Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance C 199 BULANDSHAHR ROAD INDUSTRAIL AREA GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance NEAR HAPUR ROAD FLYOVER CHW FORGE PRIVATE LIMITED MALIWARA MALIWARA GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 2017 PHASE III GIDC IND ESTATE AHMEDABAD AHMEDABAD AHMEDABAD GUJARAT 382445 | AHMADABAD | GUJARAT | 382445 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
12 Jun 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S Sriram
Technip Energies India Ltd No. 19, Velachery Main Road, Guindy, Chennai - 600032
Manufacturing, Procurement of Materials, Testing at Manufacturers works, Inspection by TPIA, Packing, Supply of SPECTACLE BLINDS
2024_REFHQ_177434_1
TP/077154C001/000/1393-301/347
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
120 days
IOCL, Gujarat Refinery
Please refer Tender documents.
5 documents required · 5 mandatory
Exempted
13 Jun 2024
15 May 2024
13 Jun 2024
15 May 2024
12 Jun 2024
30 May 2024
15 May 2024 - 24 May 2024
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.11 Cl.2, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, IBR
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.11 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,
0.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -,
2 INSpectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -,
Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -,
Paddle Blind & Spacer, ASME B16.48, ASTM A387 Gr.5 Cl.2, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -,
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR
3 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A387 Gr.9 Cl.1, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR
1.5 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, IBR
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR
1.5 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, Hydrogen Service
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements
0.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -,
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -,
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -,
Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, IBR,
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -,
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -,
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, IBR, Refer to Axens specification IN-042.0 for additional requirements
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, IBR, Refer to Axens specification IN-042.0 for additional requirements
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,
1.5 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, -,
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,
.5 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,
14 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm
2 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RTJ Flanges, as per ASME B16.5, -, 2500 Lbs, -, -, -, -,
10 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm
12 IN Paddle Blind & Spacer, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service
Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm,
4 IN x 2 IN Spectacle Blind Fig.8 for Oversized Flanges, Prj Std, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm,Spectacle Blind Fig.8 Dimensions As per Annexure-2
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
1.5 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, -,
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 6 mm
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, C.A. = 6 mm
.75 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service,Refer to Axens specification IN-043.0 & IN-042.0 for additional requirements
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 + Sour Service + HIC Test, Between RF Flanges, as per ASME B16.5, -, 600 Lbs, -, -, -, C.A. = 6 mm
8 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements
4 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Epoxy Coated, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Refer to Axens specification IN-042.0 for additional requirements
1 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A516N Gr.70 Galv. as per ASTM A153, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, -,
6 IN Spectacle Blind Fig.8, ASME B16.48, ASTM A240 Gr.321, Between RF Flanges, as per ASME B16.5, -, 300 Lbs, -, -, -, Hydrogen Service
16 IN Paddle Blind & Spacer, Prj Std, ASTM A240 Gr.321, Between RTJ Flanges, as per Project Std, -, 2500 Lbs, -, -, -, Hydrogen Service Paddle Blind & Spacer Dimensions shall be as per Annexure-3
14 IN Paddle Blind & Spacer, Prj Std, ASTM A240 Gr.321, Between RTJ Flanges, as per Project Std, -, 2500 Lbs, -, -, -, Hydrogen Service Paddle Blind & Spacer Dimensions shall be as per Annexure-3
8 IN x 6 IN Spectacle Blind Fig.8 for Oversized Flanges, Prj Std, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm,Spectacle Blind Fig.8 Dimensions As per Annexure-2
10 IN x 8 IN Paddle Blind & Spacer for Oversized Flanges, Prj Std, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm,Paddle Blind & Spacer Dimensions As per Annexure-2
14 IN x 12 IN Paddle Blind & Spacer for Oversized Flanges, Prj Std, ASTM A516N Gr.70 + Sour Service, Between RF Flanges, as per ASME B16.5, -, 150 Lbs, -, -, -, C.A. = 4.5 mm,Paddle Blind & Spacer Dimensions As per Annexure-2
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .