Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC 19 1 69 3 PLOT NO 17 NEW ADARSH COLONY BIDAR 585 401 | BIDAR | KARNATAKA | 585401 | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹17.9 L+₹3.8 L (26.7%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in category as per NIT |
Tender Value
Refer Docs
EMD Value
₹39,800
Closing Date
20 Nov 2020, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
REPAIRS / MAINTENANCE OF FIRE FIGHTING LINES, CONTROL VALVES, HYDRANTS, HOSE REELS AND CONNECTED ITEMS UNDER GE AF AT AFS BIDAR
2020_MES_388821_1
8250/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bidar
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Bidar
₹39,800
Yes
23 Dec 2020
22 Oct 2020
21 Nov 2020
22 Oct 2020
20 Nov 2020
6 Nov 2020
Amount
Disconnection and taking down unserviceable double headed yard hydrant valve 63mm dia, and replacing the unserviceable End Cap, Lugs Grip and Rubber Washer, checknut and Polishing the hydrant carefully and refixing the same after repairs in its original postion complete all as specified and as directed by the Engineer-in-Charge. Note: Transportation charges if any involved shall be deemed to be included in the unit rate quoted.
All as per Item No 1 here-in-above but Single headed yard hydrant valve 63mm dia.
Disconnection and taking down unserviceable double headed yard hydrant valve 63mm dia, and S&F New Double headed yard hydrant valve 63mm instantaneous with operating wheels, end caps and securing chains, ISI Marked, complete alongwith necessary fixing materials requried for completion of job all as specified and directed by the Engineer-in-Charge.
All as per Item No 3 here-in-above but Single headed yard hydrant valve 63mm dia.
Disconnection and removing the u/s power contactor carefully from Panel board and S&F new power contactor 160 Amp Capacity , 440 V comprising of all accessories type MNX-110 complete all as specified and directed.
Disconnection and removing the u/s power contactor carefully from Panel board and S&F new power contactor MNX 185, 250 Amp Capacity , 440 V comprising of all accessories for 170 HP Pumpset complete all as specified and directed.
Disconnection and removing the u/s power contactor carefully from Panel board and S&F new power contactor MNX-80 of 100 Amp Capacity, 440 V comprising of all accessories for 75 HP Pumpset complete all as specified and directed.
Disconnection and removing the u/s power contactor carefully from Panel board and S&F new power contactor 25 to 32 Amp Capacity, 440 V comprising of all accessories for 12.5/15 HP complete all as specified and directed.
Taking down unserviceable hose reel drum alongwith hose including S&F new hose reel drum with 19mm dia, 36.5m long, reinforced rubberised fabric hose including 6.35mm dia nozzle with a ball valve swing type, recessed as per sample complete, hose (BIS mark) conforming to IS : 636, type II and complying to IS : 903 complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable corroded/broken Hose Box and S&F new Hose Box made of 18 gauge MS Sheet 800 x 600 x 250mm with double door with 4mm thick glass and door frame made of 16 gauge MS Sheet painted with fire red oxide and brilliant white inside the box, etc complete all as specified and as directed by Engineer-in-Charge.
Taking down universal type serviceable sprinkler quick/ early response type as per IS : 15105 / TAC guidelines, 68 degree temperature rating complete from any height of the Hangers and other technical buildings and servicing the same including renewal of Misc items if any and refixing the same in its orignal position complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing unserviceable sprinklers from any height of the building carefully and S&F New Sprinkler universal type, quick/ early response type as per IS : 15105/TAC guidelines, 68 degree temperature rating complete in Hangers and other technical buildings complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing the AFPP Oscillating type system Foam Monitor of capacity not less than 1800 LPM and servicing / Overhauling of the Foam Monitoring unit complete including renewal of unserviceable Parts, check nuts, monitoring system, cover, proposing devicer and dual jet by specialist and re-fixing the same in its original position complete all as specified and as directed by Engineer-in-Charge. Note : Proposing devicer to be serviced only by specialist / OEM, and charges deemed to be included in the unit quoted rate.
Disconnection and removing the unserviceable AFPP Oscillating type Foam Monitor system S&F AFPP Oscillating type foam monitor system unit of capacity not less than 1800 LPM complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing the AFPP Oscillating type system Water Monitor of capacity not less than 1800 LPM and servicing/Overhauling of the Water Monitoring unit complete including reneval of unserviceable Parts, check nuts, monitoring system and cover and re-fixing the same in its original position complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing the unserviceable AFPP Oscillating type Water Monitor system S&F AFPP Oscillating type Water monitor system unit of capacity not less than 1800 LPM complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing the pipe line connections connected to the Diesel Engine of Capacity 125 KW /167 HP (at Parachute Building), Type 4R 1040, Make :- KOEL unit carefully for finding out the defects and Servicing /Over hauling the same including and Replacement of unserviceable Fuel Filters, Air filters, Oil filters, Fan belt, Hose Pipe sets, Engine Oil, Coolant, Bearings packings etc complete and refixing the same in its original position couple with the pumpset and connecting the pipe line testing and commisioning complete all as directed by Engineer-in-Charge Note : All the misc items and Fuel Filters, Air filters, Oil filters, Fan belt, Hose Pipe sets, Engine Oil, Coolant, packings etc are deemed to be included in the unit rate quoted. However bearings shall be measured as supply only and the labour element involved shall be deemed to be included in the unit rate quoted.
All as per Item No 17 here-in-above but of capacity 58 KW/79 HP (at New ATC Building)
All as per Item No 17 here-in-above but of capacity 44.2KW/60 HP (at Air Field FF Pump house)
Disconnection and removing the Fire Fighting Pumps of Capacity 167 to 170 HP, Head 90 Mtr, Discharge 4590 LPM connected to the Diesel Engine of Capacity 125 KW /167 HP (at Parachute Building) alongwith connections and overhauling the same complete including renewal of worn out bearings, metalling & Polishing the shaft, Coupling Unit, Oil Seal, Gland, Impeller Sleeves, Impeller lock nuts, complete and re-fixing the pump in its original postion after completion of repairs and overhauling connecting the pipelines testing and commisioning complete all as directed by Engineer-in-Charge. Note : (1) All other misc items not covered above but required for satisfactory completion of job deemed to be included in the unit rate.
All as per Item No 20 here-in-above but of capacity 50 to 60 HP (at Air Field FF Pump house)
All as per Item No 20 here-in-above but of capacity 79 HP (at New ATC Bldg)
Disconnection and removing the Fire Fighting Jockey Pumpset of Capacity 10 to 15 HP, 440V connected to the Fire Fighting system (at Parachute Building, Air Field FF Pump house & New ATC Bldg) alongwith connections and overhauling the same complete including renewal of worn out bearings, metalling & Polishing the shaft, Coupling Unit, Oil Seal, Gland, Impeller Sleeves, Impeller lock nuts complete and re-fixing the pump in its original postion after completion of repairs and overhauling connecting the pipelines testing and commisioning complete all as directed by Engineer-in-Charge :- Note : (1) All other misc items not covered above but required for satisfactory completion of job deemed to be included in the unit rate.
Disconnection and removing the unserviceable pressure guage and S&F Pressure gauge 8" dial 0-21 kgs rating ISI Marked complete all as directed.
Disconnection and removing the unserviceable pressure guage and S&F Pressure gauge 4"dial 0-21 kgs rating ISI Marked complete all as directed.
Disconnection and removing the unserviceable/ broken Stainless Steel spindle along with the check nuts & gate from the Sluice valve of Size 80mm dia and M&L for New Stainless Steel Spindle of same size & capacity with Stainless Steel Check nuts including polishing, mechining, threading & necessary lathe work complete.
All as per item No 26 here-in-above but of size 100mm dia sluice valve.
All as per item No 26 here-in-above but of size 150mm dia sluice valve.
Disconnection and removing the U/S Sluice Valve 80mm dia and S & F Sluice Valve 80mm dia, IS-14846, PN 1.6, bearing ISI mark, stainless steel spindle with hand wheel head, screwed both ends for GI Pipe 80 mm dia complete all as specified and directed.
All as per item No 29 here-in-above but of size 100mm dia sluice valve.
All as per item No 29 here-in-above but of size 150mm dia sluice valve.
Disconnection and removing the U/S Non Return Valve 150mm dia and S & F Non Return Valve 150mm dia,, ISI mark, both end flanged including provn of new gasket and nuts, bolts and washers and fixed complete all as specified and directed.
Disconnection and removing the U/S CI Foot Valve and Supply & Fix CI Foot valve 100mm dia with all fittings including flanges, leather washer, fasteners for fitting such as necessary size nut bolt and washer, rubber packings / jointing materials complete including taking down the old unsv one all as specified and as directed.
All as per item No 33 here-in-above but of capacity 150mm dia CI Foot valve
All as per item No 33 here-in-above but of capacity, 200mm dia CI foot valve
Disconnection and removing the U/S CI Butterfly Valve 80mm dia and S & F CI Butterfly Valve 80mm dia, (Wafer Type) PN 1.6 stainless steel spindle with hand wheel head, screwed both ends, ISI Marked complete all as specified and directed.
All as per item No 36 here-in-above but of capacity 100mm dia
All as per item No 36 here-in-above but of capacity 150mm dia.
All as per item No 36 here-in-above but of capacity 200mm dia.
Disconnection and removing the u/s Lead Acid Battery and S&F Lead Acid Battery, 12Volt, 180 AH with Initial fully charged alongwith electrolyte and other accessories complete.
Disconnection and removing the unserviceable MCCB 250 Amps capacity and supply and fix MCCB 4 pole 36 KA 250 Amps 440 volts along with fixing arrangements.
Disconnection and removing the unserviceable MCCB 200 Amps capacity and supply and fix MCCB 4 pole 36 KA 200 Amps 440 volts along with fixing arrangements.
Disconnection and removing the unserviceable battery lead connection and M&L for battery connected leads made out of PVC Single core 1100 volts grade bunched copper conductor upto 1.5m long including one end soldered with a copper lug and the other end soldered with a brass terminal along with nut, bolt and washer complete.
Disconnection and removing the unserviceable battery lead connection and M&L for battery connected leads made out of PVC Single core 1100 volts grade bunched copper conductor upto 0.6 m long including both end soldered with a brass terminal along with nut, bolt and washer for interconnection of batteries complete.
Preparation of old painted steel and iron surfaces of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint, first quality, postal red colour, complete all as specified and as directed.
Satya Dharam Vikas Fire Safety & Security Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .