Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | L1 | Accepted-AOC accept | |
| 2 | L2₹18.2 L+₹66,412.30 (3.78%)Rejected-AOC BELOW SLAUGHTER HOUSE KRISHNA NAGER SHIMLA | SHIMLA | SHIMLA | HIMACHAL PRADESH | L2 | Rejected-AOC accept | |
| 3 | L3₹25.4 L+₹7.9 L (44.7%)Rejected-AOC | L3 | Rejected-AOC accept | |
| 4 | L4₹26.9 L+₹9.3 L (52.9%)Rejected-AOC NO 1 HPPWD DIVISION DHARAMSHALA HIMACHAL PRADESH | KANGRA | HIMACHAL PRADESH | 176001 | L4 | Rejected-AOC accept | |
| 5 | L5₹28.0 L+₹10.4 L (59.5%)Rejected-AOC 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | L5 | Rejected-AOC accept |
Tender Value
₹20.3 L
EMD Value
₹37,954
Closing Date
3 Jul 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer JSV Division Thural
O/O The Executive Engineer JSV Division Thural
HAR GHAR NAL for providing LWSS to PC, habitaions under Jal Jeevan Mission to village Buhla Manja, Garer,Gadela,Kalan, Phulwar etc covered under LWSS Lahru Bachhwai in Tehsil Palampur Distt .Kangra
2020_HPIPH_38233_1
THL-KNG05-729 ( 2734-2799 dt 19.06.2020)
Open Tender
Civil Works - Water Works
Item Rate
180 days
HAR GHAR NAL for providing LWSS to PC, habitaions
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
₹37,954
Yes
6 Apr 2021
20 Jun 2020
4 Jul 2020
20 Jun 2020
3 Jul 2020
20 Jun 2020
120 days
Amount
Excavation in foundations and trenches(for pipes and pits in all depths etc.) in all lifts and in all kinds of soils such as pick work, jumper work, blasting in soft/hard rock, chiseling/wedging out of rock (where blasting is prohibited)and saturated soils, stacking the excavated earth within all leads and lifts, clear from the edge of excavation and then returning the stacked soil in 15 cms. layers when required into plinths, sides of foundation and trenches etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by Engineer-in-charge within all leads and lifts including uprooting of trees, dressing of beds and sides and preparation of sub-grade, restoration of unmetalled/metalled/paved surfaces to its original conditions including soring, strutting, timbering and dewatering , where ever required, providing diversion for traffic, fixing night signals, fixing caution boards, crossing over trenches for access to houses complete and to the entire satisfaction of the Engineer-in-charge.
Laying, jointing with circumfrential butt welded joints by electrical arc welding ( welding thickness shall be equal to pipe wall thickness)steel flanged pipes after every 100 mtrs of pipe of following dia meters conforming to IS 1239-1990 (Part-II), having wall thickness as specified below capable of withstanding required test pressure, including manufacturing and febrication of reducers/ tapers , all short pieces, etc. as per site requirement made from parent tubes . The laying of pipe shall also include flanged joints duly welded in three layers (Two inner & one outer), where ever required as per direction of the Engineer-in-charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket will be measured and paid for separately) and all operations such as cutting, welding, jointing i.e. lowering and laying in excavated trench to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the entire satisfaction of the Engineer in charge. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The damaged portion of the pipes and all the specials ( If damaged during laying & jointing operation of pipe) made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The rates also includes entire carriage of material, flushing, cleaning of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts.
2nd stage -GI pipe 150 mm dia (MC) with wall thickness of 4.80 mm THICK(FT-28 from RD-0/0 to 250 Rmt.
2nd stage -GI pipe 150 mm dia(MC) with wall thickness of 4.80 mm Thick(FT-17) from RD-250 to 1250 Rmt.
2nd d stage -GI pipe 150 mm dia(MC) with wall thickness of 4.80 mm Thick(FT-5) from RD-1250 to 1850 Rmt.
3rd stage -GI pipe 150 mm dia( HC) with wall thickness of 4.80 mm (FT-28) from RD-0/ 0to 790 Rmt.
3rd d stage -GI pipe 150 mm dia (HC)with wall thickness of 4.80 mm (FT-17) from RD- 790 to 1210 Rmt.
3rd d stage -GI pipe 150 mm dia (MC)with wall thickness of 4.80 mm (FT-5) from RD-1210 to 1260 Rmt.
Providing MS flanges (In pairs) for the joints of G.I. pipes mentioned as below and same shall conform to BIS 6392-1971 ( latest with up to date amendments) including the cost of nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets conforming to relevant BIS standards and it shall also include carriage of materials within all leads and lifts complete in all respect to the best satisfaction and direction of Engineer in charge.
2nd stage -GI pipe 150 mm dia (MC) with wall thickness of 4.80 mm THICK(FT-28 from RD-0/0 to 1050 Rmt.
2nd stage -GI pipe 150 mm dia(MC) with wall thickness of 4.80 mm Thick(FT-17) from RD-1050 to 1250 Rmt.
2nd d stage -GI pipe 150 mm dia(MC) with wall thickness of 4.80 mm Thick(FT-5) from RD-1250 to 1850 Rmt.
3rd stage -GI pipe 150 mm dia( HC) with wall thickness of 4.80 mm (FT-28) from RD-0/ 0to 790 Rmt.
3rd d stage -GI pipe 150 mm dia (HC)with wall thickness of 4.80 mm (FT-17) from RD-790 to 1210 Rmt.
3rd d stage -GI pipe 150 mm dia (MC)with wall thickness of 4.80 mm (FT-5) from RD-1210 to 1260 Rmt.
Providing and supplying of cast steel Refulex/NRV valve of Leader /Kirloska make and of following dia for the delivery line of pump and capable of with standing the normal seat pressure and as per IS-1868/API-600 class ASA 150 with upto date amendaments.and as per direction and to the entire satisfaction of the Engineer-in-charge. 150 mm dia
Providing and fixing Screw type Cast iron Air Valve 50mm dia (Single Ball type) of Leader make confirming to BS:1452-90 with upto date amendment as per Class- 10.00 with standing a normal seat pressure of 11.22 kg/cm2 in rising main of 150 dia as per direction and to the entire satisfaction of the Engineer-in-charge.
Dismentling of existing R/main 150 mm dia complete in all respect and as per direction and to the entire satisfaction of the Engineer-in-charge.
Submersible P/Mach:- Booster stage (Sump well to Raw water tank) Supply of submersible pumping set of KSB /Calama /SU/ Johnstion/kirloskar/Sabber/Hindostan make comprising to latest relevant BIS Code. The pump should be fitted with bronze impeller of suitable alloys as per IS 8034-1978 latest suitable for clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900 of reputed make conforming to BIS 9238-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips and depth gauge etc. and suitable for operation on data given below:-2 Nos. pumping sets complete i/c allied accessories 25 HP
SITE CONDITIONS:-,I, Location of site:- The site is located at a distance of 26 Km. fromPalampur Maranda Railway station on Thural Sujanpur Road,ii,The altitude of place in which the motor is intended to work in ordinary service.1000.00 Meter above MSL,iii,Humidity:-Humid during rainy season,iv,Nature of atmosphere:- Normal ,v,Detail of quality of water:- clear water of S/well.,vi,Water free from sand or not:- Free from sand,vii,Water corrosive or not:- Not corrosive,viii,Turbidity:- Less than NTU,ix,Type of well:- spring source,X,Inside dia of Well:-Meter dia,xi,Depth of water during HFL in the well – meters,xii,Maximum draw down:- meter,xiii,Depth of well:- 3.00 meter,iv,Any other information if required.
OPERATING CONDITIONS,I,Type of current:- AC Three phase,ii,Operating frequency 50 Hz.,iii,Rated voltage 400(+/-) ,iv,System of earthing if any to be adopted :Double Loop earthing as per BIS:3243-1987 latest with.,v,Speed of revolution To be quoted by tenderer.,vi,Direction of rotation To be quoted by tenderer.,v,No. of working hours per day. 20 Hour,vi,The maximum temperature of cooling air and water in the place in which the pump set is intended to work in ordinary service Temperature of place to be specified 20 degree to 42 degree centigrade
MOTOR,I,Ref. to BIS code BIS 9238-1979 with upto date amendments,ii,Type of enclosure of motor As per BIS-4691-1985 (Latest),iii,Type of duty : Continuous,iv,Mechanical output in KW Suitable for driving submersible pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated output to prime Mover.,v,Class of insulation Class –B,iv,Max. permissible temp. rise of motor reqd. if different from that given in 8 (viii) above.,vii,Particulars of test reqd. & where they are to be conducted. To be specified by the tenderer. As per terms and conditions attached.,viii,Particulars as to whether voltage limiting device will be employed. Oil immersed star delta starter to be installed between bus bar and motor. Shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 KW,xi,Type of motor Star Delta Starter upto 37.5 KW as per BIS:9283-1979 or latest.
Details of shaft extension required,I,Break way torque in terms of rated load torque and the corresponding break-way starting current which may be taken from the supply with the starting apparatus in circuit should notexceed 2.5 times of the full load current,ii,Nature of load and any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated and No. of starts during a specified period.,iii,Where possible fault capacity of the system to which the motor is connected. The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
PUMPS,I,Nos. of pumps required. 2 Nos. pumps out of which one set will work at a time and one set will act as stand bye.,ii,Spare parts required. For two years normal maintenance as recommended by manufacturer,iii,Type of drive. Electric induction motor,iv,Optional fittings required
Pump Operating conditions:- I,Discharge. -15.21 LPS for each pump,ii,Total head in meters 41.14 meter,iii,Static head 36.87 meters.,iv,Minimum depth of water,v,Variation in water level,iv,Ground level to Max. water level,v,Ground level to delivery point,vi,Pressure in the suction tank.,v,Pressure in the delivery tank ,vi,Length of rising main 195 Meters,vii,Dia of rising main -150mm dia,vii,Turbidity of water < than 50PPM,viii,Drive type Electric driven,ix,Limits of total head in which the pump is required to operate. (-) 15% to (+) 10% of total head,x,Suction/Delivery size of pump,xi,Efficiency of pump at,xii,a) Duty head,xiii,b) (+) 10% head.,xiv,c) (-) 15% head,xv,Material of construction To be specified by the tenderer (manufacturers certificate to be appended)
Supply, instailation, testing and commissioning of PLC based Fully Autometic PLC based LT Panel for submeresible pump made out of 16 Gauge sheet powder coated dust and veremin prooof wall mounted and front opering door type switch board with copper insulated wiring suitable ot operate 2 nos. pump autometically as per site requirement along with sluice valve as pr design timing which can be acted as and when required one at a time or together as per requirement through PCl panel (CPRI approved, with 50 KA Short Circuit and IP -55 protection duly insuiated with heat shrinkable sleeve as per colour, supported on epoxy insuator 01 set, common earth bus of 25mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable gland with independent plate at bottom and complete panel board pointed with powder coatng in gray colour all as Spcified & directed make of fpanel board: Dvepl. aspl/tricolite. The Panel board should also have following items:-
Main MCB-63 A,3 phase 415 Volt.
Amp meter 060 A with CT 60/5..
Volt meter with VSS-0500V.
R-Y-B indicating lamp..
Toggle Switch
Star delta timer.
Motor protection relay consisting of single phase preventor,phase revarsal protection ,under/over voltage protection ,over load protection.
Control MCB-6A-SP.
On/Off indicator and push buton.
Control and power wiring.
Power capacitor 4 KVAR.
Control Terminal ,Bus bar ,ie Bolt,insulator ,etc.
LED 5 watt.
Cooling fan 230 VAC.
Hour meter.
Supply of Kirloskar/leader make cast iron double flanged sluice valve class PN-1.00 (to be provided on delivery side )of size higher than the delivery size of pump and and capable of with standing nominal seat pressure of of 21 kg /cm2 with latest with upto date ammdnents .Note:- The C.I sluice valve shall conform to BIS 780-1984 for 50 to300 mm dia & BIS 2906-1984 for 350 to 1200 mm dia(latest adition)however If seat pressure exceeds the limits prescibed in above mentioned BIS.Than it shall be of Cast steel conforming to class ASA-150 for seat pressure upto 21 kg/cm2 or class ASA-300 for seatpressure 21 kg/cm2 as BS 1414(API600)
Supply of Kirloskar/leader make cast iron double flanged ( swing check type) reflux valve class PN-1.00 having bye pass arrangement (to provided on delivery side )of ize one higher than the delivery size of pump & shall be suitable for with sanding nominal seat pressure of 21 kg/cm2 of class ASA-150 asper BS-1868API(600).
Supply of Kirloskar/leader make cast iron double flanged ( swing check type) reflux valve class PN-1.00 having bye pass arrangement of size equal rising main i.e.150 mm dia and shall be suitable withstanding nominal seat pressure of 21kg/cm2 class ASA 150 as per BS:1868-API-600.Note:- The C.I reflex valve shall conform to BIS 5312-1984(Part-1 ) latest with up to date ammendments. However If seat pressure exceeds the limits prescibed in above mentioned BIS. 5312-then the reflex valve shall be cast steel conforming to class ASA-150 for seat pressure upto 21 kg/cm2 or class ASA-300 for seat pressure 21 kg/cm2 as BS 1868(API600)
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments siemen/closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer.
Supply side 3 1/2 core (from HPSEB meter to switch & starter): 6mm2 cable Min length = 15 mtrs.
Motor side 3 core (From switch & starter to motor): 4mm2 cable Min. length = 30 mtrs.
Providing and fixing double loop earthing and G.I. plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm G.I. strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).3 KVR, 2x6=12 KVAR
Supply of standard make circular dial pressure gauge 0-10 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments.
Providing and laying of GI/MSERW pipe considering site requirement and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevent BIS codes & capable of with standing the field test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers / reducers, flanges, rubber guskets 3 mm thick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. NOTE :-Actual laying to be done final drawings to be approved by the Engineer in charge. Common Header
Erection charges for all items complete including cost of tee bends tapers and any other fitting with flange required and as per site conditions and as per direction of Engineer-in-charge.
SUNIL KUMAR
NARESH KUMAR GOVT CONTRACTOR
Shadil Thakur
sanjeev kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .