Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC PALAJIKA VALLUHER VEEDU KOSHTAN ALAKKAD NANNAMUKKU 679591 | MALAPPURAM | MALAPPURAM | KERALA | 679591 | L1 | Accepted-AOC AEE/LIDEW-DIV/MPM/230/23-24 | |
| 2 | L2₹1.6 L+₹627.73 (0.40%)Rejected-Finance 676301 | MALAPPURAM | KERALA | 676301 | L2 | Rejected-Finance L2 |
Tender Value
₹1.6 L
EMD Value
₹3,952
Closing Date
30 Sept 2023, 6:55 pmClosed
EXECUTIVE ENGIEER
Office of the Executive Engineer, LID and EW Division, Malappuram, civil station, Malappuram District Panchayath Building, Malappuram, 676505
Annual Plan - Malappuram District Panchayath Manoor kayal udanikara padasakaram irrigation project in Vattomkulam GP Electrification-1326-24 - General Electrical Work
2023_LSGD_605202_3
DB4/TN/16/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
MALAPPURAM
Please refer Tender documents.
10 documents required · 10 mandatory
₹590
₹3,952
Yes
16 Nov 2023
21 Sept 2023
2 Oct 2023
21 Sept 2023
30 Sept 2023
21 Sept 2023
Amount
wiring
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.14.24.3:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type suitable for direct connection to motors.
OD144192/2023-2024:supply and fixing Digital Multifunction meter to read: V, A, F, PF-3 phase accuracy class 1 LED
OD144306/2023-2024:supply and providing 100/ 5 A, 5 VA, 10 P 5, tape wound protection CT
OD144193/2023-2024:Supply and fixing Danger notice board of size, 125 x 75 mm
OD144194/2023-2024:supply and fixing Red, Green, blue, Yellow, Orange colours LED indicator, AC/DC, as required
OD144307/2023-2024:supply and providing CT operated, analogue type AC ammeter with 90° deflection scale, suitable dial, accuracy class 1 & of size 72 x 72 mm
OD144309/2023-2024:supply and providing 0 - 600 V analogue type AC volt meter with 90° deflection scale, accuracy class 1 & of size 72 x 72 mm
OD144340/2023-2024:Conveyance installation testing and commissioning of existing pump set using leak proof materials as required and fixing G.I. Pipe for Pumps as suction/delivery connected one by one to the motor using leak proof materials as required with necessary supports giving connection and trial run etc as per the direction at site etc as required.
OD144350/2023-2024:Conveyance and installation of existing Motor pump set starters and giving connectionsetc as required
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD144189/2023-2024:2 X 25 mm X 3 mm G.I. strip test joint Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
OD144190/2023-2024:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD144191/2023-2024:Supply and providing 25x6mm brass nut and bolt etc. as required
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.21.5:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm
OD144273/2023-2024:Supply, threading ,laying and jointing of the suitable size "B' class GI pipe with all required accessories as suction and delivery pipe with necessary clamps, supports etc as required.
OD144274/2023-2024:Supply and providing suitable size Full way valve (ISI)
OD144275/2023-2024:Supply and providing suitablesize Flange set
OD144199/2023-2024:Supply and providing 50 mm or nearest size dia Flange set
OD144198/2023-2024:Supply and providing 50 mm or nearest size dia Full way valve (ISI)
OD144276/2023-2024:Supply and providing suitable size Gun Metal Non return valve (ISI)
OD144200/2023-2024:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-6535-STD-NF] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required.
OD144246/2023-2024:Supplying and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD144247/2023-2024:Supplying and fixing 100A, HRC Fuse with HRC Fuse link with connections, in existing meter board
OD144204/2023-2024: Charges for preperation of KSEB test Report for submitting to the concerned KSEB section office
AK ELECTRICALS
Bidder Name
AK ELECTRICALS
Rafeeq P V
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_901972.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .