| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.6 L+₹1.5 L (3.42%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹46.6 L+₹2.5 L (5.74%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹50.8 L+₹6.7 L (15.2%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹50.9 L+₹6.8 L (15.5%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹91,000
Closing Date
22 Oct 2024, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
MAINTENANCE/ REPAIR/ REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY INSTALLATIONS, TRANSFORMERS, TWO/ FOUR POLE STRUCTURES, VCBs, HT PANELS, HT/LT CABLE AND HT GOD SWITCHES INCLUDING PREVENTIVE MAINTENANCE AND ALLIED WORKS AT NAVAL BASE PORBANDAR
2024_MES_675370_1
9269/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Navy Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹91,000
Yes
29 Nov 2024
19 Sept 2024
24 Oct 2024
19 Sept 2024
22 Oct 2024
3 Oct 2024
19 Sept 2024 - 2 Oct 2024
Amount
M & L for general maintainance of 11 KV VCB's of different capacities and comprising the following: Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800/1000 Amps from location and repair /overhauling and carrying out with the following and all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.)
(a) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly switch assembly and apply multi grease lubricant to function smoothly. (b) Inspecting / overhauling of earthfault release assembly, tripping coil, auxilary switch etc and checking of electrical wiring system. (c) Calibration & Testing of over current & Earth fault relay by primary & secondary ejection methods. (d) Insulating of VCB track, greasing of wheel and checking for few movement for closing and withdrawing of VCB track. (e) Cleaning/wiping the insulating components, primary & secondary circuits i.e green spots, carbon deposited completely.Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interupters by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (f) Testing of primary & secondary circuit with 1000 Volts megger for insulation resistance. (g) Flash testing of secondary circuit at 2000Volts for one minute after disconnecting the instruments from the panel. Assembling all items/components parts to the respective postion after high voltage test complete. (h) Testing, sychronisation / calibration of meters and relays. (i) Cleaning/wiping of busbar, phase barriers, Busbar support and sleeves. (j) Scraping & painting the VCB (06 Nos) with approved quality of grey paint all as directed by Engineer-in- Charge.
Dehydration of tranformer oil, obtained from transformers/voltage stabilizer etc. Dielctric strength shall not be less than 40 KV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine including replacement of unserviceable silica gel and toping up/ replacement of unserviceable transformer oil complete all as directed. Note :- 1) Silica gel & new tranformer oil for top up shall be measured and paid against respective item. 2) Filteration of transformer oil shall be off loaded position of transformer.
Supply and filling transformer oil of approved quality ISI marked for filling in transformer for topping up/ replacement complete all as directed by Engr-In-Charge. Make: power/castrol/servo/asian/savita/electric. Note :- (i) Dielectric strength of transformer oil not less than 60 KV with 2.5mm gap. (ii) New oil which is to be supplied for filling should be in a sealed barrel/container only.
Supply and fixing in repair of breather with 500 Grams silica gel for transformer upto 400 KVA, all as specified and directed by Engineer-in-Charge.
Taking of old silica Gel for dehydrating Breather of transformer, cleaning the breather internally and externally and filling new silica gel blue colour in dehydrating breather.
M &L for painting of transformer upto 400 KVA capacity any type with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface of transformer complete all as specified and as directed by Engineer-in-Charge.
M & L for cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of cable size 95 sqmm complete all as specified.
M & L for cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of cable size 95 sqmm complete all as specified.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of of cable size 95 sqmm complete all as specified.
S& f in replacement of Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, rocking tilting type consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,400 Amps all as specified.
S& f in replacement of Lightning arrester non linear type complete with all fittings distribution class discharge capacity 65 kilo amp, current rating 5 kA suitable for 11000 volt complete with all fittings including taking down old
S& f in replacement of drop out fuse assembly for 11 KV, 3 Phase of 100 Amp capacity each pole, consisting of galvanized steel base paper fuse carrying brackets, mounting channel, separating rod complete all as specified as directed by Engr-in-Charge.
Dismantling of U/S existing cross arms by means made from channels, angles, U/S FI clamps, nuts, bolts etc. from OH line and removing complete.
M&L for Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
Supply and erect in replacement of steel tubular swaged poles complete with cast iron base plate, nuts and taper plug , bolts, nuts and screws as specified type HT pole type 410-SP-55 (11mtr long)
Taking up of under ground HT Cable of any size along with protection cover/ bricks and removing from site all as directed by Engr-in-Charge.
M&L XLPE insulated screned PVC beded galvanised steel strip or wire armoured earthed electric power cable (heavy duty) with aluminium couductor 11/6.35 KV grade suitable for earthed system cross sectional area 95 sqmm 3 core H.T.U.G cable laid in tranches/through GI pipe/fixed along with pole complete all as specified & directed Note -Excavation and earth work shall be measured and paid for separately under relevant item of schedule.
Taking down unservisable U/G LT cable from trenches, wall, floor etc single/multicore any type,size all as directed by Engr-in-Charge.
S& F in repair XLPE insulated armoured and pvc sheated heavy duty electric cable size 4 core ,10 Sqmm cross sectional area with aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete note- rate is inclusive of cable gland & cable lugs Note -Excavation and earth work shall be measured and paid for separately under relevant item of schedule.
All as per item No.19.00 above but of size 25 sq mm X 3.5 core
All as per item No. 19.00 above but of size 50 sq mm X 3.5 core
All as per item No.19.00 above but of size 70 sq mm X 3.5 core
All as per item No.19.00 above but of size 95 sq mm X 3.5 core
M & L for Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth getting out for the pole foundation/cable all as directed in Hard/dense soil complete all as specified and directed.
All as per item no 24.00 above but depth exceeding 1.5 mtr and not exceeding 3.00 mtr deep and getting out.
M & L for Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm in thick all as specified and directed.
M & L for Removing excavated material to a distance not exc 50 mtr and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified by the Engineer-in-charge.
M&L for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation of poles etc all as specified.
M&L for Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole
S& F in replacement of laying of Double Walled Corrugated (DWC) HDPE pipe of following size of conforming to IS 16205 Part -24 including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge Make:-ASTRAL TELEREX /eqivalent as approved by GE
40/32 mm outer/inner dia
50/38 mm outer/inner dia
63/50 mm outer/inner dia
75/63 mm outer/inner dia
90/75 mm outer/inner dia
S&F of GI Tubing light grade 80mm for cable protection, laid under plinths/floors /roads /culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts washers etc complete all as specified.
S&F of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade all as specified and directed by Engr-in-Charge.
S & F of HT disc insulator porcelain vitreous 145mm height, 255mm dia, ball and socket type. White / brown with M.S. galvanized iron fitting suitable for working pressure 11KV all as specified and directed by Engr-in-Charge.
S&F of PVC junction box of size inside dimenssion 250x200x100 mm complete with industrial connector, including clamp made out of MS flat iron 30x5 mm , nut, bolts, washer, glands etc , MCB 6-10Amps complete all as specified & directed Make:Sintex cat no : GS JB 2520
M&L for Phase barrier with spacers of 11KV VCB including taking down old unserviceable or burnt Phase barrier. Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.
M&L for test / service limit switch of 11KV VCB including taking down old unserviceable or burnt Support rod with allen bolt. Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.
M&L for TNC switch of 11KV VCB including taking down old unserviceable or burnt TNC switch Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.
M&L for Closing coil assembly of 11KV VCB including taking down old unserviceable or burnt Closing coil assembly Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.
M&L for Tripping coil assembly of 11KV VCB including taking down old unserviceable or burnt Tripping coil assembly Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.
M&L for Motor gear assembly UMG of 11KV VCB including taking down old unserviceable or burnt Motor gear assembly UMG Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.
M&L for Big and small gear assembly of 11KV VCB including taking down old unserviceable or burnt Big and small gear assembly Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.
M&L for cut of motor limit switch of 11KV VCB including taking down old unserviceable or burnt cut of motor limit switch Of feeder panel. all as per directed by Engr In Charge. Make - Crompton greaves power or as per the sample of existing.
M&L for Auxiliary switch of 11KV VCB including taking down old unserviceable or burnt Auxiliary switch Of feeder panel. all as per directed by Engr In Charge. Make - Crompton greaves power or as per the sample of existing.
M&L for Tripping Shaft with spring and trip strips of 11KV VCB including taking down old unserviceable or burnt Tripping Shaft with spring and trip strips Of feeder panel. all as per directed by Engr In Charge. Make - Crompton greaves power or as per the sample of existing.
M&L for closing Shaft with spring and trip strips of 11KV VCB including taking down old unserviceable or burnt closing Shaft with spring and trip strips Of feeder panel. all as per directed by Engr In Charge. Make - Crompton greaves power or as per the sample of existing.
M&L for Bridge rectifier of 11KV VCB including taking down old unserviceable or burnt Bridge rectifier Of feeder panel. all as per directed by Engr In Charge. Make - Crompton greaves power or as per the sample of existing.
M&L for Fixing and testing of Vaccum intrupter o f 11KV VCB including taking down old unserviceable or burnt Vaccum intrupter Of feeder panel. all as per directed by Engr In Charge. Make - Crompton greaves power or as per the sample of existing.
S& F in replacement of Over Current & Earth Fault Protection Relay fully digital relay based on microprocessor technology with analog to digital conversion of the measured values and subsequent numerical processing. Make :- CG /Scheinder/ABB
M&L for Fixing and testing of Spout bushing o f 11KV VCB including taking down old unserviceable or Spout bushing Of feeder panel. all as per directed by Engr In Charge. Make - Crompton greaves power or as per the sample of existing.
M&L for Fixing and testing of Current transformer resin cast ratio 100-50/5-5A. o f 11KV VCB including taking down old unserviceable or Current transformer resin Of feeder panel. all as per directed by Engr In Charge. Make - Crompton greaves power or as per the sample of existing.
Supply and spread and leveling Graded coarse Aggregate in loose filling over the surface of gauge 40 mm nominal size in the installation yard including removal of unwanted plants, grass, bushes around installation complete all as specified and as directed by Engr-in-charge.
Supply and fixing of 11 KV VCB electric panel heater , voltage 230 V all as specified and directed by Engr-in - charge.
Supply and fixing of gasket for VCB panel door all as specified and directed by Engr-in-Charge.
Repair and Maintenance of Rack in out gear assembly of 11 KV VCB complete all as specified and directed by Engr-in -Charge.
Supply and fixing LED Indicator lamp suitable for 11 KV VCB with complete colour coding . All as specified and directed by Engr -in-charge.
Supply and fixing of Cut out Fuse suitable for 6 amp DC Supply for 11 KV VCB including complete arrangement as per site requirement All as specified and directed by Engr -in-charge.
M&L Earthing with 600X600X6 mm thick , galvanised steel earth plate electrode buried vertically in ground (Earth pit not less than 2.25 meter deep below normal ground level ) with top edge of plate vertically at a depth ,not less than 1.5 m below ground level connected to and including GI strip of size 32X6 mm by means of bolts,nuts,check nuts, And washer of galvanised steel, Gi shrip to be provide upto the extent of 7.5 m GI strip to be duly connected to metalic bodies of HT/LT equipment with provision of mixture of charcoal dust & common salt packed all ground the earth plate upto MS funnel with wire mesh provided inside concrete earth pit for watering arrangement,complete all as shown on electrical plate no.3 of SSR Part I (2009) and testing on completion.
Earthing continuity galvanised iron strip 32 x 6 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
Taking down old u/s LT panel of any size/ make/ including all unserviceable parts removing from site all as directed & specfied at site
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 320 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 320 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT of suitable ratio (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (g) Incoming MCCB 200A TPN 25 kA (Legrand- 4202 18) (B) Outgoing:- (a) MCCB 125 A TP 25 KA (LEGRAND- 4200 46) -02 No (b) MCCB 100 A TP 25 KA (LEGRAND- 4200 45) -02 No (d) MCCB 63 A TP 25 KA (LEGRAND- 4200 43) -02 (e) All out going LT feeders name with radium stickers Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 400 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e)CT of suitable ratio (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (g) Incoming MCCB 250A TPN 25 kA (Legrand- 420219) (B) Outgoing:- (a) MCCB 200 A TP 25 KA (LEGRAND- 4202 08) -02 No (b) MCCB 100 A TP 25 KA (LEGRAND- 4200 45) -01 No (d) MCCB 63 A TP 25 KA (LEGRAND- 4200 43) -01 (e) All out going LT feeders name with radium stickers Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 400 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT of suitable ratio (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (g) MCCB 250A TPN 25 kA (Legrand- 420219) (h) All out going LT feeders name with radium stickers Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 400 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT of suitable ratio (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (g) Incoming MCCB 160A TPN 25 kA -01 No (Legrand- 4200 57) (B) Outgoing:- (a) MCCB 100 A TP 25 KA (LEGRAND- 4200 45) -03 No (b) MCCB 63 A TP 25 KA (LEGRAND- 4200 43) -4 (c) All out going LT feeders name with radium stickers. Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 320 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 320 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT of suitable ratio (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (g) Incoming MCCB 160A TPN 25 kA-01 No (Legrand- 4200 57) (B) Outgoing:- (a) MCCB 100 A TP 25 KA (LEGRAND- 4200 45) -02 No (b) MCCB 63 A TP 25 KA (LEGRAND- 4200 43) -4 (c) All out going LT feeders name with radium stickers. Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 320 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 320 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (g) Incoming MCCB 160A TPN 25 kA -01 No (Legrand- 4200 57) (B) Outgoing:- (a) MCCB 100 A TP 25 KA (LEGRAND- 4200 45) -01 No (b) MCCB 63 A TP 25 KA (LEGRAND- 4200 43) -05 (c) All out going LT feeders name with radium stickers Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 320 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 320 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (g) Incoming MCCB 125A TPN 25 kA (Legrand-4200 56) -01 Nos (B) Outgoing:- (a) MCCB 80 A TP 25 KA (LEGRAND- 4200 44) -01 No (b) MCCB 63 A TP 25 KA-04 no (LEGRAND- 4200 43) (c) All out going LT feeders name with radium stickers Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
Nitesh Enterprise (BID ID -3146658)
ALBA AC AND REF SERVICES (BID ID -3147146)
SURESH ELECTRICALS (BID ID -3146999)
shree chamunda enterprise (BID ID -3142053)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .