Loading…
Loading…
Tender Value
₹13.8 L
EMD Value
₹13,800
Closing Date
6 Jul 2026, 6:00 pmClosed
Executive Engineer, Electrical (R&B) Division, Valsad
Providing Solar Rooftop System on New ANS Girls Hostel Bahej Ta Khergam Di Navasari.
317530
TENDER NOTICE NO. 05 OF 2026-27
Open
Electrical Works
Works
Valsad
8 documents required · 8 mandatory
₹900
Executive Engineer, Electrical (Rand B) Division, Valsad
₹13,800
24 Jun 2026
24 Jun 2026
24 Jun 2026
6 Jul 2026
24 Jun 2026
Name of work : Providing Solar Rooftop System on New ANS Girls Hostel at Bahej, Ta. Khergam, Di. Navsari.
Qnty Unit Sr.No. SOR No. Item Description Rate After Rs in Words Amount
1 14-1-1. Supply, Installation, Testing & Commissioning of following size of Grid Tied
Solar Power Plant with
Solar Panels (ALMM approved): Frame Material : Anodized Aluminum alloy
Frame With Twin Wall Profile, Front Cover : High Transmission Low-Iron
Tempered Glass (AR Coated), High efficency and positive power tolerance
Pmax: 0/+5, Module Efficiency should be approx. 19.5%-22%, Normal
operating temperature 45'C, Junction Box with Waterproof IP67 & MC4
Compatible and Enclosed with Bypass diodes, 100% Electroluminescence test
to ensure error free Modules, Thep. temp. co-efficient of the PV module shall
equal or better than -0.45%/degree C. Solar PV modules of minimum fill
factor 75% to be used. Unit Production:- More than 4.5 Unit /kw /day
(Actual)(1Year Avg) With 10 year Product warranty and 25 year Linear
Power Warranty includes all mechanical and electrical parameters of the Solar
panel. Modules must be complied to the DCR(Domestic content
requirements). The Ration of AC to DC is 5:6 for the Installation capacity
which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency:
97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p
Power Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C,
Integrated protection of Inverter are Anti-islanding Protection, Input Reverse
Polarity Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current Protection, Output
Short Circuit Protection, Output Over Voltage Protection, PV array string
fault Protection. Protection Degree: IP65, User Interface LCD & APP,
Datalogger & Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit Integrated, Output
Over Current Protection Integrated, Output Short Circuit Protection
Integrated, Output Over Voltage Protection Integrated, Protection Degree:
IP65, User Interface LCD & APP,Datalogger & Communication: GPRS / Wi-
Fi, Module Mounting Structure: The mounting (Rectangular pipe / square
pipe / circular pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot
deep galvanized with minimum 80micron coating. The Rectangular / square
/circular hollow pipe section used for the structure should have a minimum
thickness of 2.0 mm. other than above, the material thickness should be
minimum 2.5 mm. A certificate of a structural engineer certifying the strength
and stability of the mounting structure to withstand the weight and wind speed
of 150 km/hour throughout the life span of 25 years of the system, shall be
submitted by the vendors. Hot Dipped Galvanized steel coils. suitable
arrangement for base plate for foundation , solar panel mounting, the structure
should be suitable for carry the load of solar panel,wiring, sprinkler system
etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the
nut bolt used for installtion of stucture should be (SS 304) quality.The ground
clearance of the bottom most edge of solar panel shall not be less than
mm to 1200 mm or as per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM
Balane of System with necessary Swichgears (Suitabel size and protection of
ACDB & DCDB), inter connecting wiring, earthing system as per the CEIG
drawing approval, lightining arrester system as per the CEIG drawing
approval, all liasoning work with various gov. dipartment like state nodal
agency,DISCOM & CEIG is included in agency scope
(Excluding All charges namely GEDA Application fees, Solar connectivity
Charges, Meter connectivity Charges, Meter testing Charges and system
stability/strenthning charges.)
30 Per (D) Grid Tied Solar Power System: 26 - 50 kW (3 - phase) 42156.39 Rupees Forty
KW Two Thousand
30 Per 2 14-9-1. Providing & erecting Automatic solar panel cleaning system for solar power 3681.45 Rupees Three
KW projects which includes necessary plumbing work (UPVC pipes and Thousand Six
accessories) from source of water to project site (upto 30 meters),Suitable Hundred Eighty
size of sub mercible/ open well motor, necessary wiring for motor and One And Paise
sprinkler system with safety, timer circuit for automatically on/off the Forty Five Only
sprinkler system, necessary size oand number of nozzles/JET (minimum
Nozzle/Jet per module). (D) 21KW-50KW Cleaning System
Deputy Executive Engineer Executive Engineer
Electrical R & B Sub-Division Electrical R & B Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Schedule B Bahej Hostel.pdf
Supplying Insatalling Solar.pdf
ELEGIBILITY CRITERIA.pdf
TENDER NOTICE NO. 05 OF 2026-27.pdf
4.0 FINAL _ SBD (Electrical Work) _ 2024 _ 120 pg (1).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .