Loading…
Loading…
Tender ID
Tender Value
₹17.6 L
EMD Value
₹18,000
Closing Date
2 Mar 2026, 6:00 pmClosed
Executive Engineer, Public Health Mechanical Division Rajkot
Installation, Testing & Commissioning of Polder Pump set with pontoon with Co-Ordinated Mechanical Accessories, Electrical Equipments etc. with security complete at Bhadar-1 Dam Floating Head Works with four (04) months Operation & Maintenanace complete under Jetpur Group RWSS based on Bhadar-1 dam in Ta.-Jetpur, Distt.-Rajkot
279351
47/2025-26
Open
Pumps/Motors
Works
Rajkot
8 documents required · 7 mandatory · 1 optional
₹900
Yes
Executive Engineer, Public Health Works Division, Jetpur
₹18,000
Yes
21 Feb 2026
21 Feb 2026
21 Feb 2026
2 Mar 2026
21 Feb 2026
Schedule-B-1 (Mechanical work)
Polder pump
1 Installation, Testing & Commissioning of departmentally available Polder pump set of capacity - 240 LPS X 30 Mtr Head & 1 Set 0.00 69758.80
prime mover of 160HP (1W)
Erection & Installation of metallic floating Jetty / Pontoon with required capacity chain pulley block and gantry girder
structure including supply of required materials like MS angles, channels, floats, GI / MS pipes, hardware, MS / Aluminum
chequered plate with MS / GI safety railings etc. and fabrication work whichever required at the time of work at site and
then complete erection into the dam upstream.
MS Specials
Supply at Site, Storage, Erection, Installation, Testing & commissioning of MS specials of following size with Flanges,
ecentic nozzles, Bolts, Nuts, reducer, expander etc. Complete as per relavant IS.
suitable for 350mmØ Delivery line
Transportation of MS Pipe and 350mm dia. SS Flexible Hose Pipe both from machhu 2 dam to Bhadar-1 Dam
including loading, transporatation,unloading,proper stacking etc including labour, hydra crane etc complete.
5 ITC of departmentally supplied 350 mm dia MS Pipe 1400 Kgs 0.00 11.36
Erection of corrugated hoses as per relevent IS with SS304 double wire bracing of 3 Mts. Length of following diameter
6 with flange of suitable size and thickness on one end. -- SS 304 compelete double wire brading end fixed other end swivel 10.00 Job 0.00 23500.00
MS ASA 150 # 10 mm thick flange size 350 NB x 3 mts
Transportation of Floater suitable for 350mm dia. Flexible Hose Pipe from machhu 2 dam to Bhadar-1 Dam including
loading, transporatation,unloading,proper stacking etc including labour, hydra crane etc complete
Erection of PE Hexene Grade with metallocene grade polyethylene with hexene as a comonomer with UV stabilized PE
8 density 0.939 g/cm3, MFI 3.2 to 4.0 g/10 min pipe float for 350 mm diameter hose pipe with nut bolt and washers etc. 14.00 Nos 0.00 2182.90
Installation, testing & commissioning of departmentally available 350 mm dia flange ends Expansion Bellow of PN1.0
for Delivery pipe
Installation, Testing & commissioning of departmentally available 350 mmØ Both End Flanged Dual Plate Check Valve
on Header Side as per relavant Std. with PN 1.0 Rating to be installed on delivery pipe.
Installation, Testing and Commissioning of departmentally available CI D/F 350 mm Ø Butterfly Valves of PN1.0 (gear
operated) for Delivery pipe.
Pressure Gauge with Accessories:
Supply at site, Storage, Erecting Istallation Testing & commissioning of Bourdon type pressure gauge, ± 1% Accuracy,
direct bottom 1/2" ,NPT(M) process connection, IP 67, Glycerine filled SS304, Case with Bayonet type Bezel, SS 316 L
bourden tube, SS 316 Movement material Aluminium Dial with black graduation on white background, Micro Zero
adjustable pointer, neoprene gasket, Blow out disk,shatter proof glass, SS tag plate etc as per IS 3624 (150 MM Dia) (of
range 0 -10 kg/cm2 with IS 3624)
Providing & casting in situ reinforced cement concrete in grade M 20 (Ratio 1:2:4) using quartzite trap metal of size 6 mm
to 20 mm for RCC work, including scaffolding centering, form work, consolidating, curing etc. inclusive providing and
binding necessary size TMT steel bars of Fe 415 grade with water proofing compound as per directives for pipe support /
thrust blocks.
Description of Item Qty Unit Supply Labour Amount (Rs.)
MS fabricated structure cabin
Supply and installation of MS fabricated structure cabin @ site of work using 65 mm, 50 mm & 25 mm square pipes with
cabin minimum size 6.0 mtr X 4.0 mtr X 3 mtr or required size as per site situation including providing & fitting of (1)
backalite sheet 3.5 mm thick in sides, (2) 20 guage MS sheet outer side for side walls, (3) backalite sheet 3.5 mm thick
sheet for roof side, (4) 24 guage GI sheet out side with 15 mm plywood sandwitch fitting & flooring with 19 mm water
proof plywood sheet and (5) shock proof rubber mating. Job includes oil painting two coats, door locking handle
arrangement, providing proper air entilation and fuse box. The meter & fuse box should be fitted on timber hold fast for
holding screw or nut bolts by semi skilled labour as per detailed technical specifications, drawings and instructions of the
Engineer-in-charge.
S.I.T.C. of Approved make four pole MCCB having breaking capacity ICU of 50 KA 415 V having normal current rating
400 A with variable Thermal and magnetic release suitable to work on AC Supply 50 C/s with all internal
connection,spreader,tinned copper and complete with suitable size enclosure erected in 16 GMS Housing on angle frame or
as per site requirement. ICS=100% of ICU only(Cat.-III)
MCC Panel: 125 KW
Installation, Testing & commissioning of departmentally available Soft starter type MCC panel totally enclosed dust
16 &bermin proof,indoor type of Minimum incommer of suitable KW & One outgoing feeder of 125 kw 1.0 Set 0.00 7424.00
The scope includes dismantalling of control panel at machhu-2 dam hws and seperating the control panel from its common
bus bar and also fixing the sheet if required in one side.
Maintenance free Chemical Earthing
SITC of UL Listed Maintenance Free Earting System made of copper bonded rod of 10 feet (3 mt approx.) length, 17.2mm
17 dia. (Minimum copper bonding shall be 0.25mm, suitable for 25 kA fault current) along with Rod-to-conductor connectors, 2 Nos 5356.00 0.00
95% pure Crabon-Based Earth enhancement material of 30 kg, pit cover as required and as per specification.
Providing and erecting required size HOT dip Galvinized Strip of size 50 mm width X 12 mm thickness for earthing of
18 HT/OCB/ACB/Transformer/LT Panel Board/Motors etc. using copper clamp for the purpose of connecting panel body 50 Kgs 60.00 17.00
earth to earth pit etc complete as per site requirement.
Providing and erecting copper busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet,dust & vermin proof
having hinged door with rubber gasket and necessary busbar supports with Copper busbar having current density not more
than 1.6 Amp. / sq.mm (Rated current /crosssectionarea)duly wrapped with colour insulation tape for phase sequence, three
phase & neutral each Suitable for following current capacity with necessary painting mounted on wall or pedestal frame of
required size with necessary connections.
Suitable for 300 Amp. capacity
Installation, testing & commissioning of 1.1 kV (UE) grade, XLPE insulated, stranded Aluminium conductor, galvanised
steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with
necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site
20 requirement) conforming to IS:7098 (Part-2) & IEC:60502 (Part-2) of 200 Mtr 0.00 19.00
Size:1X3X240 Sqmm: ( Panel to Junction box)( Two Runs of 600m length for each pump) (400A MCCB to MCC
panel and MCC Panel to Junction Box)
21 Supplying and erecting 12 mm thick rubber mat as per IS 15652/IEC 61111 3 Sqm 3051.00 0.00
Description of Item Qty Unit Supply Labour Amount (Rs.)
Dismantling of pump motorset,cable, panel,pipe &other accessories etc.component & loading in vehicle transportation to
22 Departmental store and unloading at store and proper stacking including hydro,labour etc complete 1 Job 0.00 40770.03
(AS per attached Annexure-A)
Supply of Manpower for the operation, repair and maintenance and security of the machinery and accessories and for the
23 movement of the pumpset and accessories if necessary according to the level of the water in dam as per instructions of the 4 Months 82551.00 0.00
Engineer-in-charge. (considering 5 manpower - 3 Operator + 2 Helper)
Total Rs. (Mechanical Work)
Schedule-B-2 (Civil work)
Description of Item Qty Unit Rate Amount (Rs.)
355.6mm Dia. MS Pipe (5.6mm Thickness) Removing of existing pipeline incl. removal of specials, valves, jointing material
1 including carting and stacking of removed material from site of work to the departement store as direcated excl.excavation and 500 Mtr 93
refilling.
355.6mm Dia. MS Pipe (5.6mm Thickness) Lowering, laying, Jointing & welding in position to correct line & level M.S. Pipe with
2 outer gunniting & inside lining/Epoxy painting on pedestal or chairs upon prepared formation or prepared bedding in trenches 500 Mtr 320
the rates include conveyance from store to site of work loading, unloading, joint plastering, hydrotesting etc.complete.
3 Above 300 mm. dia. M. S. Specials Flanged ends 1000 Kg 98
350MM Sluice valves Lowering, laying and jointing in position following C.I./D/F Reflux valves, Butterfly valves, Sluice valves
4.1 and Air valves including cost of all labour, Jointing material. including nut bolts and giving satisfactory hydraulic testing, etc 2 Nos 1742
Air Valve double ball 80mm Lowering, laying and jointing in position following C.I./D/F Reflux valves, Butterfly valves, Sluice
4.2 valves and Air valves including cost of all labour, Jointing material. including nut bolts and giving satisfactory hydraulic 3 Nos 411
testing, etc complete.
For 30-No Block Size (0.60*0.80*0.80) Providing and casting in situ C.C. in grade M-15 (approx. corresp. to prop. 1:2:4)
(proportions as per mix design or as per Table 9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal
5 of size 6 mm to 20 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing comp. 9.73 Cum 4906
up to 6 meter depth or height (excluding cost of reinforcement and neat finishing) with centering and shuttering /deshuttering
etc. comp. for structure for other than water retaining.Footing for column or foundation (with form work)
6 Loding , Unloading and Conveyance 355.6 mm Dia DI Pipe from Machhu-2 Dam to Bhadar-1 Dam (135K.M.) 12 Trip 9241.75
7.1 Hiring of Hydra/Crane with Driver (8 working hours in Day) 12 tone 5 Day 3334.49
7.2 Hiring of tractor with troley considering 8 hrs. as working day including driver 5 Day 2104.09
Total Rs. (Civil Work)
Total Rs. (Mechnaical Work + Civil Work)
Estimated cost in words Rupees - :- Seventy lakh sixty thousand six hundred eighty nine only
Amount of my / our tender works out as under :
Estiamted Amount ( For Above) Rs.1760689.00 Estiamted Amount (for Below) Rs.1760689.00
Put to tender Rs. _______________________________ Put to tender Rs. ______________________
Add _____ Rs. ____________________________________ Deduct ___ below Rs. _______________
Net Total Rs. _______________________________________ Net Total Rs. ___________________________
In Words Rs. ______________________________ In Words Rs. __________________________
Executive Engineer
P.H.Mechanical Division Rajkot
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.0 General Terms Condition Bhadar-1 Dam floating.pdf
2.0 Technical Specifications Bhadar-1 Dam floating.pdf
3.0 Volume- III Specifications O and M. final.pdf
4.0 Technical Specifications Bhadar-1 Dam floating.doc.pdf
5.0 Price Bid.pdf
6.0 Annexure A.pdf
7.0 Price Variation Paripatra 2023.pdf
8.0 BANK LIST and GR NEW.pdf
9.0 GST GR.pdf
10.0 Bank Gaurantee DMO 2876 01 May 2025 273.pdf
11.0 SD EMD GR.pdf
12.0 SD GR.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .