| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L1 | Accepted-Finance OK | |
| 2 | L2₹26.6 L+₹1.9 L (7.54%)Accepted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | L2 | Accepted-Finance OK | |
| 3 | Rejected-Technical | - | Rejected-Technical DUE TO NOT FULL FILL TECHNICAL CRITERIA |
| Sl No | Description | Qty | Unit | Premier Engineering Company L1 | M G Traders and Engineers L2 |
|---|---|---|---|---|---|
| 1.01 | Work of Disconnection of LT power from the incoming panel and racking out the ACB /VCB during the execution of the work and shorting of all three phase during execution.1 | 2 | Job. | 10,000 ₹11,800 Lowest | 11,000 ₹12,980 |
| 1.02 | Supply & Installation of Power factor correction panel of 450 Kvar with following specifications. Incomer with 630 Amp MCCB
Outgoing
50 KVAR Feeder with capacitor duty contactor & accessories Qty 04 Nos.
25 KVAR Feeder with capacitor duty contactor & accessories Qty 04 Nos.
15 KVAR Feeder with capacitor duty contactor & accessories Qty 02 Nos.
10 KVAR Feeder with capacitor duty contactor & accessories Qty 02 Nos.
5 KVAR Feeder with capacitor duty contactor & accessories Qty 06 Nos.
3 KVAR Feeder with capacitor duty contactor & accessories Qty 03 Nos.
3.33 KVAR as fixed static capacitor for static/fixed load Qty 18 Nos.
On/Off indication light for each capacitor bank, MCB for Each Capacitor Bank, APFC relay (Programmable) shall be installed inside the panel.
Make of panel C&S/Siemens/BCH or any other DJB Approved.
Spares inside the panel and make of panel should be of same brand and certificate is to be enclosed along with Bid. | 2 | Job. | 19,50,000 ₹23,01,000 Lowest | 21,00,000 ₹24,78,000 |
| 1.03 | Dismantling of old APFC panel by opening its incoming and outgoing connection and lifting the same from the base by opening, cutting its angles and nut bolts as per site requirement. | 2 | Job. | 30,000 ₹35,400 Lowest | 31,000 ₹36,580 |
| 1.04 | Shifting of the old Panel from the existing location to the store as per instruction of site in charge using Hydra etc required at site. | 2 | Job. | 11,000 ₹12,980 Lowest | 12,000 ₹14,160 |
| 1.05 | Checking of the complete panel after completion of the work at site on load condition. | 2 | Job. | 15,000 ₹17,700 Lowest | 16,000 ₹18,880 |
| 1.06 | Work of replacement of burnt and damaged cable connected to the panel, Providing and fixing of LT tape and coating with epoxy paint.Work of insulating the panel mounted LT insulator with coating the Insulating busbar supporting insulator with dr. back epoxy gel coat. | 1 | Job. | 65,000 ₹76,700 Lowest | 68,000 ₹80,240 |
| 1.07 | Calibration of APFC relay along with checking of its functioning with increase in load, the work includes replacement of damaged wiring of panel relay metering etc. | 2 | Job. | 15,000 ₹17,700 Lowest | 16,000 ₹18,880 |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
30 Oct 2025, 2:15 pmClosed
EE
CHANDRAWAL WATER WORKS
Replacement of old damaged APFC Panel with static panel (02 Nos.) for Improvement of power factor at old pump house no. 2 Okhla water Works.
2025_DJB_279726_2
PRESS NIT NO. 06 (2025-26)/WW-III
Open Tender
Miscellaneous Works
Works
30 days
CHANDRAWAL WATER WORKS
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJBEMD A/c No-50448339804 THROUGH SUBPAISA GATEWAY
₹56,000
24 Nov 2025
13 Oct 2025
30 Oct 2025
13 Oct 2025
30 Oct 2025
13 Oct 2025
13 Oct 2025 - 30 Oct 2025
Work of Disconnection of LT power from the incoming panel and racking out the ACB /VCB during the execution of the work and shorting of all three phase during execution.1
Supply & Installation of Power factor correction panel of 450 Kvar with following specifications. Incomer with 630 Amp MCCB Outgoing 50 KVAR Feeder with capacitor duty contactor & accessories Qty 04 Nos. 25 KVAR Feeder with capacitor duty contactor & accessories Qty 04 Nos. 15 KVAR Feeder with capacitor duty contactor & accessories Qty 02 Nos. 10 KVAR Feeder with capacitor duty contactor & accessories Qty 02 Nos. 5 KVAR Feeder with capacitor duty contactor & accessories Qty 06 Nos. 3 KVAR Feeder with capacitor duty contactor & accessories Qty 03 Nos. 3.33 KVAR as fixed static capacitor for static/fixed load Qty 18 Nos. On/Off indication light for each capacitor bank, MCB for Each Capacitor Bank, APFC relay (Programmable) shall be installed inside the panel. Make of panel C&S/Siemens/BCH or any other DJB Approved. Spares inside the panel and make of panel should be of same brand and certificate is to be enclosed along with Bid.
Dismantling of old APFC panel by opening its incoming and outgoing connection and lifting the same from the base by opening, cutting its angles and nut bolts as per site requirement.
Shifting of the old Panel from the existing location to the store as per instruction of site in charge using Hydra etc required at site.
Checking of the complete panel after completion of the work at site on load condition.
Work of replacement of burnt and damaged cable connected to the panel, Providing and fixing of LT tape and coating with epoxy paint.Work of insulating the panel mounted LT insulator with coating the Insulating busbar supporting insulator with dr. back epoxy gel coat.
Calibration of APFC relay along with checking of its functioning with increase in load, the work includes replacement of damaged wiring of panel relay metering etc.
M G Traders and Engineers (BID ID -1634499)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_369158.xls
BOQ • 0.28 MB
PRESSNIT06B.pdf
Tender Documents • 0.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .