| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.4 LAccepted-AOC D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹62.8 L+₹12.4 L (24.6%)Rejected-Finance H NO 9 9 1 1 DOCTOR S COLONY SHIVAJIPALEM VISAKHAPATNAM 530 017 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530017 | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹82.6 L+₹32.3 L (64.1%)Rejected-Finance 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | Rejected-Technical 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | - | Rejected-Technical Being not enlisted in requisite category of work |
Tender Value
₹83.6 L
EMD Value
₹1.5 L
Closing Date
4 Oct 2024, 6:00 pmClosed
Col Akhil Mehrotra, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SPECIAL REPAIRS TO REPLACEMENT OF BER LIFTS AT INDRAVATI BLDG AT NCB AREA UNDER GE UTILITY II VISAKHAPATNAM
2024_MES_652852_3
82442/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class C and Category c ii
9 documents required · 9 mandatory
₹1,000
GE Utility II
₹1.5 L
Yes
16 Dec 2024
12 Sept 2024
7 Oct 2024
12 Sept 2024
4 Oct 2024
20 Sept 2024
Amount
[c] Battery operated emergency light [LED Ceiling Fitting] alarm [speaker for emergency alarm system to be fixed] and stop button in car with rechargeable arrangement for battery. [d] Designer sleek circular LED light fitting 5 Watts x 4 Nos. in false ceiling. [e] Provision of one cross flow fan suitable for recessed mounting in false ceiling. [f] Provision of premium quality Jet black Granite stone slab of 18-20 mm thick as in flooring for lift car (Not more than two parts) over 3 mm thick aluminium chequered sheet. [g] Nonstop button/ independent operation. [h] Over load warning indicator with both audio and visual type with overload protection/ tripping system having relays , etc. [j] Front landing door operations with a minimum time of 10 sec and up to a maximum time of 30 seconds. [k] Stainless steel sliding doors with front opening for all Landings made of 16 gauge stainless steel sheet with Mirror finish with vision panel of size 300 X 1700mm covered with 8mm thick toughened plain glass. [l] All the dimensions of the lift and connected items shall be designed in conformity with IS 14665 standards and the contractor shall submit the design drawing to Accepting Officer for approval before commencementof work. The body shall be stainless steel of 16 gauge with Mirror finish with 38mm dia stainless steel (SS304) hand rail with hairline finish. [m] Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. [n] Specification plate with complete details [o] Full length display indicator panel.
[q] Provision of suitable phase reversal relays to the controller to protect lift/ equipment against phase reversal, phase failure and low voltage. [r] Provision of Intercom. [s] Continuous earthing for machine and equipment [t] Steel Wire rope of adequate size as per relevant IS and as per manufacturers specification. [u] Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, car operational panel, governor, locks, power control and trailing cables complete all as per latest IS specifications. [v] Main drives and controls shall be high efficient and low power consumption. [w] Lift design, specifications, drawings, manufacturers instructions shall be got approved from Accepting Officer before placing order for procurement. [x] The contractor shall carry third party load testing for each lift installed once in every six months till completion of defect liability period and shall submit satisfactory inspection report and the rate quoted shall be deemed to be included for this provision. [y] The Contractor shall shift the old dismantled lift to MES Storeyard as per direction of Engineer-in-Charge and the rate quoted shall be deemed to included transportation charges.
[c] Battery operated emergency light [LED Ceiling Fitting] alarm [speaker for emergency alarm system to be fixed] and stop button in car with rechargeable arrangement for battery. [d] Designer Six sleek circular LED light fitting 8 Watts x 6 Nos. in false ceiling. [e] Provision of one cross flow fan suitable for recessed mounting in false ceiling. [f] Provision of premium quality Jet black Granite stone slab of 18-20 mm thick as in flooring for lift car (Not more than two parts) over 3 mm thick aluminium chequered sheet. [g] Nonstop button/ independent operation. [h] Over load warning indicator with both audio and visual type with overload protection/ tripping system having relays , etc. [j] Front landing door operations with a minimum time of 10 sec and up to a maximum time of 30 seconds. [k] Stainless steel sliding doors with front opening for all Landings made of 16 gauge stainless steel sheet with Mirror finish with vision panel of size 350 X 1700mm covered with 8mm thick toughened plain glass. [l] All the dimensions of the lift and connected items shall be designed in conformity with IS 14665 standards and the contractor shall submit the design drawing to Accepting Officer for approval before commencementof work. The body shall be stainless steel of 16 gauge with Mirror finish with 38mm dia stainless steel hand rail with hairline finish. [m] Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. [n] Stainless steel hand rail 38mm dia with hairline finish. [o] Specification plate with complete details [p Full length display indicator panel.
[q] Provision of suitable phase reversal relays to the controller to protect lift/ equipment against phase reversal, phase failure and low voltage. [r] Provision of Intercom. [s] Continuous earthing for machine and equipment [t] Steel Wire rope of adequate size as per relevant IS and as per manufacturers specification. [u] Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, car operational panel, governor, locks, power control and trailing cables complete all as per latest IS specifications. [v] Main drives and controls shall be high efficient and low power consumption. [w] Lift design, specifications, drawings, manufacturers instructions shall be got approved from Accepting Officer before placing order for procurement. [x] The contractor shall carry third party load testing for each lift installed once in every six months till defect liability period and shall submit staisfactory test results and the rate quoted shall be deemed to be included for this provision. [y] The Contractor shall shift the old dismantled lift to MES Storeyard as per direction of Engineer-in-Charge and the rate quoted shall be deemed to included transportation charges.
SERVO-TECH ENTERPRISES (BID ID -3125309)
Omega Elevators (BID ID -3117126)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .