Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 133 GARFA MAIN ROAD KOLKATA 700 078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L1 | Accepted-AOC For being L1 bidder. | |
| 2 | L2₹13.7 L+₹2.4 L (21.8%)Rejected-Finance | L2 | Rejected-Finance For being L2 bidder. | |
| 3 | L3₹13.7 L+₹2.5 L (22.0%)Rejected-Finance | L3 | Rejected-Finance For being L3 bidder. | |
| 4 | L4₹14.4 L+₹3.2 L (28.5%)Rejected-Finance | L4 | Rejected-Finance For being L4 bidder. | |
| 5 | L5₹14.8 L+₹3.6 L (32.1%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L5 | Rejected-Finance For being L5 bidder. |
Tender Value
Refer Docs
EMD Value
₹36,061
Closing Date
5 Mar 2021, 5:00 pmClosed
EXECUTIVE ENGINEER
TOP FLOOR, MECHANICAL COMPLEX, BAGUIATI, KOLKATA_700 059.
Complete renovation of Electrical Installation of Fabrication and Automobile Workshop at ITC Ramkrishna Mission Boys Home, Rahara after Amfaan devastation under Barrackpore Electrical Sub-Division, PWD.
2021_WBPWD_323782_1
WBPWD/EE/N24PRG/ELEC/224/20-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
40 days
ITC Rahara
Please refer Tender documents.
6 documents required · 6 mandatory
₹36,061
5 Aug 2021
5 Feb 2021
8 Mar 2021
6 Feb 2021
5 Mar 2021
15 Feb 2021
Amount
Dismentling Of whole EI installetion incl. mending goods and dameges.
S/F of 415V, 200 A SFU in SS enclosure on angle iron frame with DIN type HRC fuse and 2 nos. Cable end box as per GS -1 no. (Make: Siemens/ L&T)
S & F of the following switches on angle iron frame on wall with necy. Connection as per direction of EIC. (Emergency Panel) (L& T make) a)S/F of 415V, 200 A SFU in SS enclosure with HRC fuse and 2 nos. Cable end box -1 no. b) S/F of 4 Cu. bar of 315A BBC with porceline chair having length 850mm. bar size (4 X 15X3mm) with metal box (500 X 150mm) as to GS- 1 no. c) S/F of 415V, 125A SFU in SS enclosure with HRC fuse and 1 nos. Cable end box -2 no. d) S/F of 415 V, 200A TPN on load front operated Changover switch- 1no
S & F 500V 12 way Vertical TPN MCBDB (Double door) having 4way /phase comprising of 1 no. 125A 4-pole MCCB as Incomer & 12 nos. 63 A TP MCB (C curve 10 KA) as outgoing,with necy interconnection & earthing attachment incl S&F cable end box, flashed in wall. (Legrand/ Crabtree)
S & F 415V 16-32 Amp per way 6 way TPN MCBDB with SS enclosure double door with IP 42/43 protection with 4 pool 63 Amp MCB isolator as incomer and C curve 10KA SPMCB’s as outgoing concealed in wall after wall cutting and mending good the damages to original finish including interconnection with suitable six=ze of Cu wire neutral link and earthing attachment. 4 way Enclosure (607715), 63A FP Isolator, 18 no. (16-32 Amp)SPMCB. (Make Legrand/L & T/ Crabtree).
Supplying and fixing double-door 2+12 way SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to GS (40A DP Isolator as incomer and 12Nos SPMCB as out going( C curve 10KA ). ( Make-Legrand/ Havells.)
Supply & laying of 1.1 KV grade the following sizes XLPE/PVC insulated armoured Al. cable (Polycab/Gloster /Havells Make) as per GS. i) 4 core 95 sq.mm cable( Through under ground trench)( for generator to panel )
ii)4 core 50 sq.mm cable (recessed in wall ) with 2x10 SWG GI wire
iii)4 core 25 sq.mm cable (recessed in wall ) with 2x10 SWG GI wire
S & F compression type cable gland complete with brass gland, brass ring, rubber ring for dust & moisture proof entry of PVC/XLPE Armoured cable & finishing end of the same as per GS for the i) 4 core 95sq.mm cable
ii)4 core 50 sq.mm cable
iii)4 core 25 sq.mm cable
Wiring with the following sizes pvc insulated copper wire FR (Finolex/ Havells /Polycab )in 19mm 3mm bore polythine pipe embeded in wall incl. all accessories as to GS. i)2x6+1x4 sq.mm (sub-main line)
ii) 4x4 + 2x2.5 sq.mm ( for work shop)
iii)2x2.5+1x1.5 sq.mm (power pluge & computer board)
iv) 3x1.5 sq.mm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/ Havells/ Polycab) forECC partly in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall for vertical run and partly in 20mmsize PVC rigid conduit FR (Precision make) for ceiling portion only, incl. necy. fittings as reqd. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [ PVC rigid conduit only for horizontal run & above false ceiling and vertical run concealed ]( AV run 12mt.)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire Finolex/Havells/Polycab) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories on wall to 240 V 5A 3 pin plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) on wall incl. mending good damages to original finish. a) on board
S & F 250V 6 pin 20 amp flush type socket with 20 A switch in sheet metal box (150X100X65mm) MS (16SWG) with bukelite top cover recest in wall incl earthing attachment as per GS. (Make:-Anchor)
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.
S & F 415 V 32 A MCB of breaking capacity 10 kA in SS enclosure. Including SS enclosure box. (Make:- Legrand/ L & T/ Crabtree)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
S & Fixing only 1200mm sweep ceiling fan (Make ORIENT Quasser Ornamental Shine/ CG aora prime antidust/ Usha Striker Galaxy) complete with blades, canopy, fork, rubber bush, down rod (14 SWG) etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S.
S&F 12" sweep 1440 RPM (EPC heavy duty make) 230V A.C. Exhaust fan after necy. Wall cutting , plastering etc. grouting nut bolts incl. S&F louver shuttering as per direction of EIC
S&F socket type fan regulator(step type) (Anchor) on existing sheet metal switch metal switch board with bakelite top cover by screw incl. making neccesery connection after cutting as per GS.
S &F 4 feet single 22wt. LED light fittings ( Philips TMC-501 P 1 X T-LED 22W P3241/ Crompton IGP161LT8-16) complete with 2 nos. 20 mm dia. E.I. conduit (14SWG) supports fixed with " L " type MS clamp whose one side inserted within the ceiling reinforcement and other side connected with the suitable size all accessories with 4 ft, 18Wt LTT8 -20. LED essential lamp (Philips MAS LED tube 1200mm 18W 865 T81-2100lm/ Crompton LTT8-20) (Make:- Philips/ Crompton)
S &F 4 feet twin 22wt.LED light fittings ( Philips TMC-501 P 2 X T-LED 22W P3242/ Crompton IGP162LT8-16) complete with 2 nos. 20 mm dia. E.I. conduit (14SWG) supports fixed with " L " type MS clamp whose one side inserted within the ceiling reinforcement and other side connected with the suitable size all accessories with 2 nos 4 ft, 16Wt LTT8 -20. LED essential lamp (Philips MAS LED tube 1200mm 18W 865 T81-2100lm/ Crompton LTT8-20) (Make:- Philips/ Crompton)
S&F reccess Mount indoor comercial full glow 2x2 ft. LED luminarires (Make- Crompton LCTLRF5-36-CDL/ Phillips, Wipro equivalent)
Earthing the whole installation by 50mm dia. GI (ISI-M) pipe as to GS. For excavation soft soil as per GS.
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
SATABDI ENGINEERING COMPANY
Messrs HI- Q - ENTERPRISE
M/S T AND D ENGINEERING WORKS
Electromech Engineers Co-Operative Society Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .