| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.4 L+₹2.7 L (8.78%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Jan 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-55/2019-20 MANNING AND OPERATION OF PUMP SETS, DG SETS, STP, REPAIRS TO WATER SUPPLY LINES, UG SUMPS, SWTs, ELECTRICAL INSTALLATIONS, INTERNAL ELECTRIFICATION, CEILING FANS, COOLING APPLIANCES, DESERT COOLERS, VOLTAGE STABILIZERS,
2020_MES_311145_1
GE AF/AMB-55/209-20
Open Tender
Civil Works
Item Rate
330 days
GE AF AMBALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE AF AMBALA
₹80,000
Yes
12 Feb 2020
2 Jan 2020
31 Jan 2020
2 Jan 2020
29 Jan 2020
16 Jan 2020
Amount
Manning & Operation of water supply installation and STP by providing 01 FGM each in 03 (three) shifts (each shift of 8hours) on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge: (a) Submersible pump set of capacity upto 40HP electric driven complete with LT panel, starter and sluice valves, etc. complete for boosting/shifting the water in OH reservoir, etc. (b) Operation of chloronome plant and bleaching dozer of any type as per requirement while pumping the water to reservoir (c) Operation of standby DG set installed in the same pump house for standby supply to the pump set as required basis on main electric supply failure, etc. (d) Operation of sewage treatment plant including all items viz. submersible motor, boiler motor through electric panel complete
Manning & Operation of sub-station with DG set 160kVA including attending internal and external electric complaints of HT/LT electrification including street lights, perimeter lights, etc. by providing 01 (one) qualified electrician, in 03 (three) shifts of 8hours each (round the clock 08hrsx3 shifts = 3 electricians) on all days including Sundays and holidays for domestic / technical area complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation for sub-station with DG set 160kVA including attending internal and external electric complaints of HT/LT electrification, including street lights, perimeter lights, etc. by providing 01 (one) mate working as helper each in 01 (one) shift of 8hours on all days including Sundays and holidays for domestic area complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Notes for serial item Nos. 1 to 3: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) 'NIL'or 'Zero' quoting of rates against any items will be treated as 'Non Bonafide'. (iii) The rate quoted shall not be less than minimum fair wages as notified by the Government of India / State Government / Local bodies / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable. In case, the rates quoted by the bidder are less than the minimum fair wages as notified by the Government of India / State Government / Local body / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, his tender will be treated as 'NON BONAFIDE' and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only.
(iv) The minimum wages as derivied by the Deartment including all statutory provision such as ESIC, Bonus, GST, taxes, etc. except the Contractor's profit for skilled person works out to Rs. 705/-per person per shift and for un-skilled person Rs. 552/- per person per shift (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase will be passed over to the workers
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc.not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc.not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
M&L for plain cement concrete type C-1,1:3:6 (using 20mm graded stone aggregates) in copings to poles, padding, PCC bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, etc. including necessary formwork complete all as specified and as directed
S&F 2 core 16sqmm XLPE insulted armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by and including insulated hangers @ 1m c/c and 4mm dia suspension wire includng taking down old unserviceable cable and disposing off complete all as specified and as directed
Supplying, laying / fixing, testing and commissioning of electric cable 1100V grade aluminium conductor XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, having C-1.1 solid aluminium conductor (upto 10sqmm) and C-1.2 stranded or compacted shaped aluminium conductor (above 10sqmm) as per IS-8130-1984, XLPE insulation, PVC tape inner sheath conforming to IS-1554 (Part-I)-1988, PVC type ST-1 outer sheath conforming to IS-5831-1984 including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, bricks, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
3.5 core 120sqmm
3.5 core 95sqmm
3.5 core 50sqmm
4 core 25sqmm
4 core 16sqmm
Supplying, laying / fixing, testing and commissioning of electric cable 11kV grade 3 core 95sqmm aluminium conductor XLPE insulated, galvanised steel armoured power cables conforming to IS-7098 (Part-I)-1988, XLPE insulation, earthed including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed Note: Excavation/earthwork, brick covers, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to PCC/steel poles 9/11m high/long with two coats of synthetic enamel paint in black & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
Supply, install and erect in position pre-stressed concrete pole, 9m long, 102x152mm at top and 102x289mm at bottom, class 10 including taking down and disposing of old concrete pole complete all as specified all as directed Note: Excavation / earthwork and PCC coping etc. will be measured and paid separately under respective items herein
M&L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed
M&L in repairs for stringing of aluminum conductor steel reinforced (ACSR), wesel type, stringing properly on insulators and binding with aluminum binding wire, jumpers, etc. complete all as specified and as directed
S&F in repairs swing out expulsion fuse assembly single pole (drop out fuse) for 11000V of capacity 100Amps with MS channel, post insulators, etc. complete all as specified and as directed
M&L for taking down insulators of any capacity / type from any locations / position and disposing off complete all as specified and as directed
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, 02Nos. galvanised iron washers and 01No. galvanised iron nut, 100mm height 65mm dia for 1100V grade complete all as specified and as directed
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, 02Nos. galvanised iron washers and 01No. galvanised iron nut, 100mm height 65mm dia for 11000V grade of size 150mm dia and 150mm long complete all as specified and as directed
S&F shackle type porcelain vitreous white insulator, 1100volt grade, 75mm in height and 90mm dia including galvanised mild steel strap of size 31x3mm, 12mm dia insulator bolts, washers and nuts complete all as specified and as directed
S&F disc type insulators, porcelain vitreous 145mm high and 255mm dia, ball and socket type, white / brown / green, working pressure 11000V for fixing as single disc assembly on existing lines complete all as specified and as directed
M&L for stay assembly with accessories as shown in electrical plate No. 1 of SSR Part-I, using stay rod of 16mm dia, stay plate 6mm thick of size 300x300mm including stay wire 7/2.5mm dia of suitable length complete all as specified and as directed Note: Excavation/earthwork and PCC shall be measured and paid separately under relevant item herein
Restringing ACSR conductor, straightening properly on insulators and binding with aluminum tape /binding wire/conductor, jumper, etc. complete all as specified and as directed
S&F seperators, screw type on LT OH lines for 4 wire LT system, complete all as specified and as directed
S&F seperators, screw type on LT OH lines for 2 wire LT system, complete all as specified and as directed
S&F battery, lead acid, 180AH 12V, set including initial charging, filling of distilled water, etc. including connecting lead and testing on installation and dsiposing off old battery complete all as specified and as directed
M&L for cleaning & utility servicing HT Vacuum Circuit Breaker (VCB), 11kV (indoor type), 400/630Amp, 3 phase, checking of each moving parts, spring charging system, triping system, indication system, metering system, remote operation, closing & trip coil assembly and proper oiling, greasing and proper adjustment of trip bars, closing bar complete with the following testings complete all as specified and as directed (i) ON/OFF testing in local and remote position (ii) Spring charge system (iii) Tripping test in overload and earth fault position by external current injecting Kit on both primary & secondary sides (iv) Meggar testing between phase to phase and phase to earth in ON / OFF position both (v) Calibration of earth fault / over current relay Notes: (a) Tests shall be carried out through atuhorised service center (b) All the test reports shall be submitted to the Engineer-in-charge and shall be made part of RAR / FB
M&L danger notice plates, for LT of size 20x15cm, made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts complete all as specified and as directed
Supply, fixing, connecting and testing spring charging motor (universal motor) for outdoor type, 11kV, VCB, operated on 230V AC/ DC, with charging time less than 15seconds of approved rating complete all as specified and as directed
S&F shunt trip coil assembly suitable for HT, OCB/ VCB, operating on 24/110V system and testing complete all as specified and as directed
S&F closing coil operated on 110/24V system suitable for working of relay of HT OCB / VCB complete all as specified and as directed
S&F under voltage coil assembly suitable for HT OCB/ VCB operated on 110/24V system and testing complete all as specified and as directed
S&F in repairs indication lamp (LED type) Red / Yellow / Green colour suitable for 110V AC / 110V DC / 30V DC (as required at site) complete all as specified and as directed
S&F electric heater suitable for VCB as per existing size and capacity complete all as specified and as directed
M&L for repairs to fire hydrant post 80/65mm size by replacing the unserviceable MS pipe, MS bend, male/female brass coupling including testing on completion complete all as specified and as directed
M&L for switch air break gang operated, tripple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200Amps 11000V grade with 12 insulators with drop out fuse assembly including 25mm dia GI medium grade pipe, supports worked from ground level vertically operated including taking down old unserviceable switch from existing place and disposing off complete all as specified and as directed
M&L for carrying out tests for locating faults in HT cable of any size with the help of fault locator machines, etc. complete all as specified and as directed
M&L for taking out defective UG cable of any size and relaying the same after rectifying the fault, inserting jointing kits of suitable size as required and relaying old sand and brick protection covers complete all as specified and as directed Note: Jointing kit, excavation / earthwork will be measured and paid separately under relevant items herein
S&F current transformer (CT) suitable for 11kV of capacity 100/50/5Amps complete all as specified and as directed
S&F current transformer (CT) suitable for 11kV of capacity 50/25/5Amps complete all as specified and as directed
S&F lightening arrestor, expulsion type, 65kA discharge capacity transmission class, suitable for 11kV system including staging as required complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 63Amps 16kA fixed type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 125Amps 25kA fixed type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 200Amps 36kA fixed type complete all as specified and as directed
M&L for taking out burnt HT/LT winding complete, from transformers, etc. cleaning all the limbs, replacing with new winding with super enemelled copper wire of same specification, varnishing by vacuum impregnating, replacing insulating material, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs LT side stud of gun metal / brass metal of suitable size of existing specification and make for transformer of capacity 100 to 315kVA at site including nuts, washers, gasket, bushes, etc. complete all as specified and as directed
S&F in repairs HT side bushes of existing size, specifications and make of equipment complete all as specified and as directed
S&F in repairs HT/LT bushing rubber (ring) gaskets set of transformer complete all as specified and as directed
S&F in repairs transformer top gaskets (cork sheet) set of transformer complete all as specified and as directed
S&F in replacement silicagel of existing specification complete all as specified and as directed
Supply & filling the transformer oil (as per IS 339-1989) breaking down capacity more than 50kV to replace/topping up low breaking down capacity oil in at site including filteration & dehyderation complete all as specified and as directed
M&L for filteration, dehyderation and checking of transformer oil including necessary connection, testing, etc. on refilling / re-pouring into equipments complete all as specified and as directed
M&L for disconnecting, dismantling and removing transformer of capacity 100 to 315kVA, any make / any type (indoor/outdoor) from any locations / site, transporting the same to workshop, opening, draining out oil, taking out core assembly in the presence of JE/Engineer-in-Charge and estimating the repairs of damaged parts, cleaning /washing of tank removing the dirt sludge and sticky materials from all parts of the transformer including core tank and cooling tubes, removal of damaged parts, re-assembling after replacement of damaged parts of the transformer after repairs including preparation of old surfaces and painting with two coats of synthetic enamel paint (grey tint) on entire outer surfaces, writing transformer number, etc. making all connections and refilling with serviceable drained out transformer oil and carrying out requisite testing including reinstallation of transformer at site complete all as specified and as directed Note: Rate quoted shall be inclusive of cost of all de-installing, loading / unloading, carting, reinstalling, etc. to and fro from site to workshop
M&L for taking down old street light / security light fittings and refixing after necessary repairs including cleaning of perplex covers, etc., tightening of loose connections on poles / walls, and replacing and dead bulb / tube rod, worn out minor parts, etc. and making the fitting functional complete all as specified and as directed Note: Minor parts, bulb/tube rod shall be measured and paid separately under respective items herein
S&F tubular type lamp 70W suitable for HPSV street light fittings complete all as specified and as directed
S&F tubular type lamp 150W suitable for HPSV street light fittings complete all as specified and as directed
S&F tubular type lamp 250W suitable for HPSV street light fittings complete all as specified and as directed
S&F tubular type lamp 400W suitable for HPSV street light fittings complete all as specified and as directed
S&F choke (ballast) copper wound, suitable for HPSV/MH 70W street light fittings complete all as specified and as directed
S&F choke (ballast) copper wound, suitable for HPSV/MH 150W street light fittings complete all as specified and as directed
S&F choke (ballast) copper wound, suitable for HPSV/MH 250W street light fittings complete all as specified and as directed
S&F choke (ballast) copper wound, suitable for HPSV/MH 400W street light fittings complete all as specified and as directed
S&F electronic igniters suitable for HPSV street light fittings 70 to 400W complete all as specified and as directed
M&L for removing / scrapping of old worn out paint from LT panels / feeder pillar boxes by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
S&F 1.5m long 25mm bore light grade GI pipe bracket duly cut to size and bent to shape required duly painted with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, including 2Nos. MS clamps as required to fix on concrete / steel poles and taking down and disposing off old unserviceable brackets complete all as specified and as directed
S&F in repairs 3 core PVC insulated and PVC sheathed copper conductor cable 2.5sqmm nominal size from main lines to street light fitting of different types complete all as specified and as directed
S&F in repairs aluminum cable of size 10sqmm 2 core in connecting up fittings, etc. complete all as specified and as directed
S&F LED street light fitting, 90W, 230V, 50HZ, suitable for operation over voltage range of 140V to 270V, duly housed in pressure die cast aluminium housing, compressing of LED with individual optical lens, electronic driver with IP 66 protection and impact reistance of IK 07, including connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting and taking down and disposing off old unserviceable fitting complete all as specified and as directed
S&F LED post top light fitting 25Watt, powder coated, die cast and spun aluminium with clear opel diffiuser suitable for landscape lighting (of approved shape / model) complete all as specified and as directed
S&F junction box thermoplastic polycarbonate enclosure, shock proof, IP66/IP67 (weather, rust, dust, water and vibration proof, internally embedded gasket with provision for all side cable entry through glands (IP-68) of size 300x250x200mm with suitable connecters for 3Ph/1Ph loop in/ loop out and branch out connections including 01No. 6Amp MCB 10kA for controlling security lights complete all as specified and as directed
Servicing of DG set of capacity 63 to 160kVA at site including, cleaning of diesel tank internally thoroughly with water and air pressure, removing the sludge from the tank, opening of oil chamber cover, draining out used engine oil, cleaning the chamber throughly internally and refixing the chamber cover, taking off and replacing worn out / unserviceable parts and making DG set functional including all testing on full load, etc. complete all as specified and as directed
Supply and pouring fresh coolant
Supply and pouring fresh lubricant engine oil
Replacement of lubricant oil filter element
Replacement of fuel filter element
Replacement of by-pass filter element
Replacement of air cleaner filter element set
Replacement of high pressure diesel pipe including bolts, copper washer, etc.
Replacement of high pressure engine oil pipe including bolts, copper washer, etc.
Replacement of oil safety switch of existing capacity and make
Replacement of starting switch suitable for 63 to 160kVA DG sets
Replacement of pressure gauge suitable for 63 to 160kVA DG sets
Taking out radiator assembly from DG sets, of capacity 63/163kVA, carefully and servicing, cleaning the same internally as well as externally with chemical, cleaning the fins throughly, replacing worn out spares and refixing the same at its original position and testing complete all as directed Note: Spares / parts replaced will be measured and paid under relevant items herein
Replacement of fan belt of existing size/make of DG set capacity 63/163kVA
Replacement of water pump of existing size/make of DG set capacity 30/63/160kVA
Replacement of solenoid coil of requisite capacity and testing
S&F in repairs battery charger 240V 50Hz charging range 6 to 24volt with trickle / boost charging mode complete all as specified and as directed
M&L for servicing self starter of capacity 12V suitable for 63 to160kVA DG set, reparing the same by rewinding armature, field coil, replacing the pinion, carbon brush and fixing at its original position and testing on completion complete all as specified and as directed
M&L for servicing and repairing AMF panel for 160kVA DG set at site including changing of contactor (2NO+2NC BCH15 T22 BCH 15) and relay (MC320KE32 MD DMD control relay) and all other minor unserviceable spares/items and making the panel functional complete all as specified and as directed
M&L for repairs to boiler of sewage treatment plant as per existing capacity and make by replacing the defective parts and checking and testing on installation through and by authorised company including changing of pipe and connected items and minor parts/spares as required for proper functioning of the equipment complete all as specified and as directed
M&L for servicing relay /contactor of STP electric panel, checking out of electric supply, proper functioning with load balance on RYB phase incuding checking of boiler motor and repairing/replacing minor spares / parts for proper functioning complete all as specified and as directed
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 11kV earthed grade cable heat shrink type joint with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor/outdoor straight through / end termination type, for 1.1kV earthed grade cable heat shrink type joint with jointing material and accessories suitable for 3.5 core, 35 to 120mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth wire 4sqmm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed Notes: (i) The cost of GI earth continuity conductor with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item
M&L for repairing existing earthing by construction of earth pit with wire mesh, funnel, providing new CI cover, soldering/brazing/fastening of earth lead, fixing post insulators, providing earth strip of GI earth wire 32mm size upto 2m length and testing for serviceability complete all as specified and as directed
M&L for repairing existing chemical earthing system consisting each set 02/03 filling of back fill/JAM compound in 50mm dia bore in immediate contact around the earth electrode and the rest of the bore shall be fitted with well compacted earth and top of the bore shall be finished and back fill/JAM compound upto depth of 10feet including replacement of nut bolts of brass and brazing of ligntening arrestor & copper strip complete all as specified and as directed Notes: (i) The earthing shall comply to IS 3043, UL 467, BS/EN 50164-7 (ii) The earth resistance shall be less than 1ohm (iii) Testing of the earth shall be carried out in presence of rep of AO and a reports shall be submitted, by the Contractor. (iv) The quoted rate shall also include all required earthwork in any type of soil
Taking up or down steel water tubing and connections and disposing off, etc. complete all as specified and as directed for the following bores:
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS: 1239 fixed to walls / ceilings or laid in floor / trenches complete all as specified and as directed of the following bores:
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
M&L in replacement for CI specials for spigot and socketed pipes, such as tee, bends, collar, tapers, adopter, tail pieces, etc. any type, size and radius & shape as per IS specification size up to 200mm dia complete all as specified and as directed Note: Excavation / earthwork and lead joints shall be measured and paid separately under respective items herein
M&L for run lead joints for 80mm bore cast iron pipes including jointing material like spun yarn, etc. complete all as specified and as directed
M&L for run lead joints for 100mm bore cast iron pipes including jointing material like spun yarn, etc. complete all as specified and as directed
M&L for run lead joints for 150mm bore cast iron pipes including jointing material like spun yarn, etc. complete all as specified and as directed
M&L for flanged joints for 100/150mm bore cast iron pipes including nuts, bolts, washers, rubber / fibre board gasket, etc. complete all as specified and as directed
S&F sluice valve cast iron body class PN 1.0 marked both ends fanged with brass spindle and brass check nuts with cast iron hand wheel including jointing material like rubber insulation sheet 3mm thick, bolts, nuts and fixed to pipe line, including testing on installation and taking out / down and disposing off old / unserviceable sluice valve complete all as specified and as directed of the following sizes:
150mm dia
100mm dia
80mm dia
M&L for caulking of joints in existing CI pipes by pouring lead to required quantity and making the joints leak proof including bailing out leaking water by using sludge motor, etc. and excavation and earthwork in any type of soil or cutting or breaking into road/ interlocking tiles/cement concrete, etc. and making good the disturbed surfaces for the following sizes of pipe:
150mm bore
100mm bore
80mm bore
S&F in repairs gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, and earthwork in any type of soil or breaking/cutting into road/interlocking tiles/cement concrete, etc. and making good the disturbed surfaces complete all as specified and as directed of the following sizes:
50mm bore
40mm bore
25mm bore
20mm bore
Taking up cast iron water mains (including all fittings) with spigot and socketed ends and lead joints including burning out lead from joint and recovering lead and disposing off complete all as specified and as directed
80mm bore
100mm bore
150mm bore
M&L for CI pipes with socketed and spigot ends suitable for tyton joints centrifugally cast (spun) class LA conforming to IS:1536 cut to any length and laid in trenches including rubber gaskets joints complete all as specified and as directed of the following sizes: Note: Fittings shall be measured and paid separately under respective items herein
80mm bore
100mm bore
150mm bore
S&F GI column pipe 100mm dia, medium grade with 02Nos flanged fixed at both ends, 10feet long and fixed complete all as specified and as directed
M&L for removing / taking out non-clog type submersible sewage pumping set capacity upto 15HP from sewage well, with column pipe, duck foot bend etc., dewatering all sewage water with pump lifting, dismantling the pump for assessing and making good for running conditions by repair / replacement of all unserviceable spare parts like upper lower bearing, seal assembly, bottom plate, cable gland, neoper cable protector, cable seal, cable clamp and screw, plug joint ring, gasket neoper, circlip spring, impeller key, impeller nut, electronic timer, eye bolt, etc. as required and replacement of O ring set, full fasteners set & Nitrile `O` ring set, checking of all bearings & mechanical seal by cleaning greasing and reassembling the same including hydraulic air testing and balancing, changing of lubricant oil, re-assembling, lowering the same into the sewage well and making necessary connections, testing complete all as specified and as directed
M&L for taking out column pipe, flanged 100/80mm bore with 2Nos submersible cable from bore well alongwith pump set of any capacity in any locations / positions for carrying out repairs to pumps, motor, spares, cabling, etc. and again lowering in position including posisioning and fixing of the pumps, etc. complete all as specified and as directed Note: Rate quoted shall be inclusive of: (i) All T&P required for taking out / lowering of pipe lines (ii) Repair/replacement of spares/parts of motor/pump, submersible cable, will be measured and paid separately under respective items herein
M&L for carting submersible water pump set of capacity 20 to 35HP 3 Phase 415V from site to workshop, dismantling pump set, taking out burnt winding wire from 6"/8" dia motor and rewinding with suitable size PVC coated copper winding wire as per existing wieght and pattern, including all insulating material, repair/replacement of unserviceable parts required like sealing kit, O ring gasket water drain plug, sand guard, cable packing, cable gland ring, upper/lower bearing, adopter piece, motor key upper/lower flange, neck ring, bowl stud section case, hex bolt, circlip washer, motor/pump coupling, bowl stud, motor / pump bush, etc. and reassembling pump set, tesing and commissioning pump complete all as specified and as directed Note: Rate quoted shall be inclusive of cost of all de-installing, loading / unloading, carting, reinstalling, etc. to and fro from site to workshop
M&L for rewinding of motor 15HP of non-clog type submersible sewage pumping set with suitable size of PVC insulated copper winding wire including all insulation material & motor winding provided with thermal switches for protection against excessive temperature rise complete all as specified and as directed
M&L for cleaning of internal surfaces of RCC overhead tank of 50000 gallons capacity including staging to a height approx 40 to 60 feet, etc. by scrubing the surfaces with the help of coir brush, jute cloth and flushing out all the accumulated mud / silt inside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enemal paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed
M&L for desilting and cleaning of sewage wells of depth 10m to 12m, using mechanical pumps, diesel driven, with fuel, operator, etc. and all necessary tools / plants including loading and carting off the drawn sludge, waste material, scum, spoil water, etc. outside MD land through designated sludge carriers / bio tanks complete all as specified and as directed
Supply only chlorination chemical highly efficient (high strength) calcium based granular disinfectant, more stable than chlorine gas, highly stable, in sealed container to check no sodium, iron/mercury/heavy metal contaminations, etc. complete all as specified Note: (i) Paid vouchers of calcium based granular disinfectant shall be submitted (ii) The calcium based granular disinfectant shall be brought at site/store in sealed plastic container of appropriate capacity / size asked (iii) The brand of chemical shall be as approved by the GE
M&L for taking out old unserviceable existing chlorination dozing spare parts from dozing plant and repair/replacement of the unserviceable spare parts as per existing type and size like NRV, suction/delivery pipes of existing length and type/size with fixing arrangement, motor required, filter for making dozing system functional and testing and commissioing including disposing off all unserviceable taken out parts / components complete all as specified and as directed
M&L for draining out entire water from open underground static water tanks 10000 gallons capacity, cleaning of all accumulated sand, sandy mud, insoluble particles, silt, etc. inside the tank, with the help of coir brush, jute cloth and flushing out/wiping off clean and applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. complete all as specified and as directed
S&F star delta starter 415V 3phase suitable for monoblock /submersible motor of capacity upto 40HP including all necessary contacts, relays, under/over voltage protection, single phase preventor including fixing arrangement like clamp, nuts & bolts of suitable sizes and taking out old unserviceable starter of any type and disposing off complete all as specified and as directed
S&F star delta starter 415V 3phase suitable for monoblock / submersible motor of capacity upto 20HP including all necessary contacts, relays, under/over voltage protection, single phase preventor including fixing arrangement like clamp, nuts & bolts of suitable sizes and taking out old unserviceable starter of any type and disposing off complete all as specified and as directed
S&F CI non-return valve of size 150mm conforming to IS-1538 with ISI marked Tee ( equal or unequal) dead flanges/plug, connecting pieces, tapers, collars, reducers, etc. and testing on fixing including taking out old unserviceable valve and disposing off complete all as specified and as directed
S&F CI butterfly valve of size 150mm conforming to IS-1538 with ISI marked Tee ( equal or unequal) dead flanges/plug, connecting pieces, tapers, collars, reducers, etc. and testing on fixing including taking out old unserviceable valve and disposing off complete all as specified and as directed
S&F PVC cable submersible flat/round copper 3 core 16sqmm 1100V grade, ISI marked for pumps complete all as specified and as directed
S&F impeller of existing size suitable for submersible pumping set complete all as specified and as directed
Taking down carefully batten type copper / alluminium point wiring including fittings such as light fittings, sockets, switches, ceiling roses, regulators, board outlets, etc., and disposing off including making good the disturbed surfaces with its original specifications complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed in walls / roofs / floors / ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one switch
One bell point controlled by one bell push
One switch socket outlet 3 pin 5Amps on independent board
One switch socket outlet 3 pin 5Amps on same board
M&L for point wiring complete with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, concealed in walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly for 3 pin 15Amps switch socket power point on independent board complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories surface on walls / roofs / floors / ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one switch
One bell point controlled by one bell push
One switch socket outlet 3 pin 5Amps on independent board
One switch socket outlet 3 pin 5Amps on same board
M&L for point wiring complete with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, surface on walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly for 3 pin 15Amps switch socket power point on independent board complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5amps, 240V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 5amps, 240V with cover plate complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 15amps, 240V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 15amps, 240V with cover plate complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 5amps flush type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 5amps modular type, with cover plate, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, multi-purpose, 3 pin, 15Amps, and 1 pin 5Amps, flush type, ISI marked, 240V controlled by one switch complete all as specified and as directed
S&F socket outlet, multi-purpose, 3 pin, 15Amps, and 1 pin 5Amps, modular type, with cover plate, ISI marked, 240V controlled by one switch complete all as specified and as directed
S&F switch socket combination outlet, multi-purpose, 2 in 1, 3 pin, 5Amps, ISI marked, 240V controlled by one switch complete all as specified and as directed
S&F switch socket combination outlet, multi-purpose, 2 in 1, 3 pin, 15Amps, ISI marked, 240V controlled by one switch complete all as specified and as directed
S&F bell push flush button type, 5Amps, 240V complete all as specified and directed
S&F bell push modular type, with cover plate, 5Amps, 240V complete all as specified and directed
S&F PVC lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and directed
S&F bell buzzer, ding dong type, 240V, single pole complete all as specified and as directed
S&F electronic fan regulator, stepped type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F electronic fan regulator, stepped modular type (5 steps), 100W, 50Hz, 230V, ISI marked with cover plate duly connected up complete all as specified and as directed
M&L for sub-main wiring with two runs of 4sqmm, single core PVC insulated, heavy duty, ISI marked, FRLS, unsheathed cable, 1100V grade, multistranded copper conductor drawn through and including 25mm dia non-metallic rigid PVC conduit with conduit accessories concealed /fixed to walls / roofs / floors, etc. and one run of PVC insulated, heavy duty, ISI marked, unsheathed cable 1100V grade 4sqmm for earth continuity copper conductor including taking down of old submain wiring and making good the disturbed surfaces to match with the exisiting surfaces complete all as specified and as directed Note: 3 runs of 4sqmm conductor and one run of PVC conduit shall be measured as one length
S&F sheet metal enclosure, SPN, with two pin and earth plug and socket with and including 1No. MCB SP 20Amps, 240V, 'C' series on walls including making electrical incoming and outgoing connections with lugs / thimbles complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 415V triple pole and neutral 4 way double door, flushed inside the wall with 100Amps rated busbar including making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 240V single pole and neutral 8 way double door, flushed inside the wall with 100Amps rated busbar including making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F repairs sheet metal enclosures for MCB distribution board 240V single pole 4 way double door, flushed inside the wall with 100Amps rated busbar including making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F isolator triple pole and neutral, 415V, 32 to 63Amps 10kA complete all as specified and as directed
S&F isolator single pole and neutral 240V, 5 to 40Amps 10kA complete all as specified and as directed
S&F isolator single pole, 240V, 6 to 32Amps 10kA complete all as specified and as directed
Taking down carefully exhaust fans (with or without louvers) of 300/380/400mm sweep from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, removing old worn out paint from fan and blades by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and sutable sized font) in body of fan, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed
Taking down carefully ceiling fans, 1200/1400mm sweep from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, removing old worn out paint from fan and blades by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and sutable sized font) in body of fan, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed
M&L for taking out burnt winding of exhaust fans of size 300/380/450mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
S&F PVC 3 core chord, flexible copper insulated cable 24/0.2mm size black/grey in colour and fixed / laid complete all as specified and as directed
Supplying, fixing and testing PVC exhaust fans, 250mm sweep, with louvers, 230V AC supply and connecting up with and including 3 core flexible copper cable up to ceiling rose and fixing / grouting with nuts, bolts, etc. as required complete all as specified and as directed
S&F LED 1x18W batten tube light fitting, wall mounted, extruded heat dessipation, integrated, 230V with connector block, etc. internally pre-wired and connecting up with twin core twisted flexible copper conductor cable of suitable size with all accessories complete all as specified and as directed
S&F LED light fitting 34W of size 2'x2' environmental friendly new generation aesthetically designed, ultra modern recess mounting luminaire with high bright LED light suitable for false ceiling grid complete all as specified and as directed
S&F 18W photon ultra LED tube rod, ultra bright LED with very high efficacy suited for installation in existing tube light fitting / G13 lamp holder to complete all as specified and as directed
Disconnecting from mains and water inlets / outlets and taking down carefully storage water heaters / geysers 25 / 35litres capacity, for carrying out required repairs viz. replacing worn out parts, cleaning the same, re-fixing in position, connecting up to power and water lines, testing on re-installation complete all as specified and as directed Note: Spares viz. safety valves, non-return valves, indicator lamps, stainelss steel dome, heating element, thermostat shall be measured and paid separately under respective items herein
Supply only heating element 1.5kW, ISI marked, of existing make
Supply only heating element 2kW, ISI marked, of existing make
Supply only thermostat, ISI marked, of existing make
Supply only indicator lamp Red/Green, ISI marked, of existing make
Supply only air release valve suitable for geysers, ISI marked, of existing make
M&L for removing / scrapping of old worn out paint from geysers 25 / 35litres capacity by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (white tint) over a coat of red oxide zinc chrome primer and writing MES number of geysers (tint as approved and sutable sized font) in body of geyser complete all as specified and as directed
S&F in repairs non-return valve, 15mm dia conforming to IS: 5312 (Part-1) 2004, swing type with matching flanges, nuts bolts, rubber washers, etc. for geysers complete all as specified and as directed
M&L for taking down split type AC 1.5/2TR capacity for required servicing, cleaning of cooling coil, air filters/plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solutions, etc., checking serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches, knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed Note: Spares / components replaced shall be measured and paid separately under respective items herein
M&L for taking down window type AC 1.5TR / 2TR capacity for required servicing, cleaning of cooling coil, air filters / plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solution, checking the serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed Note: Spares / components replaced shall be measured and paid separately under respective items herein
Supply only running capacitor 36 / 45MFD
Supply only starting capacitor 100-150MFD
Supply only starting relay 1022/1622/2000
Supply only thermostat switch 2059/2064/2054
Supply only lit lawn sheet 6mm thick and 1000mm wide
Supply only fan motor for split type AC 1.5/2T
Supply only plastic condenser fan blade for split type AC 1.5/2T
Supply only copper filter, double capillary, pencil type
Supply only thermocol sheet 40x20inch and 20mm thick
Supply only wiring kit for AC split type 1.5/2T
Supply only remote control for split AC 1.5/2T of existing make
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split AC capacity 1.5/2T
Supply only fan motor for cooling unit of split AC 1.5/2T
Suction and discharge valve set for split AC 1.5/2T
Supply, installing, testing and commissioning of compressors of AC units in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed for the following types and capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
Split type air conditioner of capacity 2Ton
Split type air conditioner of capacity 1.5Ton
Supply, installing and testing of fan motor / blower motors of AC units split type of capacity 1.5/2Tonin any location / position including disconnecting electrical mains, removing the clutter, grill, wires, vacuuming the fins, etc. taking out the fan / blower motor, cleaning, removing dust / dirt, etc., around and replacing motor and finally put the rest back together and commissioning including disposing of old unserviceable motor complete all as specified and as directed for the following types and capacities: Notes: (i) Fan / blower motors shall be from existing manufacturer / as approved by the GE (ii) Fan / blower motors shall bear a minimum guarantee of 5years and as given by manufacturers
Supply, installing and testing of condenser coils of AC units in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed for the following types and capacities: Notes: (i) Condenser coils shall be of existing manufacturer / as approved by the GE (ii) Condenser coil shall bear a minimum guarantee of 5years and as given by manufacturers
Window type air conditioner of capacity 1.5/2Ton
Split type air conditioner of capacity 1.5/2Ton
S&F copper pipe with all necessary brazing, welding, providing butt bolts and screws of required sizes, clamps, etc. including taking down old unserviceable copper pipes of any sizes / dia and disposing off complete all as specified and as directed for the following sizes:
Supply, fixing and testing of cooling coils of AC units in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable cooling coil complete all as specified and as directed for the following types and capacities: Notes: (i) Cooling coils shall be of existing manufacturer / as approved by the GE (ii) Cooling coil shall bear a minimum guarantee of 2 years and as given by manufacturers
Window type air conditioner of capacity 1.5/2Ton
Split type air conditioner of capacity 1.5/2Ton
M&L for charging refrigerant gas F-22/R-134A in window type / split type AC units of capacity 1.5/2Ton including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for collecting unserviceable voltage stabilizer of capacity 75kVA from Site-IV Kalpi, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get correct output and transporting back the same to MES store yard complete all as specified and as directed Notes: (i) Cartage shall include both loading and unloading, etc. (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured & paid separately under respective items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted in this item
Supply only printer circuit card of 75kVA voltage stablizer
Supply only servo controlled motor for dimmer stat
Supply only sproket set for servo controlled motor
M&L for collecting unserviceable voltage stabilizer of capacity 3 to 5kVA from Site-IV Kalpi, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get correct output and transporting back the same to MES store yard complete all as specified and as directed Notes: (i) Cartage shall include both loading and unloading, etc. (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured & paid separately under respective items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted in this item
Supply only voltmeter (Anlogue) 0 to 300V any type / shape single phase 50Hz AC supply
Supply only digital type voltmeter 0 to 300V any type / shape single phase 50Hz AC supply
Supply only printer circuit control card suitable for 3kVA
Supply only printer circuit control card suitable for 4 to 5kVA
Supply only input/output switch
Supply only push-on switch
Supply only indicator with bulbs
Supply only trigger transformer for 3 to 5kVA
Supply only relay for 3 to 5kVA voltage stablizer
Supply only time delay and high/low voltage cutoff circuit with relay suitable for 3 to 5kVA
M&L for taking out burnt winding of transformers of voltage stabilisers 3 to 5kVA capacity carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
Supply only capacitor 4MFD for desert cooler
Supply only PVC pipe 1/2 " bore with plastic elbow of existing length
S&F 6mm thick wooden ply of size 3’x6’, water proof, for fixing of desert coolers / window ACs, etc. complete all as specified and as directed
M&L for repairing of rusted/corroded body/leg/water tray of water coolers by replacing the same with existing size of MS CRCA sheet by welding/brazing, etc. complete all as specified and as directed
Disconnecting from mains and taking down for servicing water coolers upto 150litres capacity including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and making the water cooler to satisfactory working conditions all as specified and as directed Note: Spares / parts / componenets replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement shall be deemed to be included in these unit rates quoted
S&F condenser fan motor of capacity 1/10HP, 1/16 HP single phase AC 220V suitable for water coolers of capacity 80/150litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F condenser fan motor of capacity 1/32 HP single phase AC 220V suitable for water coolers of capacity 40litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F cooler fan motor of capacity 1/10 HP single phase AC 220V suitable for water coolers of capacity 80/150litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F water lifting pump, heavy duty, single phase 240V single phase AC suitable for water coolers of capacity 150litres including disconnecting the electric mains and taking out and disposing off the unserviceable pump and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F company made new sealed compressor units for water coolers including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed for the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
80/150litres capacity
40litres capacity
M&L for charging refrigerant gas F-22 in water coolers of capacity 150/80/40litres including required staging / taking down of compressor units, cooling coils, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for removing / scrapping of old worn out paint from water coolers by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of coolers (tint as approved and sutable sized font) in body of cooler complete all as specified and as directed for the following sizes:
150litres capacity
40litres capacity
S&F in repairs water cooler tap, self closing, 15mm dia complete all as specified and as directed
S&F in repairs thermostat switch of existing size for water cooler of any capacity complete all as specified and as directed
S&F in repairs starting relay of existing size for water coolers of any capacity complete all as specified and as directed
S&F company made new sealed compressor units for refrigerators, 165/180litres capacity including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
M/S Sonu Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .