| 1 | L1₹13.2 LAccepted-AOC 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L1 | Accepted-AOC M/S Mahaveer Traders is the Lowest Bidder, hence accepted | |
| 2 | L2₹14.7 L+₹76,803 (5.50%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹15.3 L+₹1.3 L (9.30%)Rejected-Finance 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹15.5 L+₹1.5 L (10.8%)Rejected-Finance NO 28 KUMHARON KI BASTI DHOONDHA BARMER RAJASTHAN 344035 | BARMER | RAJASTHAN | 344035 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | L5₹15.8 L+₹1.8 L (12.9%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L5 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Sh Nitish Pathak,EE
GE (AF) Phalodi
REPAIR TO LT CABLE, LT PANEL BOARD AT TECH AREA AT AF STN PHALODI
2024_MES_666249_1
8608/A/E8
Open Tender
Civil Works
Item Rate
180 days
Air Force Station
Class E Category b(i)
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹36,000
Yes
15 Oct 2024
16 Jul 2024
19 Sept 2024
16 Jul 2024
12 Sept 2024
29 Jul 2024
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/losse soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Disconnecting and Taking out of old LT armored PVC cables of any size/core/any voltage grade from trenches for replacement complete all as specified and directed.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4.0 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
S& F in replacement aluminium cable lug of size of cable lug 25 sqmm complete all as specified and directed.
S& F in replacement aluminium cable lug of size of cable lug 35 sqmm complete all as specified and directed.
S& F in replacement aluminium cable lug of size of cable lug 50 sqmm complete all as specified and directed.
S& F in replacement aluminium cable lug of size of cable lug 70 sqmm complete all as specified and directed.
S& F in replacement aluminium cable lug of size of cable lug 95 sqmm complete all as specified and directed.
S& F in replacement aluminium cable lug of size of cable lug 120 sqmm complete all as specified and directed.
S& F in replacement aluminium cable lug of size of cable lug 150 sqmm complete all as specified and directed.
S& F in replacement aluminium cable lug of size of cable lug 185 sqmm complete all as specified and directed.
S&F in replacement aluminium crimping connectors of size of crimping connectors 25 sqmm complete all as specified and directed.
S&F in replacement aluminium crimping connectors of size of crimping connectors 35 sqmm complete all as specified and directed.
S&F in replacement aluminium crimping connectors of size of crimping connectors 50 sqmm complete all as specified and directed.
S&F in replacement aluminium crimping connectors of size of crimping connectors 70 sqmm complete all as specified and directed.
S&F in replacement aluminium crimping connectors of size of crimping connectors 95 sqmm complete all as specified and directed.
S&F in replacement aluminium crimping connectors of size of crimping connectors 120 sqmm complete all as specified and directed.
S&F in replacement aluminium crimping connectors of size of crimping connectors 150 sqmm complete all as specified and directed.
S&F in replacement aluminium crimping connectors of size of crimping connectors 185 sqmm complete all as specified and directed.
M&L for cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line and finished surfaces by extracted material and provided with 150mm thick PCC (1:3:6) type C-2 as top layer to match the existing surfaces and remove surplus extracted material 50 m away complete all as specified and directed.
S&F 50 mm bore tube, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in LT panel foundation including demolition of old PCC complete all as specified and directed.
M&L for making of surface for painting duly scrubing the existing paint and applying two coats of synthetic enamel paint over a coat of red oxide primer for LT panel board/Feeder piller box of any size/type at various location complete all as specified and directed.
M&L for servicing to Outdoor/Indoor type LT panel Board of any capacity/size by replacing pitted portion area not exceeding 1.0 sqm with suitable gauge of MS sheet,welding work,replacement of unservicable door hinges and locking arrangement complete all as specified and directed.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 63 Amps, 16 KA rating,Ics=75% Icu ,415 volts AC complete all as specified and directed.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 125 Amps, 16 KA rating,Ics=75% Icu ,415 volts AC complete all as specified and directed.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 160 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 200 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 250 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 350/400 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S&F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB four pole 630 Amps, 50 KA rating, 415 volts AC complete all as specified and directed.
S&F in replacement isolator four pole 125 Amp, C curves MCB repturing capacity 16 KA complete all as specified and directed.
S&F in replacement MCB TPN 63 Amp, C curves MCB repturing capacity 10 KA complete all as specified and directed.
S&F in replacement MCB SPN 40 Amp, C curves MCB repturing capacity 10 KA complete all as specified and directed.
S&F in replacement MCB SP 6-32 Amp, C curves MCB repturing capacity 10 KA complete all as specified and directed.
S&F in replacement of volt meter 0-500 Volt digital type square 96 sq mm lamp accurracy glass complete all as specified and directed.
S&F in replacement of Ammeter 0-200 Amp digital type square 96 sq mm lamp accurracy glass complete all as specified and directed.
S&F in replacement power contactor 415 Volt, 50 HZ, 3 phase, type 400 Amp suitable for fixing in AMF panel of DG of capacity 200 KVA complete all as specified and directed.
S&F in replacement LED batten fitting 1 x18/20 Watt, 220 V decorative box type with driver 4" complete fitting connection with 3 core flexible copper cable 23/0.00076 from ceiling rose to tube fitting etc complete all as specified and directed.
S&F in replacement LED light fitting 9/10 Watt 2 feet light luminarire with polycarbonet cover complete with all acessories and driver including connection with 3 core copper wire of suitable size complete all as specified and directed.
S&F in replacement LED light fitting, 1x25 Watt complete glass protection IP:65/66, fixed to walls with GI brackets made out of suitable size of light grade pipe 32mm dia tubing upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3mm MS flat iron with suitable bolt and nuts and testing complete all as specified and directed.
M&L for earthing complete with copper earth plate 600 mmx600 mm x3.15 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including copper strip 20x3mm by means of bolts, nuts, check nuts and washers of copper/brass including providing of alternate layer from bottom edge to 30cm above top edge of earth plate by chemical fill compound, ground enhancing material, earth powderand after that 1 m back of layer of charcoal dust and common salt including PCC pit in PCC (1:2:4) type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle including excavation and earth work in any type of soil and medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) Contractor shall be produced the result of earth below 1 Ohm othrewise earthing will not be acceptable.
S&F in replacement LED aviation obstruction light 12 watt with light dependent sensor, IP:65 protected complete all as specified and directed.
S&F in replacement LT cable straight through jointing kit heat shrink type of 70 to 150 Sqmm cable size complete all as specified and directed.
S&F in replacement CT coil suitable for Amp metre 100/5 Amp complete all as specified and directed.
S&F in replacement indicating lamp set RYB for phase indication operating 240 Volt 50 Hz AC with new one LED panel mounting type as per existing make and type complete all as specified and directed.
Labour only for taking down of cable and relaying in trenches as per existing cable of any size complete all as specified and as directed. Note : Earthwork shall be measured and paid seprately under respective item of schedule.
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x 6mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 25X4mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level.
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x 6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 32X6mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI strip 32 x 6mm from top of earth plate up to 7.5 meter above ground level.
M/S SOLANKI GENERAL SUPPLIERS (BID ID -3093879)
Deccan Enterprises (BID ID -3085632)
DEVARAM CONSTRUCTION COMPANY (BID ID -3086454)
KRISHNA CONSTRUCTION COMPANY (BID ID -3075959)
M/S HARIOM CONSTRUCTION COMPANY (BID ID -3094308)
Multicare Enterprises Pvt. Ltd. (BID ID -3094179)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .