Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹22.9 L+₹14,579.09 (0.64%)Rejected-Finance 33 A DURGA NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹22.9 L+₹21,391.94 (0.94%)Rejected-Finance 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹24.6 L+₹1.9 L (8.34%)Rejected-Finance | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹25.5 L+₹2.7 L (12.0%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Mar 2023, 6:00 pmClosed
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NOGE(N)AMB-76/2022-23 SPECIAL REPAIR TO BUILDING NO. P-306 AND P-307 OF KHARGA OFFICER MESS, PROVN OF TILING IN OR MD ACCN BLOCK NO. 476/7 TO 12 AND 488/2, 4 TO 8 IN BANA SINGH LINE IN SECTOR A AND PROVN OF URINAL BLOCK FOR STAFF
2023_MES_581544_1
GE(N)Amb-76/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) AMBALA CANTT
As per tender document
9 documents required · 9 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹90,000
Yes
13 May 2023
17 Feb 2023
27 Mar 2023
17 Feb 2023
25 Mar 2023
11 Mar 2023
17 Feb 2023 - 11 Mar 2023
Amount
Schedule 'A' Part-I (B/R itmes) Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engineer-in-Charge.
M & L providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of stone slab and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar including cement mortar bedding complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab flooring 18 to 22 mm thick of size not less than 550mm x 550mm in floor, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab flooring 18 to 22 mm thick in treads of step/stair etc, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge. Note :- The size of the kota stone in treads of stairs and steps shall be in one piece.
M & L machine cut kota stone slab skirting 18 to 22 mm thick cut from size not less than 550mm x 550mm for skirting , size for riser of steps/stairs in one piece, dados etc, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M & L cleaning of old concrete floor by roughening, picking, sweeping, clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Material and labour brushing neat cement slurry with 3.0 kg of cement per square metre in floor complete all as specified and as directed by the Engineer-in-Charge
M&L Non Skid coloured ceramic tiles joint free premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour Non Skid coloured ceramic tiles joint free premium/1st quality 7 to 8 mm thick, of same description as of floor tiles as in serial item No 14 above but 100 to 200mm height as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/ skirtings/dados of size 450x300x7mm thick or nearest size as required , set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour rendering 10 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15 mm thick on brick work or concrete wall surfaces in cement mortar 1:4 including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately)
Supply only water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster 15 mm thick in cement motar 1 :4 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:4 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 05 mm thick on any faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller over a coat of alkali resistant primer over and inlcuding 2mm to 3mm thick wall care putty white cement based in two or more coats to achive smooth surface complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller over a coat of alkali resistant primer complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of newly plastered / unplastered surfaces of ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of newly plastered / unplastered surfaces of walls and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old decorated plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engr-in-charge.
Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engr-in-charge.
M&L rolled mild steel framed work as in chowkats of door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-W (Grade E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required,hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm prelam PVC sheet reinforced with MS square tube, and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
S&F double shutter steel window box type ERW hollow P section comprising of glazed/gauged skeleton shutter fabricated from following sections :- (a) ERW hollow P section frame of size 60 mm x25 mm made from 1.25 mm thick MS sheet (02 Nos i.e. 01 for glazed shutter and 01 for gauzed shutter ). Both P section shall be welded with flat iron 25x03 mm thick all around of frame on both inner and outer faces . (b) Style and rails of window shutters shall be fabricated with ERW hollow P section of size 50 mm x25 mm made from 1.00 mm thick MS sheet and comprising of 02 Nos sash bars for glazed window leaf of T – section 20 x 03 mm thick and one No sash bar of 20 mm x 3 mm thick section for gauzed winodw leaf . (c) Vertical mullion shall be ERW hollow T -section of size 60 x 25 mm made from 1.25 mm thick MS sheet (d) The above steel window shall be deemed to include the following accessories/ fittings : i) Hold fast 150mm long mild steel flat iron 12x3 mm thick made to shape- 04 Nos per window ii) Handle of Z section 20mmx25mm, 100mm long – 01 No per leaf. iii) MS tower bolt stove enamelled 150mm long- 2 Nos per leaf. iv) Z section 20mmx25mm, 100mm long stopper – 01 No per leaf. (v) Cleat 55 mm long of solid square 15x20x.63mm square - 01 No per leaf
item No. 36 (contd....) vi) Pintal hinges 12 x 75 mm - 2 Nos each leaf vii) 10mm square Guard bar @ 10 cm c/c welded to frame . (viii) Two coat of Synthetic enamel paint over one coat of red oxide primer. (ix) 0.36mm nominal dia of stainless steel wire mesh and average width of aperture of 1.40mm fixed in gauzed skelton shutter of window with flat iron 15 x 03 mm with steel screws . (x) 3mm thick sheet glass, ordinary quality and with oil putty in square n. exc 0.5 sqm in each pane fixed in glass shutter of window. (xi) Fabrication and fixing arrangements as per specification including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 /cement plaster 1:4 as require and make finish good to the existing surface complete all as specified and directed. Notes : (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery, grill and other accessoriries as mentioned above. (iii) The window upto 1.00 metre width shall consists of two leaves both for gauzed shutter and glazed shutter and all the shutters are openable. The window more than 1.00 metre width shall have two openable leaves on both outer side for gauzed shutter and glazed shutter and middle leaf/shutter shall be fixed type.
S&F box type using ERW hollow 'P' section of size 60 x 25mm made from 1.25 mm thick MS sheet ventilators fixed type with glazing bar including MS grills of square bar 10mm dia @ 100 c/c complete with glazing bars dovetailed or welded, including two coat of synthetic enamel ordinary tint paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing stainless steel butt hinges 100mm long medium weight cold rolled complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 500 ltr and not exc. 1000 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing water storage tank, 1000 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm dia high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore, complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing water storage tank, 500 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm dia high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore, complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair 20mm dia float valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minium weight-210 grm) complete all as specified and as directed by the Engineer-in-Charge.
S & F 15 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified & directed by the Engr-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in treches or in floor complete all as specified and as directed by the Engineer-in-Charge
S&F 110mm bore PVC (SWR) bends of any radius, complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) juction single (Single T) equal are unequal complete all as specified and as directed by the Engineer-in-Charge.
M & L 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement as in repair complete all as specified and as directed by the Engineer-in-Charge.
M & L 125/110 mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in treches or in floors complete all as specified and as directed by the Engineer-in-Charge
S&F 75mm bore PVC (SWR) bends of any radius, complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC (SWR) juction single (Single T) equal are unequal complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest & PVC SWR 'P' or 'S' trap of pressure rating 6 Kg per square cm complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, PVC waste pipe , providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
S&F 32 mm dia PVC waste pipe of standard length for wash hand basin / Kitchen sink etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy fancy type chromium plated stop valves with long shank and cup (concealed type), screwed down, high pressure with capstan head, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated angular stop valves with capstan head, screwed down, high pressure scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated shower rose 125mm size round/ square type swivel type with arm of standard size as per site as in repair complete all as specified and as direced by the Engineer-in-charge.
S & F as in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S & F shelf of PTMT fixed with and including brass chormium plated screws and wooden/plastic cleats (minium weight-300 grm) complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated with long body, wall flanges and capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair complete all as specified and as directed by the Engineer-in-Charge.
M & L cleaning of old concrete roof by roughening, picking, sweeping, clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Material and labour brushing neat cement slurry with 3.0 kg of cement per square metre on RCC roof surface complete all as specified and as directed by the Engineer-in-Charge
M & L providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof kerbs, mud stops padding and finished even and smooth without using extra cement including form work where ever required complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shall be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases to brick wall built in cement mortar, pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
M & L concrete bed to drain pipes of 150mm bore, including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge
S & F 150mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in treches or in floor complete all as specified and as directed by the Engineer-in-Charge
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness including cover fillets and false ceiling frame work of any size/ description complete all as specified and as directed by the Engineer-in-Charge.
S & F GI metal suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, and as directed by Engineer-in-charge. Including 4mm thick HPSC pre-prime non asbestos fiber cement building board (E-classic or eqivalvent) decorative finish fixed to frame work with holding down clips in false ceiling complete all as specified and as directed by the Engineer-in-Charge
M & L reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in pillars, posts,struts, piers, columns and stanchions complete all as specified and as directed by the Engineer-in-Charge.
Formwork to sides of pillars, posts,struts, piers, columns and stanchions flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (design Mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC M-25 (design mix) using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 CM thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 5mm dia and over up to and including 10mm dia in stirrups, spacers etc, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
M & L 25 mm thick PCC 1:2:4, type B0 as in sub base floor (using 12.50mm graded crushed stone aggregate), finished even & fair without using extra cement complete all as specified and as directed by the Engr-in-charge.
M & L PCC 1:4:8 Type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium section (minimum thickness of powder coating 50 micron) work for doors,windows & ventilators frames with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws complete all as specified and as directed by the Engineer-in-Charge. Note : (a). Weight of aluminium sections shall be as per IS or actual weight which ever less shall be measured. (b). The rates quoted shall be inclusive of neoprene beading, jointing clips, screws, etc as required and the same shall not be measured for arriving the weight;
S&F powder coated aluminium section (minimum thickness of powder coating 50 micron) for doors,windows & ventilators shutters including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws complete all as specified and as directed by the Engineer-in-Charge. Note : (a). Glazing shall be measured and paid separately; (b). Weight of aluminium sections shall be as per IS or actual weight which ever less shall be measured. (c). The rates quoted shall be inclusive of neoprene beading, glazing clips, jointing clips, screws, etc as required and the same shall not be measured for arriving the weight; (d). The rates shall be inclusive of locking arrangement including complete packing with silicon gel alround contacting surface of aluminium framework and including matching the existing surface area complete all as specified and directed.
M & L frosted sheet glass 4.8mm thick and glazing with aluminium snap beading, rubber gasket in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
M & L frosted sheet glass 3.00mm thick and glazing with aluminium snap beading, rubber gasket in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
M&L 12 mm thick prelaminated particle board exterier grade (grade-1) confirming IS 14587 prelaminated both side with decorative choice lamination and fixed to aluminium door shutter with glazing clips, rubber complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel curtain rod 25mm dia having wall thickness 1.00mm with and including stainless steel decorative brackets, two lotto for each rod length at both end etc fixed with stainless steel screws complete all as specified and as directed by the Engineer-in-Charge.
S&F 5 to 6mm thick mirror including ingraved any pattern, with wooden beading of any size fixed to wall with chromium plated brass screws and cup washers and all connected fitting complete all as specified and as directed by the Engr-in-charge.
S & F brass chromium plated hand shower ( health faucut) with 8 mm dia 1.2 mtr long flexible tube and wall hook with NRV ( back flow preventor )complete fixed to wall complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ALD577 or equivalent in Kohler/Cera/Hindware
Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc. 63mm, deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, and making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 (using 20mm size crushed stone aggregate) smooth finished and reforming benching as required of pipe 110 mm dia,complete all as specified and as directed by the Engineer-in-Charge.
M & L concrete bed to drain pipes of 110mm bore, including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge
M & L providing PCC precast 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, precast cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weathering, throating etc and setting CM 1:4 complete with joints to match, complete all as specified and as directed by the Engineer-in-Charge.
M & L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by the Engineer-in-Charge.
M & L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm prelam PVC sheet on single side used instead of plain colour PVC sheet reinforced with MS square tube, edges will be painted to match with prelam sheet and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in holdfasts complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair bib tap 15mm dia brass chromium plated fancy type with capstan head, screwed down for iron pipe of make : Jaquar Cat Part No. FUS–29037 or equivalent in Kohler /Cera /Hindware and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair 15mm bore brass chromium plated angular stop valves with capstan head, screwed down, high pressure scrwed both ends for iron pipe or for unions of make : Jaquar Cat Part– FUS–29053 or equivalent in Kohler /Cera /Hindware complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair brass chromium plated exposed body for single Lever basin mixer, wall Mounted consisting of operating lever, cartridge sleeve, wall flange, nipple & spout for 15mm dia pipe including brass chromium plated conceled of make:- Jaquar Cat Part No FUS–29233NK and ALD–233N/235N respectively or equivalent in Kohler /Cera/ Hindware with all connecting fittings complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair rimless single piece WC with UF slim seat cover, hinges, cistern with fixing accessories and accessories set, fittings etc of size, 380x670x765 mm and S Trap–300mm of make : Jaquar Cat Part No FSS–WHT–29853S300UFSM or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair viterous china white table top wash hand basin of size 470x470x110 mm, fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc of make – Jaquar Cat Part No. FSS–WHT–29901 or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair vitreous china sensor type urinal of size 480x300x740mm including sensor, waste coupling, flush pipe, spreder and waste pipe etc with all accessories securing urinal to plugs with and including 60mm long brass screws, complete all as specified and as directed by Engr–in–Charge.
S&F as in repair curved shaped urinal partition with frosted glass 10mm thick, height 900mm, width 450mm of make – Jaquar Cat Part No. : JSE–CHR–110UC450X or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by Engr–in–Charge.
S&F stainless steel Towel Rack 600mm long with lower hangers between flanges including brackets of make : Jaquar Cat Part No : AKP–35781PS in Kohler /Cera/Hindware and fixed with brass screws complete all as specified and as directed by Engr–in–Charge.
S&F stainless steel single towel rail 20 mm dia D type 600 mm long between flanges including brackets of make :Jaquar Cat part No : AKP–35711PS or equivalent in Kohler /Cera/Hindware and fixed with brass screws complete all as specified and as directed by Engr–in–Charge.
S&F as in repair fancy type stainless steel towel ring squre, fixed with brass screws of make : Jaquar Cat Part No : AKP–35721P or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by Engr–in–Charge.
S&F fancy type stainless steel toilet paper holder recessed type including fixing with brass screws to wall of make : Jaquar Cat Part No : AHS–1551 or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by Engr–in–Charge.
S&F glass shelf with bracket including fixing with brass screws to wall of make : Jaquar Cat Part No : AKP–35771P or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by Engr–in–Charge.
S&F corner glass shelf with bracket including fixing with brass screws to wall of make : Jaquar Cat Part No : ACN–1173 or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by Engr–in–Charge.
S&F fancy type soap dish holder including fixing with brass screws to wall of make : Jaquar Cat Part No : AKP–35731P or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by Engr–in–Charge.
S&F thumbler holder including fixing with brass screws of make : Jaquar Cat Part No : AKP–35741P or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by Engr–in–Charge.
S&F soap dispenser with glass bottle including fixing with brass screws Make : Jaquar Cat Part No : AKP–35735P or equivalent in Kohler /Cera/Hindware complete all as specified and as directed by Engr–in–Charge.
Schedule 'A' Part-II (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 145 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No.145 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No.145 but for for one light point controlled by two way switch complete all as specified and as directed by Engineer-in-Charge.
Description same all as per srl item No 145 here-in-before but for one socket outlet 15 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Description same all as per srl item No 145 here-in-before but for one socket outlet 15 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, two way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F electronic Fan regulator modular 100 watt, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing indoor decorative surface mounting LED tube light fitting box type 18/20 watt with electronic driver, opal diffuser, high efficient PVC housing body suitable for LED tube, AC 220-240 volts, 50 Hz and including 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, auminum housing, surge protection including driver & LED lamp etc complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair LED Bldg Security Light Fittings of capacity 20 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver, service bracket of MS pipe 25 mm bore medium grade of length 0.90 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to MS pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, complete all as specified and as directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces as in repair complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces as in repair complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB SP, 6-40 Amps, 240 volt,10 KA , 'C' curve as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN, 32/40 Amps, 240 volt,10 KA , 'C' curve as in repair complete all as specified and as directed by the Engineer-in-Charge.
Taking down ceiling fan 1200mm sweep, after disconnecting the all electrical connection carefully and dismantling of blades including scraping the old paint ,cleaning and washing with washing powder, filling cavities with filler and painting to ceiling fan by using synthetic enamel paint in two coats by spray and reassembling, testing and refixing/rehanging the ceiling fan and connecting up including provision of flexible cable 23/.0076 from ceiling rose or connector to fan complete all as specified and as directed by the Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
S & laying as in repair sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing as in repair complete all as directed by Engineer-in-Charge and earth testing on completion .
Supply and laying XLPE insulated, armoured heavy duty electric cable 16 sqmm cross sectional area, 4 core with aluminium conductor, 1100 volts grade as in repair complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, GI pipes and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 32mm dia for cable protection and fixed with clamp to pole and wall with nut, bolts, washers or in trenches complete all as specified and as directed by Engineer-in-Charge
M&L dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supply and laying well burnt brick class-B laid flat to cover the cable with width equal to the length of cable and abutting each other for protection of cable complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M & L PCC 1:3:6 Type C-2 using 40mm graded crushed stone aggregate as in filing of road cutting / hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth, for laying of cables, GI pipes and getting out in hard/dens soil i.e cutiing existing hard standing/PCC/WBM complete all as specified and as directed by Engineer-in-Charge.
S&F LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down unserviceable bulbs complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) with and including MCCB 100 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fixing of heavy duty exhaust fan 300mm sweep with corrosion resistant PVC body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, PVC base frame with rubber mountings for silent operation, maximum watt input not more than 410 watt, 1200 RPM, PVC blades and shutter type louvers self-openable/ closeble for protecting the entrance of birds as per IS :2132-1967 and testing complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Water heater (Geyser) storage type electric of capacity 25 Ltrs , BEE 5 Star rated, ABS body, metal tank with glasss lined coating, multiple heating option, shock safe plug, puf insulation, incoloy glass coated anode rod / copper heating element of capacity 2KW with ISI mark , adjustable knob for temp setting with minimum 8 Bar high working pressure, multi functional safety valve & whirl/Swirl flow technology, thermostat electronic type, thermal cutout capillary type complete including superior quality copper connection pipe heavy duty 15mm dia 450mm long, brass adopter for water connection with nikhel coated ISI marked with fastner, nut bolts, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per existing surface, connecting to inlet and outlet valves, testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of heavy duty wall mounting fan 300 mm sweep with corrosion resistant PVC body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, rigid frame , 1200 RPM, PVC blades and testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED decorative mirror light fitting with tunable high out put diffuser , 10 watt, 220 volts, AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing tunable LED luminaire 600 mm x 600mm, 35/36 watt, 220 volts, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
shiv const co
Durga Enterprises
Swami Enterprises
Ashwani Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .