All Schedules Dismantling, shifting and handling over to TTD stores of existing 1 No 15 TR packaged unit along with its air cooled condesers - North side Dismantling, shifting and handling over to TTD stores of existing 3 Nos 7.5 TR indoor type Air Handling units - south side Earthing - 8 SWG GI Wire - North side Earthing - 8 SWG GI Wire - south side Painting of ducts with one coat of zinc chromate yellow primer and 2 coats of enamel paint of approved colour - North side Painting of ducts with one coat of zinc chromate yellow primer and 2 coats of enamel paint of approved colour - south side Providing of R-407C Refrigerant - North side Providing of R-407C Refrigerant - South side Supply and fixing of extruded aluminium double deflection type supply air grilles with vloume control dampers - North side Supply and fixing of extruded aluminium double deflection type supply air grilles with vloume control dampers - south side Supply and fixing of extruded aluminium duct mounted volume control dampers - North side Supply and fixing of extruded aluminium duct mounted volume control dampers. - south side Supply and fixing of extruded aluminium exhaust air diffusers with vloume control dampers. - south side Supply and fixing of extruded aluminium supply air diffusers with vloume control dampers - North side Supply and fixing of extruded aluminium supply air diffusers with vloume control dampers. - south side Supply and fixing of fusible link type fire damper (sleeve mounted) - North side Supply and fixing of fusible link type fire damper (sleeve mounted) - south side Supply and Installation of 25 mm diameter drain piping using UPVC Pipes along with necessary fittings. - North side Supply and Installation of 32 mm diameter drain piping using UPVC Pipes along with necessary fittings. - south side Supply and Installation of external duct insulation with 19 mm thick closed cell elastomeric nitrile rubber covered with 24G Aluminium cladding. - North side Supply and Installation of external duct insulation with 19 mm thick closed cell elastomeric nitrile rubber covered with 24G Aluminium cladding. - South side Supply and Installation of hot dipped galvanized CABLE TRAYS - 300mm wide perforated type - North side Supply and Installation of hot dipped galvanized CABLE TRAYS - 100mm wide perforated type - North side Supply and Installation of hot dipped galvanized CABLE TRAYS - 100mm wide perforated type - South side Supply and Installation of hot dipped galvanized CABLE TRAYS - 150mm wide perforated type - North side Supply and Installation of hot dipped galvanized CABLE TRAYS - 150mm wide perforated type - South side Supply and Installation of hot dipped galvanized CABLE TRAYS - 300mm wide perforated type - south side Supply and Installation of hot dipped galvanized CABLE TRAYS - 450mm wide perforated type - North side Supply and Installation of hot dipped galvanized CABLE TRAYS - 450mm wide perforated type - south side Supply and Installation of internal duct insulation with 12 mm thick closed cell elastomeric nitrile rubber - anti microbial. - North side Supply and Installation of internal duct insulation with 12 mm thick closed cell elastomeric nitrile rubber - anti microbial. - south side Supply and Installation of Microprocessor based Electrical panel with suitable rating incoming MCCB with digital KWH meter and outgoing feeders with suitable rating MCBs to the 3 Nos 11 TR condensing units and 1 No. AHU - South side Supply and Installation of Microprocessor based Electrical panel with suitable rating incoming MCCB with digital KWH meter and outgoing feeders with suitable rating MCBs to the 3 Nos 5.5 TR condensing units and 1 No. AHU. - North side Supply and Installation of Rectangular G.S.S. Ducting with MS angle flanges, complete with gaskets and supporting arrangement using MS angles / GI threaded rods etc - 22G - South side Supply and Installation of Rectangular G.S.S. Ducting with MS angle flanges, complete with gaskets and supporting arrangement using MS angles / GI threaded rods etc - 24G - South side Supply and Installation of Rectangular G.S.S. Ducting with MS angle flanges, complete with gaskets and supporting arrangement using MS angles / GI threaded rods etc. - 24G - North side Supply and Installation of spiral Round / Flat oval G.S.S. Ducting with coupling, complete with supporting arrangement using MS angles / GI clamps etc - 22G - south side Supply and Installation of spiral Round / Flat oval G.S.S. Ducting with coupling, complete with supporting arrangement using MS angles / GI clamps etc. - 24G - North side Supply and Installation of spiral Round / Flat oval G.S.S. Ducting with coupling, complete with supporting arrangement using MS angles / GI clamps etc. - 24G - South side Supply and Installation of suitable new thermostatic expansion valve and catch all filter driers along with necessary fittings - North side Supply and Installation of suitable new thermostatic expansion valve and catch all filter driers along with necessary fittings - south side Supply and laying power / control cabling of following sizes - control cabling between thermostat and Panel - 3C X 1.5 Sq.mm copper armoured - south side Supply and laying power / control cabling of following sizes - Power cabling from panel to AHU fan motor - 3C X 4 Sq.mm copper armoured - South side Supply and laying power / control cabling of following sizes - Power cabling from panel to condensing units (compressor) - 3C X 6 Sq.mm copper armoured - south side Supply and laying power / control cabling of following sizes - Power cum control cabling from panel to condensing unit (condenser fans + control) - 7C X 1.5 Sq.mm copper armoured - North side Supply and laying power / control cabling of following sizes - Power cum control cabling from panel to condensing unit (condenser fans + control) - 7C X 1.5 Sq.mm copper armoured - South side Supply and laying power / control cabling of following sizes. - control cabling between thermostat and Panel - 3C X 1.5 Sq.mm copper armoured - North side Supply and laying power / control cabling of following sizes. - Power cabling from panel to condensing units (compressor) and AHU fan motor - 3C X 4 Sq.mm copper armoured - North side Supply, Installation and Testing of 19 G Hard copper piping of following sizes (the suction line to be insulated with 19mm thick class O Armaflex with GC closed cell Nitrile Rubber precovered tubes with factory laminated glass cloth) including supporting fixtures and accessories etc., complete - South side - 1 1/8 inch Dia copper pipe with insulation Supply, Installation and Testing of 19 G Hard copper piping of following sizes (the suction line to be insulated with 19mm thick class O Armaflex with GC closed cell Nitrile Rubber precovered tubes with factory laminated glass cloth) including supporting fixtures and accessories etc., complete - South side - 7/8 inches Dia copper pipe Supply, Installation and Testing of 19 G Hard copper piping of following sizes (the suction line to be insulated with 19mm thick class O Armaflex with GC closed cell Nitrile Rubber precovered tubes with factory laminated glass cloth) including supporting fixtures and accessories etc., complete. - 5/8 inch Dia copper pipe - North side Supply, Installation and Testing of 19 G Hard copper piping of following sizes (the suction line to be insulated with 19mm thick class O Armaflex with GC closed cell Nitrile Rubber precovered tubes with factory laminated glass cloth) including supporting fixtures and accessories etc., complete. - 7/8 inch Dia copper pipe with insulation - North side Supply, Installation, Testing and Commissioning of 11TR nominal capacity Air cooled condensing unit consisting of scroll compressor, copper condenser coil of copper tubes and blue hydrophilic coated aluminium fins, condenser fans, etc suitable for operating an eco friendly refrigerant R-407C including necessary accessories like rubber pads etc - South side Supply, Installation, Testing and Commissioning of 5.5 TR nominal capacity Air cooled condensing unit consisting of scroll compressor, copper condenser coil of copper tubes and blue hydrophilic coated aluminium fins, condenser fans, etc suitable for operating an eco friendly refrigerant R-407C including necessary accessories like rubber pads etc. - North side Supply, Installation, Testing and Commissioning of new Air handling unit (horizontal floor mounted) in double skin construction with 0.8 mm plain G.I. Inner skin and 0.8 mm pre-coated GI outer skin, thermal break Aluminium profile with thermal barrier, 43 mm thick PUF panels - Capacity 4300 CFM airflow rate 60 mmwc static - South side Supply, Installation, Testing and Commissioning of new Air handling unit (vertical floor mounted) in double skin construction with 0.8 mm plain G.I. Inner skin and 0.8 mm pre-coated GI outer skin, thermal break Aluminium profile with thermal barrier, 43 mm thick PUF panels - Capacity 4300 CFM airflow rate 60 mmwc static - North side
# Schedule Awarded To Bids Value 1 Dismantling, shifting and handling over to TTD stores of existing 1 No 15 TR packaged unit along with its air cooled condesers - North side VoltasLimited 1 ₹7,059 2 Dismantling, shifting and handling over to TTD stores of existing 3 Nos 7.5 TR indoor type Air Handling units - south side VoltasLimited 1 ₹14,118 3 Earthing - 8 SWG GI Wire - North side VoltasLimited 1 ₹2,175 4 Earthing - 8 SWG GI Wire - south side VoltasLimited 1 ₹2,175 5 Painting of ducts with one coat of zinc chromate yellow primer and 2 coats of enamel paint of approved colour - North side VoltasLimited 1 ₹24,720
Show All 56 Schedules