Loading…
Loading…
Tender Value
₹6.7 Cr
EMD Value
₹6.7 L
Closing Date
27 Apr 2026, 12:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Chief Officer
Bid Document of Proposed Sewerage Pipe line System with Pumping Station, Rising Main, Electro Mechanical Work & House Service Connection with Operation & Maintenance for next 24 Months @ Kheda Nagarpalika, Kheda Dist. Kheda (Without GST) (2nd Attempt)
295157
2026-27
Open
Sanitory Work
Kheda
3 documents required · 3 mandatory
₹14,160
Chief Officer Kheda Nagarpalika
₹6.7 L
7 Apr 2026
7 Apr 2026
7 Apr 2026
27 Apr 2026
7 Apr 2026
Schedule - B: Summary of Price-Total Price for Evaluation of Bid
Bid Document of Proposed Sewerage Pipe line System with Pumping Station, Rising Main, Electro
Mechanical work, House Service Connection with Operation & Maintanance for next 24 Months
of Kheda Nagarpalika
ESTIMATED AMOUNT
SCHEDULE (IN RS.)
Proposed Sewarage Network of Kheda Camp Area, Bhatta
Area and Express Line upto Harijanvas P/S
Construction of Sewage Pumping Sation at Kheda Camp Area
Rising Main from Kheda Camp SPS to Ex. Main SPS and Ex.
Vithalpara SPS to Ex. STP
B-4 House Service Connection
Electro - Mechanical Work in Kheda Camp Pumping Station
at Vithalpara Pumping Station
Sub Total (B-1 to B-5)
C-1 Operation and Maintanance for 2 Years
Total with O & M
I/We am/are willing to carry out the work @ __________% _______ percent (should be
writer in figures and words) below/above /at par , the estimated rates mentioned above,
amount of my/our tender works out as under:
(* Please strike out whichever is not applicable)
Above all items of “Schedule-B” with Item Description, Unit, Qty, Rate and Amount have
verified by me and found in order.
Bidder’s Stamp and Initials
Proposed Sewarage Network of Kheda Camp Area, Bhatta Area and
Express Line upto Harijanvas P/S
Item Description Quantity Unit Rate
1.00 Excavation for pipeline tenches for sewerage
line, manhole with shoring & shruting if
required as per required gradient and line
including all safety provision using site rails
and stacking excavated stuff including up to all
required lead cleaning the site etc. complete for
all lift and strata as specified.In all sorts of Soil
and soft murrum. In all sort of soils and soft
(For Pipe & Manhole)
2.00 Extra rate over item of excavation of earth if
excavation is to be done in wet condition
without resorting to pumping out incl. of
bailing out of water.
3.00 Providing bedding incl. ramming, watering,
consolidating etc. as per standard and
instruction of engineer incharge. As above
with required quality Sand brough from
outside including all lead. 263.00 m3 378.35
4.00 RCC PIPES :- Providing & Supplying ISI
Standard RCC Pipes ( of Sulphate Resisting
Cement ) In Standard Lengths Of Following
Class and diameter Suitable For Either Collar
Joints or Rubber ring joints including all taxes,
Insurance, Transportation Freight Charges,
octroi, Inspection Charges, Loading Unloading
Conveyence Up To Departmental Stores
Stackign Etc. One collar should be supplied
with each full length plain ended RCC pipe,
also one rubber ring should be supplied with
each full length stocketed pipe. RCC NP3 Test
Pressure 0.7Kg /Sq cm and RCC NP4 IRS
Class Horizontally Cast.
RCC NP3 Pipe Test Pressure 0.7Kg /Sq cm
4.01 RCC NP4 Pipe IRS Class
5.00 Lowering, laying & jointing R.C.C pipes in
C.M. 1:1.5 for following dia in proper position,
grade and alignment as directed by Engineer -
in-charge including conveyance from store to
site of work. Labour giving Hydraulic testing
as per ISI code.
R.C.C. PIPES (At any Depth)
6.00 Providing and constructing Sewer manholes as
per the type design in brick masonary in C.M.
1 : 5 and inside and outside 20 mm thick
plastering in C.M. 1:3 necessary 100 mm
coping with reinforcement in R.C.C. M
providing and fixing C.I. steps and fixing
manhole frame and covers (But excluding
supply of manhole frame and covers) over
manholes etc. complete, providing and fixing
safety chain wherever necessary as per the
stipulations in the type design complete as per
latest CPHEEO manual. (excl.
excavation)Manhole type "A" circular type
having inside diameter of 1200 mm for
depth upto 1.5 m depth (For 150 mm to
mm dia sewer)* Manhole type "A" as above
but upto 1.0 m depth 16.00 No. 14005.85
6.01 * Extra depth beyond 1.0 mt. but upto 1.5 mt.
depth for "A" type manhole above. 12.00 Rmt. 7622.20
6.02 Manhole type "B" circular type having
inside diameter of 1500 mm and for depth
from 1.5 m to 4.0 mt. (For 150 mm to
* Manhole type "B" as above but upto 1.5 m
6.03 * Extra depth beyond 1.5 mt. but upto 4.0 mt.
depth for type "B" manhole above. 212.00 Rmt. 14159.95
6.04 Manhole type "C" circular type having
inside diameter of 1500 mm and for depth
from 4.0 m to 6.0 mt. (For 150 mm to
* Manhole type "C" as above but upto 4.0 m
6.05 * Extra depth beyond 4.0 mt. but upto 6.0 mt.
depth for type "C" manhole above. 40.00 Rmt. 21603.90
7.00 R.C.C. precast M.H. Frame & Cover
manufacture, supply & delivery at store or at
site of work precast R.C.C. m 200 Frame &
Cover suitable to drainage M.H. and as per
type design &drawing including cost of
reinforment M.S. Angles or Flat, curing mold
* Frame suitable for 50 cm opening of MH &
Cover suitable for 50 cm opening of MH 175.00 No. 2294.00
8.00 Refilling the pipeline trenches including
ramming, watering, consolidating disposal of
surplus stuff as directed within a radium of
9.00 Making connection to the ex. M.H. in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipes at any
convenient time. All damaged work shall be
well repaired as per instructions.etc. complete.
10.00 Extra rate over item of excavation of earth for
excavation of asphalt pavement/RCC of
thickness upto 0.2 mt. including demolishing
the asphalt carpet, metal, solling/cutting
reinforcement etc. complete with stacking the
material as directed.
* Upto 0.2 meter thickness (By Manual) 781.00 Smt. 72.15
11.00 Providing, laying, spreading and compacting
graded aggregate to wet mix macadam
specification including stone premixing the
Material with water at OMC in mechanical mix
plant carriage of mixed Material by tipper to
site, laying in uniform layers in subbase/ base
course on well prepared surface and
compacting with vibratory roller to achieve the
desired density as per MoRTH clause 406. 196.00 m3 1146.95
12.00 Demolition including stacking of serviceable
materials and disposal of unserviceable
materials with all lead and lift.
13.00 Demolition and disposal of unserviceable
materials with all lead and lift.
* Unreinforced cement concrete 300.00 m3 306.79
14.00 Construction of 200 mm thick un-reinforced,
dowel jointed, plain cement concrete pavement
with M - 35 grade of concrete including
provision of contraction, expansion,
construction and longitudinal joints, joint
filler,sealant primer, joint sealant,, dowel bar,
tie rod, admixtures as approved, finishing to
lines and grades as per drawing as per MoRTH
clause 602 over a 200 mm thick WMM with
necessary excavation/loosening and
recompacting ground as per respective
MoRTH specification and as directed by
engineerin charge. 1207.00 Smt. 1314.00
15.00 Providing & erecting C.I & M.S ventilating
column 15 cms dia with CI ornamental cap and
min 6 mt height (height may be varying as per
site )base fixed firmly with necessary
foundation with one coat of red oxide paint and
one coat of any approved colour with 15 cms
dia 10 mt in length with 0.35*0.35 mt* m100
encasing,RCC pipe connection with M.H
including excavation and jointing as required
etc complete as per drawing.
* For 12 Mt height 12.00 No. 47414.50
16.00 Dewatering by pumping set of required
capacity including temporary platform carting
pumping at site and fixing the same in position
including all accessories, and fuel and labour
* Pump set of capacity 14241.00 HP/hr 21.07
Construction of Sewage Pumping Sation at Kheda Camp Area (Civil Work)
Item Description Quantity Unit Rate
1.00 Excavation for foundation for loose and soft
soil including sorting out and stacking of
useful materials and disposing of the excavated
stuff up to 50 meter lead.
1.02 * From 3 to 5.0 m.
2.00 Filling with available excavated earth
(excluding rock) in trenches, plinth, sides of
foundation in layers not exceeding 20 cm in
depth consolidating each deposited layer by
ramming and watering. 355.00 m3 78.55
3.00 Filling in plinth with sand under floors
including water ramming, consolidating and
dressing complete. 50.00 m3 300.30
4.00 Extra rate over item of excavation of earth if
excavation is to be done in wet condition
without resorting to pumping out incl. of
bailing out of water. 150.00 m3 20.00
5.00 Providing and casting in situ C.C. in grade M-
15 (approx. corresp. to prop. 1:2:4)
(proportions as per mix design or as per Table
9 of IS456 2000 in masses by weigh batching )
using granite, quartzite trap metal of size 6 mm
to 20 mm for RCC work, including scaffolding
centering, form work, needle vibrated
consolidation, curing comp. up to 6 meter
depth or height (excluding cost of
reinforcement and neat finishing) with
centering and shuttering/deshuttering etc.
comp. for structure for other than water
retaining. Footing (With form work) 9.00 m3 4906.00
6.00 Providing and cast in situ C.C. in grade M-30
proportions of ingredients as per mix design by
weigh batching using granite, quartzite trap
metal of size 12 mm to 20 mm and or 6 mm to
12 mm including scaffolding centering
formwork, needle vibrated consolidation,
curing and hydraulic testing etc. complete
(excluding cost of reinforcement) with
centering and shuttering/deshuttering etc.
camp. up to 6 meter height /depth Av. G.L.for
all water retaining structures.
* R.C.C. slab and footings 16.00 m3 8213.00
6.01 * R.C.C. walls
6.02 * R.C.C Beams
6.03 * Slab & Platform
6.05 * RCC Column
6.06 * R.C.C. Pedestal
7.00 Providing and cast in situ C.C. in grade M-25
proportions of ingredients as per mix design by
weigh batching using granite, quartzite trap
metal of size 12 mm to 20 mm and or 6 mm to
12 mm including scaffolding centering
formwork, needle vibrated consolidation,
curing and hydraulic testing etc. complete
(excluding cost of reinforcement) with
centering and shuttering/deshuttering etc.
camp. up to 6 meter height /depth Av. G.L.for
all water retaining structures.
* R.C.C. beams, lintels and bracket for gantry
or chain pully blocks, plinth beams, tie beams. 7.00 m3 8347.00
7.01 * R.C.C. slabs and platform
7.02 * R.C.C. weather shed, pardi & staircase
7.03 * R.C.C. columns
7.04 * R.C.C. footing
8.00 Providing and casting in situ C.C. in grade M-
20 (proportions as per mix design or as per
table 9 of IS456 2000 in masses by weigh
batching) using granite, quartzite trap metal of
size 6 mm to 20 mm for RCC work, including
scaffolding centering, formwork, needle
vibrated consolidation, curing complete
(excluding cost of reinforcement and neat
finishing) with centering and
shuttering/deshuttering etc. complete for
structure other than water retaining (Below 5.00 m3 5520.00
9.00 Supplying cutting, bending, binding and
placing in position steel as per plan and design
and as per ISS 2502 including cost of steel and
binding wire for reservoirs/structures only
including lift below G.L. for all diameters.
* Do - deformed (TMT) bars confirming to
relevant IS Fe - 500 grade for all diameters. 14.00 MT 77504.00
10.00 Providing and fixing water tight construction
or expansion joints 150 mm. dia. Wide thin
ribbed PVC. 83.00 Rmt. 330.00
11.00 Half brick masonary in common burnt clay
building bricks having crushing strength not
less than 35 Kg/cm2 in cement mortar (1:4) in
super structure. 5.00 m2 391.97
12.00 Brick work using common burnt clay building
bricks having crushing strength not less than
35 Kg/cm2 in foundation and plinth in cement
mortar 1:6 (1 cement : 6 coarse sand). 5.00 m3 2503.48
13.00 Brick work using common burnt clay building
bricks having crushing strength not less than
35 Kg/cm2 in superstructure and parapet in
cement mortar 1:6 (1 cement : 6 coarse sand) 30.00 m3 2661.61
14.00 Providing and applying 20 mm thick inside
OPC cement plaster with water proofing agent
on inside of sump consisting of 12 mm thick
backing coat of CM 1:3 (1 cement : 3 sand) and
8 mm thick finishing coat of CM 1:1 (1 cement
: 1 sand) etc. complete including necessary
curing, scaffolding required if any etc.
complete. 130.00 m2 303.00
15.00 Providing and applying 20 mm thick sand
faced cement plaster at outside RCC / brick on
work upto height 10 mtr. above ground level
consisting of 12 mm thick backing coat of C.
M. 1:3 (1 cement : 3 sand) and 8 mm thick
finishing coat of C. M. 1:1 (1 cement : 1 sand)
etc. complete. 130.00 m2 197.81
16.00 Providing and applying 10 mm thick cement
plaster in single coat on concrete work for
interior plastering upto floor two level finished
even and smooth in Cement mortar 1 : 3 (1
cement : 3 sand) in a single coat over RCC slab
(on ceiling) etc. complete as directed (In
ceiling of pump house & Room). 120.00 m2 85.13
17.00 Providing and applying 15 mm thick cement
plaster in single coat on brick work with
floating coat of net cement slurry for interior
plastering of pumphouse and outside
plastering of sump upto finished even and
smooth in Cement motar 1 : 3 (1 cement :
sand) including racking out joint curing,
scaffolding required if any, with necessary
cement finishing etc. complete as directed. (In
pump house and Room). 25.00 m2 142.79
18.00 Providing and laying 40 mm thick cement
concrete flooring in 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm
nominal size) including water proofing
compound finishing with a floating of neat
cement etc. complete laid in one layer finished
including necessary curing with sulphate
resistant cement. 20.00 m2 190.64
19.00 Providing and laying 40 mm thick heavy duty
cement concrete flooring in 1:2:4 (1 cement :
coarse sand : 4 graded stone aggregate 20 mm
nominal size) with ironite powder including
finishing with a floating of neat cement etc.
20.00 Providing and laying cement concrete flooring
1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) including
finishing with a floating of neat cement etc.
complete laid in one layer finished including
necessary curing and with water proofing
compound with ordinary Portland cement.
21.00 Providing and laying polished Kota stone slab
25 mm thick in riser of steps, dado & pillars,
skirting, laid on 10 mm thick cement mortar
1:3 (1 cement : 3 coarse sand) and jointed with
grey cement slurry including rubbing and
polishing etc. complete. 20.00 m2 664.69
22.00 Distempering in 3 coats with oil bound
distemper of approved brand and manufacture
and of required shade on wall surface to give
an even shade over and including a primer coat
with distemper primer of approved brand,
thoroughly brushing the surface free from
mortar dropping and other foreign material and
also inclusive of preparing the surface even
and smooth etc. complete. 145.00 m2 59.91
23.00 Providing and applying epoxy paint of
approved make to concrete surface for RCC
structure including cleaning the surface by
scrapping and air blowers to the satisfaction of
Engineer-in-charge necessary scaffolding etc.
complete with all leads and lifts and giving
satisfactory hydraulic test for water tightness
as per IS codes.* For new surface-Two coats. 130.00 m2 90.00
24.00 Wall painting (two coats) with plastic
emulsion paint of approved brand and
manufacture of undercoated wall surface to
give an even shade including thoroughly
brushing the surface free from mortar dropings
and other foreign matter and sand papered
smooth. 130.00 m2 46.50
25.00 Providing and fixing window having extruded
aluminum Colour anodized section frame main
outer size 95mm x 24mm x 1.17 mm (of Jindal
Section no : 2459 @ wt. of 0.738 Kg/mt),
horizontal Three track member size 92mm x
31.75 mm x 1.30 mm (of Jindal Section no.
8688, @ Wt. 1.07 Kg/mt), vertical member of
size 92mm x 31.75mm x 1.50 mm (of Jindal
Section no. 8933, @ Wt. 1.06 Kg/mt.) with
sliding shutters of horizontal member size
40mm x 18mm x .29 mm (of Jindal section no.
8947 @ wt. 0.456 Kg/mt.) vertical member of
size 40mm x 18mm x 1.29mm (of Jindal
Section no. 8949 @ wt. of 0.456 Kg/mt with
mm thick transparent bronze colour tinted float
glass with powder coated aluminum fittings
and fixtures and transparent silicon sealant
glass fixing to frame as per details etc. 3.00 m2 1652.31
26.00 Providing and fixing 50 cm wide M.S. Ladder
fabricated from M.S. Flats 10 mm x 75 mm
with 20 mm dia steel bar steps in double rows,
@ 30 em C/C. The include stays of 10 mm x
50 mm flats fixed at 3 meter C/C wtih welding
anchoring and 3 coats anticorrosive paint. M.S.
ladder (without safty cage) 7.00 Rmt. 2950.00
27.00 Providing and fixing 40mm dia. GI pipe
medium weight quality as openable type with
angle iron support at 1.5 m c/c using 75 x 75 x
10 mm angles, 1 m long with three rows of
pipes as railing including necessary painting
with two coats of approved quality oil paint
over one coat of approved primer including
necessary welding, bolting required, if any. 10.00 Rmt. 1784.00
28.00 Supplying, cleaning, cutting, bending,
welding, 'fabricating, erecting structural steel
in position irrespective of locations and levels
as per drawing including handling and
transport etc. complete including applying two
coats of primer red oxide and two coats of
approved quality of paint over it etc. complete
as directed for gentry girder, platform, stairs,
chequered plate for cable trench etc. 600.00 Kg 99.00
29.00 Providing and fixing MS grating with 8 mm
thick 50 mm wide flat at 50 mm c/c to form
grid pattern as specified and wherever directed
including two coats of approved quality oil
paint with one coat of primer red oxide etc.
complete. 5.00 m2 12590.00
30.00 Providing and fixing plastic moulded
reinforced steps with 10 mm TOR steel bar
with plastic polyproclene (P.P.) material
(vergin) etc. complete. 18.00 No. 87.00
31.00 Providing and fixing to wall, ceiling and floor
10.0 Kg.F/cm2 working pressure polythene
pipes of the following outside Dia. Low
density complete with special flange
compression type fittings, wall clips etc.
including making good the wall ceiling and
32.00 Grouting with 1:3 cement mortar for anchor
bolt pockets machine bases, pipe sleeves,
pocket holes etc. including roughening and
cleaning of concrete surfaces curing etc.
complete. 2.00 m3 3083.93
33.00 Providing, Cement vata (10 cm x 10. cm size)
quarter round in cement motar 1:1 including
neat cement finishing, watering etc. complete. 21.00 Rmt. 17.25
34.00 Providing 100 mm x 100 mm size vata in
cement concrete (1:2:4) including water
proofing compounds, smooth finish, curing,
etc. complete for the internal side of the sump,
pump house and chlorination room. 19.00 Rmt. 41.00
35.00 Supplying & fixing insert plate of size 150 x
150 x 6 mm in wall alongwith ISA 100 x
x 8 mm angle in position for support of vertical
delivery pipe, as per drawing including
handling and transporting etc. complete. 5.00 No. 74.00
36.00 Providing and fixing 1.20 Metre high fencing
with 2.0 Metre long M.S. Angle posts 40 mm
x 40 mm x 6 mm and oil painting 3 coats fixed
at 2.5 Mt, C/c with five Horizontan line sand
two diagonals of galvanised steel barbed wire
weighting 9.38Kg. per 100 Metre, strained and
fixed to posts with G.I,staples including fixing
the posts in ground with 0.5 M x 0.5 M x
M. block in C.C 1:5:10 etc complete. 80.00 Rmt. 293.44
37.00 Fabricating and fixing in position MS
structural section such as flat, pipes, plates,
hold fast, anchoring bolts / bars of required size
including fixing, welding and two coats of
approved anti corrosive paint over prime coat
of red-oxide including RCC gate column as per
drawing etc. complete as directed by Engineer-
in-charge. 350.00 Kg 56.45
38.00 Dewatering by pumping set of required
capacity including temporary platform carting
pumping at site and fixing the same in position
including all accessories, and fuel and labour
etc. complete. 27220.00 HP/hr 18.32
Rising Main from Kheda Camp SPS to Ex. Main SPS and Ex. Vithalpara SPS to Ex. STP
Item Description Quantity Unit Rate
1.00 Excavation for pipe line trenches,etc. for all
with shoring and strutting if required as per
required gradient and line including safety
provisions using site rails and stacking
excavated stuff including up to all required
lead cleaning the site etc. complete for all lifts
and strata as specified.
In all sort of soils and soft murrum
2.00 Providing, supplying D. I. K-9 grade pipes
with EPDM gasket for following nominal bore
diameter with internal cement mortar lining
including all taxes, insurance, transportation,
freight charges, octroi, inspection charges,
loading, unloading, conveyance to
departmental stores, stacking etc. complete.
* 150 mm dia DI K-9 with EPDM Gasket 6800.00 Rmt. 1655.00
3.00 Lowering, laying and jointing DI Pipes of
various classes with specials of following
diameters in propoer position grade and
alignment as directed by Engineer in charge
including hydraulic testing etc. complete.
* 150 mm dia DI K-9 with EPDM Gasket 6800.00 Rmt. 113.85
4.00 Manufacture, supply & delivery ,including
fixing of Ductile Iron flange socket spigot
bends, tees, reducers of any other specials as
per BS-EN-545/1995 class-A series K12
suitable for use with DI pipes manufactured
per IS 8329/1994 delivery of specials is to be
made to Store or site of works any where
including all taxes, loading, unloading,
carting, stacking, insurance, inspection
charges, octroi etc. complete.
* upto 300 mm dia 4563.00 Kg 148.00
5.00 Providing and casting in situ C.C. in grade M-
20 (proportions as per mix design or as per
table9 of IS456 2000 in masses by weigh
batching ) using granite, quartzite trap metal
of size 6 mm to 20 mm for RCC work,
including scaffolding centering, formwork,
needle vibrated consolidation, curing
complete (excluding cost of reinforcement and
neat finishing) with centering and
shuttering/deshuttering etc. complete for
structure other than water retaining (Below
* RCC ( For Thrust block & encasing) 78.00 m3 6348.00
6.00 Providing and casting in situ C.C. in grade M-
15 (approx. corresp. to prop. 1:2:4)
(proportions as per mix design or as per Table
9 of IS456 2000 in masses by weigh batching
) using granite, quartzite trap metal of size
mm to 20 mm for RCC work, including
scaffolding centering, form work, needle
vibrated consolidation, curing comp.
(excluding cost of reinforcement and neat
finishing) with centering and
shuttering/deshuttering etc. comp. for
structure for other than water retaining.
* Footing (without form work) (For Thrust
7.00 Supplying cutting, bending, binding and
placing in position steel as per plan and design
and as per ISS 2502 including cost of steel and
binding wire for reservoirs/structures only
including lift below G.L. for all diameters.
* Do - deformed (TMT) bars confirming to
relevant IS Fe - 500 grade for all diameters. 2.00 MT 89129.60
8.00 Refilling the pipeline trenches including
ramming, watering, consolidating disposal of
surplus stuff as directed within a radium of
9.00 Providing, supplying ISI mark Cast Iron D/F
Sluice Valves of following class and diameter
including all taxes, insurance, transportation,
fright charges, Octroi Inspection charges,
loading, unloading, conveyance to site
stacking, etc. complete.
PN-1 with hand wheel /cap operated ( PD
Type short body)
10.00 Lowering, laying & jointing in position
following Sluice Valves including cost of all
labour, jointing material, including nut bolts &
giving satisfactory hydraulic testing, etc.
PN-1 with hand wheel /cap operated ( PD
Type short body)
11.00 Providing, supplying,& fixing CI Tamper
proof /Bi Stream Air valves with SS 304 Float
gun metal nozzle of approved make & quality
of following class and diameter including all
taxes, transportation, freight charges, octroi,
inspection charges, loading, unloading,
conveyance to the departmental stores,
stacking etc. complete.
With Isolating Sluice Valve PN
12.00 Lowering, laying & jointing in position
following air Valves including cost of all
labour, jointing material, including nut bolts &
giving satisfactory hydraulic testing, etc.
With Isolating Sluice Valve PN
13.00 Extra rate over item of excavation of earth for
excavation of asphalt pavement/RCC of
thickness upto 0.2 mt. including demolishing
the asphalt carpet, metal, solling/cutting
reinforcement etc. complete with stacking the
material as directed.
* Upto 0.2 meter thickness (By Manual) 1551.00 Smt. 72.15
14.00 Providing, laying, spreading and compacting
graded stone aggregate to wet mix macadam
specification including premixing the Material
with water at OMC in mechanical mix plant
carriage of mixed Material by tipper to site,
laying in uniform layers in subbase / base
course on well prepared surface and
compacting with vibratory roller to achieve the
desired density as per MoRTH clause 406. 388.00 m3 1146.95
15.00 Construction of Valve chambers in brick
masonary, locally available in C.M. 1 :
foundation concrete 150 mm thick in C.C.
1:4:8 of trap metal size 25 mm to 40 mm thick,
inside cement plaster in C.M. 1:3 and cement
pointing outside in C. M. 1 :3 & top cover of
precast RCC slab 100 mm thick upto 1 mt.
depth from G.L. but excl. cost of excavation
and refilling. With cast in situ RCC slab in two
piece ,with 23 mm thick brick masonary wall
* 0.9 x 0.9 mt. and 1.0 mt. deep chamber 4.00 No. 8898.70
15.01 * for 1 m. extra depth
16.00 Making connection to the ex. M.H. in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipe at any
convenient time. All damaged work shall be
well repaired as per instructions etc. complete.
* For 150 to 300 mm dia. pipe 2.00 No. 1352.68
17.00 Drilling of Horizontal bore hole for watr main
pipeine under the railway / road tracks in all
strata with required length including fixing of
MS casing pipe of suitable size and thickness.
Rate includes the cost of Drilling of bore hole.
Casing pipe an welding pushing etc complete
but excluding the cost of water main, valves
and other items. Entire work should be as per
approved drawing and as pe instruction of
railway / road authority for following diamter
of Bore hole for MS pipe.
* Horizontal drilling 300 & MS casing pipe
House Service Connection
Item Tender Rate Amount
Item Description Quantity Unit
Connection from House to Chamber
1.00 Providing and supplying ISI marked
only Standard length Stoneware pipes
in standard lengths of following class
and diameter including all taxes,
insurance, transportation, freight
charges, octrol, inspection charges,
loading, unloading, conveyance to
departmental stores, stacking etc.
complete. (IS-651/1989)
Stone-were pipe
2.00 Lowering, laying and jointing Stone
Ware pipes of following diameters
with cement joints in C M. 1:1
proportion in proper position, grade
and alignment as directed by Engineer-
in-charge including conveyance from
stores to siteof work, Jointing material.
Stone-were pipe
* 100 mm dia. class A 7910.00 m 66.70
3.00 Excavation for pipeline trenches and
making hole in brick masonery incl.
All safety provisions using site rails
and stacking excavated stuff upto a
lead of 90 mtrs, Cleaning the site etc.
complete for lifts and strata as
* In Soft Soil 3557.24 Cum 102.35
3.01 * In Soft Rock (Concrete Floor)
3.02 * Hole in Brick Masonary
4.00 Providing & Fixing S.W. Gully trap
with C.l. grating brick masonary
chamber & water tight C. cover with
frame of 300mm x 300mm size Inside
with standard weight.
Square Mouth trap
* 150 mm x 100 mm Size P to R type 1130.00 No. 1168.13
5.00 Refilling the Pipeline Trenches incl.
Ramming, watering, consolidating and
disposal of surplus stuff as directed
within a radius of 3 KM. 2486.00 Cum 25.30
6.00 Providing and laying cement concrete
flooring 1:24 (1 cement: 2 coarse sand:
4 graded stone aggregate 20 mm
nominal size) including water proofing
compound finishing with a floating of
neat cement slurry etc. complete laid in
one layer finished including necessary 4746.00 Smt. 212.84
curing at bottom of UGT. Average
7.00 Excavation for foundation for loose
and soft soll including sorting out and
stacking of useful materials and
disposing of the excavated stuff up to
50 meter lead. 1130.00 Smt. 69.00
8.00 Filling with available excavated earth
(excluding rock) in trenches, plinth,
sides of foundation in layers not
exceeding 20 cm in depth
consolidating each deposited layer by
ramming and watering. 565.00 Smt. 80.71
9.00 Providing and laying ordinary cement
concrete 1:3:6 (1 cement : 3 coarse
sand : 6 hand broken stone aggregate
12 mm to 25 mm nominal size) and
curing etc. complete (with form work).
* For Foundation and in plinth below
flooring 169.50 Smt. 3972.00
10.00 Brick masonry in cement mortar (1:5)
using common burnt clay building
bricks having crushing strength not
less than 35kg/csmt including
scaffolding,curing, etc. complete for
walls, parapets, etc. at all levels. 508.50 Smt. 2815.80
11.00 CI Cover with Frame 300mm x 300mm
12.00 Interior plain faced 15 mm thick
cement plaster (1:3) with floating coat
of neat cement slurry on Underneath of
top of chamber where specified on
drawings at all levels including
scaffolding, curing, etc. complete. This
rate shall include moulding where
specified. The rate shall include 2%
approved quality water proofing
compound (by weight) of cement. 1130.00 Smt. 166.56
Connection from House Chamber to
Providing and supplying of Class SN8
Structured Wall polyethelene Piping
systems (Pipe with online/offline
coupler and elastomeric sealing ring)
with non-smooth External Annular
Corrugated and Smooth Internal
Surfaces (Double Wall) for non-
pressure underground Sewerage &
Drainage application as per EN:13476-
3 includ ing all local and centra l taxes,
transportation, freight charges, octroi,
inspection charges. loading, unloading,
conveyance to the departmental stores
etc. complele.(ID Dia)
14.00 Constructing Slab type House
Connection Chmaber of Following size 1130.00 No. 4089.00
incl. Excavation, refilling, PCC (1:2:4)
finished 15 mm th cement plaster
inside & outside in C.M. 1:3 finishing
with cement slurry ,P/F 4 mm Dia M.S.
steel PVC coated steps 30 cm c/c at
cm staggered Masonry in C.M. 1:5,
R.C.C. slab in C.C.1:1.5:3 including
centering and reinforcement but
excluding cost of manhole seat cover
15.00 Excavation for pipeline trenches
including all safety provisions using
site rails and stacking excavated stuff
upto a lead of 5.00m, clearing the site
etc.complete for lift and strata as
In all sorts of soil and soft murrum 7815.62 m2 102.35
16.00 Lowering, laying and jointing of class
SN 8 structured wall (External Annular
Corrugated & Smooth Internal surface)
Polyethylene Piping and fittings with
the help of coupler (on line I off line)
attached with one end of pipes, sliding
over the elastomeric sealing rubber
ring placed on the specified valley of
the corrugation at the spigot end,
lowering the same into the trench at all
level, laying on the lower bedding
(constructed at bottom of trenches) at
prescribed gradient, depth &
alignment, testing the water tightness
of the joints, ensuring the continuity
tests of specified pipe segments etc.
complete as per drawing,specifications
& detailed engineering, including
carriage of pipes & fittings from site
stacks to the place of laying etc. as per
direction of Engineer-in-charge.
17.00 Refilling the pipeline trenches
including ramming, watering,
consolidating disposal of surplus stuff
as directed within a radius of 3 km. 7707.00 m3 25.30
18.00 Excavation for foundation upto 1.5 m
depth including sorting out and
stacking of useful materials and
disposing off the excavated stuff upto
Loose or soft soil. 4068.00 m2 69.69
19.00 Providing and supplying in standard
length ISI mark rigid unplasticised
PVC pipes suitable for potable water
with ringfit joint including cost of
rings, as per IS specification no.
4985/1988 including all local and
central taxes, transportation, freight
charges, octroi, inspection charges,
loading, unloading, conveyance to the
departmental stores and including cost
of jointing meterial etc. complete.
1.One coupler / ring shall be provided
with each full length pipe cost of which
is included in rates below.2. 3%
(Three) Discounted rate to be consider
for Coupler jointed pipe3. Rate for
PVC Resin as Rs. 91739 (Price
Without GST) , Test Pressure
20.00 Filling available excavated earth
(excluding rock) in trenches. plinth,
sides of foundations etc. in layers not
exceeding 20 cm.in depth
consolidating each disposited layer by
ramming and watering. 3960.67 m2 79.33
Mechanical, Electrical & Instrumental Work in Kheda Camp Pumping Station and Vithalpara
Pumping Station
Item Description Quantity Unit Rate
MECHANICAL WORK
1.00 SUBMERSIBLE NON-CLOG PUMP
Supply, Installation, Testing and
Commissioning (SITC) of Submersible
NC Pump-Motor set suitable for sewage
application with semi-open or enclosed or
suitable type Impeller & wear Rings in
CF8M with CI FG 260 Casing & casing
cover, SS 410 shaft & with motor suitable
for 3-Phase, 415 V, 50 Hz., AC induction
Air filled dry type submersible motor of
mini. rating as specified having max.
1500 RPM sync. speed, insulation Class
'F' With temp. rise limited to class B and
IP-68 protection.
The scope shall include all required
accessories viz. automatic coupling
device, SS-304 heavy duty & of suitable
size double guide pipes of length to suit
the sump height with required supports,
SS-304 or suitable stainless steel grade
Chain with shackles (shall be with dual
hook / shackles of 100 mm or suitable
higher size at app. every 1.5m C-C
distance) & of length as per sump height
+ min. 3m, Submersible Power & control
cable (copper flexible & stranded type
conductor of reqd. cores & size for each
pump motor set) & length of sump height
+ min. 5 m long each run with necessary
electrical termination connection at
junction box/starter panel and RCC
foundation blocks for auto coupling &
delivery bend, PMU etc. complete as per
IS and Specification and also including in
scope any other parts/accessories / fittings
required to complete the work in all
respects & satisfactory operation of pump
Pump Capacity: 35 m3 / hr.,
Motor Rating: min. 5.5 kW (or higher
rating as reco. by pump mfg.)
Overall Efficiency at Duty- min. 35% 2.00 Set 189463.00
SITC of CI/DI Double Flange Manually
operated Sluice Valve as per IS 14846 PN
1.0 of following sizes with SS 304 seat
rings, SS spindle with all hot dipped
galvanized hardwares, bolts, nuts &
washers, gaskets including all taxes, etc.
complete as per IS and Specification.
* 100 mm NB (At delivery of each Pump
& 1 no. at Header) 3.00 No. 4002.00
2.01 SITC of Non-slam, flanged, single door,
swing type Non Return Valve conforming
to IS 5312, Part 1 having pressure rating
PN 1.0, having CI/DI body and door,
CF8M seat rings along with all necessary
hardwares and complete as per IS and
* 100 mm NB (At delivery of each Pump) 2.00 No. 5787.00
3.00 MS PIPES & SPECIALS:
Supply, Gas cutting of pipe, Fabrication,
welding, Installation, testing and
commissioning of MS pipe & Specials,
reducer, expander, bend, Y-Joint, TEE
etc. conforming to IS 3589 & flanges
confirming to IS 6392-PN-1.0, fabricated
from MS. plate with necessary supports &
anchoring. Pipe fabricated from MS plate.
(Excluding supply of flange) as per specs.
and complete in all respect.
* 100 mm NB x min. 4.0 mm Thk 30.00 Rmt. 943.33
3.01 Supply, Welding, Installation, Testing &
Commissioning of MS flat machined
faced flanges confirming to IS 6392 &
drilled as per IS-1538 with drilling off
centre bolt holes and flange thickness as
per PN 1.0 including cutting & welding.
* 100 mm NB - Drilled 12.00 No. 800.00
3.02 * 80 mm NB - Drilled (or as per actual
pump del. size) 1.00 No. 690.00
3.03 * 100 mm NB - Drilled Blind. 1.00 No. 570.00
4.00 Flanged Joints of Pipes, Fittings and
Supply, Installation, Making of Flanged
CI / GI / MS Pipes, Fittings and Specials
Joints with all jointing materials, rubber
packing, nut bolts, labour etc.for
complete connection.
5.00 MONORAIL EOT WITH ELECTRIC
SITC of Electrically Operated Chain
Hoist & Electrically operated Trolley,
suitable to operate on Mono Rail Girder
having motorised motion, manufactured
as per IS:6547-1972-Class-II & IS-3177-
Class-II, complete with brake, chain-gear,
motors, safety device, pendant push
button, starter panel, cables from motor to
starter panel and all other required
accessories like limit switches, power
supply system (Fastoon cable type),
fasteners, epoxy painting, etc. tested for
overload as per IS and as per
specifications, complete in all respect.
* Capacity: min. 1.0 Ton. (For Subm. NC
Lift: min. 10.5 m or as per site req. 1.00 No. 150880.00
Bay Length: min. 5.8 m or as per site req.
(w/o MONORAIL GIRDER & MS
supporting structure)
Note: Minimum as specified capacity or
higher as per requirement such that EOT
with ECH capacity is min.1.25 times of
the pump /motor OR single heaviest
component to be lifted within pump
5.01 * Capacity: min. 1.0 Ton. (For Manual
Lift: min. 6.2 m or as per site req.
Bay Length: min. 3.1 m or as per site req. 1.00 No. 150880.00
6.00 SLUICE GATE
SITC of Manually operated C.I. Thimble
mounted Sluice Gate conforming to
AWWA C 501 or IS: 13349 - 1992 Class
- 1 with rising spindle, single faced, wall
thimble mounted, handwheel,
Conventional Type Closure, flange back
frame, headstock, Spindle with supports
brackets having length as specified or to
suit site condition, suitable for seating as
well as unseating water head, complete in
* 300 mm X 300 mm - approx. 3.15 m
spindle length (At Inlet Pipe) 1.00 No. 190440.00
7.00 “J” TYPE MANUAL MESH SCREEN
SITC of “J” Type Manual mesh Screen
made of SS 304 material having round
bars of size 9 mm dia. with clear bar
opening as specified here below, suitably
welded in frame of equal Leg SS angle of
size 50 mm x 50 mm x 6 mm thick & shall
also including followings:
SS perforated Screening Material
Collection Box/trough at the bottom end
of Screen fabricated from 3 mm thk. SS
sheet, the screen shall be suitable to slide
complete through rollers between guide
passage of MCP 100, embedded/ fixed in
wall on both sides of RCC wall up to top
of chamber with all necessary hardware,
SS nuts, bolts & washers, sacrificial Brass
lugs on sides, min. two lifting lugs/hooks
& SS lifting chain having intermediate
link/chain of 300 mm dia. at every 1.5 m
distance with shackle, etc. complete in all
respects and provided with 1 set of
cleaning rake with screen, complete as per
specification and complete in all respect.
* Screen Size: 550mm (W-or to suit site
requirement) x 600mm (H)
Screening Box/trough size: 500mm (W-
or to suit site requirement) x 100mm (H)
Opening: 50 mm x 50 mm sq. opening
(Note: Screen suitable for 600 mm wide
chamber or to suit site requirement) 1.00 No. 285280.00
8.00 SUBMERSIBLE NON-CLOG PUMP
at Machine Manhole near STP (for
Bhatha Network)
Supply and testing of Submersible Non
Clog Portable Dewatering Pumpset with
C.I. casing & CF8M impeller, 25 m
flexible PVC hose pipe of pump delivery
size, rated for 6.0 kg / cm2 presure, 15 mtr
SS lifting chain, 20m pair of cable for
motor to starter panel, suitable for 3Phase,
415 V, 50 Hz AC supply and min. motor
rating as indicated here below, Switch-
Starter panel with PMU suitable inter lock
for winding protection, moisture
controller for fault detection and auto stop
facility, with buit-in level switch for dry
run protection and auto stop facility, 20 m
suitable size power supply cable to starter
panel, GI/CI pump stool and other
required accessories for wet well.
Capacity : 10 m3 / hr.
Motor Rating: Mini. 2.2 kW (or higher
rating as reco. by pump mfg.) 1.00 No. 148748.00
9.00 Providing, Supply of Structure Steel at
site of work with freight, loading,
unloading carting, etc. including all taxes
and duties complete such as joints,
channels, angles, Iron Rails,
ISA/ISMC/ISMB/MS flat, Plates,
Chequered plates (below 8mm thickness)
for cable trench etc. required for support
structure of all Electro-mechanical
equipment, piping, etc. for support on
floor / wall / beam / brackets etc. as per
tender and IS. 500.00 Kg 64.84
10.00 Labour Charges for lowering, laying,
fixing with fabrication various size
section of MS such as joints, channels,
angles, Iron Rails, ISA/ISMC/ISMB/MS
flat, Plates, Chequered plates, for cable
trench etc Complete with two coats of red
oxide and two coats of approved colour
shade of epoxy paint as per relevant IS
and as per specification. 500.00 Kg 11.37
ELECTRICAL WORK
11.00 TPN MCCB (For LT Service Obtaining
SITC of 250A TPN microprocessor
MCCB (50kA) with O/L, S/C & E/F
protection with Extended rotary handle,
Terminal spreader, Auxiliary change
over & Trip contact, with Outdoor
Enclosure with canopy 2mm thick
Single/double door & Wall mounted/
stand mounted as per site requirement
(with incoming & outgoing cable entry at
bottom )with Cable end boxes with RYB
indicating lamp, Digital voltmeter, VSS,
ON,OFF & Trip indicating lamp etc as
per Power supply company requirements
& location. Including all civil works for
fixing of panel on wall.
(Wall mounted at Location as per PSC
11.01 MEDIUM VOLTAGE PANEL BOARD
SITC of PMCC Panel (50kA), 1.00 Set 208000.00
compartmentalized, Stand mounted,
operating height maximum 1800/1900
mm, Extensible on both ends, suitable for
Manual & Auto operation -Local &
through PLC/SCADA operation as per
site conditions complete in all respects as
per Tender SLD / Specification / IS and
including following as minimum:
(1) One no. Incoming feeder FP 250A
Microprocessor MCCB (50kA), LSIG for
I/c with Digital Voltmeter, Voltmeter
selector switch, Digital Ammeter,
Ammeter selector switch, Digital PF
meter, MFM with RS-485 of Class-0.5,
Indicating lamps R,Y,B,On,off,Trip,
3nos. 250A/5A, Cl.-0.5 metering CT, CL
0.5 CT for APFC relay etc. Constant
voltage/control voltage transformer
1500VA, 415V/230V AC, with tapping
+/-5% in steps of 2.5%, 32A DP MCB.
(1.1) Surge protection device, 3P + N,
Type 2 for lightning/surge protection.
(2) 250A TPN Main Aluminium busbars.
(main busbars size with current density
(3) DIRECT ONLINE (DOL)-5.5 KW
Starter Feeder (SUBM.): 2 Nos:
Each starter comprising of 9-13A TPN
MPCB with adjustable overload &
adjustable short circuit, 25A contactor,
Digital Ammeter, ASS, 32A/1A, Cl.-1.0,
10VA CT, Start, E-Stop, Reset push
Button, ON, OFF, trip Indications etc.
(4) 32A TPN MCB FEEDER : 4 NOS.
2 nos. 32A 'C' curve TPN MCB feeders (1
no. for ECH at P.H, 1 no. ECH at Screen,
1 no. for portable de-silting pump, 1 no.
Spare) with indicating lamp etc.
(5) 32A FP MCB FEEDER : 3 NOS.
3 nos. 32A 'C' curve FP MCB feeders (1
no. for Lighting, 2 nos. Spare) with
indicating lamp etc.
(6) APFC separate cubical compartment
(minimum 7 KVAr) having 1no. 32A
TPN Thermal magnetic MCCB 50KA
with adjustable overload and adjustable
short circuit, 6 step APFC relay with RS
485, 1no. 32 A/5A, Cl.-0.5 APFC CT,
nos. 2 kVAR capacitor with 16A TP D
curve MCB, 1 no. 1 kVAR capacitor with
16A TP D curve MCB with capacitor
Duty Contractor A/M switch, On delay
timer etc. Complete in all respects as per
Specification, IS & SLD.
(7) Multiplication relay as required for
dry run protection of pumps.
NOTE: 1). All MCCB shall be 50KA, Ics
= 100% Icu, inbuilt protection with adj
O/L and Adj.S/c (LSIG for MP MCCB),
Extended rotary handle, Terminal
spreader,Auxiliary Change over contact
and trip contact as required. 2) All MFM,
ACB, Soft Starter,MPR,Temp.Scanner
etc shall be with inbuilt RS
11.02 ICP Cubical a part of PMCC Panel as
ICP cubicle compartment as a part of
PMCC (as per SLD) panel with required
input / output for field instruments
interfacing at terminal strip& comprising
(a) Door mounted 1 no. Process indicator
with 4 nos. relay output for start pump at
high level and stop at low level for Level
transmitter ,UPS power ON Indication,
(b) Required separate isolation switches
(DP MCB only) for incoming 230 V AC
power mains from UPS & outgoing
power feed to 1 no. Process indicator ,
Nos. Multiplication Relay (1 no. 1 input +
2 Output) for Dry run protection of Pump
at low-low level ,etc.
(c) Offline type UPS of suitable rating
(min. 250 VA with 15-20 min. backup
time ) mounted within cubicle on main
incoming power line with required
isolation device (DP MCB) & outgoing
feed to power supply ofinstruments.
(d) Any other as required to complete the
work and meet the tender
requirement/specification. 1.00 No. 40000.00
12.00 LOW VOLTAGE (LT) CABLES
Supply, laying, testing and
commissioning of 1.1 kV,
A2XFY(X)/2XWY(X) XLPE insulated
(IS 7098) Al. / Cu stranded conductor,
Extruded innersheath cables as per
specification & IS.
The cable when laid outside the building
shall be laid underground in excavated
trench, as per specified method and shall
be laid in prepared trench/ on cable tray
when laid inside the building.
* SITC of 3.5C x 240 sq. mm.
A2XFY(X) Cable (1 run for MCCB to
PMCC panel) 15.00 m 972.34
12.01 * 4C x 6 sq. mm. A2XFY Cable (For
nos. street light) 40.00 m 107.85
12.02 * 4C x 2.5 sq. mm. 2XWY/2XFY Cable
(For 1 no. EOT with ECH at P.H, 1 no.
EOT with ECH at Screen, 1 no. portable
de-silting pump) 100.00 m 244.80
12.03 * Single core 95sq. mm. PVC insulated
circular unsheathed copper conductor
flexible Cable (For Power supply
Metering Panel to I/c MCCB Unit) 20.00 m 787.46
13.00 CABLE END TERMINATION AND
SITC of Double compression weather
proof type Ni-plated brass cable glands
and crimping type Bimetallic lugs /
sockets with necessary tools and
equipments as specified in specifications
and IS. The glands and lugs / sockets
shall be suitable for cable size and type
mentioned below & as per specifications.
1) Earthing the glands and armouring
with earthing clamp and jumper and also
connecting to common earth bar.
2) The job also includes, if necessary,
supply & fixing of extension busbar of
same material on MCCB or panel board
terminal / connector to connect more than
one no. of parallel cables or to connect
higher size cable to lower size unit. The
job also includes earthing the glands and
armour of the cable with common earth
bar or flexible copper mesh.(Cable
termination qty. shall be as per site
* 3.5C x 240 sq. mm. A2XFY(X) Cable
(1 run for MCCB to PMCC panel) 2.00 No. 483.60
13.01 * 4C x 6 sq. mm. A2XFY Cable (For,
nos. street light) 4.00 No. 51.36
13.02 * 4C x 2.5 sq. mm. 2XWY/2XFY Cable
(For 1 no. EOT with ECH at P.H, 1 no.
EOT with ECH at Screen, 1 no. portable
de-silting pump) 6.00 No. 57.35
13.03 * Single core 95sq. mm. PVC insulated
circular unsheathed copper conductor
flexible Cable (For Power supply
Metering Panel to I/c MCCB Unit) 10.00 No. 42.80
14.00 CABLE TRAY
SITC of G.I. Ladder/ Perforated type with
top cover medium duty (2mm thick)
Cable Tray with necessary bends, tees,
coupler plate and clamps for fixing. All
material shall be Hot dip galvanised as per
150 x 50 mm - Ladder type 30.00 m 278.18
14.01 Making Trench/ excavation in soft soil of
suitable width and of depth (minimum
750mm depth (LT) & 1000mm for HT)
for laying cable/ DWC pipe and back
filling the same and making the surface as
normal ground as per IS & Tender
Specification/Drg. (For laying of LT
cable) 20.00 m 46.22
14.02 Cable Trench, Laying & Installation of
Cable: Making cable trench in soft soil of
suitable width of 90cms deep for laying
cable, Sand cushioning and brick
protection on sides and on top all over the
run and back filling the same and making
the surface as normal ground as per IS &
Specification. (For laying of LT cable in
ground) 20.00 m 46.22
15.00 CHEMICAL EARTHING SYSTEM
SITC of Maintenance free chemical
earthing with earthpit of minimum bore
size dia. 225mm Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as
per IS-3043:1987 /Tech spec. made of
corrosion free Hot dip Galvanised (min
150 Microns) Pipes having Outer pipe
dia of 76 mm , Inner corrosion free Hot
dip galvanised (80 to 100 micron) pipe
dia of 26 mm with copper flat strip type
connection terminal 14mm dia with
constant ohmic value surrounded by
highly conductive corrosion resistant
chemical compound with high charge
dissipation suitable for electrical
installation & 3Mtr. length of Pipe with
two nos. 25Kg. bag of Back filling
compound. (2nos. for PMCC panel & all
elect. Equipments)
NOTE: Earthing Resistance value & date
shall be painted on the chamber cover. 2.00 Set 7093.97
15.01 SITC of pipe type earthing having
cms long and 2.5 cm dia. Galvanised iron
pipe with coupling and buch buried in
specially prepared earth pit complete with
necessary 8 SWG earth wire (For 2 nos.
for gate light, 2 nos for street light) 4.00 No. 368.05
15.02 SITC of 50 mm (w) x 6 mm (T) etc. sizes
as required, HOT dip galvanized GI Strip
including supply & fixing using GI
spacers, saddles when laid inside the
building and inclusive of excavation &
refilling of earth when laid outside the
building & interconnection with earth pit
& all electro-mechanical equipments.
(50 x 6 G.I Strip wt.2.3 kg/m, 2.3 x
15.03 Supply, laying and erection of 25 mm (w)
x 3 mm (T) etc. sizes as required, HOT
dip galvanized GI Strip including supply
& fixing using GI spacers, saddles when
laid inside the building and inclusive of
excavation & refilling of earth when laid
outside the building & interconnection
with earth pit & all electro-mechanical
(25 x 3 G.I Strip, 0.6 Kg/m, 0.6 x 20 Mt.=
15.04 SITC of HOT Dip Galvanized iron strip
(8 SWG G.I Strip, 0.103 Kg/m, 0.103 x
16.00 INTERNAL WIRING
SITC of Mains & outlet points wiring
with 1.1 kV grade FRLS PVC insulated
ISI marked flexible stranded copper
conductor wires with medium class min.
25mm. dia. Rigid PVC pipe and
accessories to be erected concealed in / to
be run on surface / wall / ceiling with
following sizes as mentioned below. The
unit rate wirings shall be with connector,
PVC junction box, wires, holder, ceiling
rose, angle holder, switch, sockets, switch
board, brass chromium / cadmium plated
machine screws, phase and neutral wires,
green Earth continuity wires etc. as
required to complete wiring from LDB
panel to the final outlet termination
points. The wiring shall be as per
IS:732, IS:4648 and as per tender
specification / IS.
* SITC of Mains wiring with 3 wire
16.01 * SITC of Mains wiring with 3 wire
16.02 * SITC of Mains wiring with 4 wire
16.03 * SITC of Mains wiring with 4 wire
16.04 SITC of Point wiring for Light / fan / Bell
/ Primary Point with 2 nos. 1.5 sq. mm &
earth wire of 1.5 sq. mm (green) both are
of ISI marked 1.1 kv grade FRLS PVC
insulated multistrand copper wires, pipe
to be erected concealed in flushed on wall
/ ceiling, complete with 6A Tissino Type
ISI marked flush type switch / bell push
& accessories erected on metal / PVC Box
covered with 3 mm thick PC
(Polycarbonate) / Acrylic sheet with
necessary lamp holder / ceiling Rose / H.
D. connector as directed with medium
class Rigid PVC pipe & accessories. 9.00 No. 282.46
16.05 SITC of 6A independent Plug with 2 nos.
1.5 sq.mm Cu. Mains size wiring &
earthwire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires with
medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling,
complete with ISI marked 3 / 5 Pin socket
and tissino type switch erected with earth
continuity connection erected on Metal /
PVC box covered with 3 mm thick PC
(Polycarbonet) / Acrylic sheet. (1 no. for
LT Room cum P.H.) 1.00 No. 248.22
16.06 SITC of 6/16 A independent Plug with
nos. 4 sq.mm Cu. Mains size wiring &
earthwire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires with
medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling,
complete with ISI marked 3 / 5 Pin socket
and tissino type switch erected with earth
continuity connection erected on Metal /
PVC box covered with 3 mm thick
PC(Polycarbonet) / Acrylic sheet. (1 no.
for LT Room cum P.H.) 1.00 No. 487.88
16.07 SITC of One 300/380 mm dia. Ex fan 16A
independent Plug point near Ex. Fan with
2nos. 4 sq.mm Cu. Mains size wiring &
earthwire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires with
medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling,
complete with ISI marked 3Pin socket
and tissino type switch erected with earth
continuity connection erected on Metal /
PVC box covered with 3 mm thick
PC(Polycarbonet) / Acrylic sheet. Plug
point shall be near Ex.Fan.
(1 no. at L.T Room cum P.H) 1.00 No. 487.88
16.08 SITC of 380 mm sweep 1400 R.P.M
exhaust fan, capacitor type, having double
ball bearing, M.S.blades, mounting
frame, forearms, suitable to operate on
230 V, 50 HZ AC supply conforming to
IS: 2312. Fan shall be painted with epoxy
grey colour controlled by one 6 A flush
type switch on board and 6A plug point
near Ex. fan.(1 no. L.T Room cum P.H) 1.00 No. 3081.36
16.09 SITC of Single Phase 20A 3 Pin Metal
clad Industrial Type Socket with plug top
and 20A SPMCB, suitable for flush
mounting, in 16 SWG MS box of suitable
size and covered with 3 mm thick
electrical grade hylam sheet or equivalent
ISI marked Electrical grade Bakelite sheet
and earthing with 2.5 sq.mm insulated
copper wire run inside the conduit
including interconnections etc. complete
(1 no. for LT Room cum P.H) 1.00 No. 820.00
16.10 SITC of Sheets steel powder coated
weather proof enclosure suitable for as
well as with incorporating One no. 32A,
415V MCB Four Pole for Motor &
Inductive load (C Curve) having 10 KA
breaking capacity & confirms to IS:
(For 1 no. for EOT with ECH at pump
house, 1 no. EOT with ECH at Screen) 2.00 No. 663.35
17.00 LED LIGHT FIXTURES & LIGHTING:
SITC of Indoor wall mounting 20 Watt or
up to 25% higher wattage LED 4 feet
Tube Light indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as
a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA
polyester powder coated and high U.V. &
corrosion resistance with diffuser and/or
Polycarbonate optics with company
120 to 300 V, Power Factor more than
CCT 4000 K to 6500 K, Uniformity ratio
Luminaire efficacy > 85 lumens/watt
LED driver efficiency > 85 %
(Each fitting required LM-79 & LM-80
* Tube Light with integral / non-integral
driver, Surge-4KV,IP-20, 4 feet, Cat-III
(2 nos. at LT Room cum P.H.) 3.00 No. 400.58
17.01 * SITC of 7 watts LED Lamps integral
type, cool white with PC diffuser suitable
for B22 LAMP holder (For 1 no. at LT
17.02 SITC of 40W LED Surface / Wall
mounted LED Flood Light fittings with
High power White LEDs wattage of
1Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast
aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and
Polycarbonate optics/ lenses with
company mark/name engraved or
120 to 300 V,Power Factor more than
Uniformity ratio > 0.45, Luminaire
efficacy > 85 lumens/watt . LED driver
efficiency > 85 %.
( Each fittings required LM-79 & LM-80
(IP-65), Surge - 4KV Cat-III
For Indoor use: 1 no. 1.00 No. 7164.15
17.03 SITC of 'B' class galvanised iron pipe
mm outside dia 45 cms long duly welded
on 20 cms x 20 cms x 3 mm thick M.S.
base plate, erected on wall or corner for
mounting luminaries with necessary
hardware materials duly painted for wall
mounting indoor flood light fixtures on
Wall of Buildings & post top lantern. 7.00 No. 556.36
18.00 EXTERNAL LIGHTING (Flood
SITC of 70W LED Wall mounted LED
Flood Light fittings with High power
White LEDs wattage of 1Watt and above
assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free
High pressure die cast aluminum housing
with smooth finish powder coated and
heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses
with company mark/name engraved or
120 to 300 V,Power Factor more than
Uniformity ratio >0.45, Luminaire
efficacy> 85 lumens/watt . LED driver
efficiency > 85 %.
( Each fittings required LM-79 & LM-80
(IP-65), Surge -4KV Cat-III
For Outdoor use: (4 nos. for area lighting) 4.00 No. 8388.14
18.01 SITC of 40watt, Cat-III Post Top Lantern
LED fitting comprises of 650 MM TOP
Diameter, 120 degree beam angle with
Nos. Supporting Ribs and with 0.5mt. G.I.
fitting pipe with complete painted with
one coat of Red oxide / PU base primer
and two coats of Aluminium / PU paint
for Post of lenturn pipe etc. (for Gate
light) 2.00 No. 6659.15
18.02 EXTERNAL LIGHTING (STREET
SITC of Street Light Pole, steel tubular
swaged type, 7.5 meter long with single
arm & M.S.base plate with pipe cap and
over hung 1.5 m long having dia to suit
the socket of 240V LED street light
fixtures. Street light pole unit rate shall be
with (i) IP 65 SMC box of size 20 x 15 x
15 cms. with MCB & terminal strip inside
the box with hinged/sliding door (ii)
50mm dia, B class GI pipe bracket
min.1.5mtr long for Incoming & outgoing
cable (iii)MS Cable Clamp of 25 x 3mm
(iv)SITC of 1.5 Mtr.single Arm bracket
of medium duty MS pipe of 4.2 cms. Out
side dia complete with suitable sleeve
tubing 45 cms. long of required size of
pole top etc. and having spread of 1.5.mtr.
length with 110 deg.(v) Complete painted
with one coat of Red oxide / PU base
primer and two coats of Aluminium / PU
paint for Pole,Arm, pipe etc. 2.00 No. 9881.74
18.03 SITC of 70 W LED Street light fittings
with High power White LEDs wattage of
1Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast
aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and
Polycarbonate optics/ lenses with
company mark/name engraved or
120 to 300 V,Power Factor more than
Uniformity ratio >0.45, Luminaire
efficacy> 85 lumens/watt . LED driver
efficiency > 85 %.
( Each fittings required LM-79 & LM-80
Street Light (IP-65), Surge -4KV, 70 watt
Cat-III 2.00 No. 8234.07
18.04 SITC of M-20 / 1:2:4 cement concrete
foundation for Street light pole & 70 %
PCC from bottom including excavation
for the pole of size 60 x 60 x 120 cms.
Deep in below ground level with plinth of
45 cms x 45 cms(or 45 cms dia x 45 cms)
high upper ground level with necessary
curing and finishing in approved manner. 2.00 No. 1112.71
19.00 SAFETY ACCESSORIES
SITC of following safety accessories
complete with necessary fixing brackets,
other accessories and tools etc. as
required to complete the job.
Supply & Erecting carbon dioxide (CO2)
fire extinguisher of 6.5kg capacity with
necessary clamps made from 50 x 6 mm
M.S. Flat with nut & bolts grouted in wall
(1 no. for LT Room cum P.H.) 1.00 No. 8670.59
19.01 Supplying of standard first AID box with
antiseptic cream, medicine for use on
wounds due burn, crepe bandage, guage
bandage, medicated ready to use bandage
(Band-aid) adhesive tape for medicinal
user, scissors, antiseptic solution (Savlon
or similar) etc. (All above contents shall
be of standard makes)
( 1no. For LT Room cum P.H) 1.00 No. 299.58
19.02 Supply & fixing of printed instruction
(First Aid) Chart both in English and
Gujarati and duly framed with front
glasses, for treatment of person suffering
from electric shock. (1 no. For LT Room
19.03 Supply and fixing of 20 W fluorescent
lamp operated emergency light with
maintenance free battery for 3 hours
operation during mains power failure.
(for 1no. LT Room cum P.H.) 1.00 No. 2540.00
19.04 Supply and laying of Synthetic Insulating
Mat of Class - A of min. thickness 2mm
as per IS:15652 and with good electrical
insulation property for 1.1KV/3.3KV as
per site requirement. (for LT Panel) 2.00 m2 1027.12
19.05 Providing pair of rubber hand gloves ISI
make suitable for working on 22 KV
supply 1.00 No. 218.26
20.00 LIASONING CHARGES FOR
Power Liasoning Charges for obtaining
N.O.C from Electrical Inspector /
Statutory authority for Power / Ele.
Installation. (Fees shall be paid by
tenderer for obtaining N.O.C. from
Electrical Inspector / Statutory authority
on behalf of client and shall be
reimbursed on submission of original 1.00 LS 15000.00
receipt to Client).
Liasoning Charges shall include
preparing required attested documents &
drawing for obtaining NOC on behalf of
client (Applicable Fees / deposits shall be
reimbursed by Client).
INSTRUMENTATION WORK
21.00 PRESSURE MEASURING SYSTEM
Supply, installation, testing &
commissioning of Diaphragm Type
pressure guage having 150 mm dial with
necessary fittings/accessories in SS
(manifold valve, nipples etc.) complete in
all respects and as per specs.
Range : 0 - 2.1 Kg/cm2 (at each pump
discharge line) 2.00 No. 5522.00
22.00 LEVEL MEASURING SYSTEM FOR
Supply, installation, testing and
commissioning of Ultrasonic type Level
Transmitter with remote type transmitter
with 10meter cable between Sensor and
Transmitter along with all required
accessories, Weather proof enclosure for
transmitter for outdoor application,
mounting stand , etc. complete in all
respects as per specification and having
following measurement ranges for liquid
(Water) application:
Meas. Range: upto 10 m (at sump ) 1.00 No. 59436.00
22.01 Supply, installation, testing and
commissioning of Float type Level
Switch along with 10 mtr. Cable and WP
Junction Box (at sump for dry run
protection of pumps through relay
multiplication in PLC), etc., complete in
all respects and as per specification.
Meas. Range: upto 10 m (at sump ) 1.00 No. 12802.00
23.00 ELECTRO MAGNETIC FLOWMETER
Supply, installation, testing and
commissioning of Full Bore
Electromagnetic flow meter comprising
of IP-68 Sensor , IP-66 remote type
transmitter with 20 m cable between
sensor and transmitter along with all
mounting accessories, Weather proof
enclosure for transmitter, hardware,
mounting stand, etc.
as per specification and to complete the
work in all respect as per site condition
necessary connection with pipe and shall
have following size.
Meter Size: 100mm (At Pump common
Pipe Size : 100 mm 1.00 No. 65837.00
24.00 INSTRUMENT CABLE &
Supply, Laying, Installation, Connection,
Termination, Testing & Commissioning
of Instrument Cables as per specs.
The unit rate shall include
a) Supply, loading & unloading of the
cable at site from store.
b) Shifitng of cable from site store to
place of installation.
c) Fixing of cable clamps, brackets,
supports, route markers etc. where ever
required to fix the cables safely.
d) Excavation, back filling and levelling
of ground alongwith laying of fine sand,
protection bricks and other necessary civil
material for laying cables outside the
f) Testing and submission of sketches &
reports of all the cables laid.
25.00 CABLE END TERMINATION AND
Supply, fixing, connection, testing and
commissioning of double compression
brass cable glands and crimping type
Bimetalic lugs / sockets with necessary
tools and equipments as specified in
specifications and IS complete in all
respects. The glands and lugs / sockets
shall be suitable for cable size and type
mentioned above. The job also includes
earthing the glands and armour of the
cable with common earth bar or flexible
copper mesh as applicable.
25.01 * SIGNAL CABLE
MECHANICAL WORK
1.00 SUBMERSIBLE NON-CLOG PUMP
Supply, Installation, Testing and
Commissioning (SITC) of Submersible
NC Pump-Motor set suitable for sewage
application with semi-open or enclosed or
suitable type Impeller & wear Rings in
CF8M with CI FG 260 Casing & casing
cover, SS 410 shaft & with motor suitable
for 3-Phase, 415 V, 50 Hz., AC induction
Air filled dry type submersible motor of
mini. rating as specified having max.
1500 RPM sync. speed, insulation Class
'F' With temp. rise limited to class B and
IP-68 protection.
The scope shall include all required
accessories viz. automatic coupling
device, SS-304 heavy duty & of suitable
size double guide pipes of length to suit
the sump height with required supports,
SS-304 or suitable stainless steel grade
Chain with shackles (shall be with dual
hook / shackles of 100 mm or suitable
higher size at app. every 1.5m C-C
distance) & of length as per sump height
+ min. 3m, Submersible Power & control
cable (copper flexible & stranded type
conductor of reqd. cores & size for each
pump motor set) & length of sump height
+ min. 10 m long each run with necessary
electrical termination connection at
junction box/starter panel and RCC
foundation blocks for auto coupling &
delivery bend, PMU etc. complete as per
IS and Specification and also including in
scope any other parts/accessories / fittings
required to complete the work in all
respects & satisfactory operation of pump
Pump Capacity: 50 m3 / hr.,
Motor Rating: min. 11 kW (or higher
rating as reco. by pump mfg.)
Overall Efficiency at Duty- min. 38% 2.00 Set 304124.00
SITC of CI/DI Double Flange Manually
operated Sluice Valve as per IS 14846 PN
1.0 of following sizes with SS 304 seat
rings, SS spindle with all hot dipped
galvanized hardwares, bolts, nuts &
washers, gaskets including all taxes, etc.
complete as per IS and Specification.
* 125 mm NB (At delivery of each Pump
& 1 no. at Header) 3.00 No. 4943.00
2.01 SITC of Non-slam, flanged, single door,
swing type Non Return Valve conforming
to IS 5312, Part 1 having pressure rating
PN 1.0, having CI/DI body and door,
CF8M seat rings along with all necessary
hardwares and complete as per IS and
Specification.* 125 mm NB (At delivery
of each Pump) 2.00 No. 7229.00
3.00 MS PIPES & SPECIALS:
Supply, Gas cutting of pipe, Fabrication,
welding, Installation, testing and
commissioning of MS pipe & Specials,
reducer, expander, bend, Y-Joint, TEE
etc. conforming to IS 3589 & flanges
confirming to IS 6392-PN-1.0, fabricated
from MS. plate with necessary supports &
anchoring. Pipe fabricated from MS plate.
(Excluding supply of flange) as per specs.
and complete in all respect.
* 125 mm NB x min. 4.0 mm Thk 30.00 Rmt. 1134.17
3.01 Supply, Welding, Installation, Testing &
commissioning of MS flat machined
faced flanges confirming to IS 6392 &
drilled as per IS-1538 with drilling off
centre bolt holes and flange thickness as
per PN 1.0 including cutting & welding.
* 125 mm NB - Drilled 12.00 No. 1030.00
3.02 * 125 mm NB - Drilled Blind 1.00 No. 750.00
3.03 * 100 mm NB - Drilled. 2.00 No. 800.00
4.00 Flanged Joints of Pipes, Fittings and
Supply, Installation, Making of Flanged
CI / GI / MS Pipes, Fittings and Specials
Joints with all jointing materials, rubber
packing, nut bolts, labour etc.for
complete connection.
5.00 MONORAIL EOT WITH ELECTRIC
SITC of Electrically Operated Chain
Hoist & Electrically operated Trolley,
suitable to operate on Mono Rail Girder
having motorised motion, manufactured
as per IS:6547-1972-Class-II & IS-3177-
Class-II, complete with brake, chain-gear,
motors, safety device, pendant push
button, starter panel, cables from motor to
starter panel and all other required
accessories like limit switches, power
supply system (Fastoon cable type),
fasteners, epoxy painting, etc. tested for
overload as per IS and as per
specifications, complete in all respect.
Capacity: min. 1.0 Ton. (For Subm. NC
Lift: min. 10 m or as per site req.
Bay Length: min. 5 m or as per site req. 1.00 No. 150880.00
(w/o MONORAIL GIRDER & MS
supporting structure)
Note: Minimum as specified capacity or
higher as per requirement such that EOT
with ECH capacity is min.1.25 times of
the pump /motor OR single heaviest
component to be lifted within pump
6.00 Providing, Supply of Structure Steel at
site of work with freight, loading,
unloading carting, etc. including all taxes
and duties complete such as joints,
channels, angles, Iron Rails,
ISA/ISMC/ISMB/MS flat, Plates,
Chequered plates (below 8mm thickness)
for cable trench etc. required for support
structure of all Electro-mechanical
equipment, piping, etc. for support on
floor / wall / beam / brackets etc. as per
tender and IS. 500.00 Kg 64.84
6.01 Labour Charges for lowering, laying,
Fixing with fabrication various size
section of MS such as joints, channels,
angles, Iron Rails, ISA/ISMC/ISMB/MS
flat, Plates, Chequered plates, for cable
trench etc Complete with two coats of red
oxide and two coats of approved colour
shade of epoxy paint as per relevant IS
and as per specification. 500.00 Kg 11.37
7.00 MISCELLANEOUS WORK
Dismantaling & removal / shifitng of
existing mechanical equipments installed
in well of pump house like 2 nos. pump
sets & all electrical cables, valves,
expansion bellows, pipes & specials as
required from its place carefully without
damaging them and stacking them within
the pumping station area as directed by
Engg. In. of Charge complete in all
respects and to permit the installation of
new pump sets, other electro-mech
equipment including instrument items
and other associated items of this tender
scope / BOQ. 1.00 Lot 11250.00
7.01 Dismantling of all existing Pump set
foundation (if req.) in well / pump house,
existing support structure of pipe, valves
and other equipments as existing at site
for dry well as well as on top of wet well
slab or at other units of pumping station
as applicable including breaking,
removing & carting of debris and various
material for carrying out necessary
electro-mechanical upgrdation /
refurbishment work and for constructing
new foundations/supports complete in all
respect and as required for installation
and satisfactory operation of all electro-
mech equipment and instrument items as
per the tender scope / BOQ. 1.00 Lot 9000.00
7.02 All miscellanious Civil Work including
modification, providing cut-outs minor
repairing / finishing works etc. providing
RCC support of valves, pipes & fittings,
grouting work, Required civil works
including modification, finishing work
for existing pump house flooring, etc. in
pump house and any other unforeseen /
emergency work during dismantaling of
existing pump & during installation in
existing running wetwell / pump house
etc. and all other as requried to complete
the work in all respects and as required for
installation and satisfactory operation of
all electro-mech equipment and
instrument items as per the tender scope /
ELECTRICAL WORK
8.00 TPN MCCB (For LT Service Obtaining
SITC of 250A TPN microprocessor
MCCB (50kA) with O/L, S/C & E/F
protection with Extended rotary handle,
Terminal spreader, Auxiliary change
over & Trip contact, with Outdoor
Enclosure with canopy 2mm thick
Single/double door & Wall mounted/
stand mounted as per site requirement
(with incoming & outgoing cable entry at
bottom )with Cable end boxes with RYB
indicating lamp, Digital voltmeter, VSS,
ON,OFF & Trip indicating lamp etc as
per Power supply company requirements
& location. Including all civil works for
fixing of panel on wall.
(Wall mounted at Location as per PSC
8.01 MEDIUM VOLTAGE PANEL BOARD
SITC of PMCC Panel (50kA),
compartmentalized, Stand mounted,
operating height maximum 1800/1900
mm, Extensible on both ends, suitable for
Manual & Auto operation -Local &
through PLC/SCADA operation as per
site conditions complete in all respects as
per Tender SLD / Specification / IS and
including following as minimum:
(1) One no. Incoming feeder FP 250A
Microprocessor MCCB (50kA), LSIG for
I/c with Digital Voltmeter, Voltmeter
selector switch, Digital Ammeter,
Ammeter selector switch, Digital PF
meter, MFM with RS-485 of Class-0.5,
Indicating lamps R,Y,B,On,off,Trip,
3nos. 250A/5A, Cl.-0.5 metering CT, CL
0.5 CT for APFC relay etc. Constant
voltage/control voltage transformer
1500VA, 415V/230V AC, with tapping
+/-5% in steps of 2.5%, 32A DP MCB.
(1.1) Surge protection device, 3P + N,
Type 2 for lightning/surge protection.
(2) 250A TPN Main Aluminium busbars.
(main busbars size with current density
(3) 11 KW STAR -DELTA STARTER
11 KW or higher as per pump
manufacturer recommendation Star-delta
starter with 50A TPN Thermal magnetic
MCCB with Adjustable O/L &
Adjustable S/C protection, 50A AC3 duty
contactors (3 nos.), O/L Relay, star-delta
timer, Ammeter with ASS, Resin Cast CT
Cl: 0.5(3 nos.),SPP, PMU, A/M, L/R
switch, ON, OFF, TRIP Indication &
Start, E-Stop & Reset pushbutton etc. for
S/D starter. complete in all respects.
(4) 32A TPN MCB FEEDER : 3 NOS.
2 nos. 32A 'C' curve TPN MCB feeders (1
no. for ECH at P.H, 2 nos. Spare) with
indicating lamp etc.
(5) 32A FP MCB FEEDER : 3 NOS.
3 nos. 32A 'C' curve FP MCB feeders (1
no. for Lighting, 2 nos. Spare) with
indicating lamp etc.
(6) APFC separate cubical compartment
(minimum 10 KVAr) having 1no. 32A
TPN Thermal magnetic MCCB 50KA
with adjustable overload and adjustable
short circuit, 6 step APFC relay with RS
485, 1no. 32 A/5A, Cl.-0.5 APFC CT,
no. 5 kVAR capacitor with 16A TP D
curve MCB, 2 nos. 2 kVAR capacitor 1.00 Set 259000.00
with 16A TP D curve MCB, 1 no.
kVAR capacitor with 16A TP D curve
MCB with capacitor Duty Contractor
A/M switch, On delay timer etc.
Complete in all respects as per
Specification, IS & SLD.
(7) Multiplication relay as required for
dry run protection of pumps.
NOTE: 1). All MCCB shall be 50KA, Ics
= 100% Icu, inbuilt protection with adj
O/L and Adj.S/c (LSIG for MP MCCB),
Extended rotary handle, Terminal
spreader,Auxiliary Change over contact
and trip contact as required. 2) All MFM,
ACB, Soft Starter,MPR,Temp.Scanner
etc shall be with inbuilt RS
8.02 ICP Cubical a part of PMCC Panel as
ICP cubicle compartment as a part of
PMCC (as per SLD) panel with required
input / output for field instruments
interfacing at terminal strip& comprising
(a) Door mounted 1 no. Process indicator
with 4 nos. relay output for start pump at
high level and stop at low level for Level
transmitter ,UPS power ON Indication,
(b) Required separate isolation switches
(DP MCB only) for incoming 230 V AC
power mains from UPS & outgoing
power feed to 1 no. Process indicator ,
Nos. Multiplication Relay (1 no. 1 input +
2 Output) for Dry run protection of Pump
at low-low level ,etc.
(c) Offline type UPS of suitable rating
(min. 250 VA with 15-20 min. backup
time ) mounted within cubicle on main
incoming power line with required
isolation device (DP MCB) & outgoing
feed to power supply ofinstruments.
(d) Any other as required to complete the
work and meet the tender
requirement/specification. 1.00 No. 40000.00
9.00 LOW VOLTAGE (LT) CABLES
Supply, laying, testing and
commissioning of 1.1 kV,
A2XFY(X)/2XWY(X) XLPE insulated
(IS 7098) Al. / Cu stranded conductor,
Extruded innersheath cables as per
specification & IS.
The cable when laid outside the building
shall be laid underground in excavated
trench, as per specified method and shall
be laid in prepared trench/ on cable tray
when laid inside the building.
* SITC of 3.5C x 240 sq. mm.
A2XFY(X) Cable (1 run for MCCB to
PMCC panel) 15.00 m 972.34
9.01 * SITC of 4C x 6 sq. mm. A2XFY Cable
( For 2 nos. street light ) 30.00 m 107.85
9.02 * SITC of 4C x 2.5 sq. mm. 2XWY/2XFY
Cable (For 1 no. EOT with ECH at P.H ) 20.00 m 244.80
9.03 Single core 95sq. mm. PVC insulated
circular unsheathed copper conductor
flexible Cable (For Power supply
Metering Panel to I/c MCCB Unit) 15.00 m 787.46
10.00 CABLE END TERMINATION AND
SITC of Double compression weather
proof type Ni-plated brass cable glands
and crimping type Bimetallic lugs /
sockets with necessary tools and
equipments as specified in specifications
and IS. The glands and lugs / sockets
shall be suitable for cable size and type
mentioned below & as per specifications.
1) Earthing the glands and armouring
with earthing clamp and jumper and also
connecting to common earth bar.
2) The job also includes, if necessary,
supply & fixing of extension busbar of
same material on MCCB or panel board
terminal / connector to connect more than
one no. of parallel cables or to connect
higher size cable to lower size unit. The
job also includes earthing the glands and
armour of the cable with common earth
bar or flexible copper mesh.(Cable
termination qty. shall be as per site
* 3.5C x 240 sq. mm. A2XFY(X) Cable
(1 run for MCCB to PMCC panel) 2.00 No. 483.60
10.01 * 4C x 6 sq. mm. A2XFY Cable ( For,
nos. street light ) 4.00 No. 51.36
10.02 * 4C x 2.5 sq. mm. 2XWY/2XFY Cable
(For 1 no. EOT with ECH at P.H ) 2.00 No. 57.35
10.03 Single core 95 sq. mm. PVC insulated
circular unsheathed copper conductor
flexible Cable (For Power supply
Metering Panel to I/c MCCB Unit) 10.00 m 42.80
11.00 CABLE TRAY
SITC of G.I. Ladder/ Perforated type with
top cover medium duty (2mm thick)
Cable Tray with necessary bends, tees,
coupler plate and clamps for fixing. All
material shall be Hot dip galvanised as per
150 x 50 mm - Ladder type 30.00 m 278.18
11.01 Making Trench/ excavation in soft soil of
suitable width and of depth (minimum
750mm depth (LT) & 1000mm for HT)
for laying cable/ DWC pipe and back
filling the same and making the surface as
normal ground as per IS & Tender
Specification/Drg. (For laying of LT
cable) 20.00 m 46.22
11.02 Cable Trench, Laying & Installation of
Cable: Making cable trench in soft soil of
suitable width of 90cms deep for laying
cable, Sand cushioning and brick
protection on sides and on top all over the
run and back filling the same and making
the surface as normal ground as per IS &
Specification. (For laying of LT cable in
ground) 20.00 m 46.22
12.00 CHEMICAL EARTHING SYSTEM
SITC of Maintenance free chemical
earthing with earthpit of minimum bore
size dia. 225 mm Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as
per IS-3043:1987 /Tech spec. made of
corrosion free Hot dip Galvanised (min
150 Microns) Pipes having Outer pipe
dia of 76 mm , Inner corrosion free Hot
dip galvanised (80 to 100 micron) pipe
dia of 26 mm with copper flat strip type
connection terminal 14mm dia with
constant ohmic value surrounded by
highly conductive corrosion resistant
chemical compound with high charge
dissipation suitable for electrical
installation & 3 Mtr. length of Pipe with
two nos. 25 Kg. bag of Back filling
compound. (2 nos. for PMCC panel & all
elect. Equipments)
NOTE: Earthing Resistance value & date
shall be painted on the chamber cover. 2.00 Set 7093.97
12.01 SITC of pipe type earthing having
cms long and 2.5cms dia. Galvanised iron
pipe with coupling and buch buried in
specially prepared earth pit complete with
necessary 8 SWG earth wire (For 2 nos
for street light) 2.00 No. 368.05
12.02 SITC of 50 mm (w) x 6 mm (T) etc. sizes
as required, HOT dip galvanized GI Strip
including supply & fixing using GI
spacers, saddles when laid inside the
building and inclusive of excavation &
refilling of earth when laid outside the
building & interconnection with earth pit
& all electro-mechanical equipments.
(50 x 6 G.I Strip wt. 2.3 kg/m, 2.3 x
12.03 Supply, laying and erection of 25 mm (w)
x 3 mm (T) etc. sizes as required, HOT
dip galvanized GI Strip including supply
& fixing using GI spacers, saddles when
laid inside the building and inclusive of
excavation & refilling of earth when laid
outside the building & interconnection
with earth pit & all electro-mechanical
equipments. (25 x 3 G.I Strip, 0.6 Kg/m,
12.04 SITC of HOT Dip Galvanized iron strip
(8 SWG G.I Strip, 0.103 Kg/m, 0.103 x
13.00 INTERNAL WIRING
SITC of Mains & outlet points wiring
with 1.1 kV grade FRLS PVC insulated
ISI marked flexible stranded copper
conductor wires with medium class min.
25mm. dia. Rigid PVC pipe and
accessories to be erected concealed in / to
be run on surface / wall / ceiling with
following sizes as mentioned below. The
unit rate wirings shall be with connector,
PVC junction box, wires, holder, ceiling
rose, angle holder, switch, sockets, switch
board, brass chromium / cadmium plated
machine screws, phase and neutral wires,
green Earth continuity wires etc. as
required to complete wiring from LDB
panel to the final outlet termination
points. The wiring shall be as per
IS:732, IS:4648 and as per tender
specification / IS.
* SITC of Mains wiring with 3 wire
13.01 * SITC of Mains wiring with 3 wire
13.02 * SITC of Mains wiring with 4 wire
13.03 * SITC of Mains wiring with 4 wire
13.04 SITC of Point wiring for Light / fan / Bell
/ Primary Point with 2nos. 1.5 sq. mm &
earth wire of 1.5 sq. mm (green) both are
of ISI marked 1.1 kv grade FRLS PVC
insulated multistrand copper wires, pipe
to be erected concealed in flushed on wall
/ ceiling, complete with 6A Tissino Type
ISI marked flush type switch / bell push
& accessories erected on metal / PVC Box
covered with 3 mm thick PC
(Polycarbonate) / Acrylic sheet with
necessary lamp holder / ceiling Rose / H.
D. connector as directed with medium
class Rigid PVC pipe & accessories. 7.00 No. 282.46
13.05 SITC of 6 A independent Plug with 2 nos.
1.5 sq.mm Cu. Mains size wiring &
earthwire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires with
medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling,
complete with ISI marked 3 / 5 Pin socket
and tissino type switch erected with earth
continuity connection erected on Metal /
PVC box covered with 3 mm thick PC
(Polycarbonet) / Acrylic sheet. (1 no. for
LT Room cum P.H.) 1.00 No. 248.22
13.06 SITC of 6/16 A independent Plug with
nos. 4 sq.mm Cu. Mains size wiring &
earthwire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires with
medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling,
complete with ISI marked 3 / 5 Pin socket
and tissino type switch erected with earth
continuity connection erected on Metal /
PVC box covered with 3 mm thick PC
(Polycarbonet) / Acrylic sheet. (1 no. for
LT Room cum P.H.) 1.00 No. 487.44
13.07 SITC of One 300/380 mm dia. Ex fan 16A
independent Plug point near Ex. Fan with
2nos. 4 sq.mm Cu. Mains size wiring &
earthwire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires with
medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling,
complete with ISI marked 3Pin socket
and tissino type switch erected with earth
continuity connection erected on Metal /
PVC box covered with 3 mm thick
PC(Polycarbonet) / Acrylic sheet. Plug
point shall be near Ex.Fan.
(1 no. at L.T Room cum P.H) 1.00 No. 487.88
13.08 SITC of 380mm sweep 1400 R.P.M
exhaust fan, capacitor type, having double
ball bearing, M.S.blades, mounting
frame, forearms, suitable to operate on
230V,50 HZ AC supply conforming to IS:
2312.Fan shall be painted with epoxy
grey colour controlled by one 6 A flush
type switch on board and 6A plug point
near Ex. fan.(1 no. L.T Room cum P.H.) 1.00 No. 3081.36
13.09 SITC of Single Phase 20 A 3 Pin Metal
clad Industrial Type Socket with plug top
and 20A SPMCB, suitable for flush
mounting, in 16 SWG MS box of suitable
size and covered with 3 mm thick
electrical grade hylam sheet or equivalent
ISI marked Electrical grade Bakelite sheet
and earthing with 2.5 sq.mm insulated
copper wire run inside the conduit
including interconnections etc. complete
(1 no. for LT Room cum P.H.) 1.00 No. 820.00
13.10 SITC of Sheets steel powder coated
weather proof enclosure suitable for as
well as with incorporating One no. 32 A,
415 V MCB Four Pole for Motor &
Inductive load (C Curve) having 10 KA
breaking capacity & confirms to IS:
(For 1 no. for EOT with ECH at pump
house) 1.00 No. 663.35
14.00 LED LIGHT FIXTURES & LIGHTING:
SITC of Indoor wall mounting 20Watt or
up to 25% higher wattage LED 4 feet
Tube Light indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as
a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA
polyester powder coated and high U.V. &
corrosion resistance with diffuser and/or
Polycarbonate optics with company
120 to 300 V, Power Factor more than
CCT 4000 K to 6500K, Uniformity ratio
Luminaire efficacy > 85 lumens/watt,
LED driver efficiency > 85 %
(Each fitting required LM-79 & LM-80
* Tube Light with integral / non-integral
driver, Surge-4 KV, IP-20, 4 feet, Cat-III
( 2 nos. at LT Room cum P.H.) 2.00 No. 400.58
14.01 * SITC of 7 watts LED Lamps integral
type,cool white with PC diffuser suitable
for B22 LAMP holder (For 1 no. at LT
14.02 SITC of 40W LED Surface / Wall
mounted LED Flood Light fittings with
High power White LEDs wattage of
1Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast
aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and
Polycarbonate optics/ lenses with
company mark/name engraved or
120 to 300 V, Power Factor more than
0.95, THD < 20%, CCT 5000 K to
K, Uniformity ratio >0.45, Luminaire
efficacy > 85 lumens/watt . LED driver
efficiency > 85 %.
(Each fittings required LM-79 & LM-80
(IP-65), Surge - 4KV Cat-III
For Indoor use: 1 no. 1.00 No. 7164.15
14.03 SITC of 'B' class galvanised iron pipe
mm outside dia 45 cms long duly welded
on 20 cms x 20 cms x 3 mm thick M.S.
base plate, erected on wall or corner for
mounting luminaries with necessary
hardware materials duly painted for wall
mounting indoor flood light fixtures on
Wall of Buildings 3.00 No. 556.36
15.00 EXTERNAL LIGHTING (Flood
SITC of 70W LED Wall mounted LED
Flood Light fittings with High power
White LEDs wattage of 1Watt and above
assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free
High pressure die cast aluminum housing
with smooth finish powder coated and
heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses
with company mark/name engraved or
embossed 120 to 300 V,Power Factor
more than 0.95, THD < 20 %, CCT
K to 5700K, Uniformity ratio > 0.45,
Luminaire efficacy > 85 lumens/watt .
LED driver efficiency > 85 %.
( Each fittings required LM-79 & LM-80
certificates) (IP-65), Surge -4KV Cat-III
For Outdoor use: (3 nos. for area lighting) 3.00 No. 8388.14
15.01 EXTERNAL LIGHTING (STREET
SITC of Street Light Pole, steel tubular
swaged type, 7.5 meter long with single
arm & M.S.base plate with pipe cap and
over hung 1.5 m long having dia to suit
the socket of 240V LED street light
fixtures. Street light pole unit rate shall be
with (i) IP 65 SMC box of size 20 x 15 x
15 cms. with MCB & terminal strip inside
the box with hinged/sliding door (ii)
50mm dia, B class GI pipe bracket
min.1.5mtr long for Incoming & outgoing
cable (iii)MS Cable Clamp of 25 x 3mm
(iv)SITC of 1.5 Mtr.single Arm bracket
of medium duty MS pipe of 4.2 cms. Out
side dia complete with suitable sleeve
tubing 45 cms. long of required size of
pole top etc. and having spread of 1.5.mtr.
length with 110 deg.(v) Complete painted
with one coat of Red oxide / PU base
primer and two coats of Aluminium / PU
paint for Pole,Arm, pipe etc. 2.00 No. 9881.74
15.02 SITC of 70W LED Street light fittings
with High power White LEDs wattage of
1Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast
aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and
Polycarbonate optics/lenses with
company mark/name engraved or
120 to 300 V, Power Factor more than
0.95, THD < 20%, CCT 5000 K to
Uniformity ratio >0.45, Luminaire
efficacy > 85 lumens/watt. LED driver
efficiency > 85%.
(Each fittings required LM-79 & LM-80
Street Light (IP-65), Surge - 4 KV,
watt Cat-III 2.00 No. 8234.07
15.03 SITC of M-20 / 1:2:4 cement concrete
foundation for Street light pole & 70 %
PCC from bottom including excavation
for the pole of size 60 x 60 x 120 cms.
Deep in below ground level with plinth of
45 cms x 45 cms(or 45 cms dia x 45 cms)
high upper ground level with necessary
curing and finishing in approved manner. 2.00 No. 1112.71
16.00 SAFETY ACCESSORIES
SITC of following safety accessories
complete with necessary fixing brackets,
other accessories and tools etc. as
required to complete the job.
Supply & Erecting carbon dioxide (CO2)
fire extinguisher of 6.5 kg capacity with
necessary clamps made from 50 x 6 mm
M.S. Flat with nut & bolts grouted in wall
(1 no. for LT Room cum P.H.) 1.00 No. 8670.59
16.01 Supplying of standard first AID box with
antiseptic cream, medicine for use on
wounds due burn, crepe bandage, guage
bandage, medicated ready to use bandage
(Band-aid) adhesive tape for medicinal
user, scissors, antiseptic solution (Savlon
or similar) etc. (All above contents shall
be of standard makes)
(1 no. for LT Room cum P.H.) 1.00 No. 299.58
16.02 Supply & fixing of printed instruction
(First Aid) Chart both in English and
Gujarati and duly framed with front
glasses, for treatment of person suffering
from electric shock. (1 no. for LT Room
16.03 Supply and fixing of 20 W fluorescent
lamp operated emergency light with
maintenance free battery for 3 hours
operation during mains power failure.
(1 no. for LT Room cum P.H.) 1.00 No. 2540.00
16.04 Supply and laying of Synthetic Insulating
Mat of Class - A of min. thickness 2 mm
as per IS:15652 and with good electrical
insulation property for 1.1 KV / 3.3 KV
as per site requirement. (for LT Panel) 2.00 m2 1027.12
16.05 Providing pair of rubber hand gloves ISI
make suitable for working on 22 KV
supply 1.00 No. 218.26
17.00 LIASONING CHARGES FOR
Power Liasoning Charges for obtaining
N.O.C from Electrical Inspector /
Statutory authority for Power / Ele.
Installation. (Fees shall be paid by
tenderer for obtaining N.O.C. from
Electrical Inspector / Statutory authority
on behalf of client and shall be
reimbursed on submission of original
receipt to Client).
Liasoning Charges shall include
preparing required attested documents &
drawing for obtaining NOC on behalf of
client (Applicable Fees / deposits shall be
reimbursed by Client). 1.00 LS 15000.00
INSTRUMENTATION WORKS
18.00 PRESSURE MEASURING SYSTEM
Supply, installation, testing &
commissioning of Diaphragm Type
pressure guage having 150 mm dial with
necessary fittings/accessories in SS
(manifold valve, nipples etc.) complete in
all respects and as per specs.
Range : 0 - 4 Kg/cm2 (at each pump
discharge line) 2.00 No. 5413.00
19.00 LEVEL MEASURING SYSTEM FOR
SUMP Supply, installation, testing and
commissioning of Ultrasonic type Level
Transmitter with remote type transmitter
with 10meter cable between Sensor and
Transmitter along with all required
accessories, Weather proof enclosure for
transmitter for outdoor application,
mounting stand , etc. complete in all
respects as per specification and having
following measurement ranges for liquid
(Water) application:
Meas. Range: upto 10 m (at sump) 1.00 No. 59436.00
19.01 Supply, installation, testing and
commissioning of Float type Level
Switch along with 10 mtr. Cable and WP
Junction Box (at sump for dry run
protection of pumps through relay
multiplication in PLC), etc., complete in
all respects and as per specification.
Meas. Range: upto 10 m (at sump ) 1.00 No. 12802.00
20.00 ELECTRO MAGNETIC FLOWMETER
Supply, installation, testing and
commissioning of Full Bore
Electromagnetic flow meter comprising
of IP-68 Sensor, IP-66 remote type
transmitter with 20 m cable between
sensor and transmitter along with all
mounting accessories, Weather proof
enclosure for transmitter, hardware,
mounting stand, etc.
as per specification and to complete the
work in all respect as per site condition
necessary connection with pipe and shall
have following size.
Meter Size: 125 mm (At Pump common
Pipe Size : 125 mm 1.00 No. 82972.00
21.00 INSTRUMENT CABLE &
Supply, Laying, Installation, Connection,
Termination, Testing & Commissioning
of Instrument Cables as per specs.
The unit rate shall include
a) Supply, loading & unloading of the
cable at site from store. 50.00 m 170.00
b) Shifitng of cable from site store to
place of installation.
c) Fixing of cable clamps, brackets,
supports, route markers etc. where ever
required to fix the cables safely.
d) Excavation, back filling and levelling
of ground alongwith laying of fine sand,
protection bricks and other necessary civil
material for laying cables outside the
f) Testing and submission of sketches &
reports of all the cables laid.
21.01 * SIGNAL CABLE
22.00 CABLE END TERMINATION AND
Supply, fixing, connection, testing and
commissioning of double compression
brass cable glands and crimping type
Bimetalic lugs / sockets with necessary
tools and equipments as specified in
specifications and IS complete in all
respects. The glands and lugs / sockets
shall be suitable for cable size and type
mentioned above. The job also includes
earthing the glands and armour of the
cable with common earth bar or flexible
copper mesh as applicable.
22.01 * SIGNAL CABLE
Operation And Maintenance Cost
Item Description Quantity Unit Rate
1.00 Comprehensive Operation and
Maintenance of the various
components of Underground
Drainage Scheme undertaken in this
tender mainly Sewer collecting
network, Pumping Station, Rising
Main Pipeline, Pumping Machinery
and Electrical works & other works
as a whole including
1) Breakdown Maintenance or
Emergency Maintenance,
2) Day to Day Maintenance,
3) Preventive or Periodic
4) Major Maintenance (or Special
repairs and replacement including
Training to O & M staff of
Municipality. The O & M work shall
be carried out as per detailed
specifications in the tender &
maintaining the record for the same.
* For 1st Year 12.00 Months 133811.39
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Doc.pdf
Tender Doc. Volume-I.pdf
04. Electrical Specifications.pdf
03. ROADWORKSBOOKLET.pdf
02 Vollume-2 Specification Building.pdf.pdf
Schedule-B.pdf
Download all tender documents and submit your bid