Loading…
Loading…
Tender ID
Tender Value
₹6.2 L
EMD Value
₹15,500
Closing Date
30 Mar 2026, 4:30 pmClosed
Executive Engineer PMU Sreekandapuram
Office of The Executive Engineer ,KSEBL, PMU Sreekandapuram
INTERLINKING HT LINE FROM MAMANAM DTR TO IRIKKUR DTR
2026_KSEB_838511_1
TENDER/2025-26/6159/88 dt. 19-02-2026
Open Tender
Electrical Works
Percentage
60 days
Irikkur
refer tender document
6 documents required · 6 mandatory
₹1,534
Yes
₹15,500
Yes
20 Feb 2026
20 Feb 2026
1 Apr 2026
20 Feb 2026
30 Mar 2026
20 Feb 2026
20 Feb 2026 - 28 Mar 2026
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
Additional rate for excavation of one Pit for Coil Earthing in Laterite
Additional rate for excavation of one Pit for Coil Earthing in Hard Laterite.
Additional rate for excavation of one Pit for Coil Earthing in Soft Rock.
Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at a minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in ordinary soil & backfilling.
Additional rate for excavation of one Earth Pit (2.5m depth) in Laterite.
Additional rate for excavation of one Earth Pit (2.5m depth) in Hard Laterite.
Fiting One No MVT on existing cross arm excluding termination work (for One phase) of any rating for 11 kV AB Cable
Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm and connecting to existing MVT or other terminals,using the cable end termination kit supplied departmentally including charges for cable jointer etc. complete as per the direction of the departmental officers.
Fitting one set (3No.) 11kV LA and giving connections excluding earthing.
Doing straight joint on HT XLPE UG cables of sizes upto and including 3x185 sqmm using the cable jointing kit supplied departmentally as per specification after providing proper traffic signalling and caution board fencing etc. wherever necessary, including charges for cable jointer and other sundries etc. as per the direction of departmental officers at site.
Labour charges for loading HT A type pole from the stacking place and unloading the same at work site (transportation by any vehicle).
Providing concrete muffing of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides.
Additional rate for excavation of one Pit for HT Pole/HT Stay in Laterite.
Erecting 9m PSC pole as support pole for ABC stringing work-New
Erecting HT A-Type pole as support pole for ABC stringing work -New
Transferring LT single phase 2/3 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete.
Transferring LT three phase 4/5 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete.
Additional rate for refitting/redoing one Shackle Set, including reshacling one span, while renewing any type of LT pole.
Additional rate for refitting/redoing one Disc set while renewing any type of 11kV cut pole.
Labour charges for loading HT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle).
Fitting one LT 2 line cross arm on HT or LT existing poles including fitting insulators and binding the same with LT Line.
Fitting one LT 4 line cross arm on HT or LT existing poles including fitting insulators and binding the same with LT Line.
Additional rate for excavation of one Pit for HT Pole/HT Stay in Hard Laterite.
Additional rate for excavation of Pit for A type pole in Laterite.
Additional rate for excavation of Pit for A type pole in Hard Laterite.
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling one damaged 11kV PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling (without damage) one 11kV PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Labour charges for loading LT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle).
Object Marking (traffic signal painting) in one LT, HT, HT/LT pole for a height of 1.5m from ground level using approved quality primer one coat and two coats anti algal black and fluorescent white paint in alternate rings of 25cm width including cost of paints.
Fitting and providing one HT Stay for 11kV pole, including digging and back filling pit in ordinary soil.
Fitting and providing one Strut using HT PSC pole including digging and back filling pit in ordinary soil.
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole including digging and back filling pits in ordinary soil, drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
Drilling hole of various sizes on existing Channel/Cross Arm.
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole including conveyance of materials.
Fitting one Additional 2.4/3m Channel cross arm (75x40x6mm), in existing 11kV DP including conveyance of materials.
Additional rate for providing one HT Pin with insulator, complete on any type of HT pole.
Fitting and erecting one HT Double Pole Structure using A type pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP including conveyance of materials.
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 numbers of poles excluding loading& unloading charges.
Stringing of 11 kV Aerial bunched cable of size 3 x 120 + 1 x 95 sqmm with bare/insulated Messenger through existing poles
Erection of Anchor clamp / dead end clamp for 11kV ABC of any size
Erection of suspension clamp for 11KV ABC of any size
Providing Cable Tie
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap 16-95 sqmm
Installing One No. 4 way Satellite Connector of size Main :16 to 95, Tap:4 to 35 Sq.mm to the LT AB cable of Standard size
Erection of suspension clamp for LT ABC of any size
Dismantling of suspension clamp suitable for LT AB cable
Dismantling of Anchor clamp / dead end clamp for LT AB cable
Erection of Anchor clamp / dead end clamp for LT ABC of any size
Disconnecting and lowering down the single phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work.
Disconnecting and lowering down the three phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work.
Installing One No. Insulation piercing connector of size Main :16 to 95 ,Tap:1.5 to 16 Sq.mm
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
BidDocument.pdf
Tender Documents • 1.79 MB
GSTregistertion.pdf
Other Document • 0.01 MB
BOQ_1412614.xls
BOQ • 0.36 MB
DateExtensionCorrigendum2.pdf
PDF • 0.25 MB
DateExtensionCorrigendum.pdf
PDF • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .