Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹2.2 LAccepted-Finance | l1 | Accepted-Finance found in order |
Tender Value
Refer Docs
EMD Value
₹4,703
Closing Date
3 Oct 2024, 10:30 amClosed
AC Elect SHQ BSF Baramulla
AC(ELECT) SHQ BSF BARAMULLA
as per nit
2024_BSF_827663_1
24535-42
Open Tender
Electrical Works
Item Rate
30 days
THQ MOHURA, URI
please ref tender documents
9 documents required · 9 mandatory
₹0
₹4,703
29 Oct 2024
24 Sept 2024
4 Oct 2024
24 Sept 2024
3 Oct 2024
24 Sept 2024
Amount
ITC of existing hybrid solar inverter of 48V, 5500 VA with TRUE sinewave peak (6 KW Normal rating) AC 220 -240 volt 50 Hz output, IP 65 protection make Cellcronic
ITC of existing LiFePO4 maintenance free Battery 48V, 100 Ah Hybrid 5 KW Solar System, BMS technology for individual battery, Suitable for wall/Rack mounted, and mounted by means of suitable mounting plate by means of nuts and bolts etc required, make Cellcronic
Fixing of existing copper bus bar of size 25mm (width) X 5 mm (thick) X 1 feet length of 02 Nos on the rubber insulated bushings in the CRCA Sheet 2 mm thick elclosed chamber, busbar suitable to withstand DC current 150Amp, with cable in / out arrangement at the bottom of chamber, wall mounted, front openable door, hinged lock arrangement, with necessary screws, nut, bolt, washers, etc as required.
Installation of existing varnished wooden rack of 5 rows, size of each compartment space - 650 mm (width) X 800 mm (depth) X 450 mm (Height) with front openable double door and other five sides covered by wood, locking arrangement and 30 cm dia hole on left and back side of each comparment for cable in-out arrangement
Installation testing commissioning of existing mono perc half cut solar PV module, 435-445 Watt (144 cell) , make VIKRAM
Fixing of existing C type channel galvanised iron as per latest IS 2062 (91992), (Hot Dip, not less than 80 micron GI coating, as per IS 5905), 80 mm X 40 mm X 12mm size , 3 mm thickness for front leg - 2.51 m, Back Leg-3.48, 04 Nos at tilt angle 45 degree or ground requirement , C type GI 80 mm X 40 mm X 12 mm, 3 mm thick for rafter-3.5 m, 04 Nos, C type GI 40 mm X 40 mm X 10 mm, 2 mm thick for purlin- 6.60 m, 04 Nos , with base plate 1x1 feet, 5mm,capable to withstand wind speed 150 Km/Hr and snow load 5400 pa and various size assemblies with suitable nuts, bolts, clamp and washers by SS 304 materials suitable for mounting on ground as per latest IS 4759.CPCV pipe of 0.5 inch outer dia mounted above the top row of solar PV module and other accessories like end cap, union, elbow, etc. with .5 HP single Phase monoblock motor connected with the pipe structure.
Providing of C type channel galvanised iron as per latest IS 2062 (91992), (Hot Dip, not less than 80 micron GI coating, as per IS 5905), 80 mm X 40 mm X 12mm size , 3 mm thickness for Back Leg-3.90 Mtr
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1 m, size - 1 m X 1 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), 75 cm below the ground, 75 cm above the ground, 60 cm X 60 cm size in foundation of pump, DG set etc including form work etc as required.
Earthing with Copper earth plate 600mm x 600mm x 3mm/ thick including accessories, providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr laying etc. with brown mixed compond chemical earthing complete as required.
Providing & Fixing 25mm x 5mm Copper strip on surface or in recess for connectiopnj etc as required.
Providing & Fixing 25mm x 5mm Copper strip in 40mm size medium class G.I. pipe from earth electrode in i/c connection with brass, nut bolt, spring washer, excavation and refilling etc. as required.
Earthing with G.I earth plate 600mm x 600mm x 6mm/ thick including accessories, providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr laying etc.with brown mixed compond chemical earthing complete as required.
Providing & Fixing 25mm x 5mm G.I strip on surface or in recess for connectiopnj etc as required.
Providing & Fixing 25mm x 5mm G.I strip in 40mm size medium class G.I. pipe from earth electrode in i/c connection with brass, nut bolt, spring washer, excavation and refilling etc. as required.
Fixing of lightning conductor finial, made of 30 mm dia 100 cm long copper rod as per IS 3070, having multiple prong at top, including copper rod should be gas welded with 100mm dia 6 mm thick circular shape copper base plate, the entire structure mounted on 100 mm dia hot dip MS pipe (Heavy Class) of length 7 mtr, fixing in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), 100 cm below the ground, 30 cm X 30 cm size to withstand wind speed 150 Km/Hr.
Providing & Fixing 25mm x 5mm G.I strip in the existing 100mm dia heavy class G.I. pipe from copper base plate to GI earth plate, making connection by 4 No's of tinned brass/SS bolts, nuts, check nuts and spring washers etc and by necessary arrangement for draw out GI strip outside.
Drawing of existing flexible tinned strandred DC copper conductor single core 10 sqmm(Solar Cable),suitable to 435-450 watt solar panel, 5 KW solar Power Plant as per TUV specification , LSZH insulation, LSZH sheathed Protection washers etc from Array junction box to main junction box/inverter Part II direct in ground 30 cm below ground level including exvaction and refilling the trench but excluding sand cushoning and protective covering etc as required,
Drawing existing flexible tinned strandred DC copper conductor single core 25 sqmm(Solar Cable),suitable to 435-450 watt solar panel, 5 KW solar Power Plant as per TUV specification , LSZH insulation, LSZH sheathed Protection washers et in the existing surface/recessed steel/pvc conduit and making connections by MC4 connector, washers etc from Inverter to battery Array etc as required.
Supplying and drawing of 6 sqmm FRLSH flexible annelead multistraned AC copper conductor as per IS-8130,PVC insulated un-sheathed, 1100 V AC, Low smoke, Halogen free, from inverter to ACDB and makining connection etc required.
Fixing of existing 2+4 way DCDB of CRCA sheet 2 mm thickness front openable single door with acrylic laminated cover, HRC Fuse carrier-02 nos, double pole 200 V - 500 V DCMCB, 63 Amps with connections ,testing and commissioning etc as required.
Fixing of existing Double pole 1200 Vdc, 20 KA, Type 2 DC SPD with separate modular case, Imax 40 kA, Maximum upto 4 KV, without remote signalling, wall mounted with front openable single door with / without acrylic laminated cover with connections ,testing and commissioning etc as required.
Fixing of 2+6 way AC DB, 2mm thick CRCA Sheet, 240 V AC, front openable double door, DP AC MCB 40 Amp, C type-01 No, SP AC MCB 10 Amp- 04 Nos B series, SP AC MCB 16 Amp-02 nos C series, Netural & earth connector, din rail arrangement, suitable to wall mounted with nuts, bolts, screws, washers etc & necessary interconnection, testing and commissioning etc as required.
Fixing of Double pole 320 Vac, In-20 kA, Imax-40 kA, upto 1500V, AC without remote signalling, AC Type 2, SPD with separate modular case, wall mounted with front openable single door with/without acrylic laminated cover and supply of one spare cartridge with connections ,testing and commissioning etc as required.
Dismantling of existing hybrid solar inverter of 48V, 5500 VA , Battery 48 Volt 100 AH ,Copper Bus Bar, ACDB, DCDB, 1200 Volt VDC 20 KA, 320 VAC , Earthing Copper Bus Bar and Wiring etc
Dismantling of existing half cut solar PV Module, Rafter,Purling ,Front Leg ,Back Leg ,0.5 HP Motor ,CPVC Pipes and wiring etc
Dismantling of existing Lightning Arrestor and GI strip etc
Dismantling of existing Control Room
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Fixing of existing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per direction of engineer in charge
Carriage for AI Post Gun post to THQ Mohura of existing half cut solar PV Module, Rafter,Purling ,Front Leg ,Back Leg ,0.5 HP Motor ,CPVC Pipes ,Lightning Arrestor ,GI strip,hybrid solar inverter of 48V, 5500 VA , battery 48 Volt 100 AH ,Copper Bus Bar,ACDB,DCDB,1200 Volt VDC 20 KA,320 VAC ,Wooden rack , CGI sheet & Angles of Control Room ,hand gloves , Fire extingusher, Earthing Copper Bus Bar and Wiring etc
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .