Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
7 Aug 2023, 6:00 pmClosed
GE Clement Town
GE Clement Town MEs Dehradun
PROVISION OF HARDSTANDING WITH INTERLOCKING TILES IN OPEN GYM AREA NEAR BLDG NO. P-36 AT PCDA (AF) AND SPECIAL REPAIR TO PUMP HOUSE IN 501 OFFICER MESS OF NHO AND BLDG NO. P-05 AND P-06 (OLD RECORD) AT PCDA (AF) UNDER GE CLEMENT TOWN, DEHRADUN
2023_MES_605778_1
GE /CLT/ of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class D Cat a(i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹83,000
Yes
19 Dec 2023
26 Jun 2023
14 Aug 2023
27 Jun 2023
7 Aug 2023
18 Jul 2023
Amount
Excavation in trenches n.exc. 1.5m wide and n.exc. 1.5m depth for foundation and getting out in any type of soil complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out any type of soil complete all as specified and directed.
Surface dressing not exceeding 15 cm deep and getting out any type of soil complete all as specified and directed.
M&L for providing cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in mass concrete ,sub base of floor complete all as specified and directed
M&L for cement concrete type D2 (1:4:8) (40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L brick work with sub class "B" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Returning, filling in incl spreading levelling watering and well ramming in layers n.exc 25 cm as in soft/ loose soil complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where at a level n exc 1.5 m above the starting point in soils complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement concrete type B2 (1:2:4) (using 20mm graded stone aggregate) as in surface channels and drains finished fair and even complete all as specified and directed.
M&L for preparing new steel and iron surfaces of any description over 10 CM width or girth and applying two coats of synthetic enamel paint of any tint over one coat of red oxide primer complete all as specified and directed.
S&F Reinforced Concrete Pipe 300mm bore of pipe class NP2 laid and jointed complete with collars complete all as specified and directed.
M&L Concrete bed to drain pipes bore of pipe 300 mm including packing under and completely surrounding pipes with concrete after they are laid and tested,in Cement Concrte (1:4:8) type D-2 complete all as specified and directed.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed.
Dismantling of boarding of any type/size as in CB/wardrobes or fixed in any position in hardware (if any) etc complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size exc 1.5 Sqm and n.exc 4 Sqm complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed.
S&F mild steel framed work as in grills, gratings etc with ends of bars shouldered and riveted or forged into spikes, framed guard bars, barred iron doors etc, conforming to Fe-290, Gde-E-165 complete all as specified and directed.
S&F Welded steel wire fabric weight n.exc 4 kg/sqm fixed to wood or steel members complete all as specified and directed.
S&F joist channel, angle or tee section by welding fixed independently without connecting plates etc. in fening post & gates etc complete all as specified and directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in sub base/ levelling course of floor complete all as specified and directed.
M&L 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L for Non skid Heavy duty Parking coloured tiles 8-10mm thick (square/rectangular) grade-4, area of each tile exc 0.06 Sqm but not exc 0.11 Sqm over and including 15mm thick screed bed in Cement mortar (1:6) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for joint free Non-skid ceramic coloured tiles 7-8mm thick (square/rectangular), area of each tile exc 0.11 Sqm but nexc 0.18 sqm, over and including 15mm thick screed bed in CM (1:6) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for Glazed ceramic coloured joint free tiles 450x300X7mm in vertical surfaces over and including 10mm thick rendering in Cement mortar (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for Machine cut mirror polished Kota stone slab 18-20mm thick as in floor/ treads of steps (single piece) laid over and including 20mm thick screed in CM (1:6), set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing complete all as specified and directed.
M&L for Machine cut mirror polished Kota stone slab 18-20 mm thick (single piece) as in risers to steps, skiting/dado, pillars, window cills and the like, laid over and including 10mm thick rendering in cement mortar (1:4), set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified and directed.
M&L for rubber moulded coloured cement concrete chequered tiles polished of size 30cm x 30cm x 25mm thick jointed in neat cement slurry and pointed in white or coloured cement and pigment to match the surface of tile as in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for coloured Machine pressed precast glossy finish polished concrete interlocking paver block as in road berm, path and hardstanding any shape and size confirming to IS 15658-2006 of 80mm thickness, M-35 grade with pigments over and including 50mm thick sand cushioning complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.50m clear span, cills, steps, seismic and other similar bands, plinth courses, lacing courses, string courses, parapets and railings upto 60cm in height, coping, kneelers, apex stones, bed plates, hold fast blocks, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
S&F Factory made 100% Solid WPC Brown door Frame (75mm x 50mm Single Rebate) made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification drawing as directed by the Engineer-in-Charge. The door frame should be Waterproof, Termite Proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed.
S&F 24mm thick Moulded WPC Brown Factory made 100% Solid door (Conforming as Per IS:4020) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with Wood Grain Texture and back side plain with density not less than 600 kg/cum. Manufactured by an ISO: 9001-2015 certified company. The door should be Waterproof, Termite Proof, Fire Retardent and having screw holding capacity complete all as specified and directed.
S&F three track Pre coated Steel Sliding Window System fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality, galvanized as per IS 277 with Zinc of 120 grams/ Sq. Mtr.) with total coated thickness of 0.58 mm or Powder Coated with pure Polyester Powder up to 50-60 microns thick. Windows Section for three track external frame should be of 44 x 107mm , Section for window glass shutter should be of 36 x 50 mm, if required Section for shutter horizontal mullion should be 22mm x 60mm, The windows should be paneled with 5mm thick Plain Float glass Gaskets are to be made with Ethyl Propylene Diamine Manomer (EPDM). Corner brackets for internal and external frame made of Polypropylene. Touch lock to be provided for window shuttes Sections are to be cut to length, joined and assembled by means of corner brackets. The above Frame should be fixed to brick/ concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames.Windows shall be provided with fixed Stainless steel 32gauge wire mesh/gauze of 304grade with 144 holes per square inch for mosquito proofing with the help of nut, bolt and flat iron of 20x3mm size on top and Grill made of 12mm MS Square bars welded to 25x4mm angle iron . Distance between bars should not be more than 100mm centre to centre. Total Grill and wire mess unit shall be powder coated.Assembling and installation of windows and ventilators shall be all as per details shown/mentioned on drawings and as per manufacturer‟s instructions complete all as specified and directed.
S&F in repair 18mm thick WPC board one side prelaminated and other side plain white colour as in cup boad shutters and frames, kitchen cabinet front shutter, partion, shelf & drawer, fixed with screws, solvent cement/ adhesive complete all as specified and directed.
S&F of 100mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S&F 150mm long, Stainless Steel barrel tower bolts complete all as specified and directed.
S&F 150mm size Stainless Steel handles, all as directed complete all as specified and directed.
S&F 150mm Stainless Steel Hasp and Staple, including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F in repair Hydrulic Self Closing hinges 35mm of crank( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L 15mm thick rendering cement mortar (1:4) mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. (WPC shall be paid seperately)
M&L 5mm thick rendering in ceiling of cement mortar (1:3) on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for three coats of white wash to newly plastered surfaces of ceiling including preparation of surfaces, complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of 2mm thick wall putty to newly plastered surface including preparation of surfaces complete all as specified and directed.
M&L two coats of weather coat paint (Ist Quality) over a coat of primer to newly plastered surfaces of wall including preparation surfaces complete all as specified and directed.
M&L for preparation of surface old plastered or unplastered by washing down and scrapping old distempered surface and applying two coats of oil bound distemper over 2 mm thick wall putty on wall surfaces complete all as specified and as directed.
M&L for complete removal of existing treatment on walls and applying two coats of weather coat (Ist Quality Asian Paint APEX, Berger Weater Coat or equivalent In Nerolac) over a coat of primer complete all as specified and directed.
M&L for Preparation old decorated surfaces and applying one coat of white wash on ceilings complete all as specified and directed.
M&L for preparing old steel and iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F 15mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete all as specified and directed.
S&F 20mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling for 15mm bore GI tubing complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling for 20mm bore GI tubing complete all as specified and directed.
Cutting chases, pinning in, making good to facing where required and pointing in Cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water pipe etc and making good, cutting not exc 10cm width or girth complete all as specified and directed.
S&F in repair 20mm dia gun metal gate valve with iron wheel haeded screwed both ends to iron pipe and fixed complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) floor trap with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed.
S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified and directed.
S&F in repair PVC waste pipe 32mm dia complete all as specified and directed.
S&F in repair 20mm dia brass CP tubular towel rail D type 600mm long complete all as specified and directed.
S&F in repair brass CP bib tap 15mm bore screwed for iron pipe complete with wall flange complete all as specified and directed.
S&F in repair 15mm dia brass chromium plated pillar tap long body with fly nut capstan head screwed for 15mm bore dia of pipe complete all as specified and directed.
S&F in repair CP angular stop cock 15mm dia single way and fixed complete all as specified and directed.
S&F in repair Sheet glass shelf assembly/Glass Corner assembly set of three consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repair Vitreous china wash hand basin including brackets, white size 550 x 400 mm incl cutting cutting for and pinning in ends of brackets. Including Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed.
S&F in repair Vitreous china squatting pan ‘Orissa pattern’ size 580x440mm white with integral foot rest including connection to trap, and flushing pipe, anti-syphonage pipe, etc and including lime concrete bedding complete all as specified and directed.
S&F in repair 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed.
S&F in repairs PVC water storage tank double layer cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 500 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed.
S&F in repair 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
Removal of existing roof treatment i.e. APP Membrane, brick tiling including concrete padding and benching and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material without damaging existing serviceable structure complete to receive new roof treatment including rubbish off the premises upto a distance exc 250 mtr but n.exc 500 mtr complete all as specified and directed. (Note : The work is required to be carried out at non-accessible roof . The contractor shall make arrangement of scoffolding , safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items.)
M&L for rendering 10mm thick screed bedding in CM (1:3) mixed with acrylic bonding compound SBR Latex liquid polymer finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : Proportion of mix and method of mixing of approved liquid water proofer admixture should be applied as per manufacturer's printed instructions). (Note : The work is required to be carried out at non-accessible roof for double storey. The contractor shall make arrangement of scoffolding , safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items.)
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer's instructions with following course of description below :- (i) Applying a priming one coat of bituminious primer evenly @ 0.30 Kg/Sqm till the surface is properly impregnated. (ii) Providing APP based 5 layer polymeric membrane minimum weighting 3.60 Kg/Sqm and minmum 3mm thick reinforced with polyester non-woven fabric matt (weight not less than 150 gms/Sqm) centre core laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75mm and end overlap of 100mm. All overlap joints shall br sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer. (iii) Apply two coat of bituminous aluminium pain @ 0.20 Kg/Sqm over APP Membrance. (Note: the work in respect of water proofing treatment shall be carried out only by authorized/approved applicator of the manufacturer/firms of app membrane. The contractor shall submitted 10 year company back warranty before claiming payments complete all as specified and directed. (Note : The work is required to be carried out at non-accessible roof for double storey. The contractor shall make arrangement of scoffolding , safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these iems.)
REPAIR TO SUMP :- Surface preparation : RCC surface must be clean , even and sound concrete, remove all oil, dirt, laitance, protrusions (by light grinding) and other contaminants manually to attain a fairly smooth surface complete all as specified and directed.
Crack treatment : Cutting and opening cracks to a depth of 10mmx10mm in V shape by mechanical means, cleaning all dirt and loose particles using Nitobond SBR/ SBR latex of Fosroc/ Sika/ CICO having specific gravity ranging from 1.015 to 1.040 @27deg celsius mixed in the ratio of 1 (polymer) : 3 (cement) maintaining W/C ratio 0.35 to achieve thixotropic consistency.
Injection Grouting : Providing chemical injection treatment in the form of pressure grouting to the cold joint by injecting cement slurry (Preferred cement should have min blain value 300-500 sqmtr per kg) mixed with required consistency through the pre fixed PVC nozzle in the 18 mm dia holes fixing of PVC nozzle with Renderoc Plug and final cutting the projected nozzle and sealing off the PVC nozzle after the injection operation is over with Rendroc plug non shrink rapid setting mortar compound , finishing curing etc as per manufacturer specifications and as directed complete all as specified and directed.
Coving : Providing and applying cement mortar 1:4 admixed with modified acrylic emulsion specifically designed as a bonding aid , curing agent and gauging liquid for cementiotious system of FOSROC/SIKA/CICO at the junction of slab and vertical offsets complete all as specified and directed
Water proof coating : Providing and applying two coats of high performance elasto meric acrylic polymer modified cementitious coating like brushbond RFXof FOSROC / Topseal 109 HI of Sika/Repecrete RTU of CICO having a mixed density of 1.6 kg/cc applied by authorised applicators. Minimum recommended coverage is 0.5 m2/per kg/ 2 coats to achieve a DFT 1 mm water proof coating shall confirm to ASTMC-836, ASTM D 4541 & ASTM D 4060 brush bond RFX coating shall exhibit below properties: (i) Abrasion resistance ASTM D4060: 0.85 (ii) Tensile strength as per ASTM D412: 1N/mm2 (iii) Adhesion to concrete is greater than 1N/mm2 (iv) static crack accomodation ASTM C836: min 1mm system include supply and application all complete as per Fosroc methodolgy complete all as specified and directed.
Food grade coating (internal) : Providing mixing and applying Nitocote EP405 by FOSROC/ Sika grade-67 of Sika/ Cicoguard-WS of CICO applied by authorised applicator, Nitocoat EP405 is 100% (volume of solids) solvent free epoxy resin system designed for potable water retaining structures. Min recommended rate of application is 0.25-0.30 ltr/sqm to achieve a total DFT of 200 microns. Product shall be CFTRI approved and cured film shall comply with the requirment of IS:9833-1981 system includes surface preparation and application as per fosroc methodology complete all as specified and directed.
Protective coating (External) : Providing and applying crack bridging and anti carbonation coating for concrete base even at temprature below zero degree Celcius. Minimum recommended rate of application is 1.5 m2 /ltr to achieve a total DFT 200-300 micron on external side of sump complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L RCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, canopies, deck slabs or in Chajja/facia projection and the like complete all as specified and directed.
M&L mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed.
M&L for Udaipur green marble (in single piece) pre polished 18-20mm thick as in cill of windows/ ventilators laid over and including 20mm thick screed in CM 1:6, set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing, polishing, bull nosing at ends complete all as specified and directed.
S&F Pre coated Steel fixed type / partly fixed partly openable Window/ Ventilator fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality, galvanized as per IS 277 with Zinc of 120 grams/ Sq. Mtr.) with total coated thickness of 0.58 mm or Powder Coated with pure Polyester Powder up to 50-60 microns thick. The windows should be paneled with 5mm thick frosted glass Gaskets are to be made with Ethyl Propylene Diamine Manomer (EPDM). Corner brackets for internal and external frame made of Polypropylene. The above Frame should be fixed to brick/ concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames. Windows shall be provided with Grill made of 12mm MS Square bars welded to 25x4mm angle iron . Distance between bars should not be more than 100mm centre to centre. Total Grill shall be powder coated.Assembling and installation of windows and ventilators shall be all as per details shown/mentioned on drawings and as per manufacturer‟s instructions complete all as specified and directed.
M&L for preparation of surface plastered or unplastered by washing down and scrapping old distempered surface and applying one coat of oil bound distemper on wall surfaces complete all as specified and directed.
M&L for 25 mm thick PCC(1:2:4) type B-0 (using 12.5 mm graded aggregate) pedding mixed with liquid water proofing compound (as per manufacturer direction and paid separately) over and incl one coat of cement slurry admixed with acrylic bonding compound SBR latex liquid polymer as per manufacturer direction abd finishing the surface even and smooth without using extra cement complete all as specified and directed.
S&F Factory made 100% Solid WPC Brown door Frame (100mm x 63mm Single Rebate) made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification drawing as directed by the Engineer-in-Charge. The door frame should be Waterproof, Termite Proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed.
S&F 30mm thick Moulded WPC Brown Factory made 100% Solid door (Conforming as Per IS:4020) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with Wood Grain Texture and back side plain with density not less than 600 kg/cum. Manufactured by an ISO: 9001-2015 certified company. The door should be Waterproof, Termite Proof, Fire Retardent and having screw holding capacity complete all as specified and directed.
S&F of 250mm long (Length of bolt) Stainless Steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, and fixing bolts and sliding bolt complete all as specified and directed.
Dismantling and taking down U/S copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified and directed.
Material and labour for point wiring with 1.5 sq mm PVC insulated, unsheathed 1.5 Sqmm multi stranded copper conductor (FRLSH) core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia concealled conduit and cutting chases of suitable girth where required on brick/concrete conduit accessories with provision of hard glossy surface sheet top cover (Hylem sheet) plate with 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable ( FRLSH) as earth wire connected with main common earth dolly complete all as specified and directed for light/fan/bell point.
One 3pin/5pin 5/6 Amps socket out let on same board controlled by one, one-way Piano type switch complete all specified and directed.
One 3pin/5pin 5/6 Amps socket out let on independent board controlled by one, one-way Piano type switch complete all specified and directed .
All as per item No 101 above but with 2.5 Sqmm PVC insulated cable( FRLSH) and same size of earth wire for 15 Amps power point.
Supply and fixing switch piano flush type single pole, one-way 5/6 Amps, 240 Volts AC complete all as specified and directed.
Supply and fixing switch piano flush single pole, one-way 16 Amp, 240 Volts AC complete all as specified and directed.
Supply and fixing socket out let 5 in 6 Amps flush type all as specified.
Supply and fixing socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC all as specified.
Supply and fix ceiling rose surface bakelite 65x25mm dia having three terminals complete all as specified and directed.
Supply and fixing batton/angle holder insulated body with back plate, suitable for batten fittings complete all as specified and directed.
Supply and fixing LED lights fitting 1X20 watt , 220V, AC decorative box type with driver, holder including LED tube rod 20 watt, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar all as specified and directed .Make- legrand / ABB/ Schneider
Supply and fixing MCB SPN 40 Amp 240 V AC 10 KA repturing capacity all as specified.
Supply and fixing MCB 6 to 32 Amp 'B' series 10 KA repturing capacity complete all as specified.
Supply and fixing of step socket type fan regulator 450W/250 V, 1 module complete all as specified and directed.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLS ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall as per existing along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLS ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and directed.
Fixing only LED type Security light fitting 20watt made out of pressure dia aluminium housing with heat resistant toughened glass and IP-66 protection complete all as specified and directed.
Supply, laid in trenches or fixed on wall pipe galvanized light grade with all fittings of size 40mm dia complete all as specified and directed.
Disconnecting and dismantling of service cable from wall and refixing after plastering work complete all as specified and directed.
Disconnecting and dismantling of unserviceable off size GI pipe from wall floor complete all as specified and directed.
Taking down ceiling fan from existing building again refixing the same ceiling fan connecting up including provision of cable flexible 3 core of suitable size wire from ceiling rose to connect fan complete all as specified and directed.
S& F wall mounted LED batten Box type fitting Blue colour end caps pre-wired LED fitting all as per cat part No DMLN 1 LT 8-16 with & including LED T8 tubular lamp of MAKE Crompton or equivalent make in philips / Havells / C&S.
M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below NGL and top edge of the plate not less than 1.5 Mtr deep below NGL, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in , removal of surplus soil to a distance in n.exc. 50 mtr incl GI wire 4 mm as earthing lead with nut bolts etc to earth plate one end connected to continuous earth wire incl GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed.
M&L sand cushioning 8 cm below and 15cm above the under ground cable for protection of cable with approved sand complete all as specified and directed.
Supply and laying fly ash bricks in layers prependicular to the axis of under ground cable for protection of cable complete all as specified and directed.
Supply and laying PVC insulated armoured heavy duty elect cable with STRANDED aluminium conductor 1100 V grade, cross sec area 16 sqmm 4 core and connected with aluminium lugs and properly crimped in trenches/ duct/ fix on pole complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
ANKIT KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .