Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC CHETTIYADA KANNADY PO PULINCUNNOO ALAPPUZHA | ₹1.3 Cr | L1 | Accepted-AOC l1 |
Tender Value
₹1.3 Cr
EMD Value
₹50,000
Closing Date
24 May 2022, 11:00 amClosed
Assistant Executive Engineer
Assistant Executive Engineer LSGD Division Idukki Painavu
205 kLD Sewage Treatment Plant FOR IDUKKI DISTRICT PANCHAYATH DISTRICT HOSPITAL AND DISTRICT AYURVEDA HOSPITAL THODUPUZHA IDUKKI DISTRICT E-Quotation
2022_LSGD_490046_3
01/Q/AEE/LIDEW/IDK//2022-2023
Open Tender
Civil Works - Buildings
Item Rate
180 days
THODUPUZHA
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹50,000
Yes
30 Aug 2022
13 May 2022
27 May 2022
13 May 2022
24 May 2022
13 May 2022
13 May 2022 - 24 May 2022
Amount
Bar Screen Supply, erection, testing and commissioning of 10 mm clear spacing SS 304 make as per technical specification
Raw Sewage Pump (Submersible Cutter Pump) for Collection Tank 1 Supply, erection, testing and commissioning of submersible cutter pump with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specificationFlow rate: 13.5 m3/hr , Head: 8-10 m, Power rating: 2 HP
Raw Sewage Pump (Submersible Cutter Pump) for Collection Tank 2 Supply, erection, testing and commissioning of submersible cutter pump with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specificationFlow rate: Flow rate: 5 m3/hr , Head: 8-10 m, Power rating: 1 HP
Raw Sewage Pump (Submersible Cutter Pump) for STP Collection Tank Supply, erection, testing and commissioning of submersible cutter pump with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specificationFlow rate: Flow rate: 9 m3/hr , Head: 8-10 m, Power rating: 2 HP
Air Blower Supply, erection, testing and commissioning of Twin type Rotary Air Blower (1W+1S) of free air at 50 mm Water Column &driven through “V” belt or directly coupled through flexible coupling to a TEFC motor, suitable for 415±10% volts, 3 phase, 50 Hz AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification Capacity: 230 m3/h, Head: 5 m, Pressure: 0.5 kg/cm2, Power rating: 10 HP
Membrane Diffusers for aeration tank Supplying and fixing of retrievable type fine bubble diffusers of 63 mm dia and 600 mm long complete with laterals and headers and complete in all respects as required by the standard specifications complete with all accessories as per technical specification Make: PP
MBBR Media for the aeration Tank Supplying and keeping MBBR media in the aeration tank of make: polypropylene UV stabilized, effective surface area 400 m2/m3complete as per technical specification or as directed by Engineer in Charge Make: PP 22
Tube Settler media Supplying and keeping tube settler media with 600 mm vertical height Make: PP
Sludge Recirculation Pump Supply, erection, testing and commissioning of self-priming non clogging type pumps with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification Flow rate: 9 m3/hr , Head: 10m, Power rating: 1 HP
Raw Sewage Pump (Submersible Cutter Pump) for Sump of Sludge Drying Bed Supply, erection, testing and commissioning of submersible cutter pump with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification
Filter Feed Pump Supply, erection, testing and commissioning of mono-block pumps with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification.
Pressure Sand Filter Supply, erection, testing and commissioning of vertical self-supporting Pressure Sand filter in FRP vessels, operating pressure 10 kg/cm2, pressure gauges at inlet and outlet, sample cock, air vent valve with piping, CI butterfly valves and all accessories with backwash arrangement, with initial charge of filter media for sand filter, complete
Activated Carbon Filter Supply, erection, testing and commissioning of vertical self-supporting Activated Carbon filter in FRP vessels, operating pressure 10 kg/cm2, pressure gauges at inlet and outlet, sample cock, air vent valve with piping, CI butterfly valves and all accessories with backwash arrangement, with initial charge of filter media for activated carbon filter, complete.
Hypodosing system Supply, erection, testing and commissioning as required by the standard specifications complete with all accessories as per technical specification
Level Switch for Raw Sewage Pumps Supply, erection, testing and commissioning, complete in all respects as required by the standard specifications complete with all accessories as per technical specification
Level Switch for Filter Feed Pumps Supply, erection, testing and commissioning, complete in all respects as required by the standard specifications complete with all accessories as per technical specification
Flow Meter Supply, erection, testing and commissioning of electromagnetic flow meter with flow recorder, digital flow indicator, flow integrator with sensors, totalizer, transmittal and display arrangement and complete in all respects as required by the standard specifications complete with all accessories as per technical specifications to fix in the incoming pipeline to treated
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: slab
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Extra for every additional lift of 1.5m or part thereof in excavation/ banking excavated or stacked materials. All kind of Soils
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforcedcement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: slab
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even afterfixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality. L D - 2.5Rectangular shape 600x450 mm internal dimensions
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Extra for every additional lift of 1.5m or part thereof in excavation/ banking excavated or stacked materials. All kind of Soils
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work up to plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil
Extra for every additional lift of 1.5m or part thereof in excavation/ banking excavated or stacked materials. All kind of Soils
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work up to plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Extra for every additional lift of 1.5m or part there of in excavation/ banking excavated or stacked materials. All kind of Soils
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work up to plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for: slab
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality. L D - 2.5Rectangular shape 600x450 mm internal dimensions
Clearing Jungle including uprooting of rank vegetation, grass, brushwood, trees and samplings of girth upto 30 cm measured at height of 1m aboveground level and removal of rubbish upto distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately.All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: slab
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: slab
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work up to plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality. L D - 2.5Rectangular shape 600x450 mm internal dimension
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work up to plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work up to plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately.All works above plinth level upto floor V level
Centering and shuttering including strutting, etc and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: slab
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality. L D - 2.5Rectangular shape 600x450 mm internal dimensions
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc
Centering and shuttering including strutting, etc. and removal of form for: slab
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality. L D - 2.5Rectangular shape 600x450 mm internal dimensions
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars.
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doss by weight of cement
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
Centering and shuttering including strutting, etc. and removal of form for: slab
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
Centering and shuttering including strutting, etc. and removal of form for: slab
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Extra for every additional lift of 1.5m or part thereof in excavation/ banking excavated or stacked materials. All kind of Soils
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: slab
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V leve
Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars Fe-500 D or more.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Clearing jungle including uprooting of ranked vegetation, grass, bush wood, trees and saplings of girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50 m outside the periphery
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size), up to plinth level with cement mortar 1:6 (1 cement : 6 coarse sand)
Brickwork with common burnt clay FPS (non-modular) bricks of Class designation 7.5 in super structure above plinth level up to floor V level in all shapes and sizes in : cement mortar 1: 4 (1 cement : 4 coarse sand)
12 mm Cement plaster finished with a floating coat of neat cement of mix :: 1:3 ( 1 cement: 3 fine sand)
Finishing walls with premium acrylic smooth exterior paint with silicon additives of required shade: new work (2 or more coats applied @ 1.43 L/10 m2 over and including priming coat of exterior primer applied @ 2.20 kg/ 10 m2.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc and disposing of surplus excavated soil as directed, within a lead of 50 m: pipes, cables etc exceeding 80 mm dia but not exceeding 300.00 mm dia.
Constructing brick masonry manholes in cement mortar 1:4 (1 cement: 4 coarse sand) with RCC top slab with 1: 2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix(1 cement: 2 coarse sand: 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1: 3(1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: inside sides 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 450 x 610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg): with common burnt clay FPS (non-modular) bricks of class designation 7.5
Extra for depth for manholes: size 90 x 80 cm : with common burnt clay FPS (non-modular) bricks of class designation 7.5
Steel Shutter for the gate of compound wall Providing and fixing in position, collapsible steel shutters with vertical channels 20 x 10 x 2 mm and braced with flat iron diagonals 20 x 5 mm size, with top and bottom rail of T-iron 40 x 40 x 6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m².
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge. 160 mm dia 6Kgf/cm2
Providing and fixing PVC pipes including jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 kg/cm2
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 50 mm dia Socket/ coupler
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 50 x 50 x 50 mm dia Tee
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 50 mm dia elbow
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 50 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 80 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 110 mm dia nominal bore
Providing and fixing of G.I elbow of 80 mm
Providing and fixing ball valve (PVC) of approved quality, high or low pressure, with plastic floats, complete 50 mm dia, Ball Valve
Providing and fixing ball valve (PVC) of approved quality, high or low pressure, with plastic floats, complete 80 mm dia, Ball Valve
Constructing brick masonry circular type manhole 0.91 m internal dia at bottam and 0.56 m dia at to[ in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ), and making necessary channel in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With cement burnt clay F.P.S. (non modular) bricks of class designation 7.5
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_703917.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .