| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance PLOT NO 1076 BEHERA SAHI NAYAPALLI BHUBANESWAR 751012 | KHORDHA | ODISHA | 751012 | Admitted-Finance |
| 3 | Admitted-Finance PLOT NO 420 7 NUASAHI NAYAPALLI BHUBANESWAR 751012 | BHUBANESWAR | KHORDHA | ODISHA | 751012 | Admitted-Finance |
Tender Value
₹12.2 L
EMD Value
₹24,356
Closing Date
12 Sept 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIRECTOR, NISER
NISER Bhubaneswar, Jatni
Provision of power supply to UPS and additional power points in CMRP
2022_NISER_709373_1
NISER/IWD-ELECT/CMRP/22-23/09
Open Tender
Electrical Works
Works
60 days
NISER Bhubaneswar, Jatni
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹24,356
Yes
14 Sept 2022
30 Aug 2022
13 Sept 2022
30 Aug 2022
12 Sept 2022
31 Aug 2022
DISTRIBUTION BOARD Supply,installation, testing & commissioning of following readymade distribution boards,double door, IP 43 degree protection complete with necessary, MCB isolators, MCBs, earth leakage circuit breaker (ELCB) etc., including interconnections with appropriate capacity size of PVC insulated copper conductor wires,suitable for concealed mounting /wall mounting with MS frame work of 40 x 40 x 5 mm MS angle iron, with M.S. enclosure fabricated out of min 18 SWG thick M.S.CRCA sheet with concealed hinged door, locking arrangement etc., including earthing clamps for both incoming & outgoing circuits,interconnections, per phase isolation kit as required,cable end box & wire way box if required, continuous copper earth wire in the wire way box with single/duplicate brass earthing terminals, danger board, name plate, flexible earthing for the door, metal treatment & powder coated painting, Phase Distribution drawing etc., all as per drawings (G.A. & fabrication drawing to be got approved), etc., relevant IS & instruction of Engineer-in-charge. Notes: 2. Blanking Plates shall be included in scope of work. 1. MCB shall be minium 10k breaking capacity (type-C) 3. DB shall be of standard readymade type as per catalouge no. from approved manufacturers as indicated in preferred makes of material. 4. Sample of various DB shall be got approved by E-I-C including G.A & fabrication drawing. 5. Routine tests will be conducted at factory as per relevant IS.
The double door type 12 way VTPN MCCB DB IP-42 comprising of the following : Incomer- 125 A FP, 16 kA MCCB -- 1 No. Outgoing -63 A TP MCB -- 4 nos Equavalent to Hager Cat. Ref. JN2B00004S16 L & T / Schneder / Siemens /Hager
250Amp panel board system. Incomer -250 A 25kA 3P MCCB- 1 no. Outgoing- 125A 25kA 3P MCCB- 4 nos. Equavalent to Hager Cat. Ref. JN2B00004S16 L & T / Schneder / Siemens /Hager
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 X 35 sq.mm + 2 X 6 sq.mm Cable Make: Finolex / RR Kabel / Polycab
Providing and fixing following rating and breaking capacity 4 pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, incoming & outgoing power cable replacement,making connections,etc. as required. 200A MCCB 4P, 50 kA 415V having Microprocess release, adjustable over current, Earth faultand short circuit protection . Ics=Icu 100% 50ka with ROM & Spreader.Operation should be with extended rotary handle. L & T / Schneder / Siemens
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 3.5 X 150 sq. mm Alluminium armoured cable
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.(clamped with 25/40x3mm MS flat clamp) 3.5 X 150 sq. mm Alluminium armoured cable
Supplying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size cable as required. 3.5 X 150 sq. mm Alluminium armoured cable Make: Polycab / Finolex / Universal
End jointing of following size cable by crimping with supply of .all jointing materials like solderless tinned copper cable socket, double compression cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminal as the specification and as per the instuction of Engineer-in-charge. 3.5 X 150 sq. mm Alluminium armoured cable (50mm) Make: Braco / Cornet / Dowells
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 4 X 25 sq. mm Alluminium armoured cable with double run 6 SWG GI earth wire (clamped with 1mm thick saddle) Make: Polycab / Finolex / Universal / NICCO / Torrent cable
End jointing of following size cable by crimping with supply of .all jointing materials like solderless tinned copper cable socket, double compression cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminal as the specification and as per the instuction of Engineer-in-charge. 4 X 25 sq. mm Alluminium armoured cable (35mm) with double run 8 SWG GI earth wire Make: Braco / Cornet / Dowells
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required with following MCB/ RCCB/ Isolator. 6 way (4 + 18), Double door – 1 No. 63 Amp 4 pole Isolator- 1 No. 63 Amp Double pole RCCB(Sensivity 30 mA)- 3 Nos. 16/25 Amp SP MCB- 10 Nos. Make:- Legrand / Hager / Schneder / Siemens
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed medium class PVC conduit as required termination with copper lugs , all complete and as per instruction of EIC. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Cable Make: Finolex / RR Kabel / Polycab
Supply, installation, testing & commissioning 32 X 6mm heavily hot dipped GI earth strip for ground conductors fixed with no.10 GI wood screws & 1-2 mm thick GI saddles with G.I machine screws or in ground at 500mm below including excavation in all types of soil/rock with protective backed bricks, temporary reinstatement & back filling of trench, interconnection of earth strip with welded joints and GI nut bolts & washers, painting with two coats of metallic Aluminium paint for above ground portion & painting with two coats of black bituminous compound for earth strip in ground etc. all as per drawing, specifications and as per the instructions of the Engineer-in-charge.
Supply installation testing and comissioning of Maintenance free chemical earthing : Electrode -The Electrode will be a solid steel rod (Copper Cladded Earth Electrode) of 17mm Dia and min 3 mtr length. The thickness of the copper coating will be 250 microns and uniform with tolerance level of 0.1 micron Earth electrode will carry UL Marking and pragati name engraved on each electrode. Earth electrodes will be visually inspected and checked for diamention and length before installation. Electrodes should not get physically crack or depleted in case of bending. (Including excavation and filling of material with the back field compound/Bentonite powder etc.) The electrode to be used to be tested and approved by CPRI Back fill Compound:- The Earth enhancenment material (backfill material ) - Back filled compound must have cmpostion of Carbon, silica,chloride, calcium, tin, Mg, Lead, PBB, PBDE etc.as per the ISO standard,IEC 62561-7 and ISO certified by Govt. of India and "LOHM" compound may be used if ISO certified. (Quantity : As required) . The chamber cover & frame shall be hinged type & it shall be got approved by department.The value of earth resistance and date of measurement shoud be written on the chamber cover with paint.
SUPDEX SERVICES PRIVATE LIMITED
M/S TATHAGATA ENGINEERING
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .