221 Providing and erecting ISI mark Medium class RIGID PVC 60.00 Mtr. 24.24
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as directed
222 Providing and erecting ISI mark Medium class RIGID PVC 680.00 Mtr. 33.33
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as directed (b)
223 Providing & erecting PVC Corrugated Flexible Conduit 20.00 Mtr. 21.21
with required nos. of coupling, PVC bushes, Check-nuts
etc. complete of following sizes.(2) 25 mm
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
224 Supplying and laying UPVC cable trunking system 20.00 Mtr. 428.24
comprising unplasticised polyvinyl, chloride rigid material
with ignition free and flame proof confirming BS with
necessary end caps Internal and external bend, flat bends,
coupler, tee etc..All necessary accessories and measuring of
following sizes(2) 100 mm x 50 mm trunking
225 Supplying under floor pregalvanised corrosion proof 25.00 Mtr. 458.54
rectangular sheet steel cable trunking of 1.6 mm thick
having with stand point load up to 1.33 Ton & free from
seepage of concrete of screed water with all
accessories,Junction Box,Joints as required and demanded
by engineer-incharge and laying/erecting as per OEM
guidelines and as per instruction of engineer incharge
having following size of dimensions and No of
compartments (W x D x T) Cat-III [3] 100mm x 25mm x
1.6 mm with one compartment
226 Providing and erecting Mains with 1.1 KV grade FRLS 1030.00 Mtr. 104.03
PVC insulated ISI marked stranded Copper conductor wire
in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green colour for
earth continuity of following size(A) With medium class
Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
Make- RR Kabel, Havells, Avocab, KEI, Johnson, Polycab,
227 providing and erecting Mains with 1.1 KV grade FRLS 240.00 Mtr. 140.39
PVC insulated ISI marked stranded Copper conductor wire
in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (A) with medium class Rigid PVC pipe and
accessories (a) 2 wire 4 sq. mm Make- RR Kabel, Havells,
Avocab, KEI, Johnson, Polycab, ADCAB
228 providing and erecting Mains with 1.1 KV grade FRLS 30.00 Mtr. 184.83
PVC insulated ISI marked stranded Copper conductor wire
in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (A) with medium class Rigid PVC pipe and
accessories (b) 2 wire 6 sq. mm Make- RR Kabel, Havells,
Avocab, KEI, Johnson, Polycab, ADCAB
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
229 providing and erecting Mains with 1.1 KV grade FRLS 160.00 Mtr. 532.27
PVC insulated ISI marked stranded Copper conductor wire
in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (A) with medium class Rigid PVC pipe and
accessories (i) 4 wire 10 sq. mm (use earth wire of
sq.mm ) Make- RR Kabel, Havells, Avocab, KEI, Johnson,
230 providing and erecting Mains with ISI marked, 1.5KV 28.00 Mtr. 70.70
grade electrolyte multi stranded, annealed copper conductor
with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically
for control panel, relays, power switchgears, motor starters
& control wiring) with required size of copper lugs, nuts
and bolts if required. (e) One wire 6.00 sq. mm
231 'providing and erecting Mains with ISI marked, 1.5KV 28.00 Mtr. 115.14
grade electrolyte multi stranded, annealed copper conductor
with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically
for control panel, relays, power switchgears, motor starters
& control wiring) with required size of copper lugs, nuts
and bolts if required. (f) One wire 10.00 sq. mm
232 providing and erecting Mains with ISI marked, 1.5KV 13.00 Mtr. 177.76
grade electrolyte multi stranded, annealed copper conductor
with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically
for control panel, relays, power switchgears, motor starters
& control wiring) with required size of copper lugs, nuts
and bolts if required. '(g) One wire 16.00 sq. mm
233 'providing and erecting Mains with ISI marked, 1.5KV 13.00 Mtr. 295.93
grade electrolyte multi stranded, annealed copper conductor
with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically
for control panel, relays, power switchgears, motor starters
& control wiring) with required size of copper lugs, nuts
and bolts if required. (h) One wire 25.00 sq. mm
234 Supplying and erecting Flexible PVC insulated multi strand 78.00 Mtr. 58.58
multi core 1.1 kv grade ISI marked copper wires of
following size to be erected as directed. (e) 1.50 Sq.mm
core round PVC sheathed Make- RR Kabel, Havells,
Avocab, KEI, Johnson, Polycab, ADCAB
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
235 'Supplying and erecting Flexible PVC insulated multi 220.00 Mtr. 39.39
strand multi core 1.1 kv grade ISI marked copper wires of
following size to be erected as directed. (d) 1.50 Sq.mm
core round PVC sheathed Make- RR Kabel, Havells,
Avocab, KEI, Johnson, Polycab, ADCAB
236 Supplying & erecting approved make LAN cable of 1080.00 Mtr. 47.47
following size in existing pipe as per direction[C] CAT -
237 Supplying & erecting approved make Telephone Cable 180.00 Mtr. 20.20
electrolytic copper conductor PE insulation twisted in two
pairs, & wrapped with FRLS PVC tape & sheathed with
FRLS PVC or HFFR outer Jacket suitable for telephone
wiring & confirming to C-DOT erected in existing pipe. of
following size of conductors & nos.of pairs. With necessary
connections. '[A] Conductor Size 0.5 mm (a) Unarmoured
238 'Providing & erecting main Distribution (MDF) indoor 1.00 Nos. 994.85
type, back mounted frame as per DoT standard approved
with krone strips (a) Suitable for 10 pair
239 Providing & erecting Switch board for Computer or 36.00 Nos. 1133.22
electric apparatus consisting of following modular type
accessories mounted with PVC / Metallic concealed/open
box with single mounting base frame covered with
textured/metallic /white front plate,modules erected with
necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type
AccessoriesCat. III Make:- Honeywell, L&T, Crabtree,
Indoasian, M.K, Anchor
240 Decorative call bell Ting-tong box type 250 volts complete 10.00 Nos. 71.71
241 Supplying and erecting led lamps with following wattage 6.00 Nos. 69.69
capacity of 220 to 240 voltage, minimum 15000 burning
hours life, 500 V in built-surge protection,Polycarbonate
diffuser, mounting suitable for E14 / E27 / B22 lamp
holders, pf >= 0.5(A) LED Lamps integral type, with PC
diffuser suitable LAMP holder
(i) 2 to 3 watts Cat.III Make;- Jaquar, Wipro, LT,
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
242 Supplying and Erecting Motion Sensor Based LED Tube 95.00 Nos. 500.96
Light 4 Ft. with Following specifications : Input Voltage
Range :-160V to 270V AC, Power Factor ≥ 0.9, Power
Consumption :- 20W ± 5%, Frequency :- 50 ± 3 Hz, Color
Temerature :- 6500K ± 510K, Mode of Operation if No
Activity:- Dim/OFF Mode Mounting Type :- Wall /
SurfaceMounted with Clips, Sensing Range :- Upto 3-5
Mtr. Surge Protection :- Upto 2KV, Sensing Time to get
Full Brightness - Instant (Max 2 Sec.), Time to Get
Dim/OFF if No Activity - 15-30 Sec.
243 Supplying and erecting LED indoor fittings with LEDs of 16.00 Ea. 589.84
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion
resistance with diffuser housed in aluminium casted body
with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)(A) Square/
Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 kV Cat-lll Make;- Jaquar, Wipro,
LT, Havells, Luker
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
244 Supplying and erecting LED indoor fittings with LEDs of 24.00 Nos. 1794.77
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion
resistance with diffuser housed in aluminium casted body
with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (B) LED
Panel Light with provision for Plane front frame with
translucent cover fixed to housing complete.IP20(vi)
watts, 24" x 24", Surge- 2KV Cat.III Make;- Jaquar,
Wipro, LT, Havells, Luker
245 Supplying and erecting LED street light / Flood light 13.00 Nos. 5080.30
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)(A) Street Light (IP-
65), Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection. (iii) 60 -
89 watts Cat.III Make;- Jaquar, Wipro, LT, Havells, Luker
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
246 Supplying and erecting LED street light / Flood light 8.00 Nos. 6177.16
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) '(B) Flood Light (IP-
65), Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection. (iv) 90 -
119 watts Cat.III Make;- Jaquar, Wipro, LT, Havells,
247 Supplying and erecting LED street light / Flood light 2.00 Nos. 4096.56
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) (C) Post Top Lantern
LED fitting comprises of finish cast aluminum spigot and
spun aluminum canopy fixed with opal polycarbonate, pipe
arrangement for vertical mounting driver and accessories
wired up to terminal block.IP 65 (ii)32-40W Cat-lll Make;-
Jaquar, Wipro, LT, Havells, Luker
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
248 Approved make Four Pole LT Heavy Duty Switch 1.00 Nos. 8072.93
Disconnector Fuse Unit Cubical type for panel mounting
complete with operating mechanism suitable to operate on
415V A.C. With HRC fuses of suitable load confirming to
IS. 13947 (Part I & III). of following capacities (d)
200 Amp Cat.III Make- Indoasian, L&T, Schneider,ABB
249 Supplying & erecting approved make Four Pole 415V 1.00 Nos. 12241.20
change over switch interior for panel mounting with
operating mechanism A.C.23 duty confirming to IS
for(D)200A Cat.III Make- Indoasian, L&T, Schneider,ABB
250 Supplying & erecting approved make Four Pole 415V 1.00 Nos. 2611.86
change over switch interior for panel mounting with
operating mechanism A.C.23 duty confirming to IS for
(A)32-40A Cat.III For Motor Pump Panel Make-
Indoasian, L&T, Schneider,ABB
251 Providing and erecting Approved make Four pole moulded 3.00 Nos. 6790.23
case circuit breaker having breaking capacity ICU of
KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to
work on A.C. supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing
G.M.S. housing. ICS=100% of ICU only Cat III Make-
Indoasian, L&T, Schneider,ABB
252 Providing and erecting Approved make Four pole moulded 3.00 Nos. 8861.74
case circuit breaker having breaking capacity ICU of
KA. at 415 V. having normal current rating 125A. with
Fixed thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III Make-
Indoasian, L&T, Schneider,ABB
253 Providing and erecting Approved make Four pole moulded 3.00 Nos. 17843.67
case circuit breaker having breaking capacity ICU of
KA. at 415 V. having Normal current rating 200A.with
variable Thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing
G.M.S.housing ICS=100% of ICU only Cat III
Make- Indoasian, L&T, Schneider,ABB
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
254 Providing and erecting Approved make Four pole moulded 1.00 Nos. 23041.13
case circuit breaker having breaking capacity ICU of
KA. and above at 415 V . having normal current rating
250A. with variable thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing
G.M.S. housing.ICS=100% of ICU only Cat III
Make- Indoasian, L&T, Schneider,ABB
255 Supplying and erecting triple pole & neutral 440V / 500V 0.80 Rn.Mtr 1961.43
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (A) Suitable for 100 Amp. Capacity
256 Supplying and erecting triple pole & neutral 440V / 500V 1.80 Rn.Mtr 3202.71
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (B) Suitable for 200 Amp. capacity
257 providing and erecting Miniature circuit breaker single pole 23.00 Ea. 297.95
0.5A to 2A system and having breaking capacity 10 KA to
be erected in existing box. confirming to IS 8828/1996 with
ISI Mark Cat.III Make- Indoasian, L&T, Schneider,ABB
258 providing and erecting Miniature circuit breaker single pole 114.00 Nos. 123.22
6A to 25A suitable to operate on 240 V A.C. system and
having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark Cat.III
Make- Indoasian, L&T, Schneider,ABB
259 Providing & erecting 240 V MCB double pole switch for 8.00 Nos. 362.59
motor & inductive load (C Curve) having 10 KA
breaking capacity & confirms to IS : 8828 in existing box
having following capacity (B) 40 Amp. Cat.III Make-
Indoasian, L&T, Schneider,ABB
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
260 Providing & erecting 240 V MCB double pole switch for 2.00 Nos. 325.22
lighting Load (B Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following
capacity (B) 40 Amp. Cat.III Make- Indoasian, L&T,
261 Providing & erecting 415 V MCB Four Pole for Motor & 18.00 Nos. 736.29
Inductive Load (C Curve) having 10KA breaking capacity
& confirms to IS :8828 in existing box having following
capacity (b)40 Amp. Make- Indoasian, L&T,
262 Plastic enclosure fitted with DIN rail suitable for 8.00 Nos. 52.52
incorporating One / Two nos. MCB
263 Supplying KITKAT pattern porcelain cut-out fuse with 3.00 Nos. 420.16
base of following current capacity erected on existing block
board.(vi) 200 A. 500 V.
264 Providing and erecting Sheet Steel powder coated MCB 2.00 Nos. 1492.78
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of
same company of MCB to be used) suitable for(A) single
phase incoming and horizontal single phase outgoing (b)
sheet steel double door (IP-43) (iv)12 way Make-
Indoasian, L&T, Schneider,ABB
265 Providing and erecting Sheet Steel powder coated MCB 8.00 Nos. 2913.85
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of
same company of MCB to be used) suitable for (B) three
phase incoming and single phase horizontal type outgoing
Per phase isolation type (PPI)(b) sheet steel double
door(ii)6 way Make- Indoasian, L&T, Schneider,ABB
266 providing and erecting Approved make RCCBs conforming 26.00 Nos. 2458.34
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component. for
following Max. rating erected as directed (ii) 40Amps. DP
Cat. III Make- Indoasian, L&T, Schneider,ABB
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
267 Supplying & erecting approved make Electronics Starter 4.00 Nos. 975.66
and relay for air conditioners in ABS plastic moulded
housing. Company fabricated with bakelite terminal for
connection with silver coating bimetallic contact in
switching device for o/p with following features.
(1) Low Voltage Protection below 130 V
(2) High Voltage protection above 270 V
(3) Overload protection for 2-5, 4-10, 8-14, 10-16, 14-22
Amp. (inverse time chara-)
(4) Indicating LEDs for AC on LV, HV, O/L, T/D
(5) With unique feature of 3 minute of time delay
268 Providing and erecting metallic vitrified danger notice 3.00 Nos. 69.69
board as per language suggested by engineer incharge for
MEDIUM VOLTAGE installation to be erected as per IS-
269 Providing and erecting Annealed bare Copper wire 4.00 Kg. 794.87
270 Providing and erecting Pipe type earthing having 150 11.00 Nos. 368.65
cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
271 For using salt and charcoal / coke as required for pipe type 11.00 Nos. 171.70
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
272 Supplying & erecting earth pit of minimum bore 3.00 Nos. 4591.46
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for
following type of applications with chamber and heavy
duty cover. (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation
duly stamped and signed by agency and officer Incharge
has to ensure the value of earthing resistane mentioned in
test Certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must be
submitted by Agency. (a) For Electrical Installation up to
440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
273 Providing & erecting weather proof, dust & vermin proof, floor 4.00 Sq.Mtr 14902.55
mounted front operated indoor type cubical panel board
necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet for
outer body & doors, 16 SWG thick CRC M.S.sheet for internal
partitions with necessary accesories , supporting angles/ flats
channel including cutting, bending, drilling, welding, riveting
with internal partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of supplied
switch gears, BUSBARS, suitable size of inter connecting PVC
copper wire / copper-aluminium strips, rubber grommets, rib,
bakelite control fuses/MCB for measuring instruments, earth
bus & earth bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with locking
arrangement and rubber gasket,heavy duty end terminal
connection,danger notice board,necessary ventilation,earthing
strip complete. The Panel shall be painted with epoxy powder
coating. (The rates excludes the cost of switchgears, bus bars,
inter connecting mains & Copper Aluminium strips, meters,
Fuses etc. The dimension shall be measured excluding base
beams) The panel shall be supplied with following approved
manufacturers with following size. (B) The standard companies
switch gear shall be used and only manufacturers at CPRI
approved factory (i) with 350 mm depth
274 Providing , erecting , fabricating the M.S. structure as per 120.00 Kgs. 77.77
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing duly
painted with one coat of red oxide with erection on site as
per direction of engineer in charge with necessary grouting,
cementing, plastering & finishing complete.
275 Providing and erecting FRLS XLPE(IS:7098)(I)-88 ISI 15.00 Mtr. 454.50
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (D) 3 1/2 core
70 Sq. mm ( 35 Sq. mm 1/2 core) Make- RR Kabel,
Havells, Avocab, KEI, Johnson, Polycab,ADCAB
276 Providing and erecting FRLS XLPE(IS:7098)(I)-88 ISI 80.00 Mtr. 589.84
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (E) 3 1/2 core
95 Sq. mm ( 50 Sq. mm 1/2 core) Make- RR Kabel,
Havells, Avocab, KEI, Johnson, Polycab,ADCAB
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
277 Providing and erecting FRLS XLPE (IS:7098)(I)-88 ISI 380.00 Mtr. 151.50
armoured cable multistrand / Solid Aluminium conductor
for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables(B) 4 core
6 Sq. mm Make- RR Kabel, Havells, Avocab, KEI,
Johnson, Polycab,ADCAB
278 Making trench in soft soil of suitable width of 90 cm deep 240.00 Mtr. 55.55
for laying cable or locating the fault all over the run and
back filling the same and making the surface as normal
279 Drilling the road without breaking the road surface 10.00 Mtr. 492.88
(Asphalt) for laying of cable for feeding power supply by
making up to following size of holes at both ends
complete.(A) Up to 100 mm bore dia
280 Providing & laying approved make Double walled 220.00 Mtr. 62.62
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable
(A)50 mm outer dia
281 Providing & laying approved make Double walled 40.00 Mtr. 95.95
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable
(C))90 mm outer dia
282 Providing and, fixing heavy duty flange type brass cable 38.00 Nos. 38.38
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.(B) 2 to 4 core 6 Sq. mm
283 Providing and, fixing heavy duty flange type brass double 2.00 Nos. 103.02
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (C) 3 & 1/2
284 Providing and, fixing heavy duty flange type brass double 24.00 Nos. 131.30
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (D) 3 & 1/2
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
285 Solder less crimping type Aluminium lugs conforming to 152.00 Nos. 6.06
IS suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner. (A) 1.5/ 2.5/4/6 Sq.mm
286 Solder less crimping type Aluminium lugs conforming to 2.00 Nos. 20.20
IS suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner. (D) 35/50 Sq.mm.
287 Solder less crimping type Aluminium lugs conforming to 10.00 Nos. 25.25
IS suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner. (E) 70 Sq.mm.
288 Solder less crimping type Aluminium lugs conforming to 12.00 Nos. 40.40
IS suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner. (F) 95 Sq.mm.
289 Supply, Installation, Testing and Commissioning of 52.00 Nos. 2885.57
suitable sweep, BEE 5 Star rated, Ceiling fan with Brush
Less Direct Current (BLDC) permanent ferrite magnet
Motor, class of insulation: B, Rust free 3 nos.Aluminium
blades, 2 nos. canopies, shackle kit with earthing provision,
copper winding, Power factor not < 0.9, Service Value
(CMM/W) minimum 6.85, Air delivery minimum
CMM, 350 RPM,230v (tolerance as per IS : 374-2019),
THD < 10%, with remote unit for Speed Control and all
remaining accessories including safety pin, nut bolts,
washers, temperature rise = 75 °C (Max.), suitable for
to 285 Voltage and rectifier circuit with surge, over current
and overload protection , 50 Hz, Single phase AC Supply,
earthing etc. Complete as required.[ Make shall be
approved by Engineer in Charge] (B) 1200 mm Sweep
(48") Make:- USHA, CROMPTON, HAVELLS, ORIENT
290 Supplying and erecting 19 / 20 mm. nominal bore Medium 52.00 Mtr. 108.07
Class M.S. Pipe down rod erected duly painted for fan
complete with proper insulation without leakage and
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
291 Supplying & erecting fan hook box of 10 mm M.S. round 52.00 Nos. 108.07
bar bounded to the RCC bars up to 50mm length each side
and pierced through a 16 Gauge M.S. box / Heavy Duty
PVC box complete erected concealed in Ceiling with
necessary finishing.
292 Providing 2.5mm.thick laminated acrylic sheet to cover the 52.00 Nos. 18.18
fan hook or Fan box.
293 Supplying & erecting approved make low noise decorative 10.00 Nos. 1366.53
exhaust fan having square frame ABS body with inbuilt
lowers & square frame200mm with 1350 RPM Cat.II
Make:- USHA,CROMPTON, HAVELLS, ORIENT
294 Supplying and erecting approved make Octagonal pole 11.00 Nos. 7561.87
made from HR sheet steel. The pole should be made as per
IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
MCB Mounting, stud type terminal and arrangement for
cable termination to be erected With Suitable foundation
(Included) as per details given by manufacturer considering
site requirement.(C) 5 Mtr. Long 70 mm Top X 130 mm
bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M16 Bolts and 600mm long with necessary
G.I. J Bolts .Approx Pole weight 46 kg
295 Supplying & erecting approved make SMC press moulded 10.00 Nos. 515.10
composite FRP. loop-in, loop-out approx. 2mm thick box
complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements with
mounting clamp with nuts, bolts & washers suitable for
erection on pole with cable clamps& earth bolt of following
size of box.(B) 250mm x 200mm x 100mm [deep]
296 Supplying and erecting Street light pole bracket comprising 9.00 Nos. 491.87
main B Class GI pipe of 4.2 cm/require outside dia.
complete with suitable B Class G.I. sleeve tubing of
approx. 45cms.length and suitable for
76.5mm/80mm/require size of pole top having nuts and
bolts for fixing the brackets and having spread of 0.5 mtr.
Length with 110 deg.with vertical plane and suitable
welded stiffener reducer and nipple with check nut
complete painted with one coat.of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint with
following nos of arms.[A] Single Arm bracket 0.5 Mtr
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
297 Supplying and erecting Street light pole bracket comprising 2.00 Nos. 622.16
main B Class GI pipe of 4.2 cm/require outside dia.
complete with suitable B Class G.I. sleeve tubing of
approx. 45cms.length and suitable for
76.5mm/80mm/require size of pole top having nuts and
bolts for fixing the brackets and having spread of 0.5 mtr.
Length with 110 deg.with vertical plane and suitable
welded stiffener reducer and nipple with check nut
complete painted with one coat.of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint with
following nos of arms. [B] Double Arm Bracket 0.5 Mtr
298 Supplying & erecting approved make Digital time switch 2.00 Nos. 3168.37
having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum &
LCD display. Also comprised permanent ON/OFF
switching. Programming switches & housed in fire proof
thermoplastic enclosure & transparent cover erected as
required with necessary connection erected as directed.
299 Supplying & erecting power contactor ,AC3 duty for time 2.00 Nos. 2782.55
switch complete erected as per direction Cat III (D) 4 pole
300 Providing & erecting, programming, testing of chairman 4.00 Ea. 7191.20
unit microphone with flexible stem of 480 mm in length
and light ring built in loud speaker ,two head phone socket
,attractive design ,priority button for chairman
microphone,built in volume control for head phones,chime
tone facility to precede chairman priority calls,microphone
on/off button,red indicates for microphone is
active,frequency response -400Hz to 10kHz,nominal
acoustic input -85 dB SPL [[Approved by Competent
Authority i.e. not Below the rank of Executive Engineer ]
301 Providing & erecting, programming, testing of Delegate 28.00 Ea. 6678.12
unit microphone with flexible stem of 480 mm in length
and light ring built in loud speaker ,two head phone socket
,attractive design ,built in volume control for head
phones,chime tone facility to precede chairman priority
calls,microphone on/off button,red indicates for
microphone is active,frequency response -400Hz to
10kHz,nominal acoustic input -85 dB SPL [[Approved by
Competent Authority i.e. not Below the rank of Executive
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
302 Supplying and erecting ceiling speaker with rated power of 16.00 Ea. 3083.53
30 watt/power tapping 30/15/7.5 watt available,opening
angle 180 degree H * 77 degree V ,sound pressure level
dB ,frequency response of 70Hz to 20KHz [[Approved by
Competent Authority i.e. not Below the rank of Executive
303 Supplying & erecting Amplifier having following 2.00 Ea 13558.24
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db
Tone Controls :Cut & Boost type
LED Meter :5 LED Arrays
The amplifier suitable to operate 240V A.C.& 24volt D.C.
(Battery) with automatic changeover from AC to Battery
operation, duly protected by wrong Battery Polarity
connections. [[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
304 Supplying & erecting Mixing Console having channels, Audio mixer 2.00 Ea. 22063.45
with. Echo facility for live performance, Auditorium & stadiums,
having following features & facilities. [[Approved by Competent
Authority i.e. not Below the rank of Executive Engineer ] (a)input
Channels :- Each channel has separate 6.25mm size balanced phone
jack for mike & line for balanced & unbalanced signals.
(b)Individual gain control for sating optimum level for minimum
noise. (c)BASS, MID & TREBLE ‘ controls Separately for each input
channel. (d)ECHO control for each channel (e)PAN control for echo
channel for left or right output (f) AUX Control : To control , level of
the channel in final mix to AUX sound output (g)Channel ON/OFF
switch (h)ECHO Section :- ECHO, reverb & Chorus effect can be
added to all input channel by different setting of Delay, Reverb & Level
control. (i)Tape section (j)Aux. send & return For sending Pre-feeder
output of channel for monitoring or adding a special effect unit.
(k)Mono / Stereo output controls (L)Master faders to control over left
& right output (m) Head phone output for monitoring purpose.
Technical specification (a)Power Requirement -AC220-24OV 50 Hz
DC 24 Volts (b)MIC Output Impedance/gain -2 K Ohms/ 62 dB
(c)Line Output Balance/42 dB —- 20 K ohms (d) Impedance /
Gain :- 10Kohms unbalance / 42 dB (e)frequency Response -
Hz- 20 KHz L / R Line Output ( + 0, -1 dB ) (f)Equalization
Bass/ - + / - 12 dB at 100Hz Mid / Treble 2 KHz / 10 KHz
(g) Outputs, Line Output Line Output Low : -10 dB / -2 dBM
Line Output High : 0 dBM / +17 dBM (775 mv / 5.5 V ) (h) S/N
ratio Line Output Level : > 70 dB (0 dB, 0.775V) The Console shall
be mounted on standard Rack, The channel of following numbers.(A)
14 Channel Audio Mixer with ECHO
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
305 SITC of 3LCD Lamp based projector having wxga 1.00 Ea. 33895.60
(1280x800) or better resolution with minimum white
brightness of 3800 lumens and color brightness of
lumens. The projector should have minimum
1HDMI,1VGA input. Having contrast ratio of 15000:1 or
more. the projector should have auto vertical key stone
correction of +/- 30 degree and Manual Horizontal of +/-30
degree. the projector should have optical lens, throw ratio
1.30-1.56:1. Zoom Factor of 1.2. Lens focus Manual
having focal length 16.9mm to 20.28mm. projector should
have features like AV mute slide, quick corner and split
function and should support wireless functionality with
inbuilt wifi or wifi dongle. [Approved by Competent
Authority i.e. not Below the rank of Executive Engineer ]
306 SITC of universal Projector mounting kit, with necessary 1.00 Ea. 6848.81
grouting, fasteners etc. with adjustable height and suitable
for all types of projectors. [Approved by Competent
Authority i.e. not Below the rank of Executive Engineer ]
307 SITC of 120 inch Self Lock MW (8 x 6) Instalock Slow 1.00 Ea. 5334.82
Retraction Screen, Aspect Ratio-4:3
[Approved by Competent Authority i.e. not Below the rank
of Executive Engineer ]
308 Providing and erecting Inverter based approved make split 4.00 Nos. 45898.44
air-conditioning unit consisting of condensing unit with
variable speed fan motor, inverter type hermetically sealed
rotary compressor with accessories etc. duly connected
separately erected evaporating unit and blower motor with
its accessories by means of extra supplied proper insulated
copper tubing,drain PVC pipes suitable for ( cost includes
Eco Friendly green gas charging and 15A plug top &
Remote Control & MS Stand) with necessary core cutting.
(1)For ISEER Range (KWH/KWH)(3.1 to 3.99) (B) for
ton capacity Make;- Bluestar, Daikin, Carrier
309 Supplying and erecting insulated pair of soft copper tubing 24.00 Rmt. 1158.47
open or concealed including power and control
cable,necessary PVC drain pipes for Split/Cassette AC
machine up to 4 TR capacity
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
310 Providing & erecting water cooler having storage capacity 2.00 Nos. 61482.74
150 Ltr. & cooling capacity 150 Ltr.per hour @ an ambient
temp of 45˚ C. The outlet temp. of the water should drop by
15˚C within a hour, The water cooler should be comprising
of hermetically sealed compressor, fan motor, condensing
unit, water tank surrounded by evaporating, coil,
thermostats, relay etc.complete with necessary inlet &
outlet connection. The body of water cooler will be made
from Stainless Steel and ISI Certified.Make- VOLTAS,
311 Supplying & erecting reverse osmosis (RO) water 2.00 Nos. 77891.20
purification system with M.S. powder coated pedestal
frame, prefilter housing carbon filter suitable buster DC
pump, auto low & high pressure switches with following
size of LPH capacity & erected as directed [D] 100 LPH
with 1 phase / 3 phase Raw water pump of 500LPH @
2.5kg/cm2 - (1N0 - Kirloskar /CRI/Lubi), Dual media filter
10"x54" - (1 No), Micron cartridge filter 20" x 2.5" ( 1No),
High pressure pump 500LPH @ 10kg/cm2 - (1No - Shimge
/CRI /Lubi), RO Membrane housing with RO membrane
of 40*40 - (1No), RO pressure tube 4" x 1E - ( 1No), 0 -
1200LPH Rotameter -(2 Nos), with Recovery Rate 50%.
312 Supplying and erecting approved make panel mounting 3.00 Nos. 1275.63
type Digital Voltmeter having 3 digits LED display, 0 to
750 AC Volts range erected on existing panel board with
all connection, wiring etc .with manufacturers calibration
313 Supplying and erecting approved make panel mounting 3.00 Nos. 1558.43
type Digital Ammeter having 3 digits LED display,
external CT operated, calibrated for 0 to 1000 Amps
suitable to operate on 500 Volt AC , erected on existing
panel board with all connection, wiring etc .with
manufacturers calibration certificate.
314 Supplying and erecting Ammeter / Voltmeter selector 6.00 Nos. 317.14
switch for 3 phase AC Supply 500 V on existing panel
board with necessary connections.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
315 Providing & erecting L.T. Current Transformer with bar 9.00 Nos. 274.72
primary 50/5 to 1000/5 ratio 15 VA burden erected in
existing CRCA box duly secured with insulating materials
connected to the meter
316 Supplying and erecting approved make suitable panel 9.00 Nos. 43.43
indicator LED type lamp, lens cover, complete erected with
necessary connections.
317 Providing & erecting open well horizontal mono block 2.00 Nos. 17279.08
pump set with cast iron body, complete for three phase
submersible motor having [C] For 3 HP 3 phase open well
horizontal mono block pump set suitable for 85 LPM to
270 LPM @ 11 mtr to 33 mtr head suitable for 50/65 mm
dia delivery pipe Cat.II Make:- PRIMA, AMRUT,
DUKE, LUBI. CROMPTON
318 Supplying & erecting approved make motor control 2.00 Nos. 7250.79
cubical panel [Star delta] made from 16G CRCA sheet duly
epoxy powder painted inside and outside with hinged doors
and locking with suitable size of ON - OFF isolator (AC 3 /
23 duty) main fuses. Digital volt and current meter (in a
single unit) with micro controller based control unit and
current sensing single phasing preventer electronic
overload protection, over voltage (Programmable)
protection and under voltage (Programmable) protection,
prod less dry run protection programming facility for
setting of all parameter like overload current, high voltage
limit, low voltage limit, dry run limit with digital indication
on seven segment LED display for any fault like over load,
high voltage, low voltage, dry running single crimped,
electronic star delta timer, feather touch start / stop push
buttons to be erected on angle iron frame. Grouted on wall
the contactors will be of L& T, Siemens, BCH make
only)(A) DOL up to 5.0 H.P.
319 Lowering of submersible motor pump set at the depth of 2.00 Job 856.48
following ,complete with required. Nos. and size of casing
pipes erected by means of proper chain pulley block & pipe
wrenches after checking of threads of each pipe with
coupling to take the load of the pump set and pipe assembly
filled up with water (d)For Open well Horizontal
submersible pump set for sump well (i) 1 HP to
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
320 Providing and erecting ISI marked PVC insulated PVC 40.00 Mtr. 104.03
Sheathed Flat flexible Submersible copper cable approved
make of following Size. (B) 3 Core x 2.5 Sq. mm. Make-
RR Kabel, Havells, Avocab, KEI, Johnson,
321 Providing Water proof straight Joint in PVC insulated flat 2.00 Nos. 189.88
flexible copper cable by using insulating material, water
proofing material, & making the joint complete. (A) Up to
322 SITC of 55 inch Smart LED TV Android/Webcam/ 1.00 Nos. 56870.00
Resolution: 4K Ultra HD (3840 x 2160) | Refresh Rate:
Connectivity: 3 HDMI ports to connect set top box,
console | 2 USB ports to connect hard drives and other
Sound : 20 Watts Output | 2ch |Open Baffle Speaker |
Dolby Audio |2 Full Range (44.5 x 106mm)
Smart TV Features: Google TV | Watchlist | Google
Assistant | Chromecast Built In ALLM/eARC (HDMI
Display : 4K LED | 4K Processor X1 | Live Color | 4K X-
Reality PRO | MotionFlow XR 100 | HDR10/HLG
323 Supplying and Erecting Micro Controlled Based 3 - PH 1.00 NOS 247450.00
Servo 100KVA Voltage Stabilizer with Following
Specifications Input Voltage :- 350 to 480V (Three Phase)
Output Voltage :- 415V ± 1% (Three Phase), Overload
Capacity :- 120%, Correction Speed :- 35V/Sec, Input
Frequency Range :- 47 to 53 Hz, Response Time :-
Instantaneous (mili sec.) Corrected Speed :- 10-60V/Sec
(As Required), Correction Method :- Step Less Correction,
Cooling :- Oil Cooled, Duty Cycle :- 24Hrs, Mode of
System :- Auto, Effieciency :- 97 to 99%, Winding
Dimmer/Buckboost :-Cu/Cu, Suitable for 100%
Unbalanced/ Balanced Supply Loads, High Voltage Cutoff,
Low Voltage Cutoff, Single Phase Preventation Phase
Failed Cutoff, Overload Cutoff, Short Circuit Protection
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
324 Supplying and fixing of following size Wall mount Rack 2.00 Nos 11421.08
having fixed Structure with 0.8mm CRCA Sheet,
completely knocked-down condition (CKD) Shape,
Verticle Mounting Rail 1.6 mm with 'U' Marking,
Minimum 2 cable entry/exit provision at Top and bottom
with rubber protection,Front 5 mm Toughened Glass with
lock, wall mounting kit, powder coated color-RAL-
7035,complied with UL & RoHS, 2*6 Sockets 16A powder
distribution units, 3 numbers closed cable organizer,
Hardware mounting screws packet of 20*1 number, etc.
Complete as required. (B) 15 U Rack
325 SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port- 2.00 Nos 4400.57
Fully Loaded [Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
326 SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 48.00 Nos 200.99
30U' Snag less [Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
327 SITC of 24 x 10/100/1000BASE-T ports 2.00 Nos 15399.47
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
L2+ Static Routing
Optional “standard mode” or “surveillance mode”
management user interface [Approved by Competent
Authority i.e. not Below the rank of Executive Engineer ]
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
328 Supplying, Erecting, Testing & Commissioning the 1.00 Ea. 1361332.54
passenger / stretcher lift having following main
features:(A) GENERAL DESCRIPTION OF LIFTS.[1]
GEAR LESS LIFT DRIVE (MRL) comprising of High
Starting torque Lift 3 phase 440 V A. C. Permanent Magnet
Synchronous motor of proper rating with high efficiency
shall be used.[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback closed loop
system shall be used for lift car and door operation which
shall be full collective selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/ Down
Contactor with overload and phase reversal relay and safety
controls. [3] Car with M S platform with bracings of
adequate size and to sustain the impact load cabin +
passenger with safety factor of fire for steel and side panels
of Stainless steel of sheet of grade 304 duty. Car ceiling
will be S.S. finishes with aesthetic appearance with LED
ceiling lights. Car flooring shall be of s/s 304 chaker plate
design suggested of engineer in charge. of engineer in
charge. Car doors shall be of stainless steel grade
hairline finish with centre opening / telescopic automatic
doors. Car panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel buttons and
all floor switches must be with brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour shall be
fully automatic centre opening/ telescopic opening made of
hairline finish steel grade of 304 with key holes and
infrared curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car
along with alarm switch shall be provided. Also,
Emergency Light & Fan should start immediately without
any Time Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow
along with floor position indicator shall be provided inside
the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
of Stainless steel of sheet of grade 304 duty. Car ceiling
will be S.S. finishes with aesthetic appearance with LED Estimated
Rates Total Amount
Rates Total Amount
Item ceiling lights. Car flooring shall be of s/s 304 chaker plate according
Item of work Quantity Unit
No. design suggested of engineer in charge. of engineer in In figure to estimated
charge. Car doors shall be of stainless steel grade 304, Rs. Ps.
1 hairline finish with centre opening
2 / telescopic automatic 3 4 5
doors. Car panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel buttons and
all floor switches must be with brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour shall be
fully automatic centre opening/ telescopic opening made of
hairline finish steel grade of 304 with key holes and
infrared curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car
along with alarm switch shall be provided. Also,
Emergency Light & Fan should start immediately without
any Time Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow
along with floor position indicator shall be provided inside
the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual Rescue
Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed. [10] Spring buffers/PU Buffers
shall be provided.
[11] Car fan as per passenger capacity with automatic sleep
timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and submission of
calibration certificate submission, door key holes in the
floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine
room and monkey ladder for lift pit should be provided by
the lift agency, along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided. Estimated
Rates Total Amount
Rates Total Amount
[8] Automatic Rescue Device (ARD) shall be provided
Item of work Quantity Unit
No. accordingly of passenger capacity with Manual Rescue In figure to estimated
Operation ( Manual Cranking Facility). Rs. Ps.
1 [9] Audio visual indication 2in the lift car showing over 3 4 5
loading shall be provided such that doors kept open till
excess load is removed. [10] Spring buffers/PU Buffers
shall be provided.
[11] Car fan as per passenger capacity with automatic sleep
timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and submission of
calibration certificate submission, door key holes in the
floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine
room and monkey ladder for lift pit should be provided by
the lift agency, along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without
any extra cost, where ever required as / if directed by
engineer in charge. [17] Permanent wiring with necessary
safety devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator in circuit
for lift machine room and lift well with proper numbers of
light points, with fixtures, exhaust fan and plug points shall
be provided by the agency. Only 3 phase Power Supply
shall be made available by department in lift machine
room. Necessary Earthing as per Lift Act/Rules shall be
arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration
in lift shaft and machine room related to erection of lift
shall be made by lift agency without any extra cost.
(granite/marble fixing around all landing door openings are
not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all necessary
permission from lift inspector and other authorities.
[20] acrylic transparent licence/display A4 size holder in
lift car [20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has to provide
the lift agency, along with the other steel structure works,
foundations for the machine etc… Estimated
[16] In the hoist way fascia plate shall be provided without Rates Total Amount
[16] In the hoist way fascia plate shall be provided without Rates Total Amount
Item of work Quantity Unit
No. any extra cost, where ever required as / if directed by In figure to estimated
engineer in charge. [17] Permanent wiring with necessary quantities
safety devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator in circuit
for lift machine room and lift well with proper numbers of
light points, with fixtures, exhaust fan and plug points shall
be provided by the agency. Only 3 phase Power Supply
shall be made available by department in lift machine
room. Necessary Earthing as per Lift Act/Rules shall be
arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration
in lift shaft and machine room related to erection of lift
shall be made by lift agency without any extra cost.
(granite/marble fixing around all landing door openings are
not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all necessary
permission from lift inspector and other authorities.
[20] acrylic transparent licence/display A4 size holder in
lift car [20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift
erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide third
party insurance up to completion of free maintenance
period and submit the document for the same.[21] Car
Panel Operating Buttons at an accessible height from
wheelchair for handicapped person and raised numbers
with brail mark with floor position indicator/buttons must
be of Auto Glow type clearly visible when view from
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should be
provided at appropriate 900mm height on the Rear & Side
Wall Panels in Lift Car. [23] With Necessary kVA rating
voltage controlled Stabilizer suitable for your controller,
drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for
lift is in scope of work which rating is sugested by
[20] acrylic transparent licence/display A4 size holder in
lift car [20A] As per statutory requirement of Govt. Of Estimated
Rates Total Amount
Rates Total Amount
Item Gujarat lift & escalator act 2000, lift agency has to provide according
Item of work Quantity Unit
No. 1. Car top safety barricade In figure to estimated
2. Push & talk communication system. Rs. Ps.
1 3. Fireman's switch
2 at Ground Floor. 3 4 5
4.carrying out third party lift inspection during/after lift
erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide third
party insurance up to completion of free maintenance
period and submit the document for the same.[21] Car
Panel Operating Buttons at an accessible height from
wheelchair for handicapped person and raised numbers
with brail mark with floor position indicator/buttons must
be of Auto Glow type clearly visible when view from
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should be
provided at appropriate 900mm height on the Rear & Side
Wall Panels in Lift Car. [23] With Necessary kVA rating
voltage controlled Stabilizer suitable for your controller,
drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for
lift is in scope of work which rating is sugested by
CEICED Department (electrical Inspector) (B) SPECIAL
FEATURES DESCRIPTION OF LIFTS for PREMIUM
category 1. Advanced control system dual 64 bit embedded
microprocessor with CANBUS Serial Communication
mode including Regenerative powe efficient operation,on
site programming facility, Anti nuisance, Pte-opening,
BMS/RMS with necessary online real time monitoring
system having necessary connectivity for remote
monitoring & other suitable supporting hardware &
software devices to fulfil the purpose.2. Floor Indication
LCD Display with call registration & brail mark with
arrival gong and hall lantern & TFT Screen in the car with
MP3 Voice Announcer. 3. CAR Panel should be Scratch
resistive SS Moonrock finish / Hair Line / Honeycomb for
car and all Doors, All landing doors must have fire rating
up to 2 hours and car door must have multi-level crisscross
beam door protection.4. To & fro communication system &
wiring (i.e. car , control room & guard room ) and Each
elevator are equipped with remote monitoring
system.agency has to provide mobile app and user id and
password for monitoring 8 / 10 Passengers, Ground plus
drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for Estimated
Rates Total Amount
Rates Total Amount
Item lift is in scope of work which rating is sugested by according
Item of work Quantity Unit to estimated
No. CEICED Department (electrical Inspector) (B) SPECIAL In figure
FEATURES DESCRIPTION OF LIFTS for PREMIUM Rs. Ps.
1 category 1. Advanced control2 system dual 64 bit embedded 3 4 5
microprocessor with CANBUS Serial Communication
mode including Regenerative powe efficient operation,on
site programming facility, Anti nuisance, Pte-opening,
BMS/RMS with necessary online real time monitoring
system having necessary connectivity for remote
monitoring & other suitable supporting hardware &
software devices to fulfil the purpose.2. Floor Indication
LCD Display with call registration & brail mark with
arrival gong and hall lantern & TFT Screen in the car with
MP3 Voice Announcer. 3. CAR Panel should be Scratch
resistive SS Moonrock finish / Hair Line / Honeycomb for
car and all Doors, All landing doors must have fire rating
up to 2 hours and car door must have multi-level crisscross
beam door protection.4. To & fro communication system &
wiring (i.e. car , control room & guard room ) and Each
elevator are equipped with remote monitoring
system.agency has to provide mobile app and user id and
password for monitoring 8 / 10 Passengers, Ground plus
upper floor with Rated Speed of 1.0 m/sec., (C) With
General PLUS ADDITIONAL SPECIAL FEATURES
attached herewith. Prem. Cat.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
329 Supply, Installation, Testing & Commissioning of following size 40.00 Kw 42156.39
of Grid Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame Material : Anodized
Aluminum alloy Frame With Twin Wall Profile, Front Cover :
High Transmission Low-Iron Tempered Glass (AR Coated),
High efficency and positive power tolerance Pmax: 0/+5,
Module Efficiency should be approx. 19.5%-22%, Normal
operating temperature 45'C, Junction Box with Waterproof IP67
& MC4 Compatible and Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure error free Modules, Thep.
temp. co-efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill factor 75%
to be used. Unit Production:- More than 4.5 Unit /kw /day
(Actual)(1Year Avg) With 10 year Product warranty and 25 year
Linear Power Warranty includes all mechanical and electrical
parameters of the Solar panel. Modules must be complied to the
DCR(Domestic content requirements). The Ration of AC to DC
is 5:6 for the Installation capacity which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max
efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating
Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%,
Operating Tempreture Range: -25~60°C, Integrated protection
of Inverter are Anti-islanding Protection, Input Reverse Polarity
Protection, Insulation Resistor Detection, Ground fault
protection, Residual Current Monitoring Unit, Output Over
Current Protection, Output Short Circuit Protection, Output
Over Voltage Protection, PV array string fault Protection.
Protection Degree: IP65, User Interface LCD & APP,
Datalogger & Communication: GPRS / Wi-Fi. Integrated, Input
Reverse Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit
Integrated, Output Over Current Protection Integrated, Output
Short Circuit Protection Integrated, Output Over Voltage
Protection Integrated, Protection Degree: IP65, User Interface
LCD & APP,Datalogger & Communication: GPRS / Wi-Fi,
Module Mounting Structure: The mounting (Rectangular pipe /
square pipe / circular pipe) with requisite cross bars, nuts and
bolts, etc. shall be Hot deep galvanized with minimum
80micron coating. The Rectangular / square /circular hollow
pipe section used for the structure should have a minimum
thickness of 2.0 mm. other than above, the material thickness
should be minimum 2.5 mm. A certificate of a structural
DCR(Domestic content requirements). The Ration of AC to DC
is 5:6 for the Installation capacity which are given in AC KW. Estimated
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max Rates Total Amount
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max Rates Total Amount
Item efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating according
Item of work Quantity Unit to estimated
Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%, quantities
Operating Tempreture Range: -25~60°C, Integrated protection
of Inverter are Anti-islanding Protection, Input Reverse Polarity 3 4 5
Protection, Insulation Resistor Detection, Ground fault
protection, Residual Current Monitoring Unit, Output Over
Current Protection, Output Short Circuit Protection, Output
Over Voltage Protection, PV array string fault Protection.
Protection Degree: IP65, User Interface LCD & APP,
Datalogger & Communication: GPRS / Wi-Fi. Integrated, Input
Reverse Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit
Integrated, Output Over Current Protection Integrated, Output
Short Circuit Protection Integrated, Output Over Voltage
Protection Integrated, Protection Degree: IP65, User Interface
LCD & APP,Datalogger & Communication: GPRS / Wi-Fi,
Module Mounting Structure: The mounting (Rectangular pipe /
square pipe / circular pipe) with requisite cross bars, nuts and
bolts, etc. shall be Hot deep galvanized with minimum
80micron coating. The Rectangular / square /circular hollow
pipe section used for the structure should have a minimum
thickness of 2.0 mm. other than above, the material thickness
should be minimum 2.5 mm. A certificate of a structural
engineer certifying the strength and stability of the mounting
structure to withstand the weight and wind speed of
km/hour throughout the life span of 25 years of the system, shall
be submitted by the vendors. Hot Dipped Galvanized steel coils.
suitable arrangement for base plate for foundation , solar panel
mounting, the structure should be suitable for carry the load of
solar panel,wiring, sprinkler system etc. with necessary
foundation work/wall mount, j bolt, anchor fastner etc. the nut
bolt used for installtion of stucture should be (SS 304) quality.
The ground clearance of the bottom most edge of solar panel
shall not be less than 300 mm to 1200 mm or as per site’s
technical/feasibility requirement. a. Column –The minimum
section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be
c. Purlin - The minimum section (thickness) should be 40MM *
40MM Balane of System with necessary Swichgears (Suitabel
size and protection of ACDB & DCDB), inter connecting
wiring, earthing system as per the CEIG drawing approval,
lightining arrester system as per the CEIG drawing approval, all
liasoning work with various gov. dipartment like state nodal
agency,DISCOM & CEIG is included in agency scope
pipe section used for the structure should have a minimum
thickness of 2.0 mm. other than above, the material thickness Estimated
Rates Total Amount
Rates Total Amount
Item should be minimum 2.5 mm. A certificate of a structural according
Item of work Quantity Unit
No. engineer certifying the strength and stability of the mounting In figure to estimated
structure to withstand the weight and wind speed of 150 quantities
km/hour throughout the life span of 25 years of the system, shall
be submitted by the vendors. Hot Dipped Galvanized steel coils.
suitable arrangement for base plate for foundation , solar panel
mounting, the structure should be suitable for carry the load of
solar panel,wiring, sprinkler system etc. with necessary
foundation work/wall mount, j bolt, anchor fastner etc. the nut
bolt used for installtion of stucture should be (SS 304) quality.
The ground clearance of the bottom most edge of solar panel
shall not be less than 300 mm to 1200 mm or as per site’s
technical/feasibility requirement. a. Column –The minimum
section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be
c. Purlin - The minimum section (thickness) should be 40MM *
40MM Balane of System with necessary Swichgears (Suitabel
size and protection of ACDB & DCDB), inter connecting
wiring, earthing system as per the CEIG drawing approval,
lightining arrester system as per the CEIG drawing approval, all
liasoning work with various gov. dipartment like state nodal
agency,DISCOM & CEIG is included in agency scope
(Excluding All charges namely GEDA Application fees, Solar
connectivity Charges, Meter connectivity Charges, Meter testing
Charges and system stability/strenthning charges.) (D) Grid
Tied Solar Power System: 26 - 50 kW (3 - phase)
Total Cost of Construction Cost
(Rupees Four Crore Eighty lakh Thirty Thousand Five Hundred Eighty Two and Eighty Paise Only)
I/We am/are willing to carry out the work at ………………………………………………..% above/below
(percent should be written in figures and words) of the estimated rates mentioned above. Amount of my/our tender
works out as under.
*Estimated amount *Estimated amount
Put to tender Rs…------------------ Put to tender Rs…------------------
Deduct ……. % below Rs……………………..…. Add ……. % Avove Rs…………..….
Net Rs. …………………….… Total Rs. ………….…
The Contractor shall exhibit a board with detailed specification and details of work as directed by
the Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done
3 GST and Income tax TDS will be deducted at a source while making payments of bills.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt.G.R.: PRC-
10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where
there is a change as per actual mix design the cost of difference of cement consumption have been deducted
from the rate of original item at the rate of input rate mentioned in all the tender.
5 Dismentalling of Credit materials amounting of Rs. -5102.00 must be recovered from Contractor's respective
Deputy Executive Engineer Executive Engineer
R&B Sub Division R&B Division
Palanpur Palanpur
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 SBD_Part1.pdf
01 SBD_Part2.pdf
01 SBD_Part3.pdf
01 SBD_Part4.pdf
01 SBD_Part5.pdf
01 SBD_Part6.pdf
01 SBD_Part7.pdf
01 SBD_Part8.pdf
01 SBD_Part9.pdf
01 SBD_Part10.pdf
02 GR to be attached with DTP_SBD_with Index_Part1.pdf
02 GR to be attached with DTP_SBD_with Index_Part2.pdf
02 GR to be attached with DTP_SBD_with Index_Part3.pdf
02 GR to be attached with DTP_SBD_with Index_Part4.pdf
02 GR to be attached with DTP_SBD_with Index_Part5.pdf
03 MOU Electrical Work.pdf
04 condition of elec sub-contractor.pdf
05 Special condition electrical.pdf
06 5.0 Special Condition Excavation Work.pdf
07 BOQ.pdf
08 6.0 SPECIFICATION INDEX.pdf
09 7.0 DETAIL SPECIFICATION.pdf
10 BUILDING WORK BOOKLET.pdf
11 Technical Specification electrical _1.pdf
12 General Specification - State.pdf
14 JILLA UDHYOG KENDRA_ARCH. DRG_SCAN COPY_Part1.pdf
14 JILLA UDHYOG KENDRA_ARCH. DRG_SCAN COPY_Part2.pdf
Test Schedul.pdf
Special Condition of Contract_0001_compressed.pdf
15 year lift amc GR.pdf
Performance Bond and Bitumen date.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .