| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.7 L+₹1.3 L (3.82%)Rejected-AOC | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹35.4 L+₹2.1 L (6.17%)Rejected-AOC 37 SUBHASH NAGAR AIR FORCE JODHPUR 342 008 | JODHPUR | JODHPUR | RAJASTHAN | 342008 | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹38.3 L+₹4.9 L (14.8%)Rejected-AOC 19 PAOTA C IIIRD ROAD JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-AOC Not lowest | |
| 5 | L5₹38.5 L+₹5.1 L (15.3%)Rejected-AOC | L5 | Rejected-AOC Not lowest |
Tender Value
Refer Docs
Closing Date
23 Oct 2021, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
ADDN/ALTN TO L/IN OFFICERS BLOCK (HABIBULLAH AND BHATIA), RUNWAY CONTROLLER HUT, RATION STAND IN LOGISTIC SECTION AND MISC B/R WORKS AT AF STN JODHPUR
2021_MES_478108_1
8489/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
Exempted
29 Oct 2021
27 Sept 2021
25 Oct 2021
27 Sept 2021
23 Oct 2021
11 Oct 2021
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in levelling course for laying floor finishes, surfaces finished even and fair without using extra cement complete all as specified and as directed by the Engineer - in - Charge.
Material & labour for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, light shade, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed by Engr-in-Charge.
Dismatling floor hearth or wall tiling including cement mortor bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing Glazed ceramic tiles, coloured, in vertical surfaces 450mm x 300mm x 7.8mm thick, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick screed bed in cement mortar 1:4 complete all as specified & directed by the Engineer-in-Charge.
Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed by the Engineer - in - Charge.
Supply and fixing Anodised aluminium snap grid frame work (600mm X 600 mm) including hangers, ceiling cleats of GI and expansion hold fastners for false ceiling complete all as specified & directed by the Engineer-in-Charge.
Material and labour for 10 mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium as per specification and drawing as per SSR part-1 complete all as specified and directed by Engineer-in-charge.
Supply and fixing uPVC insulation window fixed type with double glazed unit, with all glasses toughened to achieve 60 dB of sound reduction, and uPVC profile tested for 8000 hours against light UV material mix. uPVC outer wall profile will be 2.5 mm thick to ensure the weld strength considering heavy glass panels. Gasket to be black colour EPDM. all hardware spang rods to be stainless steel 304 grade, including all other fixing accessories as required to fix window panels complete all as specified and directed by Engineer-in-charge.
Supply and fixing uPVC insulation door/window frame with double shutters with openable panels with double glazed unit, with all glasses toughened to achieve 60 dB of sound reduction, and uPVC profile tested for 8000 hours against light UV material mix. uPVC outer wall profile will be 2.5 mm thick to ensure the weld strength considering heavy glass panels. Gasket to be black colour EPDM. all hardware spang rods to be stainless steel 304 grade, including all other fixing accessories as required to fix door/window frames/shutters complete all as specified and directed by Engineer-in-charge.
Material & labour for brushing neat cement slurry @ 3 Kg of cement per sqm of surfaces complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 40mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in levelling course/ roof padding with & including , surfaces finished even and smooth without using extra cement on roof / chajjas etc complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 15 mm thick rendering on green concrete roof surfaces in Cement Mortar 1:4 with & including water proofing compound @ 3% by weight of cement, on concrete surfaces while concrete surface is green on roof, finishing even and smooth without using extra cement complete all as specified & directed by the Engineer-in-Charge. Note:- WPC shall be measured and paid seperately.
Supply only Integral water proofing compound (ISI marked) complete all as specified & directed by the Engineer-in-Charge.
Material and labour for preparation of concrete surfaces and applying bituminous primer (conforming to IS : 3384-1965 ) @ 0.40 Kg/Sqm complete all as specified & directed by the Engineer-in-Charge.
Material & labour for applying evenly a tack coat of industrial bitumen of grade 85/25 @ 1.2 kg per sqm including cleaning surfaces ( Ist coat for bonding material below membrane and IInd coat on top of membrane. Each coat shall be measured and paid seperately) complete all as specified & directed by the Engineer-in-Charge.
Supply and laying Atactic polypropylene modified polymeric standard membrane of minimum 3 mm thickness, weight not less than 3kg/sqm,reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm), made out of 90 micron high density polyethylene (ATACTIC POLY PROPYLENT BASED) laid on primed surface by forced application and finally finished with aluminium paint @ 0.20 litre per sqm complete all as specified & directed by the Engineer-in-Charge.
Material and labour for preparation of surfaces and applying aluminium paint by brushing @ 0.25 Kg/Sqm on APP membrane complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 100 mm thick,PCC 1:4:8, type D-2, (using 40 mm graded crushed stone aggregate), as in sub base or flooring complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 10 to 12 mm thick vitrified unglazed and unpolished, scratch resistant, matt finished coloured tiles (square/rectangular) of size not less than 300mm x 300mm as in parking/hardstanding or similar works etc set, jointed in cement slurry and pointed in white or coloured cement to match the colour/ shades of tiles complete all as specified and directed by the Engineer-in-Charge.
Material & labour for surface dressing not exceeding 15 cm deep and site clearance in soft/loose soil complete all as specified & directed by Engineer-in-Charge.
Taking down cement or cement lime plaster work any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 15 mm thick rendering in cement mortar 1:6 on stone masonary surfaces or surface other than fair face of brick work of walls including surface finished even and smooth without using extra cement complete all as specified & directed by the Engineer-in-Charge.
Material & labour for prepration of new plastered surface of wall and applying two coats of oil emulsion distemper over a coat of alkali resistant primer etc complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting existing water storage tanks of any capacity setting aside or removing from site if required for repair, cleaning etc. hoisted if required and reconnecting and re-fixing in position complete all as specified and directed by Engineer-in-Charge.
Material & labour for dismantling existing water storage (PVC/RCC/AC) tanks of capacity exceeding 500 litres but not exceeding 1000 litres and removing from site to store complete all as specified and directed by Engineer-in-Charge.
Supply and fixing rotational moulded polyethylene water storage tank of capacity 1000 ltrs (Cylindrical vertical with closed top), triple layer construction, ISI marked hoisted & fixed in position including 20 mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified and as directed by the Engineer - in - Charge.
Demolition and breaking up any dia (75 to 250 mm) bore Asbestos Cement drain pipes, soil , waste and rain water pipes etc set in cement mortar, from walls or in floors, including connections and fittings complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 160 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including clamps and other fixing accessories complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing PVC (SWR) bend any radius, of 160 mm bore complete all as specified & directed by the Engineer-in-Charge.
Taking up or down steel tubing of 15 mm bore pipe and connection including cleaning for re-fixing, removal to store or taking in credit complete all as specified & directed by the Engineer-in-Charge.
Taking up or down steel tubing of 20 mm bore pipe and connection including cleaning for re-fixing, removal to store or taking in credit complete all as specified & directed by the Engineer-in-Charge.
Refixing of 15mm bore old steel tubing & connection in new or old position (walls, ceilings, floors etc) complete all as specified & directed by the Engineer-in-Charge.
Refixing of 20mm bore old steel tubing & connection in new or old position (walls, ceilings, floors etc) complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 20 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 15 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Bib taps, fancy type, chromium plated, 15 mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing in repairs two way brass chromium plated fancy type bib cock of 15mm bore complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs 15 mm bore fancy type brass chromium plated Wall mixer with telephonic arrangement and with pipe bend 3 in 1 screwed down complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs 15 mm bore fancy type overhead shower with arm swivel joint chromium plated screwed down, of size 300mm x 300 mm complete all as specified & directed by the Engineer-in-Charge.
Supply and fixing in repairs 15 mm bore center hole basin mixer brass, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks & fly nuts for iron pipe complete all as specified and directed.
Supply and fixing in repairs of brass Chromium plated angle Stop valves of 15mm bore screwed for 15mm bore iron pipe or union complete all as specified and directed
Supply and fixing in repairs of brass Chromium plated fancy type 15 mm bore stop cock with long shank & as concealed type complete all as specified and directed.
Supply and fixing in repairs of PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Supply and fixing in repairs of vitreous china wash down water closet pan wall hung snow white with extended P trap including vitreous china flushing cistern with twin flush and seat cover, connection to drain flush pipe and anti syphonage pipe complete all as specified and directed. Make CERA cat Part no 2035 (CLAIR) wor WC wall hung, cat part no 2115, 2235 for flushing cistern and cat part no 2315 for seat cover; or equivalent in makes given in Appx 'B' as aprove by GE.
Supply and fixing in repairs of vitreous china WHB white flat back size 550mmx400mm on new MS brackets excluding taps, waste pipe & plug, but including MS bracket etc complete all as specified and directed.
Material & labour for 8 to 10mm thick Glazed Vitrified Tiles (GVT) of size not less than 300mm x 600mm, light colour, including pattern/highlighter as approved by Engineer-in-Charge (square/ rectangular) as in skirting/dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15 mm thick rendering in cement mortar (1:4) mixed with chemical as required complete all as specified and as directed by Engr-in-Charge.
Material & labour for Non skid glazed ceramic tiles , light colour (square/rectangular) of size 600mm x 600 mm, thickness more than 9 mm, as in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed by Engr-in-Charge.
Supply & fixing Factory made solid WPC door frame of size 100mm x 50mm of premium grade complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing Factory Made Solid prelaminated PVC Moulded Door Shutters 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm coloured PVC Sheet on back face, and fixing complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing 150 mm long stainless steel, barrel tower bolts of extruded section and fixed (ISI Marked) complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 300 mm long stainless steel, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy (ISI Marked) complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing mild steel butt hinges, medium weight, cold rolled, mild steel of size 125 mm complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing stainless steel handles of size 125 mm (ISI Marked) complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including clamps and other fixing accessories complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including clamps and other fixing accessories complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing PVC (SWR) bend any radius provided with access door, of 75 mm bore complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing PVC (SWR) bend any radius provided with access door, of 110 mm bore complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 75 mm PVC (SWR) branch piece single (Y) equal or unequal bend provided with access door inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 110 mm PVC (SWR) branch piece single (Y) equal or unequal bend provided with access door inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 75 mm dia PVC (SWR), junction single, (Single T) equal or unequal provided with access door inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 110 mm dia PVC (SWR), junction single, (Single T) equal or unequal provided with access door inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing PVC (SWR) vent Cowl 110 mm dia complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing PVC (SWR) P/S trap 125/110 mm bore inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing PVC (SWR), 75mm dia Floor Trap, with grating including jointing with solvent cement inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing PVC (SWR), 125/110 mm dia of Gully Trap, with grating including jointing with solvent cement inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.
Material & labour for point wiring for One light / fan/ exhaust fan point controlled by one switch 5 Amp, SP, one way 240 volts, with 1.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium grade rigid PVC conduit (ISI marked) concealed, with all accessories including sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour complete all as specified & directed by Engineer-in-Charge.
All as per item No 67.00 above but one 5 Amp 3 pin switch socket outlet point on same board.
All as per item No 67.00 above but one 5 Amp 3 pin switch socket outlet point controlled by one switch on independent board.
Material & labour for surface point wiring for One light / fan/ exhaust fan point controlled by one switch 5/15 Amp, SP, one way 240 volts, with 2.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium grade rigid PVC surface conduit (ISI marked) concealed, with all accessories including sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover including 2.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour complete all as specified & directed by Engineer-in-Charge.
Supply & fixing modular switches 6 amps single pole one way, one module capacity 230 V complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular socket 6 amps, 2/3 combined 2 modules of capacity 230 V complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular socket outlet multipurpose 3 pin 16 amps and two pin 6 amps controlled by one switch complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular switches 16 amps single pole one way, one module capacity 230 V complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular cover plate with frame 03 module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular cover plate with frame 04 module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular cover plate with frame 06 module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular flush metal boxes with frame 03 module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular flush metal boxes with frame 04 module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular flush metal boxes with frame 06 module complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB, C-curve, SP 240 Volts, breaking capacity 10 kA, conforming to IS 8828 of rating 05 to 32 Amps, including required wiring, connections with copper lugs of suitable size, for fixing in MCB DBs complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing MCB, C-curve, SPN 240 Volts, breaking capacity 10 kA, conforming to IS 8828 of rating 40 Amps, including required wiring, connections with copper lugs of suitable size, for fixing in MCB DBs complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing MCB distribution board SPN, 12 ways, 230 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints, having insulated 200 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, inter connections, earthing connections complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cables of suitable size complete all as specified and directed by Engr-in-charge.
Supply and fixing LED light fitting 1x9 W/ 1x10 W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge.
Supply and fixing LED light fitting 1x18 W, 220 V AC box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 6 sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC surface conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed, with one 6 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Supply & fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 415 volt including MCB SP 20 amps complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing LED street light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed by Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead 4 mm dia, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 20 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
Supply & fixing LED aviation obstruction light red colour comprising of aluminium housing with polycarbonate enclosure single phase 240 V with and including suitable fixing arrangement of GI pipe 40 mm dia 1.5 metre high at the top of runway controller hut complete all as specified and directed by Engineer-in-Charge.
Fixing, installation, testing & commisioning of 1.5 Ton Split AC (Outdoor unit & indoor unit both) with & including provision of MS powder quoted stand for outdoor unit, PVC drainage pipe of reqd size & length for drainage of water complete all as directed by the Engineer-in-Charge. Note :- Split AC (Outdoor & Indoor unit) with 3 metres long copper tubing, remote shall be issued by the MES free for fixing. If copper tubing is required more than the 3 metres, it shall be provieded by the contractor & nothing extra on this account shall be payable.
Taking down Distribution Board any type and size, any capacity and making good the disturbed surface Complete all as specified and directed by the Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. Complete all as specified and directed by the Engineer-in-Charge.
Material & labour for point wiring for one socket point on independent board, controlled by one switch 15 Amp, SP, one way 240 volts, with 2.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium grade rigid PVC conduit (ISI marked) concealed, with all accessories including sheet steel terminal / CI box including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour complete all as specified & directed by Engineer-in-Charge.
Supply & fixing modular socket outlet 2/3 pin 6/16 amps combined 2 module 230 V AC complete all as specified and directed by Engineer-in-Charge.
Supply and fixing factory made MCB distribution board SPN, 240 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, fixed on wall, with incomming MCB, C curve, SPN 40 Amps 16 KA 01 No and outgoing MCBs C curve 06 to 32 Amps single pole 06 Nos including necessary connections complete all as specified and directed by the Engineer in Charge.
Supply and fixing factory made MCB distribution board TPN, 240 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, fixed on wall, with incomming MCB, C curve, TPN 100 Amps 36 KA 01 No and outgoing MCBs C curve 25 Amps SPN 10 Nos including necessary connections complete all as specified and directed by the Engineer in Charge.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 6 sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC surface conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed, with one 4 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Material and labour for submain wiring with four single core PVC insulated multi stranded copper conductor cable FRLS of size 16 sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC surface conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed, with two 10 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Four runs of main wire and two runs of earth wire & casing shall be measured and paid as one length.
Supply and fixing electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounting metal cabinet of required size to accommodate MCCB 250KVA four pole 36 KA thermal and megnatic release adjustable type for incoming and 250 Amps current capacity bus bar for connecting the outgoing cable with all necessary accessories required for connections and mounting the cabinet etc complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 4 Core complete all as specified and directed by the Engineer-in-Charge.
Taking down old unserviceable LT power cable any size and type Complete all as specified and directed by the Engineer-in-Charge.
Taking down old unserviceable LT panel any size and type Complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation/cable trench/laying of pipe line/taking out pipe etc and getting out in hard/dense soil complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil to a distance not exceeding 50 m and deposing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Material & labour for stone slab 40 mm to 50 mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 cm to 30 cm wide and not less than 50 cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning complete all as specified and directed by the Engineer-in-Charge.
Supply and filling dry clean tibba sand in trenches for cushioning of underground cable including punning down complete all as specified and directed. Note:- Only Punned down thickness shall be measured and paid
Material & labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with & including GI pipe of 80 mm dia light grade complete all as specified and directed.
Material & labour for out door type LT Feeder Pillar box (Kiosk) of size not less than (L) 60 cm x (W) 45 cm x (H) 45 cm made out of 3.15 mm thick CRCA sheet (CPRI approved) with openable Front door including locking arrangement, with and inluding Copper Busbar 400 amps rating and one MCCB 250 Amps , 25 KA and fixed on angle iron frame of required size and embedded in PCC plinth made of PCC 1:4:8 type D1 as required complete all as specified and directed by the Engineer in Charge.
Narendra General Suppliers
DEV INDUSTRIES
Om Trading Corporation
BAGHELA CONSTRUCTION
Lalit Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .